MSSR-1 Radar
Button –
Boxes
2
Basic Elements in Menu (cont.)
Label (colored)
status etc.
CheckButton
ON / OFF state
RadioButton
selection
ProgressBar
filling
Scale Indicator
ComboBox
selection from pull-down menu
3
Basic Groups of elements
Flaps (switching between pages)
Channel switch
Device block
(Main & System Page)
Detail –navigation shortcut to a device on CMS
Status – particular device status list
Block status – currently known device status
4
Items in Page Header
Master CMS Selection
Page Title
Time Block
Containing fields:
1. GPS time system version:
Last Time – externally received
Actual Time – internal computer time
2. NTP server time system version:
System Time – computer time controlled by NTP
daemon
5
Main Page
Main
switchboard
AutoBackup Toggle
Rotation control
MSSR-I part
SCS Radar
Control
SSR channels
Global Statuses
Login frame
6
MSSR-I Part of Main screen
MSSR ISSR
MSSR channel Equipment Block
RF Power Switch
7
Main Page (other details)
Switchboard Frame:
(Contactors control buttons)
PowerSupply Diagnostic
Main Switchboard State Indication
MSSR Electronics Supply Switch
Rotation Control
Inverter/Rotation Control
From both Inverter
From single inverters
MultiSwitch diagnostic
8
Other parts of Main screen
Data Flow Arrows :
Colors depends on current block diagnostics
Light green for Master/Active channel
Dark green for Slave/Backup channel
9
RSRB Receiver Page
Receiver Parameters
Calibration Control
Block
Voltage Diag
10
RSRB Receiver Page – Calibration frame
Calibration:
Control of calibration
Calibration Verification:
Exist – current characteristics
New – new characteristics
Parameters:
Sensitivity of receivers
Calibration deviation from ideal
characteristic
Phase diagnostic between
HighGain and LowGain channels
11
MSSR Transmitter page
Transmitter
Output Amplifier :
Diagnostic information :
Temperature, Power, VSWR
Oscillator indication
12
Power Level Measurement Window
Power Level
Measurement Window
13
MSSR Transmit Generator
Mode Enable
Interrogation Scheduler
Transmit Levels
14
MSSR Transmit Generator - statistics
Interrogation statistics
Summary
RPM, Target number, RollCall interrogation
Periods
Mode periods
II codes
SI codes
UF/DF Reply
Replies for Uplink / Downlink Format
UF11 PR
Lock / NoLock
number of Locked / NoLocked replies
15
MSSR Transmitter Generator – Pattern Mode List
16
MSSR Transmitter Generator
- Pattern Mode Abbreviations
List of used Pattern Mode Abbreviations
M1 – mode 1 (military)
M2 – mode 2 (military)
M3A – mode 3A (provides a 4-digit octal identification code)
MC – mode C (provides the aircraft's pressure altitude)
UF11 – mode All-call (provides 24bit technical mode-S address)
ROLL – mode Roll-call (provides selective interrogation using mode-S address)
M3AS – mode 3/S (Mode-S transponders provide mode-S address, SIF transponders provide M3A)
MCS – mode C/S (Mode-S transponders provide mode-S address, SIF transponders provide MC)
M3o – mode 3A only (Mode-S transponders no reply, IFF transponders provides M3A)
MCo – mode C only (Mode-S transponders no reply, IFF transponders provides MC)
CM3o – combine mode UF11 and M3o, two interrogations in one period.
CMCo – combine mode UF11 and MCo, two interrogations in one period.
17
MSSR Transmitter generator – pattern probability
18
Transmitter generator – pattern probability
- abbreviations
Pattern Probability – list of used abbreviations :
19
MSSR Interrogator (ISSR)
Opto Diagnostic
Master Channel Selection
Monopulse Consistency
Check (in last X ant. scans)
Target Accuracy Calculation :
Overall targets (in defined map)
for Site Monitor1,2
20
AILAN Page – Angle Information processing
Angle Information
Actual value of AI
Rectification Info
Deviation
Rotation Control
Rotation Speed control
Angle Info Diagnostic
ACP, ARP
HF Relay Diagnostic
This and opposite
channel
21
AILAN Page - Angle Information Frame (cont.)
Angle Information Frame
Current AI value (color status)
Rectification (available with max. user
rights only !) Antenna Rotation Speed
Auto - for Automatic setting of opposite Requested/measured data
encoder rectification Speed [rot/min]
Measured Deviation (sensors data Revolution Time [s]
comparison) – Min, Max
Rotation Switch
HF Relay status
the status of antenna relay switches (from
this and opposite channel)
22
AIOptD Page
Rotation Control, Angle Information processing
Antenna status
Rotation Control
Inverter status.
23
AIOptD Page – Status, Oil, Wind
Status signals :
ADC: Information Indicator outputs status of ADC for
vibration measurement.
