DS5000
Symbol
Direct Acting Type Air Pilot Type DS2000
(N. C.) (N. C.)
DX2R
OUT OUT
DP300∙
3000∙5000
IN IN DS6000
DX2
How to Order
DM
DW 10 1 C 01 VC
DH
1 2 3 4 5 6 7
DT220
� 2 Port Solenoid Valve
Applicable Fluid (Water, Air, Oil) Standard Specifications
※Option:Steam DC
Applicable Air, Water, Oil
� Body(Orifice Size) Proof Pressure 1.5MPa(213.35psi)
03 : ф2.5-Direct Type Solenoid
10 : ф10 Fluid Temperature 0~70�
C(32。
F~158。
F)
15 : ф15 Pilot Type Solenoid
Ambient and fluid temperatare Max. 60�
C(140。
F)
20 : ф20
25 : ф25 Electrical Entry Grommet, Conduit
� Blank : Standard
S : SUS Type
� VC : Vacuum Type(-100kpa)
(only AC Voltage)
B-3 PNEUMATICS
Series DW
Applicable Specifications
AC110, 220V(50/60㎐)
Coil Apparent Power
DC 6, 12V
Body Material Stainless steel(SCS13)
H Class(180�
C)(356。
F)
Coil Insulation
AC100, 110, 200, 220V Only
Model
Dimensions mm(inch)
01
DW � 03 - � G -
02
250(9.84)
Symbol
OUT
Port Size
59(2.32)
(PT1/8”
, 1/4”
)
IN
25(0.98)
9.5(0.37)
35(1.38) 26(1.02)
18(0.71)
2-M5×0.8
PNEUMATICS
B-4
Series DW
Dimensions mm(inch)
DW 10 - � C- 02
03
38(1.50) 250(9.84)
DW
Symbol
OUT DV100
DV1000∙
3000∙4000
96(3.78)
IN
PF 1/2 Port Size DS300
70(2.76)
(PT1/4”
, 3/8”
)
DS3000
DS5000
50(1.97)
DS2000
26(1.02) 2-M4×0.7
DX2R
DP300∙
26(1.02)
3000∙5000
(1.02)
26
DS6000
2-M6×1.0
DX2
DM
Dimensions mm(inch)
DH
DW15 - � C - 04
DT220
7)
1.7
5(ф DC
ф4
Symbol
OUT
50(1.99)
IN
38(1.50) 250(9.84)
103(4.06)
PF1/2
77(3.03)
14.5(0.57)
Port Size
(PT1/2”
)
66.5(2.62) 29(1.14)
50(1.97)
B-5 PNEUMATICS
Series DW
Dimensions mm(inch)
DW 20 - �C - 06
DW 25 - �C - 10
)
1.77
Symbol
(ф
ф45
OUT
65(2.56)
IN
38(1.5) (250[9.84])
PF1/2
122(4.8)
96(3.78)
Port Size
(PT3/4”
, 1”
)
21(0.83)
92(3.62) 42(1.65)
57.5(2.26)
65(2.56)
Precautions
Piping Wiring
� Piping should be thoroughly flushed to � The minimum diameter for wire connection
remove sludge, cutting oil, and dust. is 0.5mm2 .
� During piping and coupling connection, care � An electric circuit which prevents chattering
should be taken to prevent contamination by at the point of contact should be employed.
cut thread chips or sealing materials.(When � When the electric is apt to be damaged by
applying sealing tape to threads, one screw surge voltage, place a surge suppressor in
thread should extend beyond the tape.) parallel with the solenoid voltage suppressor
� Pay attention to the piping direction(IN, (option).
OUT). IN or other marks are indicated on the � The allowable voltage range is -10%~+10%
inlet side. of the rated voltage. However, if great
� The coil should not be subjected to an response is desired for DC power, the
extended force. When tightening, apply a voltage range should be within ±5% of the
wrench to the outside of the pipe mounting rated voltage. Voltage drop is measured at a
area only. part of the lead wire connected to the coil.
� The piping system should not be grounded. � The voltage found on both ends of the coil,
Grounding would cause electrolytic corrosion. when it deenergizes, is:AC:20% or less of
� To prevent collection of fluid within the the rated voltage DC:2% or less of the rated
piping circuit, install a relief valve within the voltage
circuit. The DC value is for a temperature of 20±5℃.
At lower temperatures, the DC value will be
lower.
PNEUMATICS
B-6
Series DW
Fluid Temperature
Refer to the temperature range for each model.
The temperature range changes according to
the sealing material, coil insulation, power,
supply, etc. Contact our representative for use
other than standard use.
B-7 PNEUMATICS