Agreed Sourcing Criteria

S.no Qualifications Requirement Applicant Experience


1 Do you have an Electrical -Yes. B.Eng Electrical Engineering degree from
Engineering Degree? If yes, please University of Bradford, UK (Namal College Campus)
provide details and confirm if your -Attested by British Council
degree is attested by the UAE Govt. -Not Attested by UAE Govt yet.
2 Do you have at least 5 years of -4 years’ experience of working at 220 KV
working experience within Transmission Substation Daud Khel, Punjab,
400KV/132KV Transmission Pakistan.
Substation? If Yes, kindly provide the -Visits to 500 KV Substation, Peshawar, Pakistan
list/details -Witnessed the commissioning of 160 MVA
Transformer at 220 KV Grid Station Shahi Bagh,
Peshawar.
3 Do you have experience working on 4 years of experience as Assistant Manager
Transmission Protection Relay (Protection and instrumentation). Carried out testing
experience within 400 KV/132 KV on SIEMENS, GEC (Static relays), GEC ALSTHOM
Transmission Substation? (Numerical), GE, MiCOM, SEL and BBC relays.

4 Did you have direct experience in the


following activities: a)Yes. Supervision of protection system installed at
a. Supervising Power System the substation.
Protection b) Manual as well as the emergency testing of
b. Testing & commissioning of installed protection. Also replaced the defective
protection systems relays and the commissioning of new relays at the
c. High knowledge in design and substation.
functionality of protection c) Yes. I have knowledge about the working
systems principles of the protection installed at the
d. High knowledge of transmission substation.
protection relays d) I have been testing the transmission protection
e. High experience in creating, relays for 3.5 years. These relays include
coordination and managing the SIEMENS, GEC (Static relays), GEC ALSTHOM
procedures in details testing of (Numerical), GE, MiCOM, SEL and BBC relays.
protection relay e) It is my responsibility at my substation to carry out
f. Progress Report generation and detailed testing of all the protections installed on
presentation Annual basis or as per SOP. I also Supervised
some testing on C. Bs i.e. timing tests, contact
resistance tests.
f) Yes. Test results compilation and generating a
report and presenting it to the higher officers is a
part of my duty here. We Generate a report after
every testing and also on weekly, monthly and
annual basis
5 Kindly provide details of the same or -Witnessed the commissioning of 160 MVA
similar Transmission/Substation Autotransformer in 220 KV Substation Shahi Bagh,
Projects you participated in your Peshawar, Pakistan
previous experiences -Installed and marshalled the O/C and E/F relay
7SJ6025 at 220 KV Substation, 220 KV Daud Khel,
Pakistan
-Installed and marshalled the under-frequency relay
installed at 220 KV Substation Daud Khel, Pakistan
-Installed and marshalled SEL-311 distance
protection relay at 220 KV substation Daud Khel,
Pakistan
6 Kindly provide your experience and I have been carrying out testing on the following
Relay Testing activities you have relays for the past 3.5 years.
been involved in: Over current relays
MiCOM P14N
7SJ602/7SJ600 (SIEMENS)
CDG (GEC)
SPAJ140C(ABB)
MCGG-52(GEC) MIFII Digital feeder relay (GE)
Distance Relay
MiCOM P443
7SA612, 7SA513, 7SA52, 7SA5111 (SIEMENS)
D-60, Quadramho, Micromho, OPTIMHO, PYTS,
L8B, L3wys, LZ31)
SEL-311
Multilin L90 (GE)
Differential Relay
MiCOM P642
7UT612
7UTS121
MCBH
MFAC (Bus Bar differential)
CTU12 (Over load relay)
MCGG-14 (REF relay)
MCGG-22 (Tertiary earth fault relay)
Over excitation relay RATUB (ABB)
Under frequency relay M2VFX22
7 Please provide details of your ABB (Relays)
experience in handling equipment Testing of ABB relays
(type of equipment and the tests Alstom
carried out) from the following Testing of Alstom Over current, distance and
manufacturers: differential relays
GE (Relays)
a. ABB Tested the MIFII Digital feeder relay and Multilin L90
b. Alstom line differential relay
c. Honeywell Siemens (Transformers, Relays)
d. GE TTR, C&DF tests of SIEMENS made transformers
e. Schneider Testing of over current, distance and differential
f. Siemens SIEMENS relays installed at the substation.
g. Others, please specify AEG (11 kv panels)
Shenyang Tranformers
Haefely (CVT, CT),
Sprecher Energie (Circuit Breakers)
Breaker timing tests and contact resistance tests
8 Do you have supervision experience Yes
while the above-mentioned tests were
carried out?
9 Do you have a Valid UAE/GCC No
Driving License? If Yes, please
provide further details
10 If you will be selected for the above- 1 Month
mentioned role, how many
days/weeks/months’ notice you need
to render before you can join the
project?