Вы находитесь на странице: 1из 4

Page 38 - 1

SEISMIC CALCULATIONS
TANK SUPPORT 38 Christy

10:08
01/26/20

ENGINEERING with the SPREADSHEET


Copyright 2006 American Society of Civil Engineers 456964173.xls

A B C D E F G H I J K L M N
SEISMIC CALCULATION WORKSHEET V = 0.304 W_Ultimate = 0.217 W_working stress
Z 0.3 unit seismic zone factor ZONE 1 2A 2B 3 4
soil SD soil profile type Z 0.075 0.15 0.2 0.3 0.4

Copy clip table values to reduce transcription errors. logic


SOIL PROFILE TYPE blows/ft
SA Hard rock 0
SB Rock >50 0
SC Very dense soil & soft rock 15 to 0 row 20
SD Stiff soil <15 5
SE Soft soil 0
SF Soil requiring evaluation 0
5

SEISMIC COEFFICIENT CA UBC TABLE 16 Q


SOIL SEISMIC ZONE FACTOR, Z
TYPE 0.075 0.150 0.200 0.300 0.400 row 30
SA 0.06 0.12 0.16 0.24 0.32
SB 0.08 0.15 0.20 0.30 0.40
SC 0.09 0.18 0.24 0.33 0.40
SD 0.12 0.22 0.28 0.36 0.44
SE 0.19 0.30 0.34 0.36 0.36
SF Soil requiring evaluation

Ca 0.36 unitless Ca The coefficient that defines the short period


ground motion for structures with a
fundamental period < Cv /2.5 Ca . row 40

SEISMIC COEFFICIENT Cv 97 UBC TABLE 16 R


SOIL SEISMIC ZONE FACTOR, Z
TYPE 0.075 0.150 0.200 0.300 0.400 logic
SA 0.06 0.12 0.16 0.24 0.32 0
SB 0.08 0.15 0.20 0.30 0.40 0
SC 0.13 0.25 0.32 0.45 0.56 0
SD 0.18 0.32 0.40 0.54 0.64 5
SE 0.26 0.50 0.64 0.84 0.96 0 row 50
SF Soil requiring evaluation 0
5
Cv 0.54 Cv The coefficient that defines the longer period
constant velocity ground motion.

The first five soil profile types are based upon soil
shear wave velocity. Values for SF require a soil
specific evaluation to establish site coefficients.
row 60
Page 38 - 2
SEISMIC CALCULATIONS
TANK SUPPORT 38 Christy

10:08
01/26/20

ENGINEERING with the SPREADSHEET


Copyright 2006 American Society of Civil Engineers 456964173.xls

A B C D E F G H I J K L M N
NEAR-SOURCE FACTOR Na 97 UBC TABLE 16 S ZONE 4 CALCULATION V = 0.304 W_Ultimate = 0.217 W_working stress
Distance 5 Km 3.11 miles -- Closest distance to known seismic source in Km
type C Seismic source type
SEISMIC SOURCE TYPE 97 UBC TABLE 16 U
The near source factors Na and Nv apply to Zone 4 A Faults that can produce large
calculations UBC 1628 Symbols and Notations magnitude events and have a high
rate of activity

B All faults other than A or C


row 70
CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE (Km) C Faults that are not capable of
2.00 5.00 10.00 and greater producing large magnitude
SEISMIC 0 1 1 events and have a low rate of
SOURCE 1 0 0 activity
TYPE 0 1 0 logic
A 1.50 1.20 1.00 1.00 0
B 1.30 1.00 1.00 1.00 0
C 1.00 1.00 1.00 1.00 4
4
Na 0.00 Na The acceleration based factor for choose
short period structures 5
10
NEAR-SOURCE FACTOR Nv 97 UBC TABLE 16 T ZONE 4 APPLICATION 5
Distance 5 Km 3.11 miles -- Closest distance to known seismic source in Km hlookup
type C Seismic source type 1
1
CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE (Km) 5
2.00 5.00 10.00 15.00 and greater 1
SEISMIC 0 1 1 1
SOURCE 1 0 0 0 row 90
TYPE 0 1 0 0
A 2.00 1.60 1.20 1.00
B 1.60 1.20 1.00 1.00
C 1.00 1.00 1.00 1.00 logic
0
Nv 1.00 0
4
NEAR-SOURCE CALCULATIONS Nv The velocity based factor for ground 4
Ca 0.36 unitless soil type factor 97 UBC Table 16Q motion periods > 1 second choose
Na 0.00 unitless near source factor from above 5
Ca*Na 0.36 unitless Ca*Na in Zone 4 UBC 1628 Symbols 10
IF(0.3 zone = 0.4 , 0.00 * 0.36 , 0.36 ) 5
Check with the local Building Official as to which hlookup
seismic zone and near source factors may be 1
Cv 0.54 unitless seismic coefficient 97 UBC Table 16R required. 1
Nv 1.00 unitless near source factor from above 5
Cv*Nv 0.54 unitless near source factor Nv used in Zone 4 Parts of the Oregon coast have been reclassified to 1
IF(0.3 = 0.4 , 0.54 * 1.00Nv , 0.54 ) Zone 4. More of western Oregon and Washington
see UBC 1628 Symbols and Notations may be reclassified to Zone 4 in the future.
row 110
Page 38 - 3
SEISMIC CALCULATIONS
TANK SUPPORT 38 Christy

