Вы находитесь на странице: 1из 6

Chirukhi Border Sector

PLUMBING DESIGN

Tbilisi 2019
List of Drawings Specifications

## Description UoM Quantity Note


Sewage
## Description Note 1 Plastic Sewage Pipe d-100 Linear M 35
2 Plastic Sewage Pipe d-50 Linear M 40
1 General. References. Specifications ws- 1 3 Plastic Angle a -45 d -100 Piece 12
4 Plastic Angle a -45 d -50 Piece 15
2 Floor Plan. Water Supply and Sewage Piping Network. ws- 2 5 Plastic Angle a -90 d -100 Piece 5
6 Plastic Angle a -90 d -50 Piece 12
7 Plastic T-joint a -90 d -100/ 100 Piece 7
3 Cold, Hot and Circulation Networks Scheme ws- 3 8 Plastic T-Joint a -90 d -100/ 50 Piece 2
9 Plastic T-Joint a -90 d -50/50 Piece 10
Plastic T-Joint a -45 d -100/ 100 Piece 2
4 Sewage Network Scheme ws- 4
10
11 Plastic T-Joint a -45 d -100/50 Piece 5
12 Plastic T-Joint a -45 d -50/50 Piece 6
13 Plastic Revision d -100 d -50 Piece 11
14 Plastic Plug d -100 Piece 1
15 Plastic Plug d -50 Piece 1
General Indicator Table 16 Plastic Reducer d -100/ 50 Piece 1
17 Resin Reducer d -50/32 Piece 5 Sink
Required Calculated Consumption
18 Plastic Trap d -100 Piece 2
Pressure on 19 Plastic Trap d -50 Piece 2
System Description main water 20 Plastic Angle (for Bowl) d -100 Piece 5
Note 21 Plastic Coupler d -100 Piece 9
supply line 3 3
m/day m/hour l/sec 22 Plastic Coupler d -50 Piece 10
m 12 Horizontal pipes
23 Plastic Pipe Supports Piece
24 Plastic Pipe Supports d -50 Piece 13
Potable and Facility 25 Dowel Piece 70 Vertical Pipes
15.0 0.6 0.5 0.3 Snc 1.0
Water Supply
26 Wire

Hot Water Supply 0.22 0.3 0.23


Plumbing Accessories
Sewage 0.6 0.5 1.8 1 Sink with Faucet, Syphon, two flexible hoses. L -0.4 d -15 Set 5
2 Bowl with sinking tank, flexible hose. L-0.4 m d -15 Set 4
3 Shower with Faucet, Syphon, Two flexible hoses. L-0.4 m. d -15 Set 4

