Академический Документы
Профессиональный Документы
Культура Документы
Available Devices
Proximity Switch
• Non-powered device with cycle indication switch
• Simple arrangement allowing monitoring/trending/shutdown logic
by package control panel
• Separate mechanical visual cycle indicator included on new unit
installations
Specification
Proximity
DNFT
Programmable Advanced
Switch DNFT
Shutdown Signal NO YES YES
Application
Proximity Signal YES YES YES
Local Cycle Indicator Separate Indicator YES: LED YES: LCD & LED
Compressors with DNFTs can
either use the no-flow switch to
De-Bounce Included NO YES YES
directly shutdown the unit or use
Lithium Battery (A-10807) Lithium Battery (A-10807)
Power N/A
24VDC Panel Power 24VDC Panel Power
the included proximity switch with
Programmable: the package control panel to create
Shutdown Time PLC 180 Seconds
20-255 Seconds customized control logic.
Area Classification CSA, IECEX, ATEX
Advanced panels can watch both the
CSA 186200 (Canada): Ex d m IIC T5
CSA
CSA 186200 (US): Ex d m IIC T5, Class I, Zone 1, AEx d mb IIC T5 Gb no-flow alarm signal from the DNFT
IECEX IECEx CSA 12.0020, Ex d mb IIC T5 Gb and the proximity switch circuit,
ATEX II 2G SIRA 12ATEX1357, Ex d mb IIC T5 G allowing customized alarms and
shutdowns, as well as cycle time and
Temperature -40°F to +131°F (-40°C to +55°C)
oil consumption trending.
Max. Switch Voltage 240 VDC