Вы находитесь на странице: 1из 72

Installation and Operating Manual

Turbo Couplings
with Constant Fill

3626-011000 en

ATTENTION!
Please be sure to read this manual prior to installation and commis-
sioning and keep it for further use!

1)
Serial No.

Coupling type

Year of manufacture

Mass (weight) kg

Power transmission kW

Input speed rpm


3
Filling (mineral oil) dm (litre)

Response temperature of °C
fusible plugs

Type of connecting coupling

Sound pressure level dB(A)

Position G horizontal
G vertical
Drive via G outer wheel
G inner wheel

1)
Please quote the serial number in all correspondence (à section 15).

Voith. Betriebsanleitung
Turbo Couplings with
Constant Fill

Contents
1 Manufacturer’s Declaration as defined by EU Directive
89/392/EWG, Annex II B for Machines not ready for use....................4

2 Preface ....................................................................................................5
2.1 General information .......................................................................5
2.2 Proper use .....................................................................................6

3 Safety.......................................................................................................7
3.1 Notes and symbols ........................................................................7
3.2 General information as to dangerous situations ............................8
3.3 Important information as to operation ............................................9
3.4 Staff qualification..........................................................................10
3.5 Product observation .....................................................................10

4 Function, Types....................................................................................11
4.1 Function .......................................................................................11
4.2 Type designation..........................................................................12
4.3 Design examples .........................................................................14
4.3.1 Connecting coupling on the output side .........................14
4.3.2 Connecting coupling on the input side............................15

5 Tightening Torques .............................................................................16


5.1 Fixing bolts...................................................................................16
5.2 Fusible plugs, filler plugs, blind screws and sight glasses ..........17
5.3 Fastening and nozzle screws.......................................................17

6 Installation of Basic Coupling Type T................................................18


6.1 As delivered condition..................................................................18
6.2 Preparation ..................................................................................18
6.3 Mounting ......................................................................................20
6.4 Mounting devices .........................................................................22

7 Installation of Basic Coupling Type TN ............................................23


7.1 As delivered condition..................................................................23
7.2 How to mount the coupling...........................................................24

8 Alignment..............................................................................................25
8.1 Flexible connecting couplings ......................................................25
8.1.1 Connecting coupling on the input side............................25
8.1.2 Connecting coupling on the output side .........................26
8.2 Laid lengths and type allocations turbo coupling / flexible
connecting coupling .....................................................................27
8.3 Alignment tolerances ...................................................................27
8.4 Alignment .....................................................................................28

9 Operating Fluids...................................................................................30
9.1 Requirements to be fulfilled by the operating fluid .......................30
9.2 Proposed operating fluids ............................................................31
9.3 Proposed operating fluids for special requirements.....................32
Installation and Operating Manual 3626-011000 en.

10 Fill, Filling Check and Draining...........................................................33


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

10.1 Coupling fill ..................................................................................34


10.1.1 How to fill couplings installed in horizontal position ........34
Turbo Couplings with Constant Fill.

10.1.2 How to fill couplings installed in vertical position ............35


Subject to modification due to

10.2 Level check ..................................................................................35


technical development.

10.2.1 Level check


for couplings installed in horizontal position ...................35
10.2.2 Level check
for couplings installed in vertical position .......................36

2 Voith. Operating Manual


Turbo Couplings with
Constant Fill

10.3 Draining the coupling ...................................................................36


10.3.1 How to drain couplings without delay chamber
installed in horizontal position.........................................37
10.3.2 How to drain couplings with delay chamber
installed in horizontal position.........................................37
10.3.3 How to drain couplings installed in vertical position........37

11 Commissioning ....................................................................................38

12 Maintenance .........................................................................................39
12.1 Operating fluid..............................................................................39
12.2 Flexible connecting coupling........................................................39
12.3 Fusible plugs................................................................................40
12.4 Outside cleaning ..........................................................................40
12.5 Bearing lubrication .......................................................................41

13 Coupling Disassembly.........................................................................42
13.1 Preparation ..................................................................................42
13.2 Removal.......................................................................................43
13.3 Mechanical removal devices........................................................44
13.4 Hydraulic removal devices ...........................................................45

14 Trouble Shooting .................................................................................46

15 Queries, Orders placed for Service Engineers and Spare Parts .....48

16 Monitoring Devices..............................................................................49
16.1 MTS mechanical thermal switch unit ...........................................49
16.2 BTS non-contacting thermal switch unit ......................................49

17 Spare Parts Information Turbo Coupling ..........................................50


17.1 Spare parts for type 154 T ...........................................................51
17.2 Spare parts for type 206/274 T ....................................................51
17.3 Spare parts for types T and TN from size 366...........................52
17.3.1 Spare parts for types
366/422/487/562/650/750/866/1000/1150 T ..................53
17.3.2 Spare parts for types 366/422/487/562/650 TN .............53
17.4 Spare parts for types 274 TV/TVV ...............................................54
17.5 Spare parts for types TV/TVV and TVN/TVVN from size 366 ...56
17.5.1 Types 366/422/487/
562/650/750/866/1000/1150TV/TVV ..............................57
17.5.2 Types 366/422/487/562/650 TVN/TVVN ........................57
17.6 Spare parts for types TVVS and TVVSN ....................................58
17.6.1 Spare parts for types 422/487/562/650/750/866 TVVS..59
17.6.2 Spare parts for types 422/487/562/650 TVVSN .............59
17.7 Spare parts for type 154 DT.........................................................60
17.8 Spare parts for types 206 DT and 274 DT/DTV...........................61
17.9 Spare parts for types 1150 DT/DTV ............................................62

18 Spare parts information Connecting couplings................................64


18.1 Connecting coupling on the input side .........................................64
18.1.1 Flexible cam coupling type ENK ....................................64
Installation and Operating Manual 3626-011000 en.

18.1.2 Flexible element coupling type EEK ..............................64


18.1.3 Flexible packet coupling type EPK ................................65
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

18.2 Connecting coupling on the output side.......................................65


18.2.1 Normex-coupling type G.................................................65
Turbo Couplings with Constant Fill.

Subject to modification due to

19 Representatives Voith Turbo GmbH & Co. KG .................................68


technical development.

20 Index .....................................................................................................71

Voith. Operating Manual 3


Turbo Couplings with
Constant Fill

Voith Turbo GmbH & Co. KG


Startup Components
P.O. Box 1555
74555 Crailsheim
GERMANY
Phone: (07951) 32-0
Fax: (07951) 32-480
E-mail:
startup.components@voith.com
www:
www.startup-components.com

1 Manufacturer’s Declaration as
defined by EU Directive
89/392/EWG, Annex II B for
Machines not ready for use

We herewith declare that the

machine denominated: Turbo Coupling with constant fill

Machine type: See cover sheet

Machine No. (Serial No.): See cover sheet

is intended for installation in a machine or to be assembled with a machine


and commissioning is not allowed until it has been determined after
installation/assembly that the complete machine complies with the currently
applicable edition of the EU Directive.

Relevant EU Directives: EU Directive 89/392/EWG in its currently


applicable version.

Harmonized standards applied, particularly


DIN EN 292 T1/2, DIN EN 349

Each modification of the parts supplied, required by the customer,


invalidates the declaration.

Date/manufacturer’s signature: 2002-08-01 /


Installation and Operating Manual 3626-011000 en.

Particulars with regard to the Undersigned: Dr.-Ing. R. Finzel


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

Product Group Manager


Startup Components
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

4 Voith. Operating Manual


Turbo Couplings with
Constant Fill

2 Preface

2.1 General information

This manual will support you in using this turbo coupling in a safe, proper
and economical way. If you observe the information contained in this
manual, you will
– increase the reliability and lifetime of coupling and installation,
– avoid any risks,
– reduce repairs and downtimes.

This manual must


– always be available at the machine site,
– be read and used by every person who works on the coupling.

The coupling is manufactured to the latest design standards and approved


safety regulations. Nevertheless, the user’s or third parties life may be
endangered or the machine or other material assets impaired in case of
improper handling or use.

