Вы находитесь на странице: 1из 33

Information

Description of Output Data

P30304-E0731-K170-1-7617

File Description for Postprocessing


Trunk Group Measurement Data
Trunk Group Measurement Data Description of Output Data

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given “as is” and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,
DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT
NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR
THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009. All rights reserved.

2 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

Table of Contents

0 General Information 4
0.1 Glossary and Abbreviations...............................................................................4
0.2 Keyword/Descriptor ............................................................................................5
0.3 List of Figures and Tables ..................................................................................5

1 Introduction 6
1.1 Delimitation..........................................................................................................6

2 File Format Description 7


2.1 File names............................................................................................................7

3 Remarks on File Contents 8


3.1 Postprocessing State..........................................................................................8
3.2 Common remarks on the data records..............................................................8
3.3 Data Quality and Availability ..............................................................................8
3.3.1 Data Quality ...........................................................................................................................8
3.3.2 Availability .............................................................................................................................9
3.4 Measurement specific hints ...............................................................................9
3.4.1 Number of measurement objects ......................................................................................10
3.5 Header Record [also for Project DTAG] .......................................................... 10

4 Record Format Description 11


4.1 Data Record: REC TGRP................................................................................... 11
4.2 Overview of the used Indices ........................................................................... 12
4.3 Data dependent of the index ............................................................................ 13

5 Field Description 18
5.1 Counter overview .............................................................................................. 18
5.2 Common REC TGRP Data................................................................................. 21
5.3 Data dependent of the index ............................................................................ 22

6 Operating Instructions 32
6.1 File Sizes ............................................................................................................ 32

7 Examples 33

P30304-E0731-K170-1-7617 3
Trunk Group Measurement Data Description of Output Data

0 General Information

0.1 Glossary and Abbreviations


APS Application program system
BEV preempted traffic (bevorrechtigter Verkehr)
BICC Bearer Independent Call Control
BIS Bearer Independent Signaling
BW Bothway
CC Calls carried
CCNC Common channel signaling network control
CCS Calls carried successful
CCS7 Common channel signaling system No. 7
CCU Calls carried unsuccessful
CHR Channel register
CML Command manual
COC Cross office check
CP Coordination processor
CUG Closed user group
DCP Data communication processor
DSS1 Digital signaling system no.1
DTAG Deutsche Telekom AG
ERL Erlang
GP Group processor
IC Incoming
IKA International gateway exchange (Internationales Kopfamt)
ISDN Integrated services digital network
ISUP ISDN signaling user part
LTG Line trunk group
MDD Magnetic disk device
MG Media gateway
MGC Media gateway controller
MLPP Multi level precedence and preemption
MML Man machine language
MOD Magneto optical disk device
MTD Magnetic tape device
NH Non hierarchical
NM Network management
NTM Network traffic management
OG Outgoing
OMT Operation & maintenance terminal
PAM Primary access method
REC Record
RSU Remote switching unit
SN Switching network
SPC Signaling point code
SS Subsystem
TC Traffic carried
TGRP Trunk group
TUP Telephony user part
TV Traffic volume

4 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

0.2 Keyword/Descriptor
File Description
Postprocessing
Traffic Measurement
Traffic Data Recording
Traffic Data Administration
Recording of TGRP Traffic Measurement Data
REC TGRP

0.3 List of Figures and Tables


Error! No table of figures entries found.
Table 3: Measurement ..................................................................................................................6
Table 4: Allocation of measurement, measurement type and command number .........................7
Table 5: File name.........................................................................................................................7
Table 6: Variant and Version.........................................................................................................8
Table 7: Data Quality.....................................................................................................................8
Table 8: Data Availability...............................................................................................................9
Table 9: Number of measurement objects ..................................................................................10
Table 10: Overview of Indices .....................................................................................................12
Table 11: Assignment of FORMAT parameter values to counter blocks ....................................18
Table 12: Counter overview and counter provision part 1...........................................................19
Table 13: Counter overview and counter provision part 2...........................................................20
Table 14: Characteristic file sizes, MDD/Postprocessing............................................................32

P30304-E0731-K170-1-7617 5
Trunk Group Measurement Data Description of Output Data

1 Introduction
This file description shall be used as basic information for the design of postprocessing tools for
the traffic measurement files of the traffic data recording functions.

Data from the following measurement are applied:


Subsystem TS
Measurement Recording of traffic data for:
REC TGRP Trunk groups

Table 1: Measurement

1.1 Delimitation
In this document the specifications for recording of the traffic data are only described for REC
TGRP measurements. The general processes and conditions to process the data, collected by
traffic measurement (header records, common parts), are described in Error! Reference
source not found..

6 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

2 File Format Description


The general file format is described in Error! Reference source not found.. The following
statements apply to recording of traffic measurement data of trunk groups.
Subsystem TS
Measurement Measurement type Command number
REC TGRP TGRP 291

Table 2: Allocation of measurement, measurement type and command number

2.1 File names


The file name is built with the measurement type identifier (see: Table 2: Allocation of
measurement, measurement type and command number). The file names of the REC TGRP
measurement follow the general name convention, see Error! Reference source not found..
Subsystem TS
Measurement File name
REC TGRP TS.TGRP.<suffix>

Table 3: File name

P30304-E0731-K170-1-7617 7
Trunk Group Measurement Data Description of Output Data

3 Remarks on File Contents

3.1 Postprocessing State

Subsystem TS
Measurement Variant Version Remarks
REC TGRP A3 50 Version number 50 remains unchanged for hiQ 9200
V6. There are no newly defined output fields. Only the
interpretation of the field ‘OPMODE/TGRPTYP’ has
changed in case of values ‘K’ and ‘L’ (see 3.4
Measurement specific hints).

