GENERAL NOTES: SCHEDULE OF LOADS: PP-N

SERVICE ENTRANCE

LEGEND & SYMBOLS:


WEATHER HEAD CAP 230 V, 1Ø,3W,60Hz
CONCRETE POLE
THIRD FLOOR LINE
MERALCO POWER SOURCE M KW-HR METER
230 Vac, 60Hz, 2P, 3wire OUTLET
CKT. NO. LOAD SERVED VA VOLTS AMP BRANCH CIRCUIT
2 - 80.0 Sq.mm THHN SIZE OF WIRES SIZE OF CONDUIT
1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH 1 - 14.0 Sq. mm. THW L.O. C.O. PROTECTION
THESE PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST SERVICE ENTRANCE PP POWER PANEL BOARD IN 40 mm Ø RSC

MCB 1 LIGHTING OUTLET (GRD. FLR.) 1,200 230 5.22 12 15 AT, 2P CB USE: 2-2.0 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
EDITION OF THE P.E.C. THE RULES AND REGULATIONS OF THE LOCAL ENFORCING 2 - 80.0 Sq.mm THHN
1 - 14.0 Sq. mm. THW
AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANIES,THE IN 40 mm Ø RSC
150 AT 2 LIGHTING OUTLET (GRD. FLR.) 1,800 230 7.83 18 15 AT, 2P CB USE: 2-2.0 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
CIRCUIT BREAKER LIGHTING CIRCUIT LINE SECOND FLOOR LINE
2P, 230 V
ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY 3 LIGHTING OUTLET (2ND FLR.) 1,600 230 6.96 16 15 AT, 2P CB USE: 2-2.0 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
LICENSED REGISTERED ELECTRICAL ENGINEER. KW-HR METER 2 - 80.0 Sq.mm THHN
1 - 14.0 Sq. mm. THW
IN 40 mm Ø PVC 4 LIGHTING OUTLET (2ND FLR.) 2,000 230 8.70 20 15 AT, 2P CB USE: 2-2.0 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
PP-1
2. THE ELECTRICAL SERVICE VOLTAGE SHALL BE 1-PHASE, 3-WIRE, 230 VOLTS, 60 HZ.
CIRCUIT HOMERUN MAIN CKT. BRKR.
POWER CIRCUIT LINE 150 AMPS. PP-N
150 A
150 AT,2P,
230V,60HZ. 5 CONV. OUTLET (GRD. FLR.) 2,160 230 9.40 12 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
1Ø 15 AT,2P 15 AT,2P

1.40
3. THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN PVC CONDUIT. FLEXIBLE 15 AT,2P 15 AT,2P 6 CONV. OUTLET (GRD. FLR.) 1,260 230 5.48 7 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit

CONDUIT SHALL BE USED WHERE REQUIRED MINIMUM SIZE FOR ALL CONDUITS SHALL BE
GROUND LINE GROUND FLOOR LINE 20 AT,2P 20 AT,2P

KILOWATT-HOUR METER E 8.0 SQ. MM BCW 20 AT,2P 40 AT,2P 7 CONV. OUTLET (GRD. FLR.) 1,620 230 7.05 9 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
15 mm DIA. ELECTRICAL TRADE SIZE, CONDUITS SHALL BE RIGID STEEL CONDUITS ( RSC) SAND & GRAVEL BEDDING
GROUND LINE 40 AT,2P 30 AT,2P

AND SHALL BE USED IN MAIN SERVICE ENTRANCE.


30 AT,2P 30 AT,2P 8 RANGE OUTLET (GRD. FLR.) 1,500 230 6.52 1 40 AT, 2P CB USE: 2-8.0 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
9 WATTS CIRCULAR TYPE PINLIGHT 30 AT,2P 30 AT,2P

PL 20 AT,2P 20 AT,2P
9 REFRIGERATOR OUTLET (GRD. FLR.) 1,500 230 6.52 1 40 AT, 2P CB USE: 2-8.0 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
4. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN" OR "THW" ONE GANG SWITCH 20 AT,2P 20 AT,2P

