PA1100-A

User’s Manual

M
-
T
e
c
h
1. LCD Display mode

1.1 Initial START Screen

<PA1100-A>

PAN-ASIA[M-Tech]

1.2 Scanning mode


As a Normal display mode, each channel is scanned at 2-
Sec intervals and displayed.

H-1234 Scan CH1


Tank Name : 1WBT(P)
Height (M) : 12.345
S_ Gravity : 1.025

H-1234 Scan CH2


Tank Name : 1WBT(S)
Height (M) : 12.345
S_ Gravity : 1.025

H-1234 Scan CH8


Tank Name : 4WBT(S)
Height (M) : 12.345
S_ Gravity : 1.025
1. LCD Display mode
1.3 Locking mode
With one click of MODE button, it changes to locking mode,
And continuously displays a specific channel.
LEFT button switches to previous channel, and RIGHT button
moves to the next channel.

Mode Key H-1234 Lock CH1


Tank Name : 1WBT(P)
Height (M) : 12.345
S_ Gravity : 1.025

Right Key
H-1234 Lock CH2
Tank Name : 1WBT(S)
Height (M) : 12.345
S_ Gravity : 1.025

Right Key
H-1234 Lock CH3
Tank Name : 2WBT(P)
Height (M) : 12.345
S_ Gravity : 1.025

Left Key
H-1234 Lock CH2
Tank Name : 1WBT(S)
Height (M) : 12.345
S_ Gravity : 1.025
1. LCD Display mode
1.4 All display mode
Pushing MODE button one more time in Locking mode changes
to All display mode, and displays the entire channel.

1;+12.345__2;+ 2.345
3;+23.234__4;+34.532
5;+11.344__6;+11.342
7;+16.443__8;+14.222

Pushing MODE button again in All display mode changes


to Normal Display mode (Scanning mode).

H-1234 Scan CH1


Tank Name : 1WBT(P)
Height (M) : 12.345
S_ Gravity : 1.025

The backlight of LCD is turned on with a push of button, and


To turn off, push Up button when it’s on.
The backlight of LCD gets automatically turned off If left idle
without any input of keys for two minutes.
2.System Setting Mode

Pushing SET button in LCD display mode changes to System Setting


Mode.

For configuration program for Service engineer, a batch setting is


allowed with communication port in PA-1100 using PC or Notebook
and exclusive RS-485 converter.

For the setting of several PA-1100’s when connection is


complete, the connection to Master must be removed.
When the connection to Master is not removed, with the conflict
of communication line, PA-1100 or the system of Master could
seriously be damaged.

<Setting Mode>

Password:0000

(Fig. password Input Screen)

Cursor starts at ”0,” and with a push of UP button, its value changes
in between 0~9.
With RIGHT button, cursor moves to the next location. Pushing SET
Button after setting the values of four digits, it enters into Setting
mode.

<Setting Mode>

Password: FAIL

(Fig. password Error Screen)


When Password differs from the set data, the above screen shows
and requests an input of password again.
2.System Setting Mode
Setting mode is divided in to the things to be set in PA1100 and
the things to be set in the own exclusive Configuration Program.

Things to be set in PA1100 are limited to the ID of instrument, Tank


Height of each channel, Specific Gravity, zero span value , AD
Value and offset value.
Only in the
Own Program

Hull Name: PAN-ASIA


Tank Name: 1WBT(P)
Possible in both
Own Program
and PA1100

CH1 Setting AD:00000


Zero :+00.000 00000
Span :+00.000 00000
OS : +00.000 SG; 1.000

Pushing RIGHT button moves cursor to the right, and LEFT button
to the left. Pushing UP button changes cursor at its location to a
value between 0~9.
Input set value using RIGHT,LEFT button and UP button.
Pushing MODE button moves to the next channel setting screen.

CH2 Setting AD:00000


Zero :+00.000 00000
Span :+00.000 00000
OS : +00.000 SG; 1.000
2.System Setting Mode
Using RIGHT & LEFT buttons and UP button to input set value.
At each push of MODE button, it moves to channel setting screen.

Mode Key
CH3 Setting AD:00000
Zero :+00.000 00000
Span :+00.000 00000
OS : +00.000 SG; 1.000
Mode Key
CH4 Setting AD:00000
Zero :+00.000 00000
Span :+00.000 00000
OS : +00.000 SG; 1.000

Mode Key CH8 Setting AD:00000


Zero :+00.000 00000
Span :+00.000 00000
OS : +00.000 SG; 1.000

Mode Key
< ID Setting >

Input ID :00 (0~99)

Mode Key
Enter SET key !
To exit setting !
2.System Setting Mode
For Zero value, use 4mA at an applicable channel, and for Span,
use 20mA and input the indicating AD value.

CH1 Setting AD:12345


Zero;+00.000 12345
Span;+00.000 00000
OS ;+00.000 SG: 0.000
(Fig. zero Input Screen)

CH1 Setting AD:45678


Zero;+00.000 12345
Span;+12.200 45678
OS ;+00.200 SG: 1.000

(Fig. span Input Screen)

OS signifies offset, a value including dead zone


SG refers to Specific gravity.

SET button stores the set data as shown in the figure below.

CH1 Saved !!

Without pushing SET button, the set data is not stored and
maintains the existing value.
2.System Setting Mode

The ID of the instrument is only usable at the main body of


PA-1100. To set several PA-1100 instruments using own
configuration program, first, an ID must surely be given to the
instrument.

Mode Key < ID Setting >

Input ID :00 (0~99)

The ID of the instrument can be generated up to no. 99, but by its


Nature of electrical property, it is physically not possible to be
connected to 99 items.