Вы находитесь на странице: 1из 7

1/30/2020 AutoDCR - CheckList

Check List Report Gorakhpur Development Authority


Version Number: 1.0.31
Version Date: 22/01/2020
Report Generated On: 30-01-2020
[-] Collapse All

[-] Proposal Information (Table 1)

General Details Schedule of boundaries


Site Address District:Gorakhpur,Tehsil:Gorakhpur,Village:NA Plot Use Residential
Authority Gorakhpur Development Authority Plot SubUse Detached Dwelling Unit (Single
AuthorityClass Category C House)

AuthorityGrade Development Authority (DA) Development


MALVIYA NAGAR
Plan
Inward_No GKDA/BP/19-20/0016
Land Use
Application Type General Proposal NA
Zone
CaseTrack Regular Layout Type NA
Project Type Building Permission  
Abutting
9.00
Nature of Road Width
NEW
Development
Development
Developed Area
Area
SubDevelopment
City Area
Area
Special Project NA
Site Address District:Gorakhpur,Tehsil:Gorakhpur,Village:NA

   
[-]Owner/Applicant details

Name Sri Santosh Chaubey S/O Late Ramanuj Chaubey


Email ID chaubey.santosh@gmail.com
Mobile No 8356005699

Name Smt. Madhavi chaubey W/O Sri Santosh Chaubey


Email ID madhveetiwari@gmail.com
Mobile No 8356005699

   
[-] Applicants Details

Name santosh kumar shahi


Validity 31/12/2020
EMAIL ID ar.santoshshahi@live.com
Mobile
9936732527
Number

 
[-] Plot Details (Table 2)
https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 1/7
1/30/2020 AutoDCR - CheckList

[-] Area From Document (Table 2a)


No. Form Area
1 Document Area 160.00
2 Area as per Drawing 160.00
Minimum area of Plot Considered : 160.00
[-] Table 2b
Proposal Detail
Unit
Development Detail
Plot Plot
Plot Use Residential
Plot Sub Use Row House
Gross Plot Area 160.00
Net Plot Area (Gross Plot Area - Deduction from Gross 160.00
Plot area)

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 71.25 %) 114.00
        Previous Coverage area ( 75.00 %) 75.00
        Current Coverage area ( 65.00 %) 39.00
Proposed Coverage Area ( 58.56 %) 93.70
Total Prop. Coverage Area ( 58.56 %) 93.70
Balance coverage area ( 12.69 %) 20.30
FAR CHECK
    Perm. FAR Area ( 1.91 ) 305.00
        Previous Perm. FAR Area ( 2.00 ) 200.00
        Current Perm. FAR Area ( 1.75 ) 105.00
Total Perm. FAR area 305.00
    Residential FAR 263.13
Total Building FAR Area 263.13
Total Proposed FAR Area 263.13
Consumed FAR (Factor) 1.64
Balance FAR Area 41.87
BUA CHECK
Total BuiltUp Area 275.64

Approved Layout Details


Layout Approved Details
Layout Approved Common COP Provided Common Parking Provided
Yes No No

[-] Check List


Name Description Unit Reqd Perm Proposed Status
[-] Plot Details
PLOT Plot Area Sq.Mt. 40.00 - 160.00 OK
Plot Width Sq.Mt. 3.50 - 10.00 OK
Plot Depth Sq.Mt. - - 16.00 OK
Access Width Sq.Mt. 9.00 - 9.00 OK
https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 2/7
1/30/2020 AutoDCR - CheckList
Plot Frontage Sq.Mt. - - 10.00 OK
Coverage Area Sq.Mt. - 114.00 93.70 OK
FAR Area Sq.Mt. - 305.00 263.13 OK
Additional FAR Area Sq.Mt. - - - OK
FOC FAR Area Sq.Mt. - - - OK
Consumed FAR Sq.Mt. - 1.91 1.64 OK
[-] Tree
Tree Plot - Tree - Nos Of Trees No. 1 2 OK
[-] Parking
Equivalent Car Space In Area Sq.Mt. - - 13.75 OK
Equivalent Car Space-No. No. - - 1.00 OK
Total Car In Area Sq.Mt. 13.75 - 13.75 OK
Total Car-No. No. 1.00 - 1.00 OK
[-] PWork to Plot Setback
A-1 (TSB) Front Margin... 9.00 MT. WIDE ROAD Mt. 5.00 - 3.00 Failed
Rear Margin Mt. 5.00 - 1.00 Failed
Side1 Margin Mt. 5.00 - 0.00 Failed
Side2 Margin Mt. 5.00 - 1.20 Failed
[-] Building Height
A (TSB) Height Mt. 10.50 10.80 Failed
Length Mt. - 12.00 OK
Height Mt. 10.80 OK
[-] Floor Height
A (TSB) Parapet at Terrace Floor - Height Mt. - - 0.90 OK
Parapet at Terrace Floor - Clear
Mt. 2.75 - 0.90 Failed
Height
Second Floor - Height Mt. - - 3.15 OK
Second Floor - Clear Height Mt. 2.75 - 3.04 OK
First Floor - Height Mt. - - 3.15 OK
First Floor - Clear Height Mt. 2.75 - 3.04 OK
Ground Floor - Height Mt. - - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.04 OK
Plinth - Height Mt. 0.30 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
[-] Floors Number
A (TSB) No. of Floors No. G+2 G+3 Failed
No. of Tenements No. 1 1 OK
[-] Arch. Projection and Balcony
A (TSB) GROUND FLOOR PLAN - Front Setback
Mt. 5.00 7.00 Failed
- Total Area
GROUND FLOOR PLAN - Rear Setback
Mt. 5.00 4.80 OK
- Total Area
FIRST FLOOR PLAN - Front Setback -
Mt. 5.00 6.28 Failed
Total Area
FIRST FLOOR PLAN - Rear Setback -
Mt. 5.00 4.80 OK
Total Area
SECOND FLOOR PLAN - Front Setback
Mt. 5.00 6.28 Failed
- Total Area
SECOND FLOOR PLAN - Rear Setback
Mt. 5.00 8.80 Failed
- Total Area
[-] Stair Count Details
A (TSB) GROUND FLOOR PLAN - Number Of
No. 1 1 OK
Common Stair(s)
GROUND FLOOR PLAN - Number Of
No. - - OK
Fire Stair(s)
https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 3/7
1/30/2020 AutoDCR - CheckList

