Вы находитесь на странице: 1из 1

A B C D E F G H J K L

KEY PLAN

SPECIAL NOTES:-
A) MOMENT CONNECTION DESIGN-
BEAM TO COLUMN CONNECTION SHALL BE DESIGNED FOR 100%
MOMENT AND 60% SHEAR CAPACITY OF THE BEAM.
B) SHEAR CONNECTION DESIGN-

1 b1. LOGITUDINAL DIRECTION BEAM TO COLUMN CONNECTION 1


SHALL BE DESIGNED FOR 60% SHEAR CAPACITY OF THE BEAM.
b2. BEAM TO BEAM CONNECTION SHALL BE DESIGNED FOR
1-04 1-05 1-06 80% CAPACITY OF BEAM. NOTES:

b3. ALL BRACING CONNECTIONS SHALL BE DESIGNED FOR 1. THIS DRAWING INDICATES THE DESIGN INTENT ONLY. ALL
STRUCTURE & MEP SERVICES ARE PURELY INDICATIVE AND MUST
80% TENSION CAPACITY OF MEMBER. BE VERIFIED AND CO- ORDINATED BY QUALIFIED AGENCIES PRIOR
TO THE COMMENCEMENT OF ANY WORK ON SITE.
C) GUSSET PLATES SIZES SHALL BE WORKED OUT BY FABRICATOR.
1450 MAX. TYP. 1450 MAX. TYP. 2. DO NOT SCALE OFF DRAWINGS. USE FIGURED DIMENSIONS
D) ALL SPLICE CONNECTIONS SHALL BE OF ONLY.
FULL STRENGTH OF MEMBER.
SLOPE SLOPE 3. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS, AND DO NOT
E) ALL CONNECTION BOLTS SHALL CONFIRM TO TAKE INTO ACCOUNT APPLIED FINISHES, UNLESS SPECIFICALLY
INDICATED OTHERWISE.
ASTM A325M CLASS 8.8 (830MPA MINIMUM TENSILE STRENGTH.)
4. ANY OMISSIONS OR DISCREPANCIES FOUND SHALL BE
F) STIFFENER PLATES,MOMENT CONNECTION PLATES TO BE REPORTED TO THE ENGINEER IMMEDIATELY.
DESIGNED & DETAILED BY FABRICATOR.
5. LEVELS ARE GIVEN IN METERS TO THREE DECIMAL PLACES
G) DIAMETER OF BOLT-MINIMUM 16Ø FOR ERECTION & ABOVE DM DATUM LEVEL.

2 20Ø FOR PERMANENT. 6. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE 2


RELEVANT SECTIONS OF THE SPECIFICATION AND SCHEDULES.

7. THE CONTRACTOR SHALL SUBMIT FULL SHOP / SETTING OUT


DRAWINGS FOR APPROVAL (BASED ON SITE DIMENSIONS) PRIOR
TO COMMENCEMENT OF ANY SITE WORKS, OR PLACING ANY
ORDERS AND OR MANUFACTURE OF ANY FITTINGS, FIXTURES
AND COMPONENTS SHOWN.

8. THE AREA GIVEN RELATE TO THE LIKELY AREAS OF THE


1500 Max. BUILDING AT THE CURRENT STATE OF THE DESIGN.
MEASUREMENT CONVENTION ARE AS AGREED BY CLIENT. ANY
DECISION TO BE MADE ON THE BASIS OF THESE PREDICTIONS,
WHETHER AS TO PROJECT VIABILITY, PRE-LETTING, LEASE
AGREEMENTS OR THE LIKE, SHOULD INCLUDE DUE ALLOWANCES
FOR THE INCREASES AND DECREASES INHERENT IN THE DESIGN
DEVELOPMENT AND BUILDING PROCESSES.

TYPICAL FRAME CROSS SECTION @ GRID 1-H


3 3

1-04 1-05 REV. NO. DESCRIPTION DATE


0 50% DEVELOPED DESIGN 2019/09/12

1450 MAX. TYP.


3 SLOPE 3

SLOPE CLIENT

MINISTRY OF DEFENSE
PENSION FUND

PROJECT NAME

DOWNE HOUSE MUSCAT,


OMAN

1500 Max. LEAD CONSULTANT

4 4
DIAMOND BUSINESS CENTER 2, OFFICE 119
Email:- info@graphite-arch.com | Web:- www.graphite-arch.com
Tele:- +971 55 853 8095
AOR & STRUCTURAL CONSULTANT

Design Group Engineering Consultants LLC


Muscat (Oman) + Bangalore (India)
P.O. Box 1102 l PC 131 l Mutrah l Sultanate of Oman l
Tel: +968-22522550 l Fax: +968-2481 9487 l
Email: info@dgcon.com l website:www.dgcon.com.

FRAME CROSS SECTION @ GRID 1-M -

5 5
-
aluminium
mullion for
1-04 1-05 skylight glass
support
hollow core steel
1450 MAX. TYP. 1450 MAX. TYP. profile

SLOPE SLOPE

6 6

DRG. ISSUE STATUS

DEVELOPED DESIGN
1500 Max.
DRAWING TITLE:

SENIOR SCHOOL MAIN SKY LIGHT

FRAME CROSS SECTIONS

TYPICAL FRAME CROSS SECTION @SKY LIGHT AREA DESIGNED


GPE
APPROVED
DRK
SCALE
1:100 @ A0

7 NOTE: 7
DRAWN FACILITY NO. STATUS
1. Concept
* ALL STRUCTURAL STEEL DRAWINGS ARE INDICATIVE SUJ 2. Schematic
ONLY 3. Detailed Design
CHECKED PRINTED ON :
* STRUCTURAL STEEL DRAWINGS TO BE DESIGN AND BUILT 4. Tender
BY STRUCTURAL STEEL CONTRACTOR WITH THE GPE Jan 16, 2020 5. Construction
CONSULTANT APPROVAL. ACM DRAWING NO. REVISION NO.

SS-204 1 0
STATUS REVISION
A B C D E F G H J K L