1.0 HP ACU OUTLET


10 1,250 230 5.43 1 30 AT, 2P CB USE: 2-5.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
UNLESS OTHERWISE INDICATED, THE MINIMUM SIZE FOR POWER AND LIGHTING SHALL BE RISER DIAGRAM ( POWER ) 8.0 SQ. MM BCW
( BEDROOM 1)
2.0 SQ.MM THE CONTROL WIRES SHALL BE AS INDICATED OR SPECIFIED ELSEWHERE ON GROUND LINE 1.0 HP ACU OUTLET
18 WATTS DROP LIGHT 11
( BEDROOM 2)
1,250 230 5.43 1 30 AT, 2P CB USE: 2-5.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
PLANS. DL TWO GANG SWITCH
FROM PLDT
SCHEMATIC DIAGRAM 12
1.0 HP ACU OUTLET
1,250 230 5.43 1 30 AT, 2P CB USE: 2-5.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
CABLE NETWORK (MASTER'S BEDROOM)
PROVIDER WATER HEATER
5. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE 13 1,800 230 7.82 1 30 AT, 2P CB USE: 2-5.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
(GROUND FLOOR)
FOR CONNECTION TO THE POWER SUPPLY. 32 WATTS RING LIGHT W/ DIFFUSER THREE GANG SWITCH WATER HEATER
14 1,800 230 7.82 1 30 AT, 2P CB USE: 2-5.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
(SECOND FLOOR)
RL SECOND FLOOR LINE
6. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND 15 SPARE 1,200 230 5.22 1 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
ALL NON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN TELEPHONE WALL OUTLET RG6 CABLE IN
16 SPARE 1,200 230 5.22 1 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
ACCORDANCE WITH THE PHILIPPINE ELECTRICAL CODE. 20mm Ø uPVC
(TYP.)
25 WATTS WALL LAMP CATV CATV
SB PB
LIVING AREA
SECOND FLOOR LINE 17 SPARE 1,200 230 5.22 1 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
7. ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE CATV

VERIFIED WITH THE OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES SHALL BE MADE CONVENIENCE OUTLET GROUND FLOOR LINE
18 SPARE 1,200 230 5.22 1 20 AT, 2P CB USE: 2-3.5 sq. mm. THHN STR. WIRE 20 mm Ø PVC Conduit
TEL. LIVING
TTC1
ACCORDINGLY. 25 WATTS LAMP POST USE 1-3.5 sq.mm TW(G)
PB AREA
L1
E TOTAL CONNECTED LOAD 26,790 116.50
RSC
COORDINATE WITH CATV PROVIDER
ELBOW
8. ALL MATERIALS TO BE USED AND THE EQUIPMENT TO BE INSTALLED SHALL BE BRAND NEW A EWH
ELEC. WATER HEATER GROUND FLOOR LINE FOR FEEDER LINE : SERVICE FEEDER : ENCLOSURE : NEMA I
8.0 SQ. MM BCW 26,790 VA @ 80% D.F. + 25% (1,250)
ND MUST BE OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PROPOSED
RANGE
RANGE OUTLET RISER DIAGRAM ( CATV ) GROUND LINE
I TOTAL=
230 V
USE 2 - 80.0 sq.mm THHN
1 - 14.0 sq.mm THW
MOUNTING : SURFACE
MAIN : 150 AT, 2P, 230 V CIRCUIT BREAKER
INTENDED. I TOTAL= 94.55 AMPERES / 150 A in 40 mm Ø RSC
ACU CONVENIENCE OUTLET
9. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS: CT
COUNTER TOP CONV. OUTLET ACU SAND & GRAVEL BEDDING

A.) LIGHT SWITCHES - 1.40m ABOVE FLOOR FINISH. RISER DIAGRAM ( TEL. )
B) CONVENIENCE OUTLETS - 0.30m ABOVE FLOOR FINISH. WP
WEATHER PROOF CONV. OUTLET
C.) PANELBOARDS AND CABINETS - 1.40 m ABOVE FLOOR FINISH OR REQUIRED.