Spare parts must comply with the requirements determined by Voith. This is
guaranteed in case of original spare parts, as these are subject to regular
quality control according to DIN ISO 9001 / EN 29001.

Spare parts from other suppliers may, under circumstances, change the
characteristics of the unit and lead to substantial defects, for which Voith
cannot assume responsibility.

For repair, only use appropriate workshop equipment. Professional


maintenance or repair can only be guaranteed by the manufacturer.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 5


Turbo Couplings with
Constant Fill

This manual has been issued with utmost care. However, in case you should
need any further information, please contact:

Voith Turbo GmbH & Co. KG


Startup Components
P.O. Box 1555
74555 Crailsheim
GERMANY
Phone: (07951) 32-0
Fax: (07951) 32-480
E-mail: startup.components@voith.com
WWW: www.startup-components.com

© 2002.
This manual is protected by copyright.
Voith Turbo reserves the right for modifications.

2.2 Proper use

– The constant fill coupling is provided to transmit the torque from the drive
motor to the driven machine.
– The power the coupling is allowed to transmit during steady operation at
a specific input speed and a specific coupling fill (operating fluid and
filling) is entered on the cover sheet of this manual. Use for another
purpose, e.g. for higher powers, higher speeds, other operating fluids or
for operating conditions not agreed, is not being considered as proper
use.
– Proper use also includes observing this installation and operating manual
and complying with the inspection and maintenance instructions.
– The manufacturer is not liable for damages resulting from improper use.
The risk is to be borne solely by the user.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

6 Voith. Operating Manual


Turbo Couplings with
Constant Fill

3 Safety

3.1 Notes and symbols


We classify hazards in various stages. The table below gives you a survey
on the allocation of symbols, hazard classes and signal words relating to the
hazard and (possible) consequences.

Damage / Signal word Definition Consequences Symbol


harm to...

Persons DANGER! imminent fatal or most


danger serious injuries
(crippling)

Persons WARNING! dangerous fatal or most


situation serious injuries
possible possible

Persons CAUTION! less slight or minor


dangerous injuries possible
situation

Property ATTENTION! harmful damage possible to


situation – the product
possible
– its environment

– Note! application efficient in


Information! hints and operation
other useful
information
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 7


Turbo Couplings with
Constant Fill

3.2 General information as to dangerous situations


For all work performed on the turbo coupling, please observe the local
regulations for prevention of accidents!

DANGER!

– Working on the turbo coupling:


For all work carried out on the turbo coupling ensure that both,
drive motor and driven machine have stopped running and startup
is absolutely impossible!
Start your work only after the coupling has cooled down below
40°C, otherwise there is a risk of burns!

– Temperature rise in the turbo coupling:


The coupling temperature rises during operation.
Please provide a guard for protection against contact with the
coupling! However, ventilation of coupling must not be impaired.
Never use fluids to cool down the coupling!

– Rotating parts:
Rotating parts, for example, the turbo coupling itself and exposed
shaft parts need to be protected against contact by a guard!
However, ventilation of coupling must not be impaired.
Never operate the coupling without these guards!

– Sprayed-off operating fluid:


In the event of thermal overload of the turbo coupling, the fusible
plugs respond. Operating fluid is discharged through these fusible
plugs.
Please ensure that the sprayed off operating fluid cannot get in
contact with persons! Danger of burning!
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

8 Voith. Operating Manual


Turbo Couplings with
Constant Fill

3.3 Important information as to operation

ATTENTION!

– Power transmission:
The cover sheet of this operating manual shows the possible power
to be transmitted at a specific input speed and a specific coupling
fill (operating fluid and fill). These values describe a permissible
working point for steady operation of coupling.
Voith Turbo’s approval is required for steady operation of coupling
at a different working point!

– Operating fluid:
Use only the operating fluid mentioned on the cover sheet of this
operating manual! Operate the turbo coupling only with the
operating fluid fill shown on the cover sheet of this operating
manual.
A too low fill would cause thermal overload of coupling and, in case
of an overfill, the internal pressure could damage the coupling.

– Temperature rise during startup:


During startup, the temperature in the turbo coupling rises more
than during steady operation due to a higher slip. Observe that the
intervals between starts are sufficient to avoid thermal overload!

– Starting characteristic of turbo couplings with delay chamber:


During startup, the operating fluid is delivered from the delay
chamber into the turbo coupling working chamber. On standstill,
the operating fluid flows back into the delay chamber. Observe that
the intervals (a few minutes!) between starts are sufficient to obtain
a correct starting characteristic!

– Coupling temperature:
During steady operation, the coupling temperature must not exceed
85°C! Overheating may damage the coupling!
Please consult Voith Turbo, if the turbo coupling should be used for
ambient temperatures below -20°C!
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 9


Turbo Couplings with
Constant Fill

– Fusible plugs:
The fusible plugs protect the turbo coupling against damage due to
thermal overload. Switch off the drive motor immediately on
response of a fusible plug!
Use only original fusible plugs with the response temperature
indicated on the cover sheet of this operating manual!

– Sprayed-off and discharged operating fluid:


The fusible plugs respond in the event of thermal overload of turbo
coupling. The operating fluid is discharged through these fusible
plugs.
Please provide a catch pan of sufficient size, if required!

3.4 Staff qualification

The staff in charge of any work to be done on the coupling must


– be reliable,
– have the legal minimum age,
– be trained and instructed with regard to the intended work.

3.5 Product observation

We are under legal obligation to observe our products, also after shipment.
Please therefore inform us about anything that might be of interest to us. à You will find our
For example: address on page 6
– changed operating data
– experience gained with the unit
– recurring problems
– problems experienced with this installation and operating manual.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

10 Voith. Operating Manual


Turbo Couplings with
Constant Fill

4 Function, Types

4.1 Function

bladed wheels shell

Fig. 1

The Voith turbo coupling is a hydrodynamic coupling working to the Föttinger


principle. Its main components consist of two bladed wheels – the pump
impeller and turbine wheel – enclosed by a shell. Both wheels are provided
with bearings relative to each other. The power is transmitted virtually
without wear, there is no mechanical contact between the power-transmitting
parts. A constant amount of operating fluid is in the coupling.
The mechanical energy provided by the drive motor is converted to kinetic
energy of the operating fluid in the connected pump impeller. In the turbine
wheel this kinetic energy is converted back to mechanical energy.

Three conditions are to be considered with regard to the coupling function:

– Standstill:
The total operating fluid is resting
statically in the coupling.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to

Fig. 2
technical development.

Voith. Operating Manual 11


Turbo Couplings with
Constant Fill

– Starting condition:
The pump impeller accelerates the
operating fluid with increasing motor
speed causing a circulating flow in
the working chamber. The complete
blade chamber of turbine wheel is
flooded, starting to move as a result
of the kinetic energy of fluid flow.
The coupling characteristic deter-
mines the torque curve during
startup.

Fig. 3

– Nominal operation:
During nominal operation only the
torque required by the driven
machine is transmitted. The low
speed difference between pump
impeller and turbine wheel (rated
slip) results in a steady flow
condition in the coupling.

Fig. 4

4.2 Type designation

For hydrodynamic couplings with constant fill the type designation is à You will find the type
determined as follows: designation of your
turbo coupling on the
cover sheet of this
operating manual
1 2 3 4 5 6 7 8 9 10 11

Example: 750 T VVS01D


750 T VV S 01 D
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

12 Voith. Operating Manual


Turbo Couplings with
Constant Fill

1 Coupling size (profile diameter in mm)


possible sizes: 154, 206, 274, 366, 422, 487, 562, 650,
750, 866, 1000, 1150

2 Number of hydrodynamic circuits


T: single-circuit coupling
DT: double-circuit coupling

3 Material
"no code letter": Silumin
U: ferrous product

4 Delay chamber
"no code letter": without delay chamber
V: with delay chamber
VV: with enlarged delay chamber

5 Draining of delay chamber


"no code letter": time-dependent draining without
dynamic refill
F: with centrifugal valves (standard type
open on standstill)
Y: with dynamic refill

6 Shell
"no code letter": standard design
S: designed as annular chamber

7 Turbo coupling connection


"no code letter": designed for flexible connecting
couplings mounted on the outer
wheel side
N: designed for primary coupling flange and
flexible connecting coupling mounted on
the coupling shaft

8 Design status
"old": A, B, C, E, G, H, J
"new": 01, 02, 03, 04, 05, 06, 07, 08, 09, 10, …

9 Throttle plate
"no code letter": without throttle plate
D: with throttle plate

10 Design
"no code letter": standard design
-X: special design
-Z: special hydrodynamic design
Installation and Operating Manual 3626-011000 en.

