Вы находитесь на странице: 1из 55

Low Voltage

EasyPact MVS
LV power circuit breakers and switch-disconnectors 800 to 4000A

Catalogue
2018
Performance without compromise

Exceptional Quality and safety Outstanding value for an reliability,flexibility you can
trust optimized feature set and convenience

Buildings Industry Panelbuilders


EasyPact MVS range
The easy choice for reliable
performance
> Performance without compromise > Assured quality and safety you can trust
> Deliver exceptional reliability and flexibility in its class > Outstanding value
for an optimized feature set > Precision engineered to meet your needs >
Unbeatable value throughout its lifecycle > Simple to choose and easy to install
Choose the leader
> 800 to 4000A ratings > Breaking capacity: 50 & 65kA > Suitable for 690V
applications > Complete selectivity with Ics=Icu=Icw (1 s) > Intelligent ET range
of trip system with display > Fully protected neutral on 4 pole breakers >
Common accessories for complete range > Conforms to IEC 60947- 2 & 3
EasyPact
MVSBenefits for
every
customer
EasyPact MVS08 to MVS40
The Key values

The performance you need


EasyPact MVS provides the ideal level of capability for your installation from 800 to
4000 A.
At a cost-effective investment
Pay for what you need: Get outstanding durability with the features you need, with the
benefit of easy to order and stock.
With the quality you demand
Designed and manufactured by Schenider Electric using advanced manufacturing methods
and premium materials.
Gain peace ofmind and
optimised cost for every
installation
With Green Premium, Schneider Electric commits to be transparent
disclosing extensive and reliable information on environmental
impacts of its products:

Green Premium is the only label allowing you to develop effectively an environmental policy
and to promote it, while preserving your business efficiency.

It guarantees compliance with the most up-to-date environmental regulations, but it is more
than this.

With Green Premium eco-mark, Schneider Electric helps you:


• Calculate the carbon footprint of
the solutions you offer
• Ensure full regulation compliance about
substances and chemical components
• Deliver all appropriate information
to certify eco-design of your solutions
• Easily manage products end of life,
while ensuring optimized recycling.
Discover what we mean by green …. and
CheCk a ProDuCt!
Functions Overview of functions
and characteristics
ETA trip system
ETA trip units include all functions offered by ET trip unit. successively pressing the navigation button.
In addition, they also offer measurements, display The optional external power supply makes it possible to display currents < 20 % In.
and current maximeters. Below 0.1 In, measurements are not significant. Between 0.1 and 0.2 In, accuracy
changes linearly from 4 % to 1.5 %.
Protection
Protection thresholds and delays are set using the adjustment dials.
Overload protection
True rms long-time protection. Protects cables (phase and neutral) against overloads
(1)
Thermal memory : thermal image before and after tripping .
Short-time protection
b The short-time protection function protects the distribution
system against impedant short-circuits b The short-time
tripping delay can be used to ensure discrimination with
t ON and I t OFF
downstream circuit breaker b The I
2 2

options enhance discrimination with a


downstream
protection devices b Use of I t curves with short-time protection: v I t
2 2

OFF selected: the protection function implements a constant


time curve v I t ON selected: the protection function
2

implements an I t inverse-time curve up to


2

10 lr. Above 10 lr, the time curve is constant


Earth-fault protection on ETA6G trip system
Residual earth fault protection. Selection of I t type (ON or OFF) for delay .
2

A ground fault in the protection conductors can provoke local temperature rise at the
site of the fault or in the conductors. The purpose of the ground-fault protection
function is to eliminate this type of fault.