10:08
01/26/20

ENGINEERING with the SPREADSHEET


Copyright 2006 American Society of Civil Engineers 456964173.xls

A B C D E F G H I J K L M N
SEISMIC CALCULATION WORKSHEET -- Continued V = 0.304 W_Ultimate = 0.217 W_working stress
Z 0.3 unitless zone acceleration factor from above R The structure response factor based upon the
soil SD alpha soil type Stiff soil structure configuration, stiffness, and force
amplification characteristics in an earthquake
R 2.9 unitless TABLE 16-P - R FACTORS for leading to a ratio of seismic base shear to the
NONBUILDING STRUCTURES ability of the structure to absorb energy and
11. All other structures not otherwise covered. inelastic deformations without collapse.

Note that the structure may be rendered useless


by the seismic event that it was designed for
I 1.25 unitless importance factor under this system. However, some designs
account for inelastic deformations and the
hn 75 ft building height continued use of the structure with or without
Ct 0.030 unitless building period factor based upon repairs.
construction style 97 UBC 1630.2.2
Ct = 0.030 for reinforced concrete moment-resisting
frames and eccentrically braced frames. I importance factor

T 0.765 seconds Ct * hn^0.75 . (30-8) natural period .. T > 0.06 Flexible nonbuilding structure ..
0.030 * (75.0^0.75 ) use UBC 1630.5 V = Ft + sum Fi .. row 130

V rigid 0.315 * W 0.7 * Ca * I * W (34-1) V lateral force, * W


0.7 * 0.36 * 1.25 * W
1630.2.2
Ct = 0.035 for steel moment resisting frames
V flexible 0.304 *W Cv * I / (R * T) *W (30-4) Ct = 0.030 for reinforced concrete moment-resisting frames
0.54 * 1.25 / (2.9 * 0.765) * W and eccentrically braced frames.
Ct = 0.020 for all other buildings
V 0.304 *W flexible structure ..
row 140

Vmax 0.388 *W 2.5 * Ca * I / R * W (30-5) maximium lateral force


2.5 * 0.36 * 1.25 / 2.9 * W

Vmin 0.050 *W 0.11 * Ca * I * W (30-6) this value sets the lower bounds for long period structures
0.11 * 0.36 * 1.25 * W Ca is multplied by Na in Zone 4 calculations

Structure 1 input 0 = building structure 0.8 in (30-7), 1 = non building structure 1.6 in (34-3) row 150

Vmin_4a 0.252 *W 0.56 * Ca * I * W (34-2) for non-building structures


0.56 * 0.36 * 1.25 * W Ca is multplied by Na in Zone 4 calculations
1 logic for flexible nonbuilding structures 1634.5

row 160
Page 38 - 4
SEISMIC CALCULATIONS
TANK SUPPORT 38 Christy

10:08
01/26/20

ENGINEERING with the SPREADSHEET


Copyright 2006 American Society of Civil Engineers 456964173.xls

A B C D E F G H I J K L M N
SEISMIC CALCULATION WORKSHEET -- Continued V = 0.304 W_Ultimate = 0.217 W_working stress

1.00 unitless near source factor for Zone 4 calculations


Vmin_4b 0.207 *W 0.8 in (30-7), 1.6 in (34-3) * Z * N v * I / R * W (34-3)
1.6 * 0.30 * 1.00 * 1.25 / 2.9 * W
TABLE 16-P - R FACTORS for NONBUILDING STRUCTURES
zone 0 logic 0.3 = 0.4 is not Zone 4 .. 1. Tanks, vessels or pressurized 2.2 2.0
spheres on braced or unbraced
legs
V_appliedu 0.304 *W_ultimate strength 5. Inverted pendulum type structures 2.2 2.0
T > 0.06 Flexible nonbuilding structure .. Cantilevered column building systems
9. Signs and billboards 3.6 2.0
V_appliedw 0.217 *W_working stress 11. All other structures not 2.9 2.0
T > 0.06 Flexible nonbuilding structure .. otherwise covered.

Non-Building Structures at Grade UBC 1634


V 0.217 *W applied

For nonbuilding structures at / or below grade


weight 60000 lbs gross weight of item
CG 240 in

M_ot 3131288 in-lbs 0.217 g * 240.00" * 60,000 lbs


bolt_brg 90 in bolt to bearing to resist overturning

CG_rt 30.00 in arm in plan view to cg of gross weight


M_rt 1530000 in-lbs 0.85 * 60,000 lbs* 30.00 in row 190
2/3 OVERALL HEIGHT
Bolts t 2 per UBC 1630.2.2 for
tension 8896 lbs ( 3,131,288 - 1,530,000 ) in-lbs / 90.00 in / 2 bolts FLEXIBLE NON-BUILDING
STRUCTURES
Bolts v 4
shear 3262 lbs 0.217 * 60,000 lbs / 4 bolts
20.00 ft

row 200

Figure 38-1 FLEXIBLE STRUCTURE

#REF!