Table 4: Variant and Version

3.2 Common remarks on the data records

If in a measurement order several objects are recorded, its number will remain constant. After
deletion of a recorded object, default values are output for this object.
In case of measurement of all trunk groups, a data output will be done for each trunk group
which is created, provided that its data are available at the moment of data reading.

Further general description of the data records see Error! Reference source not found..

3.3 Data Quality and Availability


Up to 3 data quality signs may be output in the same mask. In the traffic measurement files of
REC TGRP measurement, the signs are used as follows.

3.3.1 Data Quality

Value Meaning Remark


0 default Default value
1 SECURE Data of this cycle are secure
2 TIME CORR During this cycle the system time was modified
(MML-command: MOD TIME)
3 NO INIT Traffic measurement counters could not be initialized at the
previous stroke. Therefore, the output data are insecure for
the actual cycle.
4 INCMPL SUM unused

Table 5: Data Quality

8 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

3.3.2 Availability

Value Meaning Remark


Blank default Default value, for internal use only
1 AVAILABLE The traffic measurement data are available.
2 DEL Object (trunk group) deleted
3 NONE No data available for this measurement object (i.e. no data
from traffic data server)

Table 6: Data Availability

3.4 Measurement specific hints


To each trunk group an operation mode (OPMODE) with following values is assigned:

IC - incoming
OG - outgoing
BW - bothway

To each trunk group a trunk group type is assigned, REC TGRP uses following values:

STD - Standard trunk group


IF - Interface trunk group (RSU-specific, opmode bothway)
SD - Sidedoor trunk group (RSU-specific, opmode bothway)
MG - Media Gateway TGRP (MG-specific, opmode incoming or bothway)
BIS - Bearer independent signaling TGRP (MGC/BICC/ISUP+ or SIP/SIP-T, opmode
incoming or bothway)

In data output for postprocessing, a combination of both values is constructed:

I - opmode IC, trunk group type STD


O - opmode OG, trunk group type STD
B - opmode BW, trunk group type STD
F - opmode BW, trunk group type IF
S - opmode BW, trunk group type SD
G - opmode BW, trunk group type MG
H - opmode IC, trunk group type MG
K - opmode BW, trunk group type BIS
L - opmode IC, trunk group type BIS

For data output control (quantity of the data) an additional trunk group sign is used. This sign
shows specific properties of the trunk group. See ‘Identifier’ in Table 10: Counter overview and
counter provision part 1 and Table 11: Counter overview and counter provision part 2 in chapter
5.1, Counter overview.
Example: NH for a NH-specific TGRP or CCS7 for a TGRP with CCS7-Signalling.

The data structures for trunk groups are prepared for trunk groups with opmode bothway. Data
fields which are not used for the current opmode, trunk group type or trunk group sign remain
unused, filled with spaces.

P30304-E0731-K170-1-7617 9
Trunk Group Measurement Data Description of Output Data

The traffic counters for RSU-specific Interface- (IF) respectively Sidedoor- (SD) trunk groups are
not distinguished between incoming (IC) and outgoing (OG) traffic. The counters for outgoing
(OG) traffic contain the total incoming and outgoing traffic; the counters for incoming traffic
remain unused with default values.

All counters corresponding to their opmode (IC or BW) for bearer independent signaling (BIS )
trunk groups, Media Gateway Controller (MGC/BICC/ISUP+), Session Initiation Protocol (SIP)
or SIP for Telephones (SIP-T) TGRPs are output. There is no special handling for these trunk
group types.

3.4.1 Number of measurement objects

The subsequently listed table shows as an overview


- the process incarnations of data recording function (REC TGRP)
as well as the connection between measurement and
- maximum number of objects per data record and
- maximum number of objects per task,
and additional
- the maximum number of objects, which may be recorded,
- the maximum number of objects in the system (the exchange).

Subsystem TS
Measurement REC- Max. number of objects
incarna- per data per to be in the
tions record (1) task recorded system
REC TGRP (1) 8 3...28 4095 4095 4095

Table 7: Number of measurement objects

(1) With selection by the FORMAT-parameter as well as project or trunk group type specific, it
is possible that only a part of the counters will be filled into a data record. So the number of
trunk groups in a data record is variable.

It is possible that more than one data record will be written. The maximum size of a record after
reformatting for postprocessing is 2044 Bytes. All data parts for a trunk group are written in the
same data record.

Example:
An order (REC TGRP) is started to record 10 trunk groups (measurement objects), it is not
possible to make an output with a single data record for all trunk groups. So 3 data records will
be output every 15 minutes, the first and the second record contain 4 trunk groups each, the
third record contains 2 trunk groups.

3.5 Header Record [also for Project DTAG]


The header record is described in Error! Reference source not found.

