CHB
EXTERNAL WALL EXTERNAL WALL INTERIOR WALL
1 2 2' 3
FFL FFL FFL
5600
300
300
3000 2650 900 2050
10mmØ VERT. BARS 10mmØ VERT. BARS 10mmØ VERT. BARS
NGL SPACED @ 0.60m. O.C. NGL SPACED @ 0.60m. O.C. NGL SPACED @ 0.60m. O.C.
1850 1100 W/ 10mmØ HOR. BARS W/ 10mmØ HOR. BARS W/ 10mmØ HOR. BARS
@ EVERY THIRD LAYER @ EVERY THIRD LAYER @ EVERY THIRD LAYER
400
400
OF CHB OF CHB OF CHB
LAUNDRY
1600
ELEV. +0.15M 3-10mmØ LONG. BARS 3-10mmØ LONG. BARS 3-10mmØ LONG. BARS
C1F1 C2F2 C1F1 W/ 10mmØ TRANSVERSE W/ 10mmØ TRANSVERSE W/ 10mmØ TRANSVERSE
200
200
WF-1 WF-1
BARS
BARS SPACED
SPACED @ 0.30m.
@ 0.30m. O.C.O.C. BARS SPACED @ 0.30m. O.C. BARS SPACED @ 0.30m. O.C.
A
ELEV.
450
2100
2100
STAIRWELL +0.10M 450 400
WF-3
KITCHEN
ELEV. +0.20M
C3F3 WF-1 WF-2
WF-1
5500
FILL
ELEV. +0.30M
2200
WF-2
2900
C1F1
DINING
LIVING
2 WALL FOOTING DETAIL
B C1F1
700
SLAB ON PORCH
B'
500
FILL ELEV. +0.15M
5000
C CARPORT WF-1
ELEV. +0.00M C2F2 C1F1
10MM DIA SPACED
C O L U M N S C H E D U L E WHICHEVER DIMENSION IS GREATER GOVERNS
2500
3000 2200 2650 750 COL-1 150 400 6-16mmØ VERTICAL BARS 2@0.05M, 6@0.15M, REST @ 0.25M O.C
COL-2 150 400 6-16mmØ & 2- 12mmØ VERTICAL BARS 2 TIES - 2@0.05M, 6@0.15M, REST @ 0.25M O.C
COL-3 150 300 6-12mmØ VERTICAL BARS 2@0.05M, 6@0.15M, REST @ 0.25M O.C BOTTOM BARS BOTTOM BARS
S-3
L
2100
2100
2B-1
2B-3
A'
2B-1
THK
2B-2
5500
5500
2200
2B-4
2B-1
S-2
2900
ELEV. +3.10M
S-1
PLAN ELEVATION
2B-3 ELEV. +3.10M
B B E A M S C H E D U L E
700
S-4 CB-1
TYPICAL COLUMN -FOOTING DETAIL
1200
ELEV. +3.00M
B'
500
100mm DROP
TOP BAR BOT. BAR TOP BAR BOT. BAR TOP BAR BOT. BAR
2250 2650 750 2B-1 200 350 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 2@0.05M, 6@0.15M, REST @ 0.25M O.C
2B-2 200 350 2-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 2-16mmØ 2-16mmØ 2@0.05M, 4@0.15M, REST @ 0.25M O.C
NOTES:
2B-3 150 300 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2-16mmØ 2@0.05M, 4@0.15M, REST @ 0.25M O.C
1. NO FOOTING SHOULD REST ON BACKFILLED MATERIALS. 4. ALL PLANTED COLUMNS MUST BE SUPPORTED BY BEAMS. 2B-4 250 6-16mmØ 3-16mmØ 2-16mmØ 6-16mmØ 6-16mmØ 3-16mmØ 2@0.05M, 6@0.15M, REST @ 0.25M O.C
400
2. IN CASE THE SOIL CONDITION AT THE FOUNDING LEVEL 5. EARTH FILLING SHALL BE OF GOOD QUALITY SOIL
FOOTING CAN'T BE AS CERTAINED, THE CONTRACTOR MUST NON-PLASTIC TO AVOID SETTLEMENT. 2CBM-1 150 350 6-16mmØ 3-16mmØ 6-16mmØ 3-16mmØ 6-16mmØ 3-16mmØ 2@0.05M, REST @ 0.15M O.C
CONSULT A SOIL EXPERT OR A GEOTECHNICAL ENGINEER 6. FILL SHALL BE COMPACTED IN LAYERS OF 200MM TO
SECOND AND EXPLORE THE SURFACE CONDITION. A RELATIVE DENSITY OF 95%.
3. NO PIPE SHALL BE EMBEDDED INSIDE ANY COLUMN. 7. REMOVE / REPLACE TOP SOIL WHICH ARE HIGHLY PLASTIC
3 FLOOR FRAMING PLAN TO AVOID CRACKING OF SLAB ON FILL.
RB-1 150 300 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 2-12mmØ 2@0.05M, 4@0.15M, REST @ 0.25M O.C
A-2 S-1 SCALE 1:100MTS. RB-2 150 350 3-12mmØ 2-12mmØ 2-12mmØ 3-12mmØ 3-12mmØ 2-12mmØ 2@0.05M, 4@0.15M, REST @ 0.25M O.C
RB-3 200 350 3-12mmØ 2-12mmØ 2-12mmØ 6-12mmØ 3-12mmØ 2-12mmØ 2@0.05M, 6@0.15M, REST @ 0.25M O.C
RB-4 250 400 4-16mmØ 2-16mmØ 2-16mmØ 4-16mmØ 4-16mmØ 2-16mmØ 2@0.05M, 6@0.15M, REST @ 0.25M O.C
Architects
Pasig City, Metro Manila, Philippines 1605
REG. NO.
PTR. NO.
TIN.
DATE:
OWNER:
---
TYPICAL GIRDER/BEAM DETAIL
SLAB SCHEDULE
BEAM SCHEDULE
NOTES