Вы находитесь на странице: 1из 44

Control and Monitoring System

MSSR-1 Radar

China MSSR 2019


Basic Elements in Menu
Indicators (color)
Status Indicators

Indicators of LED Type

Buttons and Switches

Button –

Switch (ToggleButton) – buttons with fixation

Boxes

EntryBox (text or digital value)

SpinButton (digital value) with arrows control

2
Basic Elements in Menu (cont.)
Label (colored)
status etc.

CheckButton
ON / OFF state

RadioButton
selection

ProgressBar
filling

Scale Indicator

ComboBox
selection from pull-down menu

3
Basic Groups of elements
Flaps (switching between pages)

Channel switch

Device block
(Main & System Page)
Detail –navigation shortcut to a device on CMS
Status – particular device status list
Block status – currently known device status

Equipment Status ( + Global Status) strips


in page footer

4
Items in Page Header
Master CMS Selection

Page Title

Time Block
Containing fields:
1. GPS time system version:
 Last Time – externally received
 Actual Time – internal computer time
2. NTP server time system version:
 System Time – computer time controlled by NTP
daemon

5
Main Page
Main
switchboard

AutoBackup Toggle

Rotation control

MSSR-I part
SCS Radar
Control

SSR channels
Global Statuses

Alarm sound mute

Login frame

6
MSSR-I Part of Main screen

MSSR ISSR
MSSR channel Equipment Block
RF Power Switch

MultiSwitch for AILan & AIOptD Block


Transmitter / Receiver Transmitter, Roation Cintrol, Angle Info
channel selection Receiver Equip.
Power supply
diagnostics

7
Main Page (other details)
Switchboard Frame:
(Contactors control buttons)
PowerSupply Diagnostic
Main Switchboard State Indication
MSSR Electronics Supply Switch

AutoBackup Frame (Device


autobackup availability)
Test targets number indication
(“detected”/”expected”) + LED status
AutoBackup ToggleButton
Stat – to open Target Status Window

Rotation Control
Inverter/Rotation Control
From both Inverter
From single inverters
MultiSwitch diagnostic

8
Other parts of Main screen
Data Flow Arrows :
Colors depends on current block diagnostics
Light green for Master/Active channel
Dark green for Slave/Backup channel

Alarm sound mute


Login Frame
For getting access to critical items

9
RSRB Receiver Page

ISSR Signal of Channel


Diag Info
Trigger & Data

Receiver Parameters

MSYN converters Mode

Calibration Control
Block

Voltage Diag

10
RSRB Receiver Page – Calibration frame
Calibration:
Control of calibration

Calibration Verification:
Exist – current characteristics
New – new characteristics

Parameters:
Sensitivity of receivers
Calibration deviation from ideal
characteristic
Phase diagnostic between
HighGain and LowGain channels

11
MSSR Transmitter page

Transmitter

Output Amplifier :
Diagnostic information :
Temperature, Power, VSWR

Oscillator indication

MSSR RF Power Switch

Transmitter Input Signals


diagnostic

Power Level Measurement


Button

12
Power Level Measurement Window

Power Level
Measurement Window

13
MSSR Transmit Generator

Mode Enable

Interrogation Scheduler

Pattern List Buttons

ModeS Link management

Transmit Levels

14
MSSR Transmit Generator - statistics
Interrogation statistics
 Summary
RPM, Target number, RollCall interrogation

 Periods
Mode periods

 II codes

 SI codes

 UF/DF Reply
Replies for Uplink / Downlink Format

 UF11 PR

 Lock / NoLock
number of Locked / NoLocked replies

15
MSSR Transmitter Generator – Pattern Mode List

Pattern Mode List


 Information about all
patterns

Pattern Mode Edit


 Creation/Editation patterns

16
MSSR Transmitter Generator
- Pattern Mode Abbreviations
List of used Pattern Mode Abbreviations
M1 – mode 1 (military)
M2 – mode 2 (military)
M3A – mode 3A (provides a 4-digit octal identification code)
MC – mode C (provides the aircraft's pressure altitude)
UF11 – mode All-call (provides 24bit technical mode-S address)
ROLL – mode Roll-call (provides selective interrogation using mode-S address)
M3AS – mode 3/S (Mode-S transponders provide mode-S address, SIF transponders provide M3A)
MCS – mode C/S (Mode-S transponders provide mode-S address, SIF transponders provide MC)
M3o – mode 3A only (Mode-S transponders no reply, IFF transponders provides M3A)
MCo – mode C only (Mode-S transponders no reply, IFF transponders provides MC)
CM3o – combine mode UF11 and M3o, two interrogations in one period.
CMCo – combine mode UF11 and MCo, two interrogations in one period.