10 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

4 Record Format Description

4.1 Data Record: REC TGRP

Field Byte Length Field name Align- Remarks


no. position ment
l=left,
r=right
1 1-4 4 RECORD LENGTH -
2 5 - 12 8 DATE year - 00 - 99
- "-"
month 01 - 12
- "-"
day 01 - 31
3 13 - 17 5 TIME hour - 00 - 23
: ":"
minute 00 - 59
4 18 - 20 3 DATA QUALITY l blank = Default
n[n[n]] 1 = SECURE
2 = TIME CORR
3 = NO INIT
5 21 - 23 3 Variable record part length r 72
1)
6 24 1 Index - 1 ... 8
7 25 - 30 6 TGNO l 6 characters 1)
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
1)
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
1)
3 = NONE
1,2)
10 33 - 39 7 Counter 1 r
1,2)
11 40 - 46 7 Counter 2 r
1,2)
12 47 - 53 7 Counter 3 r
1,2)
13 54 - 60 7 Counter 4 r
1,2)
14 61 - 67 7 Counter 5 r
1,2)
15 68 - 74 7 Counter 6 r
1,2)
16 75 - 81 7 Counter 7 r
1,2)
17 82 - 88 7 Counter 8 r
1,2)
18 89 - 95 7 Counter 9 r

1) Coherent data part, n-times repeated


2) Content of this field is dependent from Index (Field no. 6)

P30304-E0731-K170-1-7617 11
Trunk Group Measurement Data Description of Output Data

4.2 Overview of the used Indices

Data may be output for subsequently listed indices:

Index Counter content


1 Common call and volume counters, project specific counters
2 additional trunk group data and trunk group counters
3 Calls carried successful (CCS) counters
4 Calls carried unsuccessful (CCU) counter, QOS-counter
5 CCS7-specific counters
6 NH-specific counters (direct- and 1st alternative route)
7 NH-specific counters (2nd alternative route)
8 MLPP-specific counters
Table 8: Overview of Indices
By selection with the FORMAT parameter of the REC TGRP command as well as project-
and/or trunk group specific, the data output may contain only a partial set of the possible
counters.
MDD data output contains only counters which were selected by FORMAT, and/or those
counters which are valid for the particular trunk group type, trunk group sign, project and
operation mode. As a result, some data segments (indices) may be missing completely.
However, at least one data segment (index) is put out for a selected trunk group even if all
counters of this segment show the default value (e.g. because the trunk group was deleted). In
case of measurement of all trunk groups, no data for deleted trunk groups will be written on
MDD.

By modification of the trunk group data (e.g. operation mode, trunk group sign, trunk group type)
during active traffic measurement, the number of the data segments written on MDD can
change at any time. This affects the file size calculation as well as the used space of the current
measurement file which must be extended dynamically.

12 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

4.3 Data dependent of the index

- Data segment: REC TGRP [Index=1]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 1
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1,2)
10 33 - 39 7 CC: I r
1,2)
11 40 - 46 7 TV: I (ERLS) r
1,2)
12 47 - 53 7 CCS WITH ANSWER: I r
1,2)
13 54 - 60 7 TV ANSWER: I (ERLS) r
1,3)
14 61 - 67 7 CC: O r
1,3)
15 68 - 74 7 TV: O (ERLS) r
1,3)
16 75 - 81 7 CCS WITH ANSWER: O r
1,3)
17 82 - 88 7 TV ANSWER: O (ERLS) r
1,4)
18 89 - 95 7 PROJECT SPECIFIC r

1) Default value: blank


2) Only provided for operating mode IC, BW; else for OG: Default value
3) Only provided for operating mode OG, BW; else for IC: Default value
4) Project specific definition and implementation

P30304-E0731-K170-1-7617 13
Trunk Group Measurement Data Description of Output Data

- Data segment: REC TGRP [Index=2]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 2
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1)
10 33 - 39 7 CONNECTED LINES r
1)
11 40 - 46 7 NO OF BLO LINES (ERL) r
1)
12 47 - 53 7 SEMI BLOCKED LINES r
1)
13 54 - 60 7 TRANS BLOCKED LINES r
1)
14 61 - 67 7 TV SEMI BLOLI (ERLS) r
1)
15 68 - 74 7 TV TRANS BLOLI (ERLS) r
1,3)
16 75 - 81 7 TGRP BLO TIME: O (SEC) r
1,3)
17 82 - 88 7 ATB TIME (SEC) r
1,3)
18 89 - 95 7 NUMBER OF ATB r

1) Default value: blank


3) Only provided for operating mode OG, BW; else for IC: Default value

- Data segment: REC TGRP [Index=3]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 3
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1,3)
10 33 - 39 7 CCS CONGESTION r
1,3)
11 40 - 46 7 CCS INCMP DIAL r
1,3)
12 47 - 53 7 CCS UNALL NUM r
1,3)
13 54 - 60 7 CCS RELORIG ENDTOEND r
1,3)
14 61 - 67 7 CCS SUB BUSY r
1,3)
15 68 - 74 7 CCS INT TECHN IRREG r
1,3)
16 75 - 81 7 CCS EXT TECHN IRREG r
1,3)
17 82 - 88 7 CCS UNANSWERED r
1)
18 89 - 95 7 unused r

1) Default value: blank


3) Only provided for operating mode OG, BW; else for IC: Default value

14 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

- Data segment: REC TGRP [Index=4]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 4
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1,3)
10 33 - 39 7 CCU SUM OFL/LOSS r
1,3)
11 40 - 46 7 CCU LOST CALLS r
1,3)
12 47 - 53 7 CCU NM TGRP BLOCKING r
1,3)
13 54 - 60 7 CCU TECHN IRREGULAR r
1,3)
14 61 - 67 7 CCU TGRP BLOCKED r
1,3)
15 68 - 74 7 CCU TRUNKRESERVATION r
1,3)
16 75 - 81 7 CCU ALL TRUNKS BUSY r
1)
17 82 - 88 7 QOS TRAFFIC CONTROL r
1)
18 89 - 95 7 unused r

