Вы находитесь на странице: 1из 10

CHHATTISGARH STATE ROAD SECTOR DEVELOPMENT PROJECT

Rehabilitation and Upgradation of Anda - Funda Road (MDR)


Package No. 14
CHEEK LIST FOR CONCRETE MIX DESIGN
P.Q.C. M-40

1 Source Approval YES NO NA


I. Aggregate
II.Sand
III.Cement
IV. Water
V. Admixture

2 Coarse Aggregate Test Result


Physical
I Individual Gradation conforming ?

II AIV conforming ?

III FI&EI conforming ?


Specific Gravity submitted?
IV

V Water absorption conforming ?

VI Deterious Content conforming ?

Chemical
I Alkali aggregate reactivity conforming ?
II Soundness coforming ?
III Chloride content confomring ?
IV SO3 Submitted

3 Fine Aggregate Test Result


Physical
I Gradation conforming ?
Specific Gravity submitted ?
II
III Water absorption conforming ?
IV Fineness Modulus conforming ?
Chemical
I Alkali aggregate reactivity conforming ?
II Soundness coforming ?
III Chloride content confomring ?
IV SO3 Content confomring ?
YES NO NA
4 CA combnied grading conforming ?

5 Cement Test Result


Physical
I Specific gravity submitted ?
Chemical
I Chloride content confomring ?
II SO3 Content confomring ?

6 Trail Mix details submitted ?

7 CA: FA as per table-3 of IS 10262 Taken ?

8 Total Chloride and SO3 content with in the limits ?

Contractor Representative Consultant Representative


)
tant Representative
CHHATTISGARH STATE ROAD SECTOR DEVELOPMENT PROJECT
Package No. 14, Rehabilitation and Upgradation of Anda - Funda ( MDR )

Client : PWD Raipur (Chhattisgarh), ADB Project


Consultant : EGIS International Pvt. Ltd. JV with EGIS India CS Pvt. Ltd.
Contractor : AMAR - DRA ( J/V )

Summary of PQC Mix Design Trial's

Compressive
Flexural Strength
Mix Proportion in Dry Condition for 1 m3 Slump Observed in mm Strength
( N/mm2 )
( N/mm2 )
Trail Chloride
No. Cement C.A.-I C.A. -II F.A. Admixture Content
Water Coarse
(20mm) (10mm) (Natural W/C After 30 After 60
Agg. / Fine Initial 7 days. 28 days. 7 days. 28 days.
Sand) Ratio minuts minuts
(Kg) (Kg) (%) Agg. Ratio
(Kg) (Kg) (Kg) (Kg)

1 425 179 570 570 670 4.68 1.10 0.42 62 : 38 130 mm 80 mm 45 mm 35.93 48.38 3.61 4.85 0.0285

2 425 179 570 570 670 4.25 1.00 0.42 62 : 38 115 mm 70 mm 40 mm 38.78 51.22 4.06 5.20 0.0285

3 425 179 570 570 670 3.40 0.80 0.42 62 : 38 95 mm 60 mm 30 mm 40.29 53.22 4.59 5.56 0.0285
Contractor Reprasantative Consultant Rep
SO3
Remark
Content

2.139

2.139

Average 28 days
compressive strength
result found ok &
2.139 Workability of slump
requrements of PQC,
hence found
Satisfactory.
Consultant Reprasantative

Вам также может понравиться