Вы находитесь на странице: 1из 3

FAS 16 mm FLATPROP EQI

Pressure compensated proportional valve

>> 2/2 NC pressure > Flat plunger and spring


compensated for frictionless opera-
proportional valve tion
> High precision > Highly repeatable with
> Increased flow - over 100 million cycles
120 l/min of Air at 2 bar

Technical features
Medium: Operating pressure: Internal leakage: Materials:
Air, oxygen or neutral gases 0 ... 7 bar (0 ... 101 psi) < 10-2 mbar l/s (≈0,6 ml/min) Body: Stainless steel only or
Orifice: Back pressure: 0 ... pmax stainless steel/brass
4,5 mm Maximum 10% of inlet pressure External leakage: PEEK (only when mounted on sub
Filtration: Mounting: < 10-2 mbar l/s (≈0,6 ml/min) base)
A filtration of 20 micrometer is Cartridge, manifold p = 9,5 bar Seal: FPM, NBR, EPDM
required before the inlet Size: Weight:
Operation: 16 mm < 50 g (0.11 lbs) Manifolds
2-way valve Normally closed Life expectancy: Ambient/media temperature: Contact your local fluid control
Hysteresis: ≥ 100 Mio. cycles (with triangular +10 ... +50 °C (+50 ... +122°F) specialist for information about
See diagrams on page 2 signal) our manifolding capabilities which
include laminated polymer
manifolds.

Electrical details Following options on request


Voltage/frequency: See Technical data - Standard coils Specific coils
Power consumption 2,5 W nominal at T=20°C Wider temperature range
Insulation class: F (155 °C) Higher acceptable back pressure
Electrical insulation: 1000 V a.c. OEM specification
Protection degree: IP 51
Duty cycle: 100%
Electrical connection: 300 mm A WG24 flying leads

Technical data - Standard models


Symbol Voltage Current Resistance Body Seal Model
(V d.c.) (mA) (Ω) Material Material
6 417 14,4 Stainless steel/brass FPM 12-216C-04521+EQIFIL+BEK
9,5 264 36 Stainless steel/brass FPM 12-216C-04521+EQIFIL+BEH
12 211 57 Stainless steel/brass FPM 12-216C-04521+EQIFIL+BED
18 138 130 Stainless steel/brass FPM 12-216C-04521+EQIFIL+BDZ
12 2 10
24 104 230 Stainless steel/brass FPM 12-216C-04521+EQIFIL+BDU
6 417 14,4 Stainless steel/brass NBR 12-216C-04520+EQIFIL+BEK
1
9,5 264 36 Stainless steel/brass NBR 12-216C-04520+EQIFIL+BEH
12 211 57 Stainless steel/brass NBR 12-216C-04520+EQIFIL+BED
18 138 130 Stainless steel/brass NBR 12-216C-04520+EQIFIL+BDZ
24 104 230 Stainless steel/brass NBR 12-216C-04520+EQIFIL+BDU

Technical data - Standard coils


Valve Coil resistance at 20°C Current for maximum flow Voltage +20°C (+68°F) Power +20°C (+68°F) Max. required voltage for
orifice (+68°F) ± 3% [R20] [nominal] [nominal] [nominal] max flow
(mm) (Ω) (mA) (V) (W) (V) *1)
4,5 14,4 417 6 2,5 9
36 264 9,5 2,5 14
57 211 12 2,5 18
130 138 18 2,5 27
230 104 24 2,5 36

*1) Please refer to instruction K12M.0001 for recommendation on drive signals

Our policy is one of continued research and development. We therefore reserve the right to amend, without 01/16
notice, the specifications given in this document. (2016 - 6008a) © 2015 Fluid Automation Systems s.a. en 6.6.009.01
FAS 16 mm FLATPROP EQI
Pressure compensated proportional valve

Additional information
Typical flows vs. supply pressure Typical Hysteresis curves
Air, 20°C, without back pressure Air, 20°C, without back pressure

Stdl/min
l/min
300
350 p = 7 bar
250
300

250 200
Max. flow

p = 3 bar
200 150

Flow
150
100
100
50
50
p = 0,1 bar
0
0
0 1 2 3 4 5 6 7 bar 0 100 150 200 250 300 350 400 mA

Supply pressure Current

Note: Accessories
Flow vs. supply pressure curves are for informative purposes only and shall be used Manifold for cartridge version
only for the pre-selection of the orifice size. Preliminary testing is recommended to with G1/4 ports in aluminium
take into account all application specific requirements and to select the most
adequate orifice. For further information contact your local fluidic specialist.

Page 3
S120.0152

FLATPROP EQI cartridge mounting FLATPROP EQI with manifold Dimensions in mm


Projection/First angle
on request

300 ± 10
5
2,5 ± 0,05

22,3

ø15 ± 0,1
± 0,4
38,1

44,7
0,75 ± 0,05

2 2

1
6,7

7,4

1 2 3
1
5

9,7 4,2
6
3,8
300 ± 10

4 14
,8
15,5
,8

ø1
14

6,6
17

1 O ring Ø 6 x 1 5 O ring Ø 4 x 1 (2x)


2 O ring Ø 12 x 1 6 Screws Torx M3 x 18 (2x)
3 Manifold, not in scope of delivery
4 Screws Torx M 3 x 6

Our policy is one of continued research and development. We therefore reserve the right to amend, without 
en 6.6.009.02 notice, the specifications given in this document. (2016 - 6008a) © 2015 Fluid Automation Systems s.a. 01/16
FAS 16 mm FLATPROP EQI
Pressure compensated proportional valve

Cartridge fitting Test manifold Dimensions in mm


Projection/First angle
D120.0010 S120.0152

A-A
ø 5 +0
-0,2
A 0,2 A B
B 11,7
G1/4

0,2 x 45°
11,6 + 0,2

12
B 1
6,4 ± 0,2

ø14,8 ± 0,05
15°
ø7,6 H7

ø14 H7
ø 9,09

ø17

50
0,1 A B 0.8
≥8,5
30°

0.8

12
,45
R0 0,05 A B
30 10
A B 0,1 A B
3,7 ± 0,1 0,7 G1/4
1,5 11,3 30
20,5 0,02 A
0,2 A B 12,8
≥15,3 A
B-B
M3

ø 0,01 CZ 1 Interface geometry see Cartridge fitting D120.0010


X
R 0,45
8
15°

11

0,1 A B
1,55

Warning
These products are intended for use in air, oxygen and neutral gas The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under »Technical features«. safeguards to prevent personal injury or damage to equipment in the
event of such failure.
Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other System designers must provide a warning to end users in the system
applications not within published specifications, consult instructional manual if protection against a failure mode cannot be
IMI Precision Engineering, Fluid Automation Systems s.a. adequately provided.

Through misuse, age, or malfunction, components used in fluid


power systems can fail in various modes.

Our policy is one of continued research and development. We therefore reserve the right to amend, without
01/16 notice, the specifications given in this document. (2016 - 6008a) © 2015 Fluid Automation Systems s.a. en 6.6.009.03
Diese Produkte sind ausschließlich mit Druckluft-, Sauerstoff- und neu- Systemauslegern wird dringend empfohlen, die Störungsarten aller
trale Gassysteme zu verwenden. Sie sind dort einzusetzen, wo die unter in Pneumatiksystemen verwendeten Komponententeile zu berück-

Вам также может понравиться