1) Default value: blank


3) Only provided for operating mode OG, BW; else for IC: Default value

- Data segment: REC TGRP [Index=5]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 5
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1) 4)
10 33 - 39 7 NUMB CCS7 DPC OLOAD r
1) 4)
11 40 - 46 7 CCS7 DPC OLOAD (SEC) r
1) 4)
12 47 - 53 7 CCS CCS7 NORM UNSPEC r
1) 4)
13 54 - 60 7 CCU CCS7 CCNC OLOAD r
1) 4)
14 61 - 67 7 CCU CCS7 DPC OLOAD r
1) 4)
15 68 - 74 7 CCU CCS7 DPC OL ACC r
1)
16 75 - 81 7 unused r
1)
17 82 - 88 7 unused r
1)
18 89 - 95 7 unused r

1) Default value: blank


4) Only provided for trunk groups with operating mode OG or BW and CCS7-signalling;
else: Default value

P30304-E0731-K170-1-7617 15
Trunk Group Measurement Data Description of Output Data

- Data segment: REC TGRP [Index=6]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 6
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1,5)
10 33 - 39 7 CC NH DIRECT:O r
1,5)
11 40 - 46 7 TV NH DIRECT:O (ERLS) r
1,5)
12 47 - 53 7 CCS NH DIRECT ANSW:O r
1,5)
13 54 - 60 7 CCU NH DIRECT OFL r
1,5)
14 61 - 67 7 CC NH ALT1:O r
1,5)
15 68 - 74 7 TV NH ALT1:O (ERLS) r
1,5)
16 75 - 81 7 CCS NH ALT1 ANSW:O r
1,5)
17 82 - 88 7 CC NH ALT1 REROUTING r
1,5)
18 89 - 95 7 CCU NH ALT1 LOST r

1) Default value: blank


5) Only provided for non hierarchical trunk groups (NH-TGRP) with operating mode OG or BW;
else: Default value

- Data segment: REC TGRP [Index=7]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 7
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1,5)
10 33 - 39 7 CC NH ALT2:O r
1,5)
11 40 - 46 7 TV NH ALT2:O (ERLS) r
1,5)
12 47 - 53 7 CCS NH ALT2 ANSW:O r
1,5)
13 54 - 60 7 CCU NH ALT2 r
1)
14 61 - 67 7 unused r
1)
15 68 - 74 7 unused r
1)
16 75 - 81 7 unused r
1)
17 82 - 88 7 unused r
1)
18 89 - 95 7 unused r

1) Default value: blank


5) Only provided for non hierarchical trunk groups (NH-TGRP) with operating mode OG or BW;
else: Default value

16 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

- Data segment: REC TGRP [Index=8]

Field Byte Length Field name Align- Remarks


no. position ment
6 24 1 Index - 8
7 25 - 30 6 TGNO l 6 characters
8 31 1 OPMODE/TGRPTYP - blank/B/I/O/F/S/
G/H/K/L
9 32 1 AVAILABILITY - blank = Default
1 = AVAILABLE
2 = DEL
3 = NONE
1)
10 33 - 39 7 CC PRECEDENCE:I r
1)
11 40 - 46 7 CC PRECEDENCE:O r
1)
12 47 - 53 7 CC PREEMPTED:I r
1)
13 54 - 60 7 CC PREEMPTED:O r
1)
14 61 - 67 7 unused r
1)
15 68 - 74 7 unused r
1)
16 75 - 81 7 unused r
1)
17 82 - 88 7 unused r
1)
18 89 - 95 7 unused r

1) Default value: blank

P30304-E0731-K170-1-7617 17
Trunk Group Measurement Data Description of Output Data

5 Field Description

5.1 Counter overview

Counter for REC TGRP


A list of counter names (MDD output) as well as counter provision dependent of the operating
mode of the trunk group, the trunk group type, the trunk group sign and the project (country
code of the exchange) is listed in Table 10: Counter overview and counter provision part 1 and
Table 11: Counter overview and counter provision part 2.

Explanation of the marks:


(+: provided, -: not provided, *: true).

OPMODE and TGRPTYPE see chapter 3.4, Measurement specific hints

Explanation of the Identifier:


CCS7 : CCS7-specific Counter
NH : NH-specific Counter
SEMI : Counter is read out from semi-permanent trunk group database
SEL : specific selection of common counters
MLPP : MLPP-specific counter, selection should be done in MLPP-APS's
Rem : Output of these counter with the respective mark (1 or 2) may be
depending on the project suppressed

Ind - Counter blocks (Data control index which applies to the counter):
Data output is restricted to selective counter blocks corresponding to the entered FORMAT
parameter values with command REC TGRP. Assignment see: Table 9: Assignment of
FORMAT parameter values to counter blocks.