FIRST FLOOR PLAN - Number Of No. 1 1 OK


Common Stair(s)
FIRST FLOOR PLAN - Number Of Fire
No. - - OK
Stair(s)
SECOND FLOOR PLAN - Number Of
No. 1 1 OK
Common Stair(s)
SECOND FLOOR PLAN - Number Of
No. - - OK
Fire Stair(s)
TERRACE FLOOR PLAN - Number Of
No. 1 1 OK
Common Stair(s)
TERRACE FLOOR PLAN - Number Of
No. - - OK
Fire Stair(s)
[-] Stair Details
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 1.00 1.00 OK
STAIRCASE - Tread Width Mt. 0.25 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. 0.19 0.175 OK
STAIRCASE - Riser No. On Flight No. 12 6 OK
STAIRCASE - Intermediate Landing
Mt. 1.00 1.00 OK
Width
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Railing Ht. Mt. 0.85 - 1.00 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 1.00 1.00 OK
STAIRCASE - Tread Width Mt. 0.25 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. 0.19 0.175 OK
STAIRCASE - Riser No. On Flight No. 12 6 OK
STAIRCASE - Intermediate Landing
Mt. 1.00 1.00 OK
Width
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Railing Ht. Mt. 0.85 - 1.00 OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 1.00 1.00 OK
STAIRCASE - Tread Width Mt. 0.25 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. 0.19 0.175 OK
STAIRCASE - Riser No. On Flight No. 12 6 OK
STAIRCASE - Intermediate Landing
Mt. 1.00 1.00 OK
Width
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Railing Ht. Mt. 0.85 - 1.00 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.00 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. 12 - OK
STAIRCASE - Intermediate Landing
Mt. - 1.00 OK
Width
STAIRCASE - Cabin Ht. Mt. 2.10 - 2.40 OK
STAIRCASE - Railing Ht. Mt. - - 1.00 OK
[-] Arch Projection Details
A (TSB) GROUND FLOOR PLAN - CHHAJJA -
Mt. 1.50 1.00 OK
Width
GROUND FLOOR PLAN - CHHAJJA -
Mt. - 1.20 OK
PlotDist
GROUND FLOOR PLAN - CHHAJJA -
Mt. - - - OK
Height

https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 4/7
1/30/2020 AutoDCR - CheckList