Instantaneous protection
The Instantaneous-protection
Typ Description function protects the distribution system against solid
eshort-circuits. Contrary to the short-time protection function, the tripping delay for
Resi b The function
instantaneous determines
protection the
is not adjustable. The tripping order is sent to the circuit
dual zero-phase
breaker as soon assequence current, the set value, with a fixed time delay of
current exceeds
i.e. the
20 milliseconds.
Neutral protection
On three-pole circuit breakers, neutral protection is not possible. On four-pole circuit
breakers, neutral protection may be set using a three-position switch: neutral
unprotected (4P 3d), neutral protection at 0.5 Ir (4P 3d + N/2), neutral protection at Ir
(4P 4d).
Zone selective interlocking (ZSI)
A ZSI terminal block may be used to interconnect a number
(2)

of control units to provide total discrimination for short-time


1 Long-time threshold and tripping delay. 2 Overload alarm (LED)
at 1,125 Ir. 3 Short-time pick-up and tripping delay. 4 and earth-fault protection, without a delay before tripping.
Instantaneous pick-up. 5 Earth-fault pick-up and tripping delay. 6
Earth-fault test button. 7 Long-time rating plug screw. 8 Test Overload alarm
connector. 9 Lamp test, reset and battery test. 10 Indication of A yellow alarm LED goes on when the current exceeds the long-time trip threshold.
tripping cause. 11 Digital display. 12 Three-phase bargraph and
ammeter. 13 Navigation button to view menu contents. 14 Fault indications
Navigation button to change menu. LEDs indicate the type of fault: b Overload (long-time protection Ir) b Short-circuit
(short-time Isd or instantaneous li protection) b Earth fault (Ig) b Internal fault (Ap)
(1) The thermal memory continuously accounts for the amount of Battery power
heat in the cables , both before and after tripping , whatever the
value of the current(presence of an overload or not).The thermal The fault indicating LEDs are powered by an in-built battery. The fault indication
memory optimises the long-time protection function of the circuit LEDs remain on until the test/reset button is pressed.
breaker by taking into account the temperature rise in the
cables .The thermal memory assumes a cable cooling time of Test
approximately 20 minutes. A hand-held test kit may be connected to the test connector on the front to check
(2) Refer to page D-5 for more details on ZSI. circuit-breaker operation. For ETA6G trip unit, the operation of earth-fault protection
can be checked by pressing the test button located above the test connector.
Note: ETA trip units come with a transparent leadseal cover as
standard.
“Ammeter” measurements
ETA trip units measure the true (rms) value of currents.
They provide continuous current measurements from 0.2
to 1.2 In and are accurate to within 1.5 % (including the
sensors).
A digital LCD screen continuously displays the most
heavily loaded phase (Imax) or displays the I1, I2, I3, IN, Ig,
stored-current (maximeter) and setting values by
Time setting tr (s) 0.51 2 4 8 12162024
1 2 4 8 12162024 Accuracy:
Time delay (s) Accuracy: 0 to -30 % 1.5 x Ir 12.5 25 50 100 200 300 400 500 600 Accuracy: 0 to -20 % 6 x Ir 0.7
(1)

0 to -20 % 7.2 x Ir 0.7 0.69 1.38 2.7 5.5 8.3 11 13.8 16.6
(2)

DB1
011
Thermal memory 20 minutes before and after tripping
26 (1) 0 to -40 % - (2) 0 to -60 %
L Instantaneous Pick-up (A) Isd = Ir x … 1.52 2.53 4 5 6 8 10 Accuracy: ±10 %
o Time delay Max resettable time: 20 ms Max break time: 80 ms
n
g
ti
m Long time
e
ETA5S/ETA6G Current setting (A) Ir = In x … 0.4 0.5 0.6 0.7 0.8 0.9 0.95 0.98 1 Tripping between 1.05 and 1.20 x Ir

E
T
A
2I
Cu
rre
nt
se
tti
ng Time setting tr (s) 0.51 2 4 8 12162024
(A Time delay (s) Accuracy: 0 to -30 % 1.5 x Ir 12.5 25 50 100 200 300 400 500 600 Accuracy: 0 to -20 % 6 x Ir 0.71 2 4 8 12162024 Accuracy:
(1)

) Ir
0 to -20 % 7.2 x Ir 0.7 (2)
0.69 1.38 2.7 5.5 8.3 11 13.8 16.6
= Thermal memory 20 minutes before and after tripping
In (1) 0 to -40 % - (2) 0 to -60 %
x. Short time Pick-up (A) Isd = Ir x … 1.52 2.53 4 5 6 8 10 Accuracy: ±10 %
..
Time setting tsd (s) Settings It Off 0 0.1 0.2 0.3 0.4 I t On -0.1 0.2 0.3 0.4
2 2