Angle Sensor – connected, Rotation speed in range
Antenna rotation: Green(Ok), Orange (Rotation
speed is different from ETALON measurement
speed), Red – speed out of range
Vibration: Indicator outputs warning for vibration
over limit
Operation: Indicator outputs status of all internal
processes running properly
Internal / External Temperature [C]
24
AIOptD Page – Antenna status & Rotation Control
25
AIOptD Page – Vibration Measurement
Vibration Status
D detection etalon – SENSOR 1, 2: indicates for deviation
of number of measured peaks in CEPSTRUM from
measured number of peaks in ETALON measurement.
Output number closer to 0 is better.
Gravity of Measured deviation and etalon – SENSOR 1, 2:
indicates for GRIVITY deviation in amplitudes from
ETALON measurements. Output number closer to 0 is
better.
Sensitivity - value of vibration warning detection. Default 1
Measure Managements
Manual Backup: manual backup all ETALON
measurements
Load Backup into AIOPTD - Manual load ETALON
measurements
Wipe and Measure new Etalon - Measure new ETALON
Show Graph - New window with empty graph - data import
Calibration Measurement - Only one time operation before
ETALON measurements can be completed
26
AIOptD Page – Vibration Measurement
27
Radar Control Page (SCS block)
SCS Block :
Auxiliary Radar Signal Control
and Monitoring
28
SCS - Radar Control Frame
Basic Radar Switchboard
Control
Auxiliary Radar Signal Control and
Monitoring
MSSR electronics Power Supply
Measured values:
Temperatures (Room temperature
available in one channel only)
Phase Voltages
29
Setting Page
Save and Reload of
Equipment Settings
Quick Restore of full Equipment
setting
Usually Setting 7 is used for
Factory Setting (should be
blocked against rewriting)
Settings are saved on local
computer Hard disk
About Program:
CMS Menu Version
Contacts To Provider
30
Setting Page (cont.)
Settings table :
Setting number Date & Time of data
Label enabled – saved settings available
Load button
Loads selected saved settings
Save button
Usually confirmation required
Saves current settings to selected settings row
Remove button “-”
Usually confirmation required
Removes unused saved settings
Settings Name
Evaluate button
User defined string as saved settings
identification/name Saves current settings content as file to local hard
disk in text form
31
Setting Page (equipment table)
Equipment table :
Select All Equipment
Shortcut for all equipment selection
Channel A / B
Selection for all equipment, channel A/B
32
Status / Command Page
Status :
Actual
History
Items (columns) :
Time
Source (if Commands)
Equipment ID
Text of Status / Commands
Equipment Filter :
(Right part of screen)
Equipment required for Status
evaluation
Interval Selection :
(for Status History only)
Press F2 for today’s interval
33
Status / Command Page - (cont.)
Equipment Filter
Channel A/B checkbuttons
Equipment checkbuttons
Refresh Button
Report Filter (optional)
Interval Selection
For Status History Mode
Press F2 for today’s interval
(5:00 to actual)
34
Status / Command Page - Used colors
Status colors :
green – OK statuses, etc.
orange – warning statuses
red – error statuses
dark red – offline statuses
white – purposely off statuses
Command colors :
deep sky blue – commands from this xCMS
dark blue – commands from another xCMS
Watch colors :
sky blue
Actual state colors:
purple
35
Equipment Status / Command Window
Items :
Time
Text = status content
36
System Page
Additional System Equipment :
Output Master Select (manual)
xCMS computers Status
SSR data flow (Master)
DVAZ diagnostic
SSR Scan diagnostic (opt.)
APOID diagnostic (optional)
37
System Page (cont.)
CMS computers :
Conn.
Left – connection to CMS
Right – connection to system
Master
Master
MasterSys
Control of system master function
DVAZ diagnostic :
Conn.
Recording Mode :
Record
Replay
Disk Saved
38
System Page (data flow)
39
System Page (other equipment)
40
Power Supply diagnostics
Power supply information
HW ZDIAG board
(Voltage only)
Switchboard
RSRB
TMOS
PC diagnostic - IPMI
ISSR
41
Warning Window
Purpose of Warning Window
(Only one common window - for whole system (rewritten by new warning)
SYSTEM warning
some warning should be completed by Sound Alarm (configurable)
Action Confirmation from User
for “dangerous” actions
42
Warning Window (Multi)
Purpose of Multi Warning Window (equipment)
One window for one equipment
SYSTEM warning (for one equipment)
Possibility to disable this type of warning for selected interval (set by spinbutton)
If right mouse button click to “Cancel” button, all Multi Warning window will be
closed at once
43
User Help Window
Help Window
Appears after right click on status row in Equipment block.
It contains some useful hints for troubleshooting and
problem solving.
44