Anchor Handling Tug Pre-Mobilization Checklist

NAME OF VESSEL: OWNER:

CAPTAIN'S NAME: NO. CREW: MANNING CAPACITY:

Client SUPVS.:
INSPECTION DATE: PASSENGER CAPACITY:

INSPECTED BY:

CHECKLIST Control No RECEIVED BY CONTRACTOR:

INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS


1. CERTIFICATES / PERMITS
Classification Society (ABS,BV, etc.)

Cabotage Waviers

Safety Equipment Certificate

Loadline Certificate

Nigerian Survey Certificate

Liferaft Inspection Certificate

Derat Exemption Certificate

Fire Extinguisher Service Certificate

Fixed Fire Extinguisher Certificates

Permit to Work

Crane Certificates (Annual)

2. GENERAL SAFETY / LIFESAVING

Lifejackets (Type 1 PFD), Adequate?

All personnel on board can swim? Have swim


certificate?

PPE- per CNL Safe Practices manual

Workvests (Type V PFD)

Liferings / buoys, ropes & lights

Liferafts, Inflatable & floatation devices.

Safety meetings held & recorded

CNL INspector: 457260892.xls


Sheet 1 of 8 01/28/2020
11:40:24
Contractor Rep:
INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS
Fire & Emergency Drills held & recorded

Caution signs posted? (eg No Smoking, Ear


protection.)

First Aid Kit.

First Aid & CPR trained Crew

Pyrotechnics, condition & validity.

Gangway condition

3. GENERAL ITEMS
Engine Room Escape

Accommodation Escape Route

Condition of Watertight Doors

Engine Room & Accom.vent flaps

Stretcher / Litter

General Outlook-corrosion, cleanliness etc


(handrail, grating etc).
Storage of dangerous items eg paint, petrol, etc.

Emergency Lighting

Deck lighting

No leaks in the hull and below deck piping

Bilge pumps (main and spare) are functional.

Mooring Lines, No. & condition

Hull and bilge free of oil, diesel or other


hydrocarbons
Pumps/piping available to transfer fuel & potable
water to other vessels?

Approved vessel towing procedure is available


onboard the vessel.

Towing equipment specified in approved towing


procedure is available, has been inspected and
confirmed to be in acceptable condition.

4. FIREFIGHTING EQUIPMENT
Fire Extinguishers No. & type.Last serviced

Sprinkler Systems

Fire Monitors

Fire Hoses & nozzles

Fire Hydrants

CNL INspector: 457260892.xls


Sheet 2 of 8 01/28/2020
11:40:24
Contractor Rep:
INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS
Fire Pumps and Fire Water Piping

Fire buckets & sand boxes

Fire Axes

General Alarm

Fixed smothering system (CO2, Halon, etc.)

International ship / shore connection for vsl over


500 tons.

Smoke detectors

5. HOUSEKEEPING / HYGIENE
All food handlers to be issued medical certificate
for fitness by Doctor.

Cleanliness on deck

Cleanliness of Engine room & steering room

Cleanliness of bilges

Cleanliness of Accommodation, Galley, toilets etc.

Air-conditioning adequate

Potable water condition

Infestation evident? Fumigation date.

6. OIL SPILL PREVENTION


Containment for used lube oil?

Dispersant booms / chemical?

Clean up equipment

7. CRANE SAFETY
Condition of slings, shackles etc. Certified?

Condition of Snatch Blocks and Sheaves and


certification papers of same.

Safe working capacity posted on crane

Qualified Crane operator onboard if deck crane is


available?

Anti-two-block system installed and working?

Air Tuggers in Good Condition

Come-a-Long, Turfers Load tested

8. GROUNDING
Equipment hold-down bolts not used as
grounding points

CNL INspector: 457260892.xls


Sheet 3 of 8 01/28/2020
11:40:24
Contractor Rep:
INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS
Structural frame of generator is bonded to ground
system

Structural frame of transformers are bonded to


grounding system

Circuits are bonded to the ground system

Armoured cables are bonded to the grounding


system

Package units containing electrical devices are


grounded

Structural frame of motors are bonded to ground


system

Structural frame of distribution boards are bonded


to grounding system
Structural frames of Switch Gear bonded to
grounding system
All utility services-conduits, gas, water, heating,
cooling pipes are bonded to the grounding system