17
MSSR Transmitter generator – pattern probability

Pattern Probability List


Information about all patterns probability

Pattern Probability Edit


 Creation/Editation pattern probability

18
Transmitter generator – pattern probability
- abbreviations
Pattern Probability – list of used abbreviations :

OvN1 is probability 1 for non LockOut transponders


OvN2 is probability 1/2 for non LockOut transponders
OvN4 is probability 1/4 for non LockOut transponders
OvN8 is probability 1/8 for non LockOut transponders
OvN16 is probability 1/16 for non LockOut transponders

OvY1 is probability 1 for all transponders (independently if are LockOut or not)


OvY2 is probability 1/2 for all transponders (independently if are LockOut or not)
OvY4 is probability 1/4 for all transponders (independently if are LockOut or not)
OvY8 is probability 1/8 for all transponders (independently if are LockOut or not)
OvY16 is probability 1/16 for all transponders (independently if are LockOut or not)

19
MSSR Interrogator (ISSR)

Angle Info Diagnostic


Diagnostics AI – ACP , ARP
Master Channel Selection

Opto Diagnostic
Master Channel Selection

Monopulse Consistency
Check (in last X ant. scans)
Target Accuracy Calculation :
 Overall targets (in defined map)
 for Site Monitor1,2

20
AILAN Page – Angle Information processing

Angle Information
Actual value of AI
Rectification Info
Deviation

Rotation Control
Rotation Speed control
Angle Info Diagnostic
ACP, ARP

HF Relay Diagnostic
This and opposite
channel

21
AILAN Page - Angle Information Frame (cont.)
Angle Information Frame
Current AI value (color status)
Rectification (available with max. user
rights only !) Antenna Rotation Speed
Auto - for Automatic setting of opposite Requested/measured data
encoder rectification Speed [rot/min]
Measured Deviation (sensors data Revolution Time [s]
comparison) – Min, Max

Rotation Switch

ACP / ARP Diagnostics


ACP, ARP data presence
indication

HF Relay status
the status of antenna relay switches (from
this and opposite channel)

22
AIOptD Page
Rotation Control, Angle Information processing

AIOPTD device status


Temperatures Int., Ext.

Antenna status

Gear Box Vibration status

Rotation Control

Inverter status.

Oil Level, Gear Box

23
AIOptD Page – Status, Oil, Wind
Status signals :
ADC: Information Indicator outputs status of ADC for
vibration measurement.
Angle Sensor – connected, Rotation speed in range
Antenna rotation: Green(Ok), Orange (Rotation
speed is different from ETALON measurement
speed), Red – speed out of range
Vibration: Indicator outputs warning for vibration
over limit
Operation: Indicator outputs status of all internal
processes running properly
Internal / External Temperature [C]

Oil Level progressbar


Gear box status

Wind frame – Wind speed measurement


(optional)

24
AIOptD Page – Antenna status & Rotation Control

Antenna status frame


Antenna Smoke Sensor
Rotation Block
Total Stop
Contactor power
Inverter Power
Ant. Shelter Temperature
Antenna Door Contact

Rotation Control and Diagnostic


Rotation speed
Rotation start / stop
Inverter parameters
Inverter status
Inverter hours

25
AIOptD Page – Vibration Measurement

Vibration Status
D detection etalon – SENSOR 1, 2: indicates for deviation
of number of measured peaks in CEPSTRUM from
measured number of peaks in ETALON measurement.
Output number closer to 0 is better.
Gravity of Measured deviation and etalon – SENSOR 1, 2:
indicates for GRIVITY deviation in amplitudes from
ETALON measurements. Output number closer to 0 is
better.
Sensitivity - value of vibration warning detection. Default 1
Measure Managements
Manual Backup: manual backup all ETALON
measurements
Load Backup into AIOPTD - Manual load ETALON
measurements
Wipe and Measure new Etalon - Measure new ETALON
Show Graph - New window with empty graph - data import
Calibration Measurement - Only one time operation before
ETALON measurements can be completed

26
AIOptD Page – Vibration Measurement

Vibration Measurements Results

Special window with Measurements


Results

27
Radar Control Page (SCS block)

SCS Block :
Auxiliary Radar Signal Control
and Monitoring

Radar Switchboard and


auxiliary signal monitoring
Configurable internal and external
Signals, depend on cabling