GROUND FLOOR PLAN - CHHAJJA - Mt. 1.50 1.00 OK


Width
GROUND FLOOR PLAN - CHHAJJA -
Mt. - - OK
PlotDist
GROUND FLOOR PLAN - CHHAJJA -
Mt. - - - OK
Height
FIRST FLOOR PLAN - CHHAJJA - Width Mt. 1.50 1.00 OK
FIRST FLOOR PLAN - CHHAJJA - PlotDist Mt. - - OK
FIRST FLOOR PLAN - CHHAJJA - Height Mt. - - - OK
FIRST FLOOR PLAN - CHHAJJA - Width Mt. 1.50 1.00 OK
FIRST FLOOR PLAN - CHHAJJA - PlotDist Mt. - 1.20 OK
FIRST FLOOR PLAN - CHHAJJA - Height Mt. - - - OK
SECOND FLOOR PLAN - CHHAJJA -
Mt. 1.50 1.00 OK
Width
SECOND FLOOR PLAN - CHHAJJA -
Mt. - - OK
PlotDist
SECOND FLOOR PLAN - CHHAJJA -
Mt. - - - OK
Height
SECOND FLOOR PLAN - CHHAJJA -
Mt. 1.50 1.00 OK
Width
SECOND FLOOR PLAN - CHHAJJA -
Mt. - - OK
PlotDist
SECOND FLOOR PLAN - CHHAJJA -
Mt. - - - OK
Height
[-] Miscellanies Checks
No Rule Status
1 Detached type of Building shall not be allowed in less than 500 sq.mt. Plot
Failed
area
[-] Room Details
  [-] Building : A (TSB)
  [-] Floor : GROUND FLOOR PLAN
Area Width Depth Ventilation
Tnmt No. Room Name Status
Reqd Perm Prop Reqd Prop Reqd Prop Reqd Prop
BED ROOM 9.50 - 15.79 2.40 3.54 - 4.46 1.58 2.16 OK
BED ROOM 9.50 - 11.51 2.40 2.46 - 4.69 1.15 2.16 OK
TOILET 2.80 - 4.88 1.20 1.50 - 3.25 0.30 0.90 OK
SPLIT TSB BED ROOM 9.50 - 12.74 2.40 3.54 - 3.60 1.27 2.16 OK
KITCHEN 5.00 - 6.68 1.80 2.32 - 2.89 1.00 1.44 OK
LOUNGE - - 13.73 - 3.25 - 4.23 - 0.00 OK
ENTRANCE 9.50 - 3.84 2.40 1.28 - 3.00 0.38 1.44 Failed

[-] Floor : FIRST FLOOR PLAN


Area Width Depth Ventilation
Tnmt No. Room Name Status
Reqd Perm Prop Reqd Prop Reqd Prop Reqd Prop
BED ROOM 9.50 - 15.79 2.40 3.54 - 4.46 1.58 2.16 OK
BED ROOM 9.50 - 11.51 2.40 2.46 - 4.69 1.15 2.16 OK
TOILET 2.80 - 4.88 1.20 1.50 - 3.25 0.30 0.90 OK
SPLIT TSB
BED ROOM 9.50 - 12.74 2.40 3.54 - 3.60 1.27 2.16 OK
LOUNGE - - 13.73 - 3.25 - 4.23 - 2.16 OK
BALCONY - - 11.69 - 2.43 - 4.80 - 2.16 OK

[-] Floor : SECOND FLOOR PLAN


Area Width Depth Ventilation
Tnmt No. Room Name Status
Reqd Perm Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT TSB BED ROOM 9.50 - 8.71 2.40 2.46 - 3.54 0.87 2.16 Failed
BED ROOM 9.50 - 11.51 2.40 2.46 - 4.69 1.15 2.16 OK
TOILET 2.80 - 4.88 1.20 1.50 - 3.25 0.30 0.90 OK
BED ROOM 9.50 - 12.74 2.40 3.54 - 3.60 1.27 2.16 OK
https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 5/7
1/30/2020 AutoDCR - CheckList
LOUNGE - - 13.73 - 3.25 - 4.23 - 2.16 OK
BALCONY - - 11.69 - 2.43 - 4.80 - 2.16 OK

NOTE : Based on the aforesaid permission the applicant reserves the rights to commence the construction from
the day of issuance. Nevertheless; in case, for procuring the aforesaid permission, any document or system
configuration for rules or information or parameters or drawings provided or attached is found to be incorrect or
inconsistent with respect to prevailing bye-laws, by any authority or otherwise, the permission granted shall be
considered as lapsed.