0.
Time delay (ms) at 10 x Ir tsd (max resettable time) 20 80 140 230 350 (I t Off or I t On) tsd (max break time) 80 140 200 320 500 Instantaneous
2 2
4
0. Pick-up (A) Ii = In x … 2 3 4 6 8 101215off Accuracy: ±10 %
5 Time delay Max resettable time: 20 ms Max break time: 50 ms
0. Earth fault
6
0. ETA6G Pick-up (A) Ig = In x … A BCDE F GHJ Accuracy: ±10 % In y400 A 0.3 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
7 400 A < In y1000 A 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
0. In u1250 A 500 640 720 800 880 960 1040 1120 1200
8
0.
9
0.
95
0.
98
1 Time setting tg (s) Settings I
2
t Off 0 0.1 0.2 0.3 0.4 I t On -0.1 0.2 0.3 0.4
2

Tri Time delay (ms) tg (max resettable time) 20 80 140 230 350
pp
in
g
be at In or 1200 A (I
2
t Off or I t On) tg (max break time) 80 140 200 320 500
2

tw Type of measurements
ee
n
Range
1.
05 Accuracy
an Instantaneous currents I1, I2, I3, In 0.2 x In to 1.2 x In ± 1.5 % Ig (ETA6G) 0.2 x In to In ± 10 %
d
1.
20
x
Ir
Current maximeters of I1, I2, I3, In 0.2 x In to 1.2 x In ± 1.5 %
Note: All current-based protection functions require no auxiliary source. The test / reset button resets maximeters, clears the tripping indication and tests the
battery.
Remote operation
Remote ON / OFF
MX voltage releases. XF voltage release.

Electric motor MCH for EasyPact MVS.

Operating 0.85 to 1.1


threshold Un
Consumpt
ion (VA or 180
W)
Motor
2 to 3 In for
overcurre
0.1 s
nt
Electric motor
Charging MCH
The electric motor automatically charges and recharges the spring mechanism when the
circuit breaker is closed. Instantaneous reclosing of the breaker is thus possible following
opening. The spring-mechanism charging handle is used only as a backup
if auxiliary power is absent.
The electric motor MCH is equipped as standard with a limit switch contact CH that
signals the “charged” position of the mechanism (springs charged).
Characteristics
Power supply V AC 50/60 Hz 100/130 - 200/240 - 380/415 V DC 24/30 - 48/60 -
100/125 - 200/250

Operating 0.85 to 0.7 to


Voltage releases 1.1
threshold XFUnand MX
1.1 Un
Consumption
Their supply can be maintained Hold:
Hold: 4.5 or automatically disconnected.
Closing (VA or W) XF
release 4.5
Pick-up: Pick-up:
The XF release remotely closes
200 (200 the
200circuit breaker if the spring mechanism is
charged.
Opening release MX
The MX release instantaneously opens the circuit breaker when energised. It locks the
circuit breaker in OFF position if the order is maintained.
Characteristics XF MX
Power supply V AC 50/60 Hz 24 - 48 - 100/130 - 200/250 - 380/480
V DC 12 - 24/30 - 48/60 - 100/130 - 200/250

“Ready to close” contact PF


The “ready to close” position of the circuit breaker is indicated by a mechanical indicator
and a PF changeover contact. This signal indicates that all the following are valid: b The
circuit breaker is in the OFF position b The spring mechanism is charged b A maintained
opening order is not present: v MX energised v Fault trip v Remote tripping MN v Device
not completely racked in v Device locked in OFF position v Device interlocked with a
second device
Characteristics
Maximum number 1
Breaking capacity (A) Standard Minimum
load: 100 mA/24 V
p.f.: 0.3 V AC 240/380 5 AC12/DC12 480 5 690 3
V DC 24/48 3 125 0.3 250 0.15
“Ready to close” contacts PF.
Functions