Separate earth conductor run in conduit, don't rely


on conduit pipe for earth path

The main ground terminal shall be welded to the


structural steelwork of the barge

All-star points (WYE) on generators and


secondary windings of transformers used as
neutral points are grounded to deck

Where the power source is offshore, two


grounding conductors are to be bonded to the
structure. Note (Grounding cables be different
lengths)

Earth / Ground loop impedance tests shall be


done on all earthing conductors within the lighting
and power circuits. A reading of one (1) ohm is
acceptable

Is electrical system fitted with GFI (Ground Fault


Interrupter), ECLD (Earth Current Leakage
Device)

General: Check distribution boards are clearly


marked

Check all bushings, glands and lock nuts are tight

Check installation using 500 volt megger on


lighting and power circuits. A reading of 0.5 meg
ohm or above 1.0 meg ohm for power is required

PAT test of all electrical tools

Check and confirm polarity on all lighting and


power circuits

9. NAVIGATIONAL EQUIPMENT
Radar

CNL INspector: 457260892.xls


Sheet 4 of 8 01/28/2020
11:40:24
Contractor Rep:
INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS
Compass

VHF

GPS

SSB

Echo Sounder

Steering/Auto pilot

Whistle/horn

Nav/signal lights

Searchlights

Engine Controls

10. ENGINES & DECK MACHINERY

Main Engines

Guards rails for rotating equipments

Bow Thruster

Condition of Zodiac/Workboat

Alternators

Anchors

4 Point Mooring

Towing winch/wire & equipment

Tugger winch/wire

Towing Pin

Shark Jaws operating properly

Stern roller operational?

11. FUEL BARGE SAFETY


Tank hatches-Packing & securing dogs

Manifold drip trays

Save alls-scupper plugs

Sand boxes

Riser shut-off and flame arrestor

Lightening arrestor

No smoking/naked light signs

Fire Extinguishers

CNL INspector: 457260892.xls


Sheet 5 of 8 01/28/2020
11:40:24
Contractor Rep:
INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS
Gas tightness of barge

12. KITCHEN / DINING


Dining/Recreation/Reading Rooms/Offices

Are air conditions working?

Are the fly screens in good working order?

Kitchen

Any evidence of rodents or insects?

Are all pieces of equipment correctly fused?

Does electrical equipment have no exposed


wires?
Fire blanket

Are they grounded?

Do personnel know location of circuit breaker?

Kitchen Extraction Fans

Are they working?

Are they cleaned regularly and kept grease free?

Are sufficient number of fly proof bins or


containers supplied?
Is garbage collection arranged on a daily basis?

Is spraying with an insecticide on a weekly basis


being arranged?
Are kitchen toilets clean and in good order?

Are enough kitchen equipment available and kept


clean and in good order?
Are sharp implements (knives, etc.) properly
stored?
Are working surfaces and chopping boards clean
and in a safe working state?
Are the catering personnel wearing the correct
work clothes?
Cutting gloves and food handling gloves

Are the clothing clean and in good order?

13. ACCOMMODATIONS
Sleeping Quarters

Is the fire drill card on the cabin door?

Fire Extinguishers present? Visible? Tagged?

Fire Alarm available and functional?

Is the fly screen in good order?

Is the fan or air conditioner working? Are rooms


properly ventilated?

CNL INspector: 457260892.xls


Sheet 6 of 8 01/28/2020
11:40:24
Contractor Rep:
INSPECTION ITEMS ACCEPTABLE UNACCEPTABLE EXPIRE DATE REMARKS
Is the room kept clean and tidy

Is the bathroom clean and in good working order

Is the linen changed and mattresses / pillows


aired regularly
Is there any sign of cooking / eating of not
permitted
Any evidence of rodents or insects?

Sewage and waste disposal adequate?

Toxic materials properly labeled and stored?

THIS CHECKLIST DOES NOT SUPERCEED THE


REQUIREMENTS OF CNL SOPs AND THE
APPROVED PROCEDURES FOR THIS
PROJECT

CNL INspector: 457260892.xls


Sheet 7 of 8 01/28/2020
11:40:24
Contractor Rep:
CLOSEOUT ACTION ITEMS
Date: Contractor:
Vessel:

Checklist
Item Reference Action Due
# Action Item Section Owner Date Comments

CNL Inspector Initials: 01/28/2020


Sheet 8 of 8 11:40:24
Contractor Rep Initials: 457260892.xls