[-] Rules
Topic Rule
Plot Level
Plot Area For any Residential use, plot area shall be mini. 40.00 sq.mt and Mini. Plot Width shall be 3.50
mt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Plot Width For any Residential use, plot area shall be mini. 40.00 sq.mt and Mini. Plot Width shall be 3.50
mt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Plot Depth For any Residential use, plot area shall be mini. 40.00 sq.mt and Mini. Plot Width shall be 3.50
mt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Access Width For Existing BuitUp Area/Developed Area in Multi Residential Units, The width of the main
abutting road shall not be less than 9.0 mt. {Building Construction and Development By-Laws
2018, Rule No. 26.2 and 26.3}
Plot Frontage For any Residential use, plot area shall be mini. 40.00 sq.mt and Mini. Plot Width shall be 3.50
mt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Coverage Area For Residential use, in location Existing Built Up Area/Developed Area ,if plot area is between
100-300 sq mt. then Max.Coverage shall be 65% applicable{Building Construction and
Development By-Laws 2018, Rule No.3.5.1.(1)}
FAR Area (1) For Residential use, in location Existing Built Up Area/Developed Area ,if plot area is
between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and
Development By-Laws 2018, Rule No.3.5.1.(1)}
(2) For Residential use, in location Existing Built Up Area/Developed Area ,if plot area is
between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and
Development By-Laws 2018, Rule No.3.5.1.(1)}
(3) In case of Constructed, Developed or New/ Undeveloped areas, purchasable FAR is
permissible only if the plot is abutting a road of 18 m width or above {Rule No. 3.5.2.1}
Consumed FAR (1) For Residential use, in location Existing Built Up Area/Developed Area ,if plot area is
between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and
Development By-Laws 2018, Rule No.3.5.1.(1)}
(2) For Residential use, in location Existing Built Up Area/Developed Area ,if plot area is
between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and
Development By-Laws 2018, Rule No.3.5.1.(1)}
(3) In case of Constructed, Developed or New/ Undeveloped areas, purchasable FAR is
permissible only if the plot is abutting a road of 18 m width or above {Rule No. 3.5.2.1}
Tree Number For the residential Use, for plot area up to 200 sq.mt.,one tree shall be required. {As per Building
Construction and Development By-Laws 2018, rule no. 3.1.2.2}
Equivalent Car Space FOR RESIDENTIAL BUILDING, FOR PLOT AREA 100-200 SQ. MT. ONE CAR SHALL BE REQUIRED {AS
Parking Check PER BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018, RULE NO.3.10}
Total Car Parking FOR RESIDENTIAL BUILDING, FOR PLOT AREA 100-200 SQ. MT. ONE CAR SHALL BE REQUIRED {AS
Check PER BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018, RULE NO.3.10}
Margin Rule For All Except Commercial building, min front 5.0 , rear 5.0 ,side1 5.0 and side2 5.0 shall be
required. {Building Construction and Development By-Laws 2018.rule no. 3.4.5}
Building Level
Building Height For Residencial Use, Maximum Height of construction shall be 10.50 mts (For Building without
stilt/parking floor) from the level of the Building Unit.{Building Construction and Development
By-Laws 2018, 3.4.1 }
Floor Height (1) For any Habitable Floor, minimum Floor height shall be 2.75 mts.{Building Construction and
Development By-Laws 2018,}
(2) The plinth of the habitable area of any building shall be at a minimum height of 0.30mts
from the established level of the building unit {Building Construction and Development By-Laws
2018, Rule No. 3.6.5, Page 51}

https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 6/7
1/30/2020 AutoDCR - CheckList

Floor Number For any Residential Single Dwelling unit without stilt Maximum Height of construction shall be
10.50 mts having max G+2 floor from the level of the Building Unit.{Building Construction and
Development By-Laws 2018, 2.5.1.7 }
StairCase Count For any building having more than one Ground floor, Mini. one staircase has to be provided
StairCase (1) For Residential Building,stairwidth shall be mini. 1.0 mt. with max riser upto 0.19 mt. and min.
tread upto 0.25 mt.{Building Construction and Development By-Laws 2018, Rule No.3.8.1, Page
54}
(2) -
(3) For nay Residential Building, The number of risers shall be 12.00 per flight for Stairs.{Building
Construction and Development By-Laws 2018,}
(4) For Residential Building,stairwidth shall be mini. 1.0 mt.,Cabinate Height shall be minimum
2.1 mt.{Building Construction and Development By-Laws 2018, Rule No.3.8.1, Page 54}
(5) -
(6) For nay Residential Building, The number of risers shall be 12.00 per flight for Stairs.{Building
Construction and Development By-Laws 2018,}
Arch Projection (1) -
(2) -
(3) For Building, Perm. width for Arch Proj/ Chhajja/ Balcony/ Roof Projection shall be 1.5 mt. or
1/2 of Prop. Open space (Whichever is less) and Perm. Area shall be Max. 10% open area.
Building Level (Rooms)
Balcony No rule defined{Building Construction and Development By-Laws 2018, Rule No.3.6.1}
Bed Room Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and
Development By-Laws 2018, Rule No.3.6.1}
Entrance Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and
Development By-Laws 2018, Rule No.3.6.1}
Kitchen Minimum size of Kitchen room shall be 5.00 sq. mt.{Building Construction and Development By-
Laws 2018,}
Lounge No rule defined{Building Construction and Development By-Laws 2018, Rule No.3.6.1}
Toilet Minimum size of Bath +WC room shall be 2.80 sq. mt.{Building Construction and Development
By-Laws 2018}

https://upobpas.in/AutoDCR.Common2/CommonPages/printReport.aspx?iProposalId=2982&iVal=1 7/7