FORMAT = Assignment
No input all counters
ALL all counters
COMLONG all counter of Ind = 1 and Ind = 2
COMSHORT Counter package (see Identifier SEL)
(Part of the counter of Ind = 1 and Ind = 2)
UNSUCC all counter of Ind = 3 and Ind = 4
CCS7 all counter of Ind = 5
NH all counter of Ind = 6 and Ind = 7
MLPP all counter of Ind = 8
Combination of the values result in the total sum of the selected counters, e.g.
COMLONG and COMSHORT are all counters of Ind=1 and Ind=2 (equal with
COMLONG).
Table 9: Assignment of FORMAT parameter values to counter blocks

18 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

Ind Counter name OPMODE TGRPTYP Identifier


IC OG BW IF SD CCS7 NH SEMI SEL MLPP REM
1 CC:I + - + - - *
1 TV:I (ERLS) + - + - - *
1 CCS WITH ANSWER:I + - + - - *
1 TV ANSWER:I (ERLS) + - + - - * 1
1 CC:O - + + + + *
1 TV:O (ERLS) - + + + + *
1 CCS WITH ANSWER:O - + + - - *
1 TV ANSWER:O (ERLS) - + + - - * 1
1 PROJECT SPECIFIC + + + - -
2 CONNECTED LINES + + + + + * *
2 NO OF BLO LINES (ERL) + + + + + *
2 SEMI BLOCKED LINES + + + + + * *
2 TRANS BLOCKED LINES + + + + + *
2 TV SEMI BLOLI (ERLS) + + + + +
2 TV TRANS BLOLI (ERLS) + + + + +
2 TGRP BLO TIME:O (SEC) - + + + +
2 ATB TIME (SEC) - + + + +
2 NUMBER OF ATB - + + + +
3 CCS CONGESTION - + + - -
3 CCS INCMP DIAL - + + - -
3 CCS UNALL NUM - + + - -
3 CCS RELORIG ENDTOEND - + + - -
3 CCS SUB BUSY - + + - -
3 CCS INT TECHN IRREG - + + - -
3 CCS EXT TECHN IRREG - + + - -
3 CCS UNANSWERED - + + - -
4 CCU SUM OFL/LOSS - + + - -
4 CCU LOST CALLS - + + - -
4 CCU NM TGRP BLOCKING - + + - -
4 CCU TECHN IRREGULAR - + + - -
4 CCU TGRP BLOCKED - + + - -
4 CCU TRUNKRESERVATION - + + - -
4 CCU ALL TRUNKS BUSY - + + + +
4 QOS TRAFFIC CONTROL + + + - -
5 NUMB CCS7 DPC OLOAD - + + - - *
5 CCS7 DPC OLOAD (SEC) - + + - - *
5 CCS CCS7 NORM UNSPEC - + + - - *
5 CCU CCS7 CCNC OLOAD - + + - - *
5 CCU CCS7 DPC OLOAD - + + - - *
5 CCU CCS7 DPC OL ACC - + + - - *
6 CC NH DIRECT:O - + + - - * 2
6 TV NH DIRECT:O (ERLS) - + + - - * 2
6 CCS NH DIRECT ANSW:O - + + - - * 2
6 CCU NH DIRECT OFL - + + - - * 2
6 CC NH ALT1:O - + + - - * 2
6 TV NH ALT1:O (ERLS) - + + - - * 2
6 CCS NH ALT1 ANSW:O - + + - - * 2
6 CC NH ALT1 REROUTING - + + - - * 2
6 CCU NH ALT1 LOST - + + - - * 2

Table 10: Counter overview and counter provision part 1

P30304-E0731-K170-1-7617 19
Trunk Group Measurement Data Description of Output Data

Ind Counter name OPMODE TGRPTYP Identifier


IC OG BW IF SD CCS7 NH SEMI SEL MLPP REM
7 CC NH ALT2:O - + + - - * 2
7 TV NH ALT2:O (ERLS) - + + - - * 2
7 CCS NH ALT2 ANSW:O - + + - - * 2
7 CCU NH ALT2 - + + - - * 2
8 CC PRECEDENCE:I + - + - - *
8 CC PRECEDENCE:O - + + + + *
8 CC PREEMPTED:I + - + - - *
8 CC PREEMPTED:O - + + + + *
Table 11: Counter overview and counter provision part 2

20 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

5.2 Common REC TGRP Data

Field Field name Description


no.
1 RECORD LENGTH Length of the output record
2 DATE Current date of the data record
3 TIME Current 15-minute-time of the data record
4 DATA QUALITY Information about causes of a traffic data corruption:
0 = default Default
1= SECURE: Data are secure
2= TIME_CORR: Time change during the current cycle
3= NO_INIT: missing Initialization
5 Variable record part Length of one data segment, which is assigned to an index
length (always 72 bytes)
6 Index Data control index
characterizes the kind of the following data
7 TGNO Trunk group number
8 OPMODE/ Operating mode / trunk group type
TGRPTYP : Default (this is the initialized value)
B : bothway (BW)
I : incoming (IC)
O : outgoing (OG)
F : bothway Interface TGRP (BW/IF)
S : bothway Sidedoor TGRP (BW/SD)
G : bothway Media Gateway TGRP (BW/MG)
H : incoming Media Gateway TGRP (IC/MG)
K : bothway Bearer Independent Signaling TGRP
(BW/BIS)
L : incoming Bearer Independent Signaling TGRP (IC/BIS)
9 AVAILABILITY Availability of the data
blank = default
1 = Data available
2 = Object deleted
3 = Data not available
10 - 18 Data dependent of index (Field-No. 6); see subsequently listed
data field descriptions

P30304-E0731-K170-1-7617 21
Trunk Group Measurement Data Description of Output Data

5.3 Data dependent of the index

- Data segment: REC TGRP [Index=1]