11 possible supplementary information


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 13


Turbo Couplings with
Constant Fill

4.3 Design examples

4.3.1 Connecting coupling on the output side

Type T (basic type): Type T V:

Fig. 5 Fig. 6

Type T VV: Type T VVS:

Fig. 7 Fig. 8

Type DT : Type DT V:
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Fig. 9 Fig. 10

14 Voith. Operating Manual


Turbo Couplings with
Constant Fill

4.3.2 Connecting coupling on the input side

Type T N (basic type):

Fig. 11

Type T VN:

Fig. 12

Type T VVN:

Design 1
__ _ __ _ __

Design 2

Fig. 13

Type T VVSN:
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.

Design 1
Voith Turbo GmbH & Co. KG, Crailsheim.

__ _ __ _ __
Turbo Couplings with Constant Fill.

Design 2
Subject to modification due to
technical development.

Fig. 14

Voith. Operating Manual 15


Turbo Couplings with
Constant Fill

5 Tightening Torques

filler plug,
item 0390
fusible plug,
nozzle screw, item 0395/0260
item 0455/0456

fastening screw, fastening screw,


item 1830 item 0850

fixing bolt,
item 0050

sight glass,
item 0396

Fig. 15

ATTENTION!
Oil the screws slightly before inserting them!

5.1 Fixing bolts


The tightening torque applicable to fixing bolt (item 0050) depends on its
dimension of thread:

Thread: M8 M10 M12 M16 M20 M24 M30 M36 M42

Tightening torque
in Nm: 23 46 80 195 380 660 1350 2350 3750

Tightening torques apply to screws with property class 8.8 or higher (to
DIN EN 20898-1 / ISO 898-1) and of relevant shaft journal material.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

16 Voith. Operating Manual


Turbo Couplings with
Constant Fill

5.2 Fusible plugs, filler plugs, blind screws and


sight glasses

Tightening torque in Nm (Dimension of thread)

Coupling size Fusible plug, Filler plug, Blind screw, Sight glass,
item 0395/0260 item 0390 item 0394/0265 item 0396

154: 8 (M8) 13 (M10) 8 (M8) – –

206: 13 (M10) 20 (M12x1,5) 13 (M10) – –

274: 13 (M10) 30 (M14x1,5) 13 (M10) – –

366 to 650: 50 (M18x1,5) 80 (M24x1,5) 50 (M18x1,5) 50 (M18x1,5)

750 to 1150: 144 (M24x1,5) 235 (M36x1,5) 144 (M24x1,5) 144 (M24x1,5)

5.3 Fastening and nozzle screws

Tightening torque in Nm (Dimension of thread)


1) 1)
Coupling Fastening screw , Fastening screw , Nozzle screw,
size item 1830/0780 item 0850 item 0455/0456

154 9 (M6) – – – –

206 23 (M8) – – – –

274 62 (M12) – – – –

366 74 (M12) 23 (M8) 48 (M16x1,5)

422 62 (M12) 23 (M8) 48 (M16x1,5)

487 74 (M12) 23 (M8) 48 (M16x1,5)

562 62 (M12) 46 (M10) 48 (M16x1,5)

650 135 (M16) 46 (M10) 48 (M16x1,5)

750 135 (M16) 74 (M12) 48 (M16x1,5)

866, 1000 250 (M20) 23 (M8) – –

1150 580 (M27) 23 (M8) – –

1)
Screws with property class 8.8 or higher (to DIN EN 20898-1 / ISO 898-1) are
used.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 17


Turbo Couplings with
Constant Fill

6 Installation of Basic Coupling


Type T

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

– Outer wheel drive:


The coupling is mounted on the driven machine shaft and then, via a
flexible connecting coupling, coupled with the drive motor.

– Inner wheel drive (special case):


The coupling is mounted on the drive motor shaft and then, via a flexible
connecting coupling, coupled with the driven machine.

6.1 As delivered condition

– The turbo coupling is delivered complete with mounted connecting


coupling.
– The turbo coupling is without fill. Any operating fluid included in the scope
of supply is delivered in a separate container.
– Fixing bolt, holding disk and other accessories are supplied as loose
parts.
– One set of fusible plugs is supplied as spares.

6.2 Preparation

n Check the length of fixing bolt, if the length of shaft journal, on which the à Fig. 18, page 21
coupling is mounted, changed or was not indicated to Voith Turbo.
n Check radial runout of shaft journals of drive motor and driven machine.
n Clean fitting surfaces on shaft journals and hubs using emery cloth.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

18 Voith. Operating Manual


Turbo Couplings with
Constant Fill

n Apply a thin lubricant film to the shaft journals.

Note!
Please use a lubricant with the following characteristics:
– operating temperature range: -20°C…+180°C,
– water and wash-out resistant,
– protection against fretting corrosion and corrosion.

– Proposed lubricants:
Supplier Designation
Dow Corning Molykote D
Molykote G-Rapid plus
Molykote TP 42
Fuchs gleitmo 815
gleitmo 100 S
Liqui Moly LM 48
Optimol PASTE WHITE T
PASTE MP 3

n Insert the keys.

ATTENTION!
– Keys should be provided with a sufficient back clearance and
run smoothly in the keyways.
– Observe that the balancing method is the same for shaft and
hub. Our parts are marked to DIN ISO 8821 / ISO 8821:
H: Half key agreement
F: Full key agreement
– When using a shaft-hub connection with one (1) key and
balancing to half key agreement, with the key being longer than
the hub, reduce or shorten the key accordingly to avoid
unbalance.

n Prepare suitable tools and lifting appliances; observe the turbo coupling
weight!

Note!
The cover sheet indicates the turbo coupling weight. The weight is also
stamped on the outer diameter of coupling flange, if it exceeds 100kg.
Installation and Operating Manual 3626-011000 en.

WARNING!
Damaged slings (chains, ropes etc.) or those with insufficient carrying
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

capacity may break under load, with the consequence of most serious
or even fatal injuries!
Turbo Couplings with Constant Fill.

Check the lifting appliances and slings for


Subject to modification due to

– sufficient carrying capacity,


technical development.

– sound condition.

Voith. Operating Manual 19


Turbo Couplings with
Constant Fill

6.3 Mounting

Note!
We recommend to use the mounting and removal devices available at
Voith Turbo as accessory equipment for couplings from size 274.

ATTENTION!
The use of unsuitable working means and methods may cause damage
to property.
When mounting the coupling prevent the use of
– pressure plates,
– hammers,
– welding torches.

n Fix the coupling to a suitable


lifting appliance.

n Careful warming-up of the coup-


ling hub (to approx. 80°C) facili-
tates coupling mounting.

Fig. 16

n Position the coupling at the


relevant shaft journal.

n Insert the holding disk supplied.

Note!
– For couplings up to size 274
remove the circlip prior to
inserting the holding disk and
then reinsert it.
Installation and Operating Manual 3626-011000 en.

– For couplings from size 366 the


holding disk is secured by means
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

Fig. 17 of a roll pin against rotation.


Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

20 Voith. Operating Manual


Turbo Couplings with
Constant Fill

ATTENTION!
Depending on the design of shaft, the coupling hub must be in contact
with the shaft collar or the end face of shaft journal.