A B' B C A B' B C A B' B C A B' B C


12670 12670 12670 12670

6400 4270 2000 6400 4270 2000 6400 4270 2000 6400 4270 2000

2000 1350 7320 2000 2000 1350 7320 2000 2000 1350 7320 2000 2000 1350 7320 2000

12670 12670 12670 12670

1 P R O P E T Y L I N E P R O P E T Y L I N E P R O P E T Y L I N E P R O P E T Y L I N E
E

E
E

E
3
1 UP UP
PP-N
2350

2350

2350

2350

2350

2350

2350

2350
N

N
T&B PP-N T&B 7
SERVICE SERVICE
N

N
LANAI OPEN ABOVE BEDROOM WH LANAI OPEN ABOVE BEDROOM
3000

3000

3000

3000

3000

3000

3000
AREA ROOM 3 AREA 13 PP-N ROOM 3
I

I
DN PP-N DN
I

I
L

L
L

L
2 2
LIVING AREA
4
9
PP-N
LIVING AREA
6
PP-N

PROPETY LINE
PROPETY LINE

PP-N
Y

Y
PP-N
Y

Y
8000

8000

8000

8000

8000

8000
8000

8000

8000

8000

8000
KITCHEN DINING AREA KITCHEN DINING AREA
3650

3650

3650

3650

3650

3650

3650

3650
MASTER'S MASTER'S 12
T

T
AREA AREA
3000

3000

3000

3000

3000

3000

3000
BEDROOM BEDROOM
T

T
BEDROOM BEDROOM PP-N
ROOM 2 ROOM
11 2 TO TTC1CATV
E

E
E

E
10 14
E

E
T&B PP-N T&B
BEDROOM 1 BEDROOM 1
PP-N
TO TTC1 PP-N
P

P
WH
P

P
CATV
3 5
O

O
8
O

O
PP-N
PP-N
2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000

2000
R

R
BALCONY BALCONY
R

R
P

P
P

P
P R O P E T Y L I N E P R O P E T Y L I N E P R O P E T Y L I N E P R O P E T Y L I N E
E

E
N

N
E 7930 I E 7930 I E 7930 I E 7930
10

10

10
10

L L L
L

N N
28

28

28
28

N
Y

Y
I I I
T

T
I
E

E
L L L
L
P

P
O
O

O
R

R
P

P
P

Y Y Y Y
T 23 T 23 T 23 23

T
E 61 61 61 E 61
E

E
P P P P
30

30
O O O O
00

00
30

30
R

00
0

R
0

P TEL.
P P TEL.
P
S.E. S.E.
CATV

CATV
S.E.
S.E.

PO PO
WER WER

2000 2100 6521 2000 2000 2100 6521 2000 2000 2100 6521 2000 2000 2100 6521 2000

6401 4204 2000 6401 4204 2000 6401 4204 2000 6401 4204 2000

12605 12605 12605 12605

LIGHTING LAYOUT LIGHTING LAYOUT POWER LAYOUT POWER LAYOUT


GROUND FLOOR PLAN SECOND FLOOR PLAN GROUND FLOOR PLAN SECOND FLOOR PLAN

ARCHITECT : ENGINEER: PROJECT TITLE: APPROVED BY: DESIGNED: SHEET CONTENTS: SHEET NO:
DRAWN:
AS SHOWN
JOHN CHRISTOPHER L. MAAÑO, UAP REVIEWED:
CHRIS OLIVER R. SANTOS PROPOSED (2) TWO STOREY
ARCHITECT PROFESSIONAL ELECTRICAL ENGINEER CHECKED: E1

PRC Reg. No.: 0029894


RESIDENTIAL HOUSE JERICHO DIONISIO VERSOZA DATE:
E1
DATE: 10 / 14 / 2018 PTR No.: 3805747C PRC Reg. No.: 4282 PTR No.: 1450637 X
T.I.N.: 233-777-777 DATE: 01 / 06 / 2017 DATE: 11 / 01 / 2021 DATE: 01 / 03 / 2019 Lot 9 Blk 3 Phase 1A Ponte Verde Royale REVISION:
OFFICE ADDRESS: # 703 J.P. RIZAL ST. CONCEPCION UNO MARIKINA CITY
PHONE NO. *02-5849396*09332106739*09182651216*
E-MAIL : mpdesign_associates@yahoo.com.ph I.A.P.O.A.: 0032019 PLACE: QUEZON CITY T.I.N.: 246-526-661 PLACE: MALOLOS BULACAN LOCATION: Subdivision, Brgy Cupang, Antipolo Rizal OWNER: DATE:

Вам также может понравиться