28
SCS - Radar Control Frame
Basic Radar Switchboard
Control
Auxiliary Radar Signal Control and
Monitoring
MSSR electronics Power Supply

Measured values:
Temperatures (Room temperature
available in one channel only)
Phase Voltages

Custom signal control and


monitoring available
SSR Electronic Power Supply with
signalization
(configurable for other external
signals)

System Warning Window with sound


alarm possibility

29
Setting Page
Save and Reload of
Equipment Settings
Quick Restore of full Equipment
setting
Usually Setting 7 is used for
Factory Setting (should be
blocked against rewriting)
Settings are saved on local
computer Hard disk

About Program:
CMS Menu Version
Contacts To Provider

30
Setting Page (cont.)
Settings table :
 Setting number  Date & Time of data
Label enabled – saved settings available
 Load button
Loads selected saved settings
 Save button
Usually confirmation required
Saves current settings to selected settings row
 Remove button “-”
Usually confirmation required
Removes unused saved settings
 Settings Name
 Evaluate button
User defined string as saved settings
identification/name Saves current settings content as file to local hard
disk in text form

31
Setting Page (equipment table)
Equipment table :
 Select All Equipment
Shortcut for all equipment selection

 Channel A / B
Selection for all equipment, channel A/B

 Apply Save on All CMS’s


Selective settings save

Detail Equipment table :


(after Equipment Details selection)
 Checkbuttons for particular equipment
Selection of discrete equipment to be saved / loaded
Selected equipment are (re)written on HD, others
NOT AFFECTED !!

32
Status / Command Page
Status :
 Actual
 History

Listing Mode Selection :


 Statuses – from equipment
 Commands – to equipment
 Warning – Warning messages
from equipment
 Watch – text analyze of datagram
content from equipment
 Actual – datagram content
analyze in selected interval

Items (columns) :
 Time
 Source (if Commands)
 Equipment ID
 Text of Status / Commands

Equipment Filter :
(Right part of screen)
Equipment required for Status
evaluation
Interval Selection :
(for Status History only)
Press F2 for today’s interval

33
Status / Command Page - (cont.)
Equipment Filter
 Channel A/B checkbuttons
 Equipment checkbuttons
 Refresh Button
 Report Filter (optional)

Interval Selection
For Status History Mode
 Press F2 for today’s interval
(5:00 to actual)

Printer (Save) Functions


(optional)

34
Status / Command Page - Used colors

Status colors :
 green – OK statuses, etc.
 orange – warning statuses
 red – error statuses
 dark red – offline statuses
 white – purposely off statuses
Command colors :
 deep sky blue – commands from this xCMS
 dark blue – commands from another xCMS
Watch colors :
 sky blue
Actual state colors:
 purple

35
Equipment Status / Command Window
Items :
 Time
 Text = status content

36
System Page
Additional System Equipment :
 Output Master Select (manual)
 xCMS computers Status
 SSR data flow (Master)
 DVAZ diagnostic
 SSR Scan diagnostic (opt.)
 APOID diagnostic (optional)

37
System Page (cont.)
CMS computers :
 Conn.
Left – connection to CMS
Right – connection to system
Master
 Master
 MasterSys
Control of system master function

DVAZ diagnostic :
 Conn.
 Recording Mode :
Record
Replay
 Disk Saved

38
System Page (data flow)

System data flow :


In upper part always Master channel !!
 SSR Master Channel
Data analyzes status
Target statistics
 MSSR Sw
Data connection to Master / Slave
switch button Change for manual SSR
Master switch

39
System Page (other equipment)

SSR Scan (optional) :


 Video signals diagnostic :
ACP
ARP
Sync
Video’s
 Status

40
Power Supply diagnostics
Power supply information

HW ZDIAG board
(Voltage only)
 Switchboard
 RSRB
 TMOS

PC diagnostic - IPMI
 ISSR

(IPMI = Inteligent Platform


Management System)

41
Warning Window
Purpose of Warning Window
(Only one common window - for whole system (rewritten by new warning)

 SYSTEM warning
some warning should be completed by Sound Alarm (configurable)
 Action Confirmation from User
for “dangerous” actions

42
Warning Window (Multi)
Purpose of Multi Warning Window (equipment)
One window for one equipment
 SYSTEM warning (for one equipment)
 Possibility to disable this type of warning for selected interval (set by spinbutton)
 If right mouse button click to “Cancel” button, all Multi Warning window will be
closed at once

43
User Help Window
Help Window
Appears after right click on status row in Equipment block.
It contains some useful hints for troubleshooting and
problem solving.

44