Specifications

## Description UoM Quantity Note

Legend Cold and Hot Water Supplies


1 Plastic Pipe d -20 Linear m 45 (without foil)
2 Plastic Pipe d -25 Linear m 15 (without foil)
Shw Below Shower 3 d -32 7
Plastic Pipe Linear m (without foil)
Dws Dishwashing Sink 4 Plastic Pipe d -40 Linear m 40 (without foil)
5 Plastic Pipe d -20 Linear m 90 (with foil)
ps Sink
6 Plastic Pipe d -25 Linear m 20 (with foil)
Bw Bowl 7 Plastic Pipe d -32 Linear m 37 (with foil)
8 Plastic Coupler d -20 Linear m 33 horizontal pipe
t Trap 9 Plastic Coupler d -25 Linear m 8 horizontal pipe
10 Plastic Coupler d -32 pc 11 horizontal pipe
Snc Sewage network cleaning 11 Plastic Coupler d -40 10 horizontal pipe
"
12 Plastic Pipe Supports d -20 " 45 horizontal pipe
If Irrigation Faucet
13 Plastic Pipe Supports d -25 " 9 horizontal pipe
SR Sewage Riser 14 Plastic Pipe Supports d -32 " 14 horizontal pipe
15 Plastic Pipe Supports d -40 " 13 horizontal pipe
Cold Water Supply Pipe 17 Plastic Angle d -20 " 60
18 Plastic Angle d -25 " 5
Hot Water Supply Pipe Plastic Angle d -32 3
19 "
Circulation Water Pipe 20 Plastic Angle d -40 " 8
21 Plastic Angle with inner thread d -15 " 28
Sewage Pipe 22 Plastic Reducer d -25/20 " 5
23 Plastic Reducer d -32/20 " 4
24 Plastic Reducer d -32/25 " 2
25 Plastic Reducer d -40/20 " 2
26 Plastic Reducer d -40/32 " 1
27 Faucet for irrigation with resin flexible hose d -20 c 2
Notes 28 Oakum c 4
29 Plastic T-Joint d -20/20 " 20
1. Main Water Supply Pipe is to be installed on 0.8m depth from ground level. d -25/20 12
30 Plastic T-Joint "
2. Existing plumbing accessories are referenced from the Architectural part of the design. 31 Plastic T-Joint d -25/25 " 3
32 Plastic T-Joint d -32/20 " 2
3. During Installation of plumbing accessories and piping other parts of the design shall be considered 33 2
Plastic T-Joint d -32/25 "
(Architectural, HVAC, Electrical parts) 34 4
Plastic T-Joint d -40/20 "
35 Plastic T-Joint d -40/25 " 3
36 Plastic T-Joint d -40/32 " 1
37 Wire Kg 2
38 Dowel Pc 100
39 Angle Valve d -15 9
General Reference 40 Plastic Valve d -20 12
41 Plastic Valve d -25 2
Present design considers provision of cold, hot water supplies and sewage to the designed building. 42 Plastic Valve d -32 2
Piping for cold, hot and circulation water shall be buried in floor screed. 43 Plastic Valve d -40 1
For Kennel washing purposes faucet will be installed on boiler room outside wall.
Plastic pipes without foil are to be used for cold water supply, and polypropylene pipes PN 10 with foil for hot water supply.
Network has a check points on 1.0 m height from floor level. Director Parsons Scale N/A 2019
Piping for cold, hot and circulation water shall have locks and protective fixtures in order to turn off piping by sectors during damages.
Ventilation pipes are to be installed on 0.3 level above roof cover. Author Stage Sheet Sheets
Plumbing works shall be implemented in accordance to used safety regulations. Chirukhi border sector
Engineer Critical WS-1 4

Cheked by
General. References. Specifications
Floor Plan

Incoming Water Line 1


d-40

Snc-5
Cold Water pipe to Boiler
Bw-1 d-20 t-4
d-100
From Boiler
d-32
Bw-2 To Boiler
Shw-4
Bw-4 d-20

Bw-3 If-1
ps-1 ps-2 Snc-4

Snc-1 t-3
ps-5 d-50

ps-3 ps-4
Snc-2

water outlet
for washer

If-2

Dws-1
t-2
d-100 SR-2
d-50
SR-1
d-100 Shw-1 Shw-2 Shw-3
Snc-6

Snc-3
Outgoing Sewage Pipe 3
Outgoing Sewage Pipe 2 d-50
Outgoing Sewage Pipe 1 d-100
d-100

Director Parsons Scale 1:100 2019


Author Stage Sheet Sheets
Chirukhi border sector
Engineer Critical WS-2 4

Cheked by Floor Plan. Water Supply and


Sewage Piping Network.
Outside WC
Bw-1

d-20
Bw-2

d-20
ps-6
20
d- Cold, Hot and Circulation Networks Scheme To Boiler
ps-7 d-20
From Boiler
d-32
To Boiler
d-20