R operati
e on
m and characteristics

Characteristics
o Rem
Power supply
V AC
50/6 t
24 - 48 - 100/130 - ote
200/250 - 380/480
0 Hz
trippi
DC
V
- 200/250e
24/30 - 48/60 - 100/130

ng
MN voltage Operating Ope 0.35 to 0.7 Un
056422
release. threshold ning
N
DB100
stantaneous voltage releases Closi MNUn
0.85
809-16 The MN release instantaneouslyng opens the circuit breaker when its supply voltage drops to a value between 35 % and 70 % of its rated
Consumption (VA or W) Pick-up: Hold: 4.5
voltage. If there is no supply on the release, it is impossible to close the circuit breaker, either manually or electrically. Any attempt to close
200 (200
the circuit breaker has no effect on the main
ms) contacts. Circuit breaker closing is enabled again when the supply voltage of the release
returns to 85% of its rated value.

Pick-up:
Hold
MN delay unit. Delay unit consumption 200 (200
: 4.5
ms)
Circuit-breaker response Non- 0.25 s

MN delay units
To eliminate circuit-breaker nuisance tripping during short voltage dips, operation of
the MN release can be delayed. This function is achieved by adding an external
In delay unit in the MN voltage-release circuit. Two versions are available, adjustable and non-adjustable.
Characteristics
Power supply Non-adjustable 100/130 - 200/250 V AC 50-60 Hz /DC Adjustable 48/60 - 100/130 - 200/250 - 380/480
Operating threshold Opening 0.35 to 0.7 Un Closing 0.85 Un
Dimensions and
connection
EasyPact MVS Dimensions and connection

Functions and characteristics A-1 Installation recommendations B-


1

MVS08 to MVS32 circuit breakers C-2


Fixed 3/4-poles device C-2
Draw-out 3/4-poles device C-4

MVS40 circuit breakers C-6


Fixed 3/4-poles device C-6
Draw-out 3/4-poles device C-8

Accessories C-10
External modules C-11

Electrical diagrams D-1 Additional characteristics E-1 Catalogue numbers and order form F-1
Dimensions MVS08 to MVS32 circuit breakers
and connection
DB101271DB101269DB101267
Fixed 3/4-poles device

DB101270

CDB500019
(1) Without escutcheon.
(2) With escutcheon. Note: X and Y are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 50 mm is required to remove the arc chutes.

: Datum.
An overhead clearance of 20 mm is required to remove the terminal block.

Ins Met En
ula al erg
ted ise
d
par par par
DB101279 DB101274

DB101280

DB101282 DB101287
View A detail.
Note: Recommended connection screws: M10 class 8.8. Tightening torque: 50 Nm with contact washer.
Dimensions MVS08 to MVS32 circuit breakers
and connection
DB101293DB101291DB101289
Draw-out 3/4-poles device

DB101295

DB101292

CDB500021
(*) Disconnected position.
(1) Without escutcheon.
Ins Met En
ula al erg (2) With escutcheon.
: Datum. ted ise
d Note: X and Y are the symmetry planes for a 3-pole device.
par par par
CDB
5000 Horizontal rear connection Detail
45 DB101301
CDB DB101297
5000 DB101282 DB101307
44

C
o
n
n
e
ct
io
n
s

DB101278 DB101298

Vertical rear connection Detail


Vi A detail.
ew Note: Recommended connection screws: M10 class 8.8. Tightening torque: 50 Nm with contact washer.
Dimensions MVS40 circuit breakers
and connection
DB10127
Fixed 3/4-poles device
1DB1012 nting detail
69DB101
267

Safety clearances Door cutout

DB10127
0
CDB500019

(1) Without escutcheon.


(2) With escutcheon. Note: X and Y are the symmetry planes for a 3-pole device. A(*) An overhead clearance of 110 mm is required to remove the arc chutes.

: Datum.
An overhead clearance of 20 mm is required to remove the terminal block.