Field Field name Description


no.
10 CC:I Number of accepted call attempts in the CP in the incoming
traffic (A-side TGRP)
11 TV:I (ERLS) Sum of the holding times in incoming traffic (A-side TGRP)
Unit = Erlang-seconds
12 CCS WITH Number of successful answered calls at the called station for
ANSWER:I incoming traffic (A-side TGRP).
13 TV ANSWER:I Duration of answered calls in incoming traffic (A-side TGRP)
(ERLS) Unit = Erlang-seconds
14 CC:O Number of calls carried by the TGRP in outgoing traffic (TGRP
is seized in CP database and SN is connected through)
15 TV:O (ERLS) Sum of the seizing times of the TGRP for outgoing traffic.
(TGRP is seized in CP database and SN is connected through)
Unit = Erlang-seconds
16 CCS WITH Number of successful answered calls at the called station for
ANSWER:O outgoing traffic (B-side TGRP).
17 TV ANSWER:O Duration of answered calls in outgoing traffic (B-side TGRP)
(ERLS) Unit = Erlang-seconds
18 PROJECT used for project specific adaptation
SPECIFIC

22 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

- Data segment: REC TGRP [Index=2]

Field Field name Description


no.
10 CONNECTED Number of connected trunks. For BW - TGRP this represents
LINES the total number of trunks created for incoming and outgoing
traffic. It is the actual value at the end of the integration interval.
11 NO OF BLO Average Number of blocked lines.
LINES (ERL) Unit = Erlang (ERL)
(The only one counter in REC TGRP measurement file provided
in Erlang instead of Erlang-seconds)
12 SEMI BLOCKED Number of semipermanent blocked trunks for O&M reasons. It
LINES is the actual value at the end of the integration interval.
13 TRANS BLOCKED Number of transient blocked trunks. It is the actual value at the
LINES end of the integration interval.
14 TV SEMI BLOLI Total maintenance-related blocking time due to semipermanent
(ERLS) trunk blocking.
Unit = Erlang-seconds
15 TV TRANS BLOLI Total blocking time of transient blocked trunks.
(ERLS) Unit = Erlang-seconds
16 TGRP BLO TIME:O Total transient and semipermanent blocking time of the TGRP
(SEC) in its entity for outgoing traffic (e.g. via ENTR TGDAT:BLK=
ADMIN,..). During this blocking period a bothway trunk group
can accept incoming calls.
Unit = Seconds
17 ATB TIME (SEC) Total 'All Trunks Busy time' in outgoing traffic or , for BW
TGRPs, in incoming and outgoing traffic.
[ATB = There is no idle trunk for call processing]
Unit = Seconds
18 NUMBER OF ATB Number of entries into the 'All Trunks Busy' state, i.e. number
of occasions on which ATB time was recorded for the TGRP.
[ATB = There is no idle trunk for call processing]

P30304-E0731-K170-1-7617 23
Trunk Group Measurement Data Description of Output Data

- Data segment: REC TGRP [Index=3]

Field Field name Description


no.
10 CCS Number of released calls after TGRP seizure (CC:O) because
CONGESTION the backward signal for “congestion“ (all trunks busy) was
received from downstream exchanges (transit or destination
exchange).
11 CCS INCMP DIAL Number of released calls after TGRP seizure (CC:O was
incremented before) caused by:
- calling subscriber going on-hook after incomplete dialing (state
of call in own exchange is still incomplete dialing) or
- timeout of inter-digit time supervision
12 CCS UNALL NUM Number of released calls after TGRP seizure (CC:O) because
the dialed directory number was not created or because the
calling party is not authorized to make calls to this destination
(SPCONN, CUG and service)
13 CCS RELORIG Number of released calls after TGRP seizure (CC:O) due to
ENDTOEND „clear forward“ from the originating exchange, without the actual
reason for release being known in the transit exchange. In
transit exchanges, this counter is only updated if end-to-end
signaling is used between originating and terminating
exchange.
14 CCS SUB BUSY Number of released calls after TGRP seizure (CC:O) because
the backward signal „subscriber terminal busy“ was received.
15 CCS INT TECHN Number of released calls after TGRP seizure (CC:O) due to
IRREG technical fault in own exchange, e.g.
- LTG failure on A- or B-side
- Force Release after SN-through connection
- COC failure
- Channel, port, switch glare
16 CCS EXT TECHN Number of released calls after TGRP seizure (CC:O) due to a
IRREG technical fault in the network outside the own exchange.
Increment for e.g.
- trunk glare
- invalid message
- hop counter with value ZERO is received from previous
exchange
17 CCS Number of released calls after TGRP seizure (CC:O), caused
UNANSWERED by:
- called subscriber does not answer (ringing tone timeout) or
- calling subscriber releases connection after call in own
exchange reached state ‘end of dialing’/’complete dialing’ and
before called subscriber answers or
- ISDN-terminal is not connected
18 unused

24 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

- Data segment: REC TGRP [Index=4]

