Вы находитесь на странице: 1из 3

METEY ENGINEERING AND CONSULTANCY Pvt Ltd

2-4-216, Road 9A, Snehapuri colony, New Nagole, Hyderabad-500035, INDIA


Tel: +91-9700159325, +91-9716100567, 040-33574835
PROJECT NAME JETCITY DESIGN ENGINEER NIKHIL

DESIGN OF HOLLOW CORE SLAB


INPUT
SECTION PROPERTIES

WIDTH OF HOLLOW CORE SLAB B = 1200 mm


OVERALL DEPTH OF HOLLOW CORE SLAB D = 265 mm
LENGTH OF SLAB L = 11900 mm
EFFECTIVE COVER OF HOLLOW CORE SLAB d' = 35 mm
NET AREA OF CONCRETE OF SLAB SECTION Ae = 161000 mm2
MOMENT OF INERTIA OF SLAB SECTION I = 1.42E+09 mm4
DISTANCE OF EXTREME TOP FIBRE IN COMPRESSION Yt = 133 mm
DISTANCE OF EXTREME BOTTOM FIBRE IN TENSION Yb = 132 mm

MATERIAL PROPERTIES

GRADE OF CONCRETE fck = 50 N/mm2


GRADE OF PRESTRESSING STRANDS fpu = 1820 N/mm2
DIAMETER OF PRESTRESSING STRANDS dia = 12.50 mm
NUMBER OF STRANDS no = 10 no

TOPPING PROPERTIES

TOPPING THICKNESS TTOPPING = 75 N/mm2


DISTANCE OF TOPPING CENTROID FROM BOTTOM OF HCS (Yb)TOPPING = 303 N/mm2
GRADE OF TOPPING CONCRETE (fck)TOPPING = 40 N/mm2

PRELIMINARY DESIGN

OUTPUT
EFFECTIVE DEPTH Deff = 230 mm
AREA OF PRESSTRESSING STRAND As = 98.71 mm2
SELF WEIGHT OF HOLLOW CORE SLAB w = 3.45 kN/m2
PERCENTAGE OF PRESTRESS (JACKING FORCE) % = 60 %
TOTAL INITIAL PRESTRESSING FORCE Fi = 1077.91 kN
PERCENTAGE CONCRETE STRENGTH AT TIME OF DE-STRESS % = 70 %
PERCENTAGE LOSS OF PRESTRESS % = 25 %
SECTION MODULUS TO TOP FIBRE Zt = 1.06E+07 mm3
SECTION MODULUS TO BOTTOM FIBRE Zb = 1.07E+07 mm3

OVERWRITE AND DESIGN

WITHOUT TOPPING
CALCULATION OF INITIAL CAMBER

ECCENTRICITY ABOUT CENTER e = 97.5 mm


YOUNG'S MODULUS OF CONCRETE Ec = 29580.4 N/mm2
NET THEORTICAL CAMBER VALUE δt = 33.31 mm
ALLOWABLE CAMBER δallowable = 47.6 mm

SLAB IS SAFE IN CAMBER


CALCULATION OF INITIAL STRESSES AT TRANSFER

MOMENT DUE TO SELF WEIGHT MDL = 73.28 kN.m


INITIAL STRESSES AT TOP FIBRE ft = 4.5 N/mm2
INITIAL STRESSES AT BOTTOM FIBRE fb = 5.54 N/mm2
STRENGTH OF CONCRETE DURING DE-STRESS fci = 35 N/mm2
ALLOWABLE COMPRESSIVE STRESS (fci)allowable = 16.62 N/mm2

SLAB IS SAFE IN RESISTING STRESS AT TRANSFER

CALCULATION OF MOMENT OF RESISTANCE

FACTOR (Aps*fpu)/(B*D eff*fck) = 0.13 no units


DEPTH OF NEUTRAL AXIS xu = 65.04 mm
TENSILE STRESS IN TENDON AT FAILURE fpb = 1583.4 N/mm2
MOMENT OF RESISTANCE MUR = 317.19 kN.m
SAFE LOAD CARRIED BY SLAB W = 6.33 kN/m2

6.33 kN/sqm is the safe load without topping


WITH TOPPING
COMPOSITE SECTION PROPERTIES

TOPPING AREA REDUCTION FACTOR n = 1.07 no units


EFFECTIVE AREA OF TOPPING (Aeff)TOPPING = 96214.05 mm2
CENTROID OF COMPOSITE SECTION FROM BOTTOM Y = 195.78 mm
DISTANCE OF EXTREME TOP FIBRE IN COMPRESSION Yt = 144.22 mm
DISTANCE OF EXTREME BOTTOM FIBRE IN TENSION Yb = 195.78 mm
MI OF HCS ABOUT CENTROID OF COMPOSITE SECTION (MI)HCS = 2.07E+09 mm4
MI OF TOPPING ABOUT CENTROID OF COMPOSITE SECTION (MI)TOPPING = 1.14E+09 mm4
MI OF COMPOSITE SECTION (MI)COMPOSITE = 3.21E+09 mm4
COMPOSITE SECTION MODULUS TO TOP FIBRE (Zt)COMPOSITE = 2.22E+07 mm3
COMPOSITE SECTION MODULUS TO BOTTOM FIBRE (Zb)COMPOSITE = 1.64E+07 mm3
EFFECTIVE DEPTH OF COMPOSITE SECTION (Deff)COMPOSITE = 305 mm

CALCULATION OF MOMENT OF RESISTANCE

FACTOR (Aps*fpu)/(B*D eff*fck) = 0.12 no units


DEPTH OF NEUTRAL AXIS xu = 81.29 mm
TENSILE STRESS IN TENDON AT FAILURE fpb = 1583.4 N/mm2
MOMENT OF RESISTANCE MUR = 423.85 kN.m
SAFE LOAD CARRIED BY SLAB W = 7.81 kN/m2

7.81 kN/sqm is the safe load with topping

CALCULATION OF SHEAR RESISTANCE (WITHOUT TOPPING)

PERCENTAGE OF TENSION REINFORCEMENT pp = 0.36 no units


GRADE OF CONCRETE fck = 50 N/mm2
DESIGN SHEAR STRENGTH OF CONCRETE ꞇC = 0.5 N/mm2
SHEAR RESISTANCE Vu = 138 kN
SAFE LOAD CARRIED BY SLAB W = 9.26 kN/m2

9.26 kN/sqm is the safe load without topping


CALCULATION OF SHEAR RESISTANCE (WITH TOPPING)

PERCENTAGE OF TENSION REINFORCEMENT pp = 0.27 no units


GRADE OF CONCRETE fck = 50 N/mm2
DESIGN SHEAR STRENGTH OF CONCRETE ꞇC = 0.44 N/mm2
SHEAR RESISTANCE Vu = 161.04 kN
SAFE LOAD CARRIED BY SLAB W = 9.54 kN/m2

9.54 kN/sqm is the safe load without topping

Вам также может понравиться