Mou Ins Met En


ntin ula al erg
g ted ise
on d
bas par par par
e
plat
e or
rails
Mou
DB10131
2
DB10130
9DB1012
87
DB10131
3

DB10127
6

Note: Recommended connection screws: M10 class


8.8. Tightening torque: 50 Nm with contact washer.
Dimensions MVS40 circuit breakers
and connection
DB1012
Draw-out 3/4-poles device
93DB10 e plate or rails Mounting detail
1291DB
101289

Safety clearances Door cutout

(*)
Disc
onne
cted
posit
ion.

Mou
ntin
g
on
bas
: Datum. (2) With escutcheon. Note: X and Y are the symmetry planes for a 3-pole device.
(1) Without
escutcheon. The safety clearances take into account the space required to remove the arc chutes.

Ins Met En
ula al erg
ted ise
d
par par par
CDB5000
47 Horizo 15 DB101315DB101311
View A
N c d connection
CDB5000
ntal 4 o detail. o screws: M10
46
Detail t m class 8.8.
Co rear 0 Vertical e m Tightening
conne 0(
nne ction
rear : e torque: 50
3 connect n Nm with
ctio DB101319
P) R d contact
ion
ns Detail
CDB500050DB101297
DB101314
DB101307 e e washer.
Dimensions Accessories
and connection
DB101350

DB101351
DB101375DB102 DB101368
077 Connectio One
n of conductor
only per
auxilary connection
wiring to point.
terminal External power supply module (AD)
block
DB117025

DB102076

DB101367

External
modules
Delay unit for MN release
Dimensions External modules
and connection

DB101386DB117024
Dimensions 400/2000 A (MVS08 to MVS20) 1000/4000 A (MVS25 to MVS40)

High: 162 mm.


High: 162 mm.
Installation
400/2000 A 1000/4000 A
(MVS08 to (MVS25 to
MVS20) MVS40)

DB101387
Catalogue numbers and
order form
umbersand order form

Functions and characteristics A-1 Installation recommendations B-


1 Dimensions and connection C-1 Electrical diagrams D-1 Tripping
curves E-2

Nomencl
ature F-2
EasyPact MVS F-3
Connection F-3 ET Trip System & accessories F-4 Remote operation F-5 Chassis locking and accessories F-7 Clusters F-8 Circuit breaker locking
and accessories F-9 Mechanical interlocking for source changeover F-10 Indication contacts F-11 Instructions F-12

Order form F-13


Catalogue numbers Nomenclature and order form

0 N 3 M F 2 L
8
1 4
H N W 5 A
0
1
O 6 V
2 EasyPact MVS (from 800 to 4000A) Icu=Ics=Icw (1 sec)=50kA & 65kA
1
P 0 D
6
2
Q
0
2
R
5 Type Basic
3 protection
S
Protection+c
urrent
1L metering
1
3 2 1 1 1 1 AV Protection+v
D oltage
metering
Switch
disconnecto
r
Protections No. LI
protection LSI
protection LSIG
protection No
Example 2 MVS16H3MF0D protection for
2 5 6 0H3M F0 D
MVS16 switch disconnector
Type of installation Fixed
FW Draw-out
Operating
mechanism
Manually Switch disconnector
operated
ACB/SD
Electrical
200/240
VAC
Electrical
110/130
VAC
Electrical
380/415
VAC
Electrical
200/250
VDC
Electrical MCH + XF + MX
100/125 MCH + XF + MX
VDC MCH + XF + MX
Electrical MCH + XF + MX
MNO 48/60V DC MCH + XF + MX
PQRS Electrical MCH + XF + MX
T 24/30V DC MCH + XF + MX
Numbe
r of
poles 3
Poles 4
3P 4P Poles
Type based on breaking capacity Circuit
breaker/ switch disconnector
Icu=Ics=Icw(1sec)=50kA Circuit breaker/ switch
NH disconnector Icu=Ics=Icw(1sec)=65kA
08 Current rating 800A 1000A 1250A 1600A 2000A 2500A
10 3200A 4000A
12
16
20
25
32
40
E
xa
m
pl M MVS32N
e V 4EW6L 4
1 S 32 N E W 6 L
Catalogue numbers EasyPact MVSand order form
Connection 3
P 4
P
4 4
7 7
9 9
6 6
4 5
4 4
7 7
9 9
E46428 E46446 E46445 E46446 E46445
6 6
4 5 Horizontal
Fixed circuit breakers Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts) mounting.
Installation
MVS2 manual
1735
800-2000 A Vertical Horizontal
4
2500/3200 A Vertical Horizontal 7 Interphase
9 barriers /
Vertical mounting.
6 Replacement kit
4000 A Vertical Horizontal 5
(3 parts)
4
7
9
6
Horizontal mounting. 5
Installation manual MVS21735
Draw-out circuit breakers Rear connection (vertical or horizontal mounting) / Replacement kit (3 or 4 parts)