If-1 Shw-4
d-20
d-20

ps-5
Bw-4
d-20

d-20

d-25
20
d- 25 d-20 2.10
d-

d-40 d-40
d-32 d-20
d-20 d-20

Bw-1 20 0
2

d-
d- -40

d-20
-2.6 (root cellar) d
Bw-2
20
d-20

d- d-40
ps-1
ps-2 Incoming Water Line 1
d-20

Bw-3
d-20
d-20

20 Dws-1
d-

d-20
d-32
d-25

32
d-

20
d-
d-20

ps-4
25
d-
d-20
d-20

20
d-
d-20

d-20 ps-3

25
d- 20
If-1
d-

Shw-1 d-25 d-20


d-20

d-20

d-20

Shw-2 Shw-3
Director Parsons Scale N/A 2019
Author Stage Sheet Sheets
Chirukhi border sector
Engineer Critical WS-3 4

Cheked by
Cold, Hot and Circulation Networks Scheme
0
2.2

SR-1
d-100 Outgoing Sewer Line
) d-100
el.
ev
0 ndL
0.0 ou
Bw-1 ( Gr
ps-6 00
-1. 0
10
ps-1 ps-2 Bw-2 0 d- Sewage Network Scheme
10 02
ps-7 d- 0.
Bw-3 02 t-1
0. d-50
t-3
0 Shw-4 d-50
d-50 Snc-1
0.03 -1.7 Outgoing Sewer Line 3
d-50
Bw-4 Snc-4
d-100 d-50
0.02 l)
0.03 eve
ps-5 50 SR-2 0 n dL
d- .0 ou
Snc-2 ps-3 ps-4 d-50 Snc-6 0 Gr
0 0(
-1.
0 50
2.2 d-
00 d-50 03
1 0.
d- 0.03
.02
0 0
50 -1.7
d-
03
t-2 0.
0
Snc-3 10
0 d-100 0.0
d- .02 Bw-1
0
0.02
Shw-1 Shw-2 Shw-3 Outgoing Sewer Line 2
d-100
d-50 d-50 ve
l) 50
e d-
0.03 0 dL 03
0.0
n 0.
G rou Dws-1
Snc-5 0(
0
t-3 -1. 0
d-100 10
d-
0 2
0.

70
-1.

Director Parsons Scale N/A 2019


Author Stage Sheet Sheets
Chirukhi border sector
Engineer Critical WS-4 4

Cheked by
Sewage Network Scheme
PAGE FORMAT
FILE NAME furclis formati
failis saxeli
ISO expand A3 (297.00 x 420.00 MM)
DWG PROCESSING DATE
damuSavebis TariRi 03.11.2019

SYMBOLS
ROOT CELLAR simboloebi

1. Pump 2t/40m
2. Cold water reservoir
∅20 ∅32
∅32 3. Sub pump
4. Expansion tank 35 lt.
∅20 ∅20
∅32 ∅32
∅20 ∅20

ball valve
∅32
mechanical filter

∅32 back-flow valve

cold water pipe


discharge pipe

WATER SUPPLY PIPE ∅32 ∅32


sludge filter

∅50 ∅32 ∅20 to the sub pump


∅20 micron filter

UV light filter

GENERAL NOTES:
SeniSvnebi

This drawing shows the water supply scheme


for the building.
Water is collected from water supply pipe,
located on sector site. The building premises are
supplied with water using a water pump.
The well is connected to two 2 m 3plastic
tanks, located in the HQ building root cellar,
using PVC pipes of 50 mm diameter, with
insulation of 30 mm (to withstand freezing
temperatures) through the channel installed at
the depth of 60 cm (or more) under the surface
level. Design organization: LTD "Mapservice" ID 406158991

POSITION NAME SIGNATURE


Tanamdeboba saxeli xelmowera
DIRECTOR
direqtori I.Jashiashvili
AUTHOR
avtori M.Bulalauri

CHECKED
Seamowma
I.Jashiashvili

DRAWING NAME:
dasaxeleba:

Water supply scheme

SCALE LAYOUT SHEETS


masStabi gverdi furclebi

WSS-1 1