Field Field name Description


no.
10 CCU SUM Number of unsuccessful attempts to seize the TGRP. This
OFL/LOSS represents the sum of overflow calls and lost calls. For TGRPs
in the high-usage route or final route it represents the sum of
lost calls.
11 CCU LOST CALLS Number of calls offered to the TGRP as first choice route which
then overflowed but were unsuccessful in all alternate routes
(counter is incremented for the first choice TGRP only). Calls
rejected after being offered to the final TGRP as first-choice
route are also counted on this counter.
In NH-network this counter is incremented for the Direct route
(signed by PRIM).
Notes:
1) There are cases in which only CCU_LOST_CALLS is
incremented, but no other CCU-counter (e.g. RCREQS =
Reverse Charging at setup time over analog TGRP is rejected
with RCT#176, because ISUP is required)
12 CCU NM TGRP Number of attempts to seize the TGRP but rejected due to
BLOCKING network management actions in the TGRP (cancel from, cancel
to, skip)
This reason results in
- ‘Lost calls’ (no overflow) for ‘cancel to/cancel from’
- overflow to next route for NM control ‘skip’.
13 CCU TECHN Number of unsuccessful attempts to seize the TGRP due to a
IRREGULAR technical fault, e.g.
- database fault/inconsistency
- unsuccessful entering the trunk busy state
- SN blocking (no access to outgoing trunk)
- Force Release before SN-through connection
- Echo-Control-Device Loop could not be inserted
- invalid message-data or an data-base-failure or a come-again-
request for code-processing
- not able to seize internal resources ( not able to secure CHR,
not able to release B-side CHR from maintenance, not able to
select a speech channel)
- ...
This reason results in ‘Lost calls’ (no overflow).
14 CCU TGRP Number of call attempts to a TGRP which were overflowed
BLOCKED (‘Querwegbündel’ = high-usage route) to an alternate route or
were result in ‘lost calls’ (final route/ direct route) because the
TGRP was blocked for administration or maintenance.
15 CCU TRUNK- Number of call attempts to a TGRP which were overflowed
RESERVATION (‘Querwegbündel’ = high-usage route) to an alternate route or
were result in ‘lost calls’ (final route/ direct route) because all
free trunks of this TGRP were reserved.

P30304-E0731-K170-1-7617 25
Trunk Group Measurement Data Description of Output Data

Field Field name Description


no.
16 CCU ALL Number of unsuccessful attempts to seize a TGRP because
TRUNKS BUSY there is no idle trunk found in the TGRP in the CP.
This reason results in an overflow to an alternate route or if last
route in ‘Lost calls.
17 QOS TRAFFIC Number of unsuccessful attempts to seize a trunk group due to
CONTROL traffic restrictions for Quality of Service
18 unused

26 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

- Data segment: REC TGRP [Index=5]

Field Field name Description


no.
10 NUMB CCS7 Number of instances of overload, i.e. number of occasions on
DPC OLOAD which DPC overload was recorded for the TGRP.
- CCS7 specific -
11 CCS7 DPC Overload duration due to DPC overload in the CCS7-TGRP
OLOAD (SEC) - CCS7 specific -
12 CCS CCS7 NORM Number of released calls after TGRP seizure (CC:O) because
UNSPEC line signal CALL_FAILURE (TUP) was received or in case of
ISUP, after receiving certain line signals (IUC) in CCS7
messages.
Note:
Counter is also incremented during release of the unanswered
call by activation of CCNR.
(Reason: „normal unspecified“ is required for DSS1 CCNR
activation.)
- CCS7 specific -
13 CCU CCS7 Number of call attempts to a TGRP (circuit group) with CCS7-
CCNC OLOAD signaling which overflowed (‘Querwegbündel’ = high-usage
route) to an alternate route or were result in ‘lost calls’ (final
route/ direct route) due to CCNC-overload in the own exchange.
- CCS7 specific -
14 CCU CCS7 DPC Number of call attempts to a TGRP (circuit group) with CCS7-
OLOAD signaling which were overflowed (‘Querwegbündel’ = high-
usage route) to an alternate route or were result in ‘lost calls’
(final route/ direct route) due to CCNC-overload in the
destination exchange / following exchange.
If a TFC- Message was received
- from the subsequent overloaded exchange or
- from the own exchange if overload is detected between SIPA
and SILT
then the user (ISUP, TUP ...) is informed.
- CCS7 specific -
15 CCU CCS7 DPC Skipped or canceled calls due to Automatic Congestion Control
OL ACC (ACC)
Number of call attempts to a TGRP (circuit group) with CCS7-
signaling which were overflowed (SKIP_ACC) to an alternate
route or were result in ‘lost calls’ (final route/ direct route)
(CANCEL_ACC) because ACC (? the capacity of the link
transmission buffer (SILT) was exceeded) for the selected
outgoing trunk.
If a No.7-message RLS (release) from the subsequent
exchange is received which contains a congestion indicator
(overload level) then further calls may be not through connected
for this reason.
- CCS7 specific -
16 unused
17 unused
18 unused
- Data segment: REC TGRP [Index=6]

P30304-E0731-K170-1-7617 27
Trunk Group Measurement Data Description of Output Data

Field Field name Description


no.
10 CC:NH DIRECT:O Number of calls, accepted by the NH-TGRP for direct routed
traffic.
(TGRP is seized successfully and SN is connected through)
- NH specific -
11 TV NH DIRECT:O Volume of traffic, accepted by the NH-TGRP for direct routed
(ERLS) traffic.
(TGRP is seized successfully and SN is connected through)
Unit = Erlang-seconds
- NH specific -
12 CCS NH DIRECT Number of answered calls, over the NH-TGRP for direct routed
ANSW:O traffic
- NH specific -
13 CCU NH DIRECT Number of unsuccessful call attempts of a NH-TGRP/ TGRP-
OFL Cluster for direct route traffic, which results in an overflows from
direct route to an alternate route
- NH specific -
14 CC NH ALT1:O Number of calls, accepted by the NH-TGRP for alternate routed
traffic, first section.
(TGRP is seized successfully and SN is connected through)
- NH specific -
15 TV NH ALT1:O Volume of traffic, accepted by the NH-TGRP for alternate
(ERLS) routed traffic, first section.
(TGRP is seized successfully and SN is connected through)
Unit = Erlang-seconds
- NH specific -
16 CCS NH ALT1 Number of answered calls, over the NH-TGRP for alternate
ANSW:O routed traffic first section
- NH specific -