800-2000 A Vertical Horizontal


4859 4859
2500/3200 A Vertical Horizontal For fixed rear-connected circuit breaker
9 9
Vertical mounting. For draw-out rear-connected circuit 4860 4860
breaker 0 0
4000 A Vertical Horizontal
ET Trip System & accessories

Battery + cover Hand held test


B 33594
a
t
t
e
r
y

(
1 CD
B50
003
p External sensors External sensor for earth-fault protection (TCE) / 1 part 8
DB1
a 053
60E
r 466
t 71E
955
) Sensor rating 400/2000 A 40

24-30 V DC 54440
33593
48-60 V DC 54441 34035 1000/4000 A
C
100-125 V DC 54442
o
110-130 V AC 54443 34036
v
200-240 V AC External54444
power supply module (AD) / 1 part
e
380-415 V AC 54445
r

(
1

p
a
r
t
)
Test equipments / 1 Part
33592
Catalogue numbers EasyPact MVSand order form
Remote operation

Gear motor MCH (1 part) AC 50/60 Hz 100/130 V

47893 200/240 V

47894 380/415 V

47896 DC 24/30 V

47888 48/60 V
F
47889 100/125 V or
dr
a
47890 200/250 V w
-
47891 o
E95169 E95170 E95169 E95170E95169 E95172 ut
ci
rc
ui
t
br
e
a
k
er
47849
Fi
x
e
d.
D
ra
w
-
o
ut
.
In
Terminal block (1 part) For fixed circuit breaker st
47074 all
For draw-out circuit breaker at
47849 io
Fixed. Draw-out. n
Installation manual MVS21736 m
Closing release (XF) Standard coil (1 part) AC 50/60 Hz 24/30 V DC, 24 V AC a
n
u
al

St
a
n
33659 DC 48/60 V DC, 48 V AC
d
ar
33660 100/130 V AC/DC
d
c
MVS15511 200/250 V AC/DC
oi
l
MVS15512 380/480 V AC
(1
p
MVS15513 Terminal block (1 part) For fixed circuit breaker
ar
t)
47074

A
C
50/60 Hz 24/30 V DC, 24 V AC For draw-out ci
DC 48/60 V DC, 48 V AC 100/130 V AC/DC 200/250 V AC/DC 380/480 V AC 47849
In
Terminal block (1 part) For fixed circuit breaker
st
MVS21736 all
at
io
n
33659 33660 33661 33662 33664 47074
m
a
n
u
al
MVS21736

Fixed. Draw-out.
E95
170 24/30 V DC, 24 V AC
e MN
U
n
d
er
v
ol 33668 DC 48/60 V DC, 48 V AC
ta
g 33669 100/130 V AC/DC
e
re 33670 200/250 V AC/DC
le
a 33671 380/480 V AC
s
e 33673 Terminal block (1 part) For fixed circuit breaker
(1
p 47074
ar
t)
A
C
5
0/
6 R (non-adjustable) Rr
(adjust
0
able)
H AC
For draw-out circuit breaker 48/60 V
z 50/60 33680
AC/DC 47849
Hz
Fixed. Draw-out. n
100/130 V
I DC 33684 33681
AC/DC
n m
200/250 V
s a
t n
a u
l a MN delay unit (1 part)
l l
a
t MVS21736
i MN delay unit
o
Catalogue numbers EasyPact MVS
and order form