Couplings size 154 and 206: Couplings size 274 to 1150:


n Insert a suitable and slightly oiled n Oil the mounting spindle slightly. à Mounting devices:
threaded rod in the shaft of the n Mount the coupling on the shaft section 6.4, page 22
relevant machine. journal using the mounting
n Mount the coupling on the shaft spindle, the spacer tube and the
journal using a nut and a spacer holding disk.
tube.

holding disk

fixing bolt

roll pin

Fig. 18

n Check the proper seat of holding disk. Tighten the fixing bolt using the à Tightening torque:
specified tightening torque. section 5.1, page 16

ATTENTION!
The connecting coupling hub must either be in contact with the
relevant shaft collar or secured in axial direction using a set screw. It
is perhaps necessary to provide a spacer ring between hub and shaft
collar.

n Mount the flexible connecting coupling hub on the relevant shaft journal.
Careful warming up of the connecting coupling hub (to approx. 80°C)
facilitates mounting.
n Tighten the set screw in the connecting coupling hub, if necessary.
Installation and Operating Manual 3626-011000 en.

n Move the connecting coupling hub with the relevant machine next to the
turbo coupling. Observe proper seat of flexible elements in the
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

connecting coupling!
Turbo Couplings with Constant Fill.

n Fix the machine slightly.


Subject to modification due to

n Align the drive. à Section 8, page 25


technical development.

Voith. Operating Manual 21


Turbo Couplings with
Constant Fill

6.4 Mounting devices


The following mounting devices are available at Voith Turbo for turbo
couplings of basic type T:

n SW1 B C

A
L2

L1

Fig. 19

A: mounting spindle B: original holding disk


L1: total length C: coupling hub
L2: length of spacer tube
n: dimension of mounting
spindle thread
SW1: wrench size across flats

Coupling size L1 L2 n SW1

274 520 135 M10 17


M12 19
M16 24
M20 30

366, 422 520 190 M10 17


M12 19
M16 24
M20 30

487, 562, 650, 750 780 245 M16 24


M20 30
M24 36
M30 46
Installation and Operating Manual 3626-011000 en.

866, 1000, 1150 1150 480 M20 30


M24 36
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

M30 46
M36 55
Turbo Couplings with Constant Fill.

M42 65
Subject to modification due to
technical development.

22 Voith. Operating Manual


Turbo Couplings with
Constant Fill

7 Installation of Basic Coupling


Type TN

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

ATTENTION!
The use of unsuitable working means or methods may cause damage
to property.
When mounting the coupling prevent the use of
– pressure plates,
– hammers,
– welding torches.

This application is an outer wheel drive. Mount the primary coupling flange
on the motor shaft. Then connect the turbo coupling with the primary
coupling flange and couple it with the driven machine shaft through a flexible
connecting coupling.

7.1 As delivered condition

– The turbo coupling is delivered complete with mounted primary coupling


flange.
– The turbo coupling is without filling. Any operating fluid included in the
scope of supply is supplied in a separate container.
– Other accessories are supplied as loose parts.
– A set of fusible plugs is supplied as spares.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 23


Turbo Couplings with
Constant Fill

7.2 How to mount the coupling

n Make the necessary preparations according to section 6.2. à Page 18

fastening screw, connecting coupling


item 0780
set screw

primary coupling flange 1

set screw

Design 1
__ _ __ _ __

Design 2

set screw

primary coupling flange 2

Fig. 20

n Mount the primary coupling shaft on the motor shaft securing it with the
relevant set screw in axial direction. Careful warming-up of primary
coupling flange (to approx. 80°C) facilitates mounting.
n Mount the connecting coupling hub on the coupling shaft securing it with
the relevant set screw in axial direction.
n Position the turbo coupling in front of the primary coupling flange.
n In the event of complete balancing, balancing marks (e.g. 0/0, 1/1, 2/2
etc.) are provided at the outer periphery of turbo coupling and the primary
coupling flange. Observe that these balancing marks match!
n Push the external spigot of turbo coupling into the internal spigot of
primary coupling flange.
n Fix the turbo coupling to the primary coupling flange using the relevant à Tightening torque:
screws (item 0780). section 5.3,
n Insert the flexible element in the connecting coupling hub. page 17

WARNING!
Fix the slings (chains, ropes etc.) only to the drive motor!
Fixing the slings to the coupling may cause damage.
Installation and Operating Manual 3626-011000 en.

n Move the mounted drive motor/turbo coupling unit next to the driven
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

machine and bolt the drive motor slightly.


Align the drive. à Section 8,
Turbo Couplings with Constant Fill.

n
page 25
Subject to modification due to
technical development.

24 Voith. Operating Manual


Turbo Couplings with
Constant Fill

8 Alignment

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

8.1 Flexible connecting couplings

– A flexible connecting coupling couples the turbo coupling with a shaft


journal.
– After alignment, the positions of turbo coupling and shaft journal still vary.
The flexible connecting coupling takes up these misalignments.

8.1.1 Connecting coupling on the input side

Connecting couplings available at Voith Turbo for turbo couplings of basic


type T:

Flexible roller coupling Flexible element coupling


type ERK: type EEK-E:
L
T
|
DT

L L

Fig. 21 Fig. 22
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 25


Turbo Couplings with
Constant Fill

Flexible element coupling Flexible pad coupling


type EEK-M: type EPK:

L L
Fig. 23 Fig. 24

Flexible cam coupling Flexible cam coupling


type ENK-SX: type ENK-SV:

L L
Fig. 25 Fig. 26

8.1.2 Connecting coupling on the output side

Connecting couplings available at Voith Turbo for turbo couplings of basic


type TN:

Flexible cam coupling


type Nor-Mex, model G:
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to

L
technical development.

Fig. 27

26 Voith. Operating Manual


Turbo Couplings with
Constant Fill

8.2 Laid lengths and type allocations


turbo coupling / flexible connecting coupling
Laid lengths L for flexible connecting couplings, as shown in section 8.1:

Laid lengths L in mm

Coupling-
type ERK EEK-E EEK-M EPK ENK-SX ENK-SV Nor-Mex-G

154 T: 143 +1 - - - - - -

154 DT: 165 +1 - - - - - -

206 T: 183 +1 - - - - - -

206 DT: 223 +1 - - - 110,5 ±1,5 56,5 ±1,5 -

274 T: 255 +1 - - - 158,5 ±2 67 ±2 -

274 DT: 295 +1 159 ±2 67 ±2 - 158,5 ±2 67 ±2 -

366: - 159 ±2 67 ±2 - 158,5 ±2 67 ±2 176 ±1,0

422: - 173 ±2 72 ±2 102 ±1 173 ±2 72 ±2 198 ±1,5

487: - 190 ±2 88 ±2 106 ±1 190 ±2,5 87,5 ±2,5 221 ±1,5

562: - 221 ±2 103 ±2 116 ±1 221 ±2,5 102,5 ±2,5 267 ±2,0

650: - 274 ±2,5 126 ±2,5 152 ±1,5 271,5 ±2,5 125,5 ±2,5 310 ±2,5

750: - - - 163 ±1,5 276 ±2,5 - -

866: - - - 189 ±1,5 287,5 ±2,5 - -

1000: - - - 210 ±1,5 287,5 ±2,5 - -

1150: - - - 210 ±1,5 - - -

1150 DT: - - - 210 ±1,5 - - -

ATTENTION!
To avoid any axial constraining forces, it is absolutely necessary to
adhere to the laid lengths! Please observe, in particular, displacements
due to temperature changes.

8.3 Alignment tolerances


Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.

ATTENTION!
Turbo Couplings with Constant Fill.

– Undue misalignments cause material damage.


Subject to modification due to

– It is necessary to meet the values specified for radial and axial


technical development.

runout at all operating conditions.


– Please observe, in particular, displacements due to temperature
changes.

Voith. Operating Manual 27


Turbo Couplings with
Constant Fill

Note!
The smaller the radial and angular displacement between turbo coupling and
shaft journal the
– higher the lifetime and reliability of the unit,
– the better is smooth running.

Maximum permissible alignment tolerances apply to:

– radial runout in the radial plane of flexible elements (maximum


permissible radial deflection of dial gauge!)
– axial runout, measured over the largest connecting coupling diameter
(maximum permissible axial deflection of dial gauge!).