28 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

Field Field name Description


no.
17 CC NH ALT1 Number of accepted TGRP seizes for which a rerouting attempt
REROUTING is necessary:
call was not successful on alternate route, second section (in
the succeeded neighbor exchange) because:
- cause 27 (destination out of order)
- cause 34 (no circuit available)
- cause 38 (network out of order)
- cause 41 (temporary failure)
- cause 42 (switching equipment congestion)
- cause 47 (resource unavailable, unspecified
If it is a ISUP-TGRP (SPC is signaled), then the SPC is
checked:
The not successful exchange must be a neighbor exchange.
NH-Rerouting is allowed (administered for the whole
exchange)
rerouting limit is not exceeded (only one rerouting is allowed)
There must be a further alternate route (1...8 attempts per call
are possible to find an alternate route. Administration by
CR/MOD ODR:ODR=name, MAXATT=1..8 Def.: 4)
- NH specific -
18 CCU NH ALT1 Number of unsuccessful attempts to seize a NH-TGRP for
LOST alternate route traffic (first section) which result in lost of
complete call because:
- there is no further alternate route
(1...8 attempts per call to find a alternate route are possible.
Administration by MML:
CR/MOD ODR:ODR=name, MAXATT=1..8 Def.:=4)
- A rerouting should be performed but the limit of number of
rewritings is reached (only one rerouting is allowed)
- rerouting should be performed, but rerouting isn’t active.
This counter is incremented for the last used TGRP before
loosing call.
- NH specific -

P30304-E0731-K170-1-7617 29
Trunk Group Measurement Data Description of Output Data

- Data segment: REC TGRP [Index=7]

Field Field name Description


no.
10 CC NH ALT2:O Number of calls, accepted by this NH-TGRP for alternate routed
traffic, second section.
(TGRP is seized successfully and SN is connected through)
- NH specific -
11 TV NH ALT2:O Volume of traffic, accepted by this NH-TGRP for alternate
(ERLS) routed traffic, second section.
(TGRP is seized successfully and SN is connected through)
Unit = Erlang-seconds
- NH specific -
12 CCS NH ALT2 Number of answered calls, over this NH-TGRP for alternate
ANSW:O routed traffic second section
- NH specific -
13 CCU NH ALT2 Number of unsuccessful attempts to seize this NH-
TGRP/TGRP-Cluster for alternate route traffic (second section).
a) All unsuccessful reasons (because ATB, Trunk-reservation,
TGRP blocked,...) are considered.
b) Counter is not incremented during overflow within a TGRP-
Cluster.
c) for unsuccessful attempts to seize a TGRP-cluster the
counter is incremented for the last TGRP of the cluster which
was tried to seize.
- NH specific -
14 unused
15 unused
16 unused
17 unused
18 unused

30 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

- Data segment: REC TGRP [Index=8]

Field Field name Description


no.
10 CC PRECEDENCE:I Number of TGRP incoming calls with
a) precedence (MLPP) level above ROUTINE, i.e.
PL0: FLASH OVERRIDE (MLPPFLOV)
PL1: FLASH (MLPPFL)
PL2: IMMEDIATE (MLPPIMM)
PL3: PRIORITY (MLPPPRIO)
or
b) BEV (TOLLCAT), independent on catastrophe state
- MLPP specific -
11 CC Number of TGRP outgoing calls with
PRECEDENCE:O a) precedence (MLPP) level above ROUTINE, i.e.
PL0: FLASH OVERRIDE (MLPPFLOV)
PL1: FLASH (MLPPFL)
PL2: IMMEDIATE (MLPPIMM)
PL3: PRIORITY (MLPPPRIO)
or
b) BEV (TOLLCAT), independent on catastrophe state
- MLPP specific -
12 CC PREEMPTED:I Number of preempted (forced released) TGRP incoming calls
by MLPP or BEV
- MLPP specific -
13 CC PREEMPTED:O Number of preempted (forced released) TGRP outgoing calls
by MLPP or BEV
- MLPP specific -
14 unused
15 unused
16 unused
17 unused
18 unused

P30304-E0731-K170-1-7617 31
Trunk Group Measurement Data Description of Output Data

6 Operating Instructions

6.1 File Sizes


Table with characteristic file sizes, different for files on disk (MDD) and postprocessing files,
each with output of the common header record and the project specific header record (DTAG).
The entries show a minimum and a maximum value. The first value shows the minimum value
of a data output only for one index, the second value shows the maximum value of a data
output for all indices (e.g. for a NH routed CCS7 bothway trunk group).

Measurement ranges:
(1) 10 measurement objects, 1 hour
(2) 1 measurement object, 1 day
(3) 10 measurement objects, 1 day

Measurement Disk file size (MDD) Post-processing file size


[PAM page=2048 bytes] [PAM page=2048 bytes]
REC (1) (2) (3) (1) (2) (3)
TGRP 2/8 5 / 21 25 / 183 2 / 12 5 / 29 35 / 272
Table 12: Characteristic file sizes, MDD/Postprocessing

Common file size calculation see Error! Reference source not found..

32 P30304-E0731-K170-1-7617
Description of Output Data Trunk Group Measurement Data

7 Examples
None

Part REC DN Data

P30304-E0731-K170-1-7617 33