Chassis locking and accessories

1 lock with 1 key +


64934
adaptation kit
2 locks 1 key + adaptation
64935
kit
Profalux 1 lock+ 1 key
42888
(without adaptation kit)
Profalux 2 locks + 1 key
42878
1 lock with 1 key +
Ronis 64937
E46460 E46459E46458E46452DB117458
adaptation kit
2 locks 1 key + adaptation
64938
kit
Ronis 1 lock+ 1 key
41940
(without adaptation kit)
Ronis 2 locks + 1 key
41950
(without adaptation kit) Installation manual
Adaptation kit (without key Safety shutters + locking block / 1 part
800/4000 A 3P 4P

Inst
allation manual
Shutter locking
block (for
replacement) / 1
part
“Disconnected” position locking / 1
part By
padlocks 2 parts for
VCPO 800/4000 A

Installation manual
Standard

3P
By Profalux keylocks
Profalux Types for
N/H/NA/HA

By Ronis keylocks 47914

Door interlock / 1 part

MVS21737

Right and left-hand side of chassis (VPECD or VPECG) 64942


48596

MVS21737 487
Installation manual 48723

ield (CB) / 1 part 800/4000 A 3P 4P MVS21737 485

MVS21737 4P
Clusters

1 disconnecting contact cluster for chassis (see table below) (part 1) Racking handle

33166
Rack
ing
hand
le
47944
Table : number of clusters required for the different chassis models
E95561 E95538
Catalogue numbers EasyPact MVSand order
form

CDB
Circuit breaker locking and accessories
5000 ocks 48535 c
59
E95
Profalux h
536
Installation a
CDB
5000 manual r
58C
DB5
g
0006 i
1DB MVS21736
1256 n
17E
4673 By Ronis keylocks g
1 lock with 1 key +Escutcheon
5E4
Ronis 1 lock with 1 key + adaptation kit 64928
6666
adaptation kit and h
2 locks 1 keys + adaptation a
kit
accessories64929
/
64931 n
Profalux 1 lock+ 1 key1 part d
P 42888
(without adaptation kit) l
2 locks 1 keys + adaptation kit
u Profalux 2 locks + 1 key
42878 e
s
64932
h 47940
b
Ronis 1 lock+ 1 key (without adaptation kit)
ut I
to n
41940
n s
lo t
Ronis 2 locks + 1 key (without adaptation kit) a
ck Escutcheon l
in Cover l
41950
g Blanking a
d plate t
Adaptation kit (without key locks)
ev Installation i
ic manual o
64925 n
e/
Fixed Draw-out
MVS21736
1 I
Escutcheon 48601 48603 m
p n a
ar s
Transparent Front cover
cover (IP - (3P / 4P) / 48604 n
t t 1 u
54) part
a a
l MVS Front cover l
l MVS21808
a
t MVS21736
48536 i
o
n Arc chute for EasyPact MVS / 1 part
Installation manual

MVS21736 m
a
n
u
a Installation
l manual

MVS21736
MVS21736
Spring
Mechanical operation counter / 1 part charging
handle / 1
By part
Pr
of
al
ux 3P 4P
ke Operation counter CDM
MVS2 4 MVS2180
yl Type N/NA 3x
1807 x 7
MVS2 4 MVS2180
Type H/HA 3x
1807 x 7
Mechanical interlocking for source
CD
changeover
B5
000
urce changeover
(1)
60
CD
Interlocking of 2 devices using cables
Choose 2 adaptation sets (1 for each device + 1 set of cables)
B5
000
53
1 adaptation fixture for EasyPact MVS fixed devices
M 47926
e
c
1 adaptation fixture for EasyPact MVS draw-out devices
h
a 47926 1 set of 2 cables
n
i 33209
c (1) Can be used with any combination of EasyPact MVS, fixed or draw-out devices.

a
l
i
n
t
e
rl
o
c
k
i
Installation manual MVS21738
n Interlocking of 3 devices using cables Choose 3 adaptation (including 3 adaptation fixtures + cables) 3 sources, only 1 device closed, fixed or draw-out
g devices
f 48610
o
r 2 sources + 1 coupling, fixed or draw-out devices
s
o
48609