Maximum permissible alignment tolerances for the radial and axial


deflection of dial gauge when using the connecting couplings shown in
section 8.1:

Coupling size Speed range


in rpm

0…750 750…1200 1200…1800 1800…3600

154 to 487 0.6mm 0.4mm 0.3mm 0.2mm

562 to 1150 0.8mm 0.6mm 0.4mm 0.3mm

The values mentioned above describe the maximum permissible radial and
axial deflection of dial gauge!

ATTENTION!
Observe maximum permissible speed!

8.4 Alignment

Note!
For alignment support the motor feet using shims or foil sheets. It would be
advantageous to use claws with adjusting screws on the foundation for
lateral movement of the drive unit.
Installation and Operating Manual 3626-011000 en.

– Alignment methods and its accuracy:


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

Method Accuracy
Turbo Couplings with Constant Fill.

Subject to modification due to

LASER-optical very accurate


technical development.

dial gauges accurate

feeler gauge, depth gauge less accurate

28 Voith. Operating Manual


Turbo Couplings with
Constant Fill

– Proposal for fitting dial gauges:

Fig. 28 Fig. 29

Fig. 30 Fig. 31

– How to proceed:

n Mount the turbo coupling. à Section 6 and/or 7,


n Align input and output shaft with each other. page 18 and/or 23
n Fix input and output unit on the foundation.
n Check alignment after tightening all screws, correct alignment, if
necessary.
n Prepare an alignment certificate for the documentation.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 29


Turbo Couplings with
Constant Fill

9 Operating Fluids

ATTENTION!
– Unsuitable operating fluids may damage the turbo coupling
permanently!
– Consult Voith Turbo if you want to use an operating fluid not
mentioned (e.g. water, biologically degradable or fire-resistant
operating fluid).

Operating fluids which may be used:


– Hydraulic oils HLP 32 to DIN 51524, Part 2
– Lubricating oil CLP 32 to DIN 51517, Part 3
– Steam turbine oils LTD 32 to DIN 51515, Part 1
– HD engine oils SAE 10 W
– ATF type A Suffix A (TASA) and type Dexron II, IID, IIE, III, MERCON
M-891205 and M 921253

9.1 Requirements to be fulfilled by the operating fluid

– Viscosity class .............................. ISO VG 32 to DIN 51519

– Pourpoint ...................................... the limit is 4°C below actual minimum


ambient temperature or lower
2 -1
– Starting viscosity .......................... less than 15000mm s (cSt)

– Flash point.................................... greater than 180°C and at least 40°C


above response temperature of fusible
plugs

– Resistance to aging...................... aging-resistant refined product

– Compatibility with seals ................ NBR (Nitril-Butadien caoutchouc) and


FPM/FKM (fluor caoutchouc)

Advantageous additional qualities


Installation and Operating Manual 3626-011000 en.

– FE 8: D7,5 / 80-80 ........................ Abrasion of rolling elements < 30mg


Abrasion of cage < 100mg
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

30 Voith. Operating Manual


Turbo Couplings with
Constant Fill

9.2 Proposed operating fluids

Supplier Description Pourpoint Flash point Class


in °C in °C
Addinol Hydr. Oil HLP 32 -30 220 HLP
Agip Oso 32 -30 205 HLP
Blasia 32 -29 215 CLP
Aral Aral BG 32 -27 200 HLP
Degol BG 32 -27 200 CLP
Aseol Plus 16-110 -33 200 HLP
Autol Hydr. Oil HY-S 32 ISO -32 208 HLP
Avia Avia Fluid RSL 32 -27 214 HLP
Gear RSX 32 S -33 207 CLP
BP Energol HLP 32 -30 216 HLP
Energol HLP-HM 32 -30 216 HLP
Castrol Hyspin AWH-M 32 -42 214 HLP
Hyspin SP 32 -28 220 HLP
CEPSA CEPSA HIDROSIC HLP 32 -24 204 HLP
EP 125 -30 206 HLP
DEA Pentran 32 -30 210 HLP
Elf Elfolna 32 -27 210 HLP
Elfolna DS 32 -32 225 HLP
Esso Nuto H 32 -33 210 HLP
Fina Hydran VT 32 -30 214 HLP
Fuchs Renolin B 10 -27 190 HLP
Renolin MR 10 -27 200 HLP
Klüber Lamora HLP 32 -30 200 HLP
Kuwait Q8 Holst 32 -30 208 HLP
Petroleum Q8 Haydn 32 -30 208 HLP
Mobil Mobil SHC 524 <-63 234 HLP
DTE 24 -30 218 HLP
Optimol Hydo MV 32 -38 209 HLP
Shell Tegula Oil 32 -33 210 HLP
SRS Wiolan HS 32 -24 220 HLP
Salzbergen Wiolan HF 32 Turbofluid -27 200 HLP
Texaco Randol HD 32 -30 196 HLP
Total Azolla ZS 32 -21 220 HLP
Valvoline M5-C600 B -36 220 HLP

The above oil list is a recommendation and does not claim to be complete.
Installation and Operating Manual 3626-011000 en.

ATTENTION!
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

– The values mentioned for the pourpoint and flash point are
approximate values and data originating from the oil suppliers.
Turbo Couplings with Constant Fill.

These may vary and Voith Turbo will not accept any warranty
Subject to modification due to

claims! Country-specific production of basic oils may result in


different pourpoint, fire point and flash point values.
technical development.

– In the event of critical applications, we suggest to consult the


respective oil supplier!

Voith. Operating Manual 31


Turbo Couplings with
Constant Fill

9.3 Proposed operating fluids for special requirements

Operating fluid for the use in the food industry

Manufacturer Description Pourpoint Flashpoint Class


in °C in °C
Klüber Summit HySyn FG 32 -45 >230 HLP

Note: The USDA H1-Registration meets the FDA Requirements.

Fire-resistant operating fluid

Supplier Description Pourpoint Flashpoint Class


in °C in °C
Voith Turbo HIFluid -33 305 HFD-U
GmbH & Co. KG

Note: Voith-HIFluid is a fire-resistant fluid of the viscosity class ISO VG 46


and contains neither chlorinated hydrocarbons nor phosphorus acid
ester. The density of the fluid is lower than the density of water.

Biodegradable operating fluid

Supplier Description Pourpoint Flashpoint Class


in °C in °C
Voith Turbo EPFluid -36 230 HEES
GmbH & Co. KG

Note: Voith-EPFluid is a fast biodegradable fluid of the viscosity class


ISO VG 46 to VDMA 24568. The water risk class is 1 and the density
of the fluid is lower than the density of water.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

32 Voith. Operating Manual


Turbo Couplings with
Constant Fill

10 Fill, Filling Check and Draining

– The quantity and type of operating fluid used determine the turbo
coupling behavior substantially.
– A too high fill level leads to a higher load on the drive motor during
startup and in a higher stall torque.
– A too low fill level leads to a higher thermal load of coupling and a lower
stall torque.

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

CAUTION!
– Operating fluids may cause irritations or inflammation when in
contact with skin and mucous membranes.
– Please wear protective glasses for all work to be done in
connection with the operating fluid!
– Should you get any operating fluid in your eyes, rinse them
immediately using a lot of water and consult a physician!
– After you finished your work, clean your hands carefully with soap.

ATTENTION!
– Observe the fill level mentioned on the cover sheet of this operating
manual.
– Do not overfill! This would lead to an unpermissibly high internal
pressure in the coupling, which may destroy the coupling.
– Impurities in the operating fluid cause an increased wear of the
coupling. Make sure that any containers, funnels, filling tubes etc.,
used for filling the coupling, are clean.
– Do not mix the different types of operating fluids.
– Use only the operating fluid mentioned on the cover sheet of this
operating manual.
– Ensure that original seal rings are used and that these are in sound
condition.
Installation and Operating Manual 3626-011000 en.

