Вы находитесь на странице: 1из 4

company secret

:
Technical information transaction : up to agency
: open
Issue Number 02RDAL0006 Order of priority
Date 30 October, 2002 □A:reform immediately
Model JMA-9800 NCD-4111A □B:Improve with regular check or visiting
Equipment MARINE RADAR □C:Improve with customer’s request
Section in charge RADAR Group □D:Information and news

1. Subject
The information of Signal Processing Performance of JMA-9800 "NCD-4111A".
And how to change the parameter for getting better performance.

2. Contents
We have some worse performance in AUTO-RAIN and AUTO-SEA processing.
a) AUTO-RAIN mode
We have weak echo on display in using AUTO-RAIN because of harder effect in unti rain processing.
b) AUTO-SEA mode
We have noisy echo on display in using AUTO-SEA because of the setting for narrow display
dynamic range.
c)MANUAL-SEA mode
We have harder effect on CCW position in using MANUAL-SEA because of preset STC.

Then we have relaeased new software Ver.02.13, and we give how to change the parameters for signal
processing to get better result.
Please read “The modification method “ in Appendix.

2. Appendixes

a) The list of serial number of NCD-4111A


b) The modification method for signal processing of JMA-9800 ( NCD-4111A ).
The serial number list of JMA-9800 series NCD-4111A

These 1,090 units should be changed in Signal processing parameter.


The serial number of indicator unit NCD-4111A
LW21350 - LW21649
LW21350 - LW21649
LW21650 - LW21659
LW21835 - LW21844
LW21845 - LW21894
LW21895 - LW22094
LW22145 - LW22344
LW22480 - LW22729
LW22730 - LW22739
LW22860 - LW22909
LW22910 - LW22919

CAUTION!! : Don’t change the parameter of NCD-4111 ( without ‘A’ ).


How to confirm which the unit is with ‘A’ or without ‘A’.
a) Please check its serial number
NCD-4111A ( with ‘A’ ) : written in above
NCD-4111 ( without ‘A’ ) : LW21089 or before
b) How to check on unit
1) Press TEST , 7 then SYSTEM INFO will appear.
2) Please read its SYSTEM No.
NCD-4111A ( with ‘A’ ) : 02.xx ( x : don’t care )
NCD-4111 ( without ‘A’ ) : 00.xx or 01.xx ( x : don’t care )

The fact of software up date:


The products forwarded after 21st. Oct. 2002 have already changed in factory, therefore it’s not
necessary to change the parameters.
How to confirm its software version.
a) Please check its PCB of CMC-1143
It’s labeled “MAIN Ver.02.13” on PCB.
b) Please check its SYSTEM No. on TEST MENU – SYSTEM INFO.
Ver.02.13 or later : already changed
Ver.02.12 or before : not changed, please change the parameters.
The modification method for signal processing of JMA-9800

1. AUTO-RAIN
(1) The purpose
If the echo would be weak in using AUTO-RAIN mode, please change the following values.
(2) The method
a. Set the Radar as MASTER mode if you use Inter-Swiching-System.
b. Set the Radar as 1.5NM range and SHORT-PULSE (SP).
c. Continue to press MENU.
-> The CODE IPUT MENU will appear.
d. Press 9, 8, 0, 0, 9, 4, then ENT.
-> The SPECIAL SP MENU will appear.
e. Press CFAR button on the display by using CURSOR.
-> The CFAR MENU will appear.
f. Press the value of CELL NUMBER AR of MAIN.
-> The INPUT DIALOG BOX will appear.
g. Press 4, 0, then END.
h. Change the PULSE WIDTH to MP.
i. Press the value of CELL NUMBER AR of MAIN.
-> The INPUT DIALOG BOX will appear.
j. Press 4, 0, then END.
k. Change the PULSE WIDTH to LP.
l. Press the value of CELL NUMBER AR of MAIN.
-> The INPUT DIALOG BOX will appear.
m. Press 4, 0, then END.
n. Change the values in 3/6/12/24/48/96/120NM range as following table.

The values for MAIN – CELL NUMBER AR


RANGE Default Right value
1.5NM SP 20H 40H
MP 20H 40H
LP 20H 40H
3NM SP 20H 7FH
MP 20H 7FH
LP 20H 7FH
6NM SP 20H 7FH
LP 20H 7FH
12NM SP 20H 7FH
LP 20H 7FH
24NM 20H 7FH
48NM 18H 7FH
96/120NM 10H 7FH

CAUTION!! Don’t change other values except directed terms. If you change, you will get wrong
echo on your RADAR.

-1-
2. AUTO-SEA
(1) The purpose
If the picture would be noisy in using AUTO-SEA mode, please change the following value.
(2) The method
a. Continue to press MENU.
-> The CODE IPUT MENU will appear.
b. Press 9, 8, 0, 0, 9, 4, then ENT.
-> The SPECIAL SP MENU will appear.
e. Press DYNAMIC RANGE button on the display by using CURSOR.
-> The DYNAMIC RANGE MENU will appear.
f. Press the value of MULTIPLE CONST of MAIN.
-> The INPUT DIALOG BOX will appear.
g. Press 1, 7, then END.

MAIN – MULTIPLE-CONST
Default Right value
20H 17H

CAUTION!! Don’t change other values except directed terms. If you change, you will get wrong
echo on your RADAR.

3. MANUAL SEA
(1) The purpose
If the MANUAL SEA has harder effect on CCW position, please change the following value.
(2) The method
a. Continue to press MENU.
-> The CODE IPUT MENU will appear.
b. Press 9, 8, 0, 0, 1, then ENT.
-> The UTILITIES MENU will appear.
e. Press 7.
-> The SET FUNC MENU will appear.
f. Press 6.
-> The MAIN GSR PRESET MENU will appear.
g. Press 3.
-> The SEA MIN PRESET MENU will appear.
h. Press 0, then ENT.

MAIN – SEA MIN PRESET


Default Right value
100 0

CAUTION!! Don’t change other values except directed terms. If you change, you will get wrong