2 normal + 1 replacement source, fixed or draw-out devices

48608 Installation manual

MVS21738
Catalogue numbers EasyPact MVSand order form
Indication contacts

E4
666
1
E4
643 ON/OFF indication contacts (OF) / 12 parts
8E
466
89
ker

47074 For draw-out circuit breaker

47849

Installation manual MVS21736



R Installation manual MVS21736
e “Connected, disconnected, test position” indication contact (carriage switches) / 1 part
a
d
y
t Changeover contacts 6 A - 240 V
o 33170
cl Installation manual
o MVS21736
s Auxiliary terminals for chassis alone
e

c
o
n
t
a
c
t
(
1
3 wire terminal (1 part) 47849
m 6 wire terminal (1 part) 47850
a Jumpers (10 parts) 47900
x.
)
/
1
p
a
rt

1
c
h
a
n
g
e
o
v
er
c
o
nt
a
ct
(5
A
-
2
4
0
V)
4
7
0
8
0
W
iri
n
g
F
or
fix
e
d
ci
rc
ui
t
br
e
a
I uctions
n
s
t EasyPact MVS User Manual (English)
MVS2173
4
MVS2173
r Fixed & draw-out circuit breaker
5
MVS2173
Circuit breaker accessories
6
MVS2173
Chassis accessories
Catalogue numbers and order form EasyPact MVS
Order ref no: Date: Product and Switch-disconnectors Customer Order form
ref no:

OA No. Indication contacts OF - ON/OFF indication contacts Standard 1 block of 4 OF 10 A-240/380V AC Additional 1 block of 4 OF 6 A-240/380V AC
(to be filled by Order booking team) √

To indicate your choices, check the


applicable square boxes

And enter the appropriate information in


the rectangles

EasyPact SDE - “fault-trip” indication contact Standard 1 SDE 5A -240/380V AC

MVS
Rating A
Circuit
Circuit
breaker
breaker
N/
H
Type of equipment N Draw out with chassis Draw out without chassis
Fixed
Switch
A/
Disconn (moving part only)
H
ector
A

Key lock kit (w/o key lock)


R
VSPO -Device locking in
Profal o
OFF position by key lock
ux ni
(Only one key lock per ACB
s
possible)
Carriage switches
R 8 A-240/380V AC
Profal o
1 key lock

Trip System functions: 2I : Basic protection (long time + inst.) 5S : Selective protection (long time + short time + inst.) 6G : Selective + earth-fault protection
(long time + short time + inst. + earth-fault)
CDP - Escutcheon Standard

Notes:
Customer can provide only the reference no. of the product for the listed references. Kindly refer to product catalogue for list of references. Customer to fill this order form
for non-listed references. All breakers will be provided with 1 OF (4 c/o contacts), 1 SDE (trip contact), Escutcheon (Panel sealing frame) as standard. All draw-out
breakers/switches will be supplied with Chassis & safety shutter. For Electrical operated breakers/ switches, indicate the voltage ratings of MCH,XF & MX Refer to product
catalogue for available voltage ratings of MCH/XF/MX/MN & AD Module The orientation of customer connecting terminals can be changed at site from Horizontal to
vertical or vice-versa.

Safety Shutter locking blocks

CP - Transparent cover for escutcheon

OP - Blanking plate for escutcheon

CDM - Mechanical operation counter for MVS

CB - Auxiliary terminal shield fitted on chassis

EIP - Interphase barriers

HHTK - Hand held test kit


© Electric - All rights reserved.
20 Schneider Electric Industries SAS As standards, specifications and designs change from time to time, please ask for confirmation 35, rue Joseph Monier
14 of the information given in this publication. CS 30323
-
Sc This document has been printed on ecological paper
hn F- 92506 Rueil Malmaison Cedex
ei
de RCS Nanterre 954 503 439 Design: Schneider Electric Capital social 896 313 776 € Photos:
r Schneider Electric www.schneider-electric.com Printed:

LVED211021EN 08-2018
䔀氀攀挀琀爀椀挀洀漀琀漀爀䴀䌀䠀昀漀爀䔀愀猀礀倀愀挀琀䴀嘀匀⸀