Note!
You will find tightening torques in section 5 from page 16, please observe
02-08.1 / Rev. 7. K&E Printed in Germany.

Fig. 15 on page 16.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 33


Turbo Couplings with
Constant Fill

10.1 Coupling fill à You will find the fill


level (mineral oil)
– Turbo couplings are delivered without fill. provided on the cover
sheet of this operating
– The operating fluid included in the scope of supply is shipped in a manual
separate container.

10.1.1 How to fill couplings installed in horizontal position à Operating Fluids


Section 9, page 30
n Turn the coupling until one filler plug (item 0390) is on top; for couplings
of size 650 and 866 select the filler plug with the greatest distance to the à Fig. 15, page 16
next fusible plug.
n Unscrew the filler plug.
n Remove the top fusible plug (item 0395 or item 0260) for pressure
compensation.
n Fill in the specified operating fluid quantity through a fine screen (mesh
size ≤ 30µm) into the filler plug opening.
n Tighten the filler plug.
n If the coupling is provided with a sight glass (item 0396), tighten the
fusible plug.

direction of rotation direction of rotation


vertical vertical
axis z axis z
counting 3
3 direction counting
2
fill level 2 direction
1 1

sight glass or fusible plug sight glass or fusible plug

Fig. 32

n Turn the coupling until the operating fluid is just visible at the sight glass
(if existing) or until the operating fluid can be seen at the opening of the
(still) unscrewed fusible plug, but is not yet leaking out.
n Determine the number z of flange screws from the sight glass or fusible
plug to the vertical axis. The first screw is the one in counting direction,
after the intersection line through the sight glass or fusible plug and the
last screw is the one located before the vertical axis or just cutting it.
n For later level checks, record the number z of screws determined and
additionally mark the coupling or guard. z = _____
Installation and Operating Manual 3626-011000 en.

n If not yet done, tighten the fusible plug.


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

n After a test run (with guard!) check the coupling for leaks.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

34 Voith. Operating Manual


Turbo Couplings with
Constant Fill

10.1.2 How to fill couplings installed in vertical position

fusible plug/
blind screw

level mark

level check device

screw plug

connection for the level check device

Fig. 33

n Remove the two top screws (either two fusible plugs or two blind screws).
n Remove the screw plug.
n Fill in the specified operating fluid through a fine screen (mesh size
≤ 30µm) in to a screw opening. The other screw opening is provided for
pressure compensation.
n Fix the level check device to the connection provided for this purpose. à The level check
device is available as
n Provide the level mark at the coupling or guard for later level checks.
accessory at Voith
n Remove the level check device. Turbo for couplings
from size 366
n Tighten slackened screws.
Tightening torque for the screw plug: 30 Nm (M14x1,5).
n After a test run (with guard!) check the coupling for leaks.

10.2 Level check à You will find the fill


level (mineral oil)
provided on the cover
sheet of this operating
10.2.1 Level check for couplings installed in horizontal position manual

Note!
– Turbo couplings from size 422 are equipped with a sight glass in the
outer wheel; the position of sight glass is marked by an arrow.
– Turbo couplings of size 366 can optionally be equipped with a sight glass;
the position of sight glass is marked by an arrow.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.

n If a sight glass is not available, turn the coupling until a fusible plug is on
Turbo Couplings with Constant Fill.

top. Then remove this fusible plug.


Subject to modification due to

n Turn the coupling until the operating fluid is just visible at the sight glass
technical development.

or the operating fluid is not yet leaking out of the opening of unscrewed
fusible plug.

Voith. Operating Manual 35


Turbo Couplings with
Constant Fill

n Determine the number z of flange screws from the sight glass/fusible


à Fig. 32, page 34
plug up to the vertical axis; the first screws is the one in counting
direction, after the intersection line through the sight glass or fusible plug,
the last screw is the one located before the vertical axis or just cutting it.
n Compare the number of screws determined with the number of screws à Section 10.1.1,
determined during filling. Please observe also any mark additionally page 34
provided on the coupling or guard.
n Correct the fill level in case of variations!
n If a fusible plug has been unscrewed, retighten the same.
n After a test run (with guard!) check the coupling for leaks.

10.2.2 Level check for couplings installed in vertical position à Fig. 33, page 35

Note!
– The level check of couplings from size 366 is checked using a level
check device. This level check device is available at Voith Turbo as
accessories.
– Couplings up to size 274 are to be drained for level check and then to be
refilled.

n Unscrew a top screw (fusible plug or blind screw) for ventilation. à Fig. 33,
n Remove the screw plug. Section 10.1.2,
page 35
n Fit the level check at the connection provided for this purpose.
n Compare the level with the marked provided during filling.
n In case of variations, correct the fill level accordingly!
n Remove the level check device.
n Tighten slackened screws.
Tightening torque for the screw plug: 30 Nm (M14x1,5).
n After a test run (with guard!) check the coupling for leaks.

10.3 Draining the coupling

ATTENTION!
Installation and Operating Manual 3626-011000 en.

Operating fluids disposed of improperly may cause most severe


environmental damages! On disposal, please observe the applicable
02-08.1 / Rev. 7. K&E Printed in Germany.

laws and the manufacturer’s or supplier’s instructions!


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to

n Provide suitable containers to collect the operating fluid.


technical development.

36 Voith. Operating Manual


Turbo Couplings with
Constant Fill

10.3.1 How to drain couplings without delay chamber installed in


horizontal position

n Turn the coupling until one fusible plug is at the lowest point.
n Unscrew this fusible plug.
n For venting purposes, remove one filler or fusible plug opposite the
already unscrewed fusible plug.
n After draining the coupling, retighten the screws.

10.3.2 How to drain couplings with delay chamber installed in


horizontal position

n Turn the coupling until one fusible plug is at the lowest point.
n Unscrew this fusible plug.
n For venting purposes, remove one filler or fusible plug opposite the
already unscrewed fusible plug.
n Wait until the coupling working chamber is drained.
Couplings size 366 to 866: Couplings size 274, 1000 and 1150:
n Remove nozzle screw (item n Retighten fusible and filler plugs.
0455/0456).
n Switch on drive motor for
n Turn the coupling until the nozzle approximately half a minute to
screw opening is at the lowest one minute. The operating fluid
point. in the delay chamber drains into
the working chamber. Observe
n Wait until the delay chamber is
the safety regulations!
drained.
n Unscrew the fusible plug again.
n Tighten the nozzle screw.

n Turn the coupling until the fusible plug opening is at the lowest point.
n After draining the coupling working chamber, retighten the screws.

10.3.3 How to drain couplings installed in vertical position à Fig. 33, page 35

n For venting purposes, remove one blind screw or fusible plug on the top
side of coupling.
Up to coupling size 274: From coupling size 366:
n Unscrew one bottom blind n Remove the connection of level
screw or fusible plug. check device.
n Retighten screws after draining the coupling. Tightening torque for the
Installation and Operating Manual 3626-011000 en.

connection: 80 Nm (M24x1,5).
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Note!
Subject to modification due to

On account of the design, complete draining is not possible when the


technical development.

coupling is installed!

Voith. Operating Manual 37


Turbo Couplings with
Constant Fill

11 Commissioning

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

Notes!
– The turbo coupling may be used for any direction of rotation.
– The direction of rotation of driven machine may be specified! The
direction of rotation of motor must be in accordance with the specified
direction of rotation of driven machine!
– If the motor is started with star/delta connection, switchover from star to
delta connection should be effected after maximum 2…5s.
– In the event of a multi-motor drive you should determine the load of the
different motors. Great differences in motor load may be balanced by an
appropriate adjustment of the respective coupling fill levels. However,
prevent to exceed maximum permissible coupling fill level!

ATTENTION!
– Never operate the turbo coupling without operating fluid!
– On account of the type of bearings used for standard turbo
couplings of size 366, 422, 487, 562, 650, 750, 866 and 1150, at least
one standstill is required within a period of 3 months.
– On account of the type of bearings used for standard turbo
couplings of size 154, 206, 274 and 1000, at least one standstill is
required once a week.

n After installation and filling, put the coupling into operation, observe any
irregularities.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

38 Voith. Operating Manual


Turbo Couplings with
Constant Fill

12 Maintenance

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

Maintenance schedule:

Schedule Maintenance work

in intervals of 500 operating inspect the unit for irregularities


hours, every 3 months, at the (à Section 12.2)
latest

in intervals of 15000 operating change or check the operating fluid


hours (à Section 12.1)

on response of a fusible plug change all fusible plugs and the


operating fluid (à Section 12.3)

if required clean (à Section 12.4)

12.1 Operating fluid

n Change the operating fluid after 15000 operating hours or check it for à Section 9, page 30
aging! Consult the operating fluid supplier as to the permissible values. Section 10, page 33

12.2 Flexible connecting coupling

Note!
Extremely rapid wear of flexible elements is perhaps a sign of improper
alignment!

ATTENTION!
Installation and Operating Manual 3626-011000 en.

Realign the unit, if the coupled machines were displaced on


replacement of flexible elements.
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to

n Check the flexible elements of flexible connecting coupling regularly for


wear.
technical development.

n Replace the worn flexible elements in sets.

Voith. Operating Manual 39


Turbo Couplings with
Constant Fill

12.3 Fusible plugs

– The fusible plugs protect the turbo coupling against damage due to
thermal overload.
– When the response temperature is reached, the solder core of fusible à You will find the
plug melts and the operating fluid escapes. response
temperature of your
fusible plugs on the
Fusible plugs are identified by cover sheet of this
operating manual
– the response temperature engraved in °C,
– a color coding:

Response temperature Color coding

110°C yellow

125°C (120°C) brown

140°C red

160°C green

180°C blue

ATTENTION!
– Use original fusible plugs only with the response temperature
indicated on the cover sheet of this operating manual!
– Be sure not to replace any fusible plugs by blind screws!
– On response of a fusible plug replace all fusible plugs, change the à Tightening Torques
operating fluid. Section 5.2, page 17

Note!
A thermal monitoring system can prevent that operating fluid is sprayed off
(à section 16, page 49). Thermal monitoring systems are available at Voith
Turbo as accessories.

12.4 Outside cleaning

ATTENTION!
– Please observe that the cleaning agent is compatible with the NBR
and FPM/FKM sealing materials used!
Installation and Operating Manual 3626-011000 en.

– Do not use a high-pressure cleaning apparatus!


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

n Clean the coupling with a grease solvent, if necessary.


Subject to modification due to
technical development.

40 Voith. Operating Manual


Turbo Couplings with
Constant Fill

12.5 Bearing lubrication


The operating fluid is used for lubrication of turbo coupling bearings.

ATTENTION!
– On account of the type of bearing used for standard turbo
couplings size 366, 422, 487, 562, 650, 750, 866 and 1150, at least
one standstill is required within a period of 3 months.
– On account of the type of bearings used for standard turbo
couplings size 154, 206, 274 and 1000, at least one standstill is
required once a week.

Note!
– Couplings size 154, 206, 274, 366, 422, 487, 562, 650, 750 and 866 can
be provided with special bearings allowing continuous operation and are
filled with a lifetime grease.
– The Coupling size 1000 can be provided with special bearings requiring
only one standstill within a period of three months.
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 41


Turbo Couplings with
Constant Fill

13 Coupling Disassembly

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

Note!
This section describes the disassembly of turbo couplings of basic type T.
Couplings of basic type TN are disassembled in reverse order according to
section 7, page 23.

13.1 Preparation

n Prepare suitable tools and lifting appliances; observe the turbo coupling
weight!

Note!
The cover sheet indicates the turbo coupling weight. The weight is also
stamped on the outer diameter of coupling flange, if it exceeds 100kg.

WARNING!
Damaged slings (ropes, chains etc.) or those with insufficient carrying
capacity may break under load. This may cause most serious or even
fatal injuries!
Check the lifting appliances and slings for
– sufficient carrying capacity,
– sound condition.

n Fix the coupling to a suitable lifting appliance.


Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

42 Voith. Operating Manual


Turbo Couplings with
Constant Fill

13.2 Removal

Note!
We recommend to use the mounting and removal devices available as
accessories at Voith Turbo for couplings from size 274.

Couplings size 154 and 206:


n Remove the fixing bolt.
n Remove the coupling by inserting a suitable and slightly oiled screw into
the internal thread of holding disk.

à Removal devices:
section 13.3 and 13.4

puller spindle

substructure

Fig. 34

Coupling size 274: Couplings size 366 to 1150:


n Remove circlip, fixing bolt and n Remove fixing bolt and holding
holding disk. disk.
n Put the threaded ring, supplied n Apply lubricant to the thread of
together with the removal device, puller spindle.
into the coupling hub.
n Insert the puller spindle in the
n Secure the threaded ring using thread of coupling hub.
the circlip.
n Apply a lubricant to the thread of
puller spindle.
n Insert the puller spindle in the
Installation and Operating Manual 3626-011000 en.

internal thread of threaded ring.


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

n Support the puller spindle by a substructure.


Subject to modification due to

n Remove the coupling using the puller spindle.


technical development.

Voith. Operating Manual 43


Turbo Couplings with
Constant Fill

13.3 Mechanical removal devices


Removal devices available at Voith Turbo for turbo couplings of basic
type T:

SW Q A C

Fig. 35

A: puller spindle C: coupling hub


L: total length
Q: dimension of thread of puller
spindle
SW: wrench size across flats

Coupling sizes L Q SW

274 360 G¾ 36

366 350 G1 46

422, 487 460 G 1¼ 55

562, 650 650 G 1½ 60

750, 866, 1000, 1150 1000 G 2¼ 55

Note! à Hydraulic removal


To facilitate removal, Voith Turbo has hydraulic removal devices available devices:
for couplings from size 422. Section 13.4,
page 45
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

44 Voith. Operating Manual


Turbo Couplings with
Constant Fill

13.4 Hydraulic removal devices


Hydraulic removal devices available at Voith Turbo for turbo couplings of
basic type T:

~5

SW2 D SW1 A Q K C

Fig. 36

A: puller spindle SW1: wrench size across flats


D: pressing screw (spindle)
H: stroke SW2: wrench size across flats
K: piston (pressing screw)
L: total length C: coupling hub
Q: dimension of thread of puller
spindle

Coupling sizes L H Q SW1 SW2

422, 487 406 15 G 1-¼ 36 24

562, 650 580 15 G 1-½ 36 –

750, 866, 1000, 1150 1141 15 G 2-¼ 36 36

How to proceed:

1. Remove pressing screw (D).


2. Apply lubricant to the thread of puller spindle (A) and to the thread of
pressing screw (D).
3. Insert puller spindle (A) via hexagon SW1 up to the stop in the thread of
coupling hub (C).
Installation and Operating Manual 3626-011000 en.

4. Support puller spindle (A).


5. Insert pressing screw (D), stop ~5mm before the limit stop.
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

6. Remove pressing screw (D).


Turbo Couplings with Constant Fill.

7. Insert puller spindle (A) via hexagon SW1 up to the stop in the thread of
Subject to modification due to

coupling hub (C).


technical development.

8. Repeat steps 4 to 7 until the puller spindle moves in easily, then remove
it through SW1.

Voith. Operating Manual 45


Turbo Couplings with
Constant Fill

14 Trouble Shooting

DANGER!
Please observe, in particular, section 3 (Safety) when working on the
turbo coupling!

The following table is intended to help finding the cause of failures or


problems quickly and to take remedial action, if necessary.

Malfunction Possible cause(s) Remedial action

Starting behavior of Coupling is not filled Check and correct the à Section 10,
driven machine is not with the correct quantity fill level. page 33
as expected of operating fluid.

The operating Please consult Voith


1)
conditions have Turbo .
changed.

Driven machine does Driven machine is Eliminate blocking or


not reach the blocked or overloaded. cause of overload.
specified speed
Coupling is not filled Check and correct the à Section 10,
with the correct quantity fill level. page 33
of operating fluid.

Drive motor does not Changeover from star to Changeover from start
reach nominal delta too late. to delta should be
operation within the effected after 2…5s, at
expected time the latest.

Drive motor has an Have the drive motor


electrical or mechanical checked by authorized
defect. personnel.

Operating fluid leaks A fusible plug Clarify the overload à Section 12.3,
out of the coupling responded due to cause. Replace all page 40
overload (excess fusible plugs and
temperature). change the operating
fluid.

The coupling is leaking. Eliminate the leak,


check, in particular,
tightening torques and
Installation and Operating Manual 3626-011000 en.

seal rings of fusible and


filler plugs as well as
02-08.1 / Rev. 7. K&E Printed in Germany.

sight glasses and, if


Voith Turbo GmbH & Co. KG, Crailsheim.

necessary, check the


Turbo Couplings with Constant Fill.

switching element of
thermal switch unit. If
Subject to modification due to

you should not be able


technical development.

to eliminate the leak,


please consult Voith
1)
Turbo .

46 Voith. Operating Manual


Turbo Couplings with
Constant Fill

Malfunction Possible cause(s) Remedial action

An existing thermal The coupling was Clarify the overload à Section 16,
switch unit (MTS or overloaded. cause and avoid further page 49
BTS) responded overload.

Check the fill level à Section 10.2,


page 35
Uneven running of Foundation fixing is Retighten fixing.
unit loose.

The unit is not aligned. Align the unit. à Section 8,


page 25

Unit is not balanced. Clarify the cause and


eliminate unbalance.

Flexible elements of Replace the flexible à Section 12.2,


connecting coupling are elements in sets. page 39
defective.

Bearings are damaged. Eliminate the bearing


damage, consult Voith
1)
Turbo in the event of
a bearing damage on
the turbo coupling.
1)
Please consult Voith Turbo in the event of a malfunction which is not
included in this table.

1)
à Section 15, page 48
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 47


Turbo Couplings with
Constant Fill

15 Queries, Orders placed for Service


Engineers and Spare Parts

In the event of
– queries
– orders placed for service engineers
– spare parts orders
we need…

…the serial number and type


designation of turbo coupling.
B A

à You will find the serial number


and type designation either on
the outer wheel (A) or at the
coupling periphery (B).

Fig. 37

If an order is placed for a service engineer we need, in addition,


– the turbo coupling site,
– the address of a contact person,
– details of the occurred problem.

In the event of a spare parts order we need, in addition,


– the destination of spare parts shipment.

Please contact:

Voith Turbo GmbH & Co. KG


Startup Components
P.O. Box 1555
74555 Crailsheim
GERMANY
Installation and Operating Manual 3626-011000 en.

Phone: (07951) 32-0


Fax: (07951) 32-480
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

E-mail: startup.components@voith.com
WWW: www.startup-components.com
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

48 Voith. Operating Manual


Turbo Couplings with
Constant Fill

16 Monitoring Devices

16.1 MTS mechanical thermal switch unit


Function: à A separate operating
On excess temperature, the manual is available for
switching element releases a pin. the MTS
During rotation, the pin activates a
switch. This signal, for example,
switch may trip an alarm or switch off the
drive motor. The switching element
needs to be replaced.

ATTENTION!
In case of inner wheel drive and
blocking of driven machine, the
function is no longer guaranteed!
switching
element

Fig. 38
The MTS is provided for turbo couplings from size 274 DT.
The switch is available in two designs:
– enclosed [protection IP 65],
– suitable for use in potentially explosive atmospheres
[type of protection EEx d IIC T6].

16.2 BTS non-contacting thermal switch unit


Function: à A separate operating
On excess temperature, the manual is available for
switching element gives a specific the BTS
signal to the initiator. This signal is
transferred to an evaluator and may,
for example, trip an alarm or switch
off the drive motor. After the
coupling cooled down, the switching
initiator element is operable again and it is
not necessary to replace it.

switching element

Fig. 39
The BTS is provided for turbo couplings from size 206.
Installation and Operating Manual 3626-011000 en.

Switching element and initiator are


– cast in plastic,
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

– insensitive to dirt,
– suitable for use in potentially explosive atmospheres
Turbo Couplings with Constant Fill.

[type of protection: II 2G EEx ia IIC T6 (PTB 00 ATEX 2048 X)].


Subject to modification due to
technical development.

WARNING!
The control circuit of the evaluator is not intrinsically safe! If an intrinsically
safe control circuit is required, an appropriate transformer isolated barrier is
to be provided between evaluator and initiator!

Voith. Operating Manual 49


Turbo Couplings with
Constant Fill

17 Spare Parts Information Turbo


Coupling

Considering the great variety, please find in the following only the basic turbo
coupling designs with constant fill.

Note!
– You will find the type of your turbo coupling on the cover sheet of this
operating manual.
– If the scope of supply includes a flexible connecting coupling, you will
also find the type of flexible connecting coupling on the cover sheet of
this operating manual. Please find the allocation alternatives of turbo
coupling and flexible connecting coupling in section 8.2.
– Please observe sections 4.2 (Type designation) and 15 (Queries, Orders
placed for Service Engineers and Spare Parts).

ATTENTION!
A professional repair can only be guaranteed by the manufacturer!
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

50 Voith. Operating Manual


Turbo Couplings with
Constant Fill

17.1 Spare parts for type 154 T

0390

0190
0660

0090
0130
1845 1)

0670 0170

0070

0050
0040
0080

0300
0994
0395

Fig. 40

17.2 Spare parts for type 206/274 T

0390 0190

0230

0090
1845 1)
0670

0170 Example of connecting


coupling type ERK.

0070

0050
0040
0080
0130
0300
0265
0660
0994 à Connecting couplings:
0395 section 18, page 64
Fig. 41
1)
Optionally for connecting coupling type ERK, not shown as illustration!
Installation and Operating Manual 3626-011000 en.

Screws and Standard parts Wearing parts Coupling main parts


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

206 206 206


Item No. Description 154 274 Item No. Description 154 274 Item No. Description 154 274
Turbo Couplings with Constant Fill.

T T T T T T
Subject to modification due to

0050 Fixing bolt x x 0130 Grooved ball bearing x x 0040 Coupling hub x x
0070 Circlip x x 0170 Radial shaft seal ring x x 0080 Holding disk x x
technical development.

0230 Filler plug x 0395 Fusible plug x x 0090 Inner wheel x x


0265 Blind screw x 0660 Flexible element x x 0190 Shell x x
0390 Filler plug x x 0994 Seal x x 0300 Outer wheel x x
1845 Set screw x 0670 Hub x x

Voith. Operating Manual 51


Installation and Operating Manual 3626-011000 en.

52
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
Constant Fill

0050 1)
0396
Turbo Couplings with

0394
Standard parts
0390

Voith. Operating Manual


0994
0820 0170
0130
0320
0994 Wearing parts

2)
0260 0210 0140
0160

0080
0990
17.3 Spare parts for types T and TN from size 366

0300
0100
0090
0040
0190

Coupling main parts 0830

Fig. 42
Turbo Couplings with
Constant Fill

17.3.1 Spare parts for types 366/422/487/562/650/750/866/1000/1150 T


0390
0300 0260 2)
Upper part:
1830 0190 Example of connecting
1810 0090 coupling type EEK-M.
0990
0820 0210
0040
1845
0100
0080
0170
0050
0160
1800
Lower Part:
0830
Example of connecting
1820 0140 coupling type EEK-E.

0994 0130

0394 0320
0396 1)

Fig. 43

17.3.2 Spare parts for types 366/422/487/562/650 TN


0390
0260 2)
0300 0190
0780 0100
0990 0090
0820
0140
1845
0130
0770
0040

0170
0160
0830
0320 0210
0994 à Connecting couplings:
0394 section 18, page 64
0396 1)
Fig. 44
1)
From size 422 item 0396 is standard equipement, otherwise accessory!
2)
For sizes 366 and 422 in radial arrangement!

Screws and Standard parts Wearing parts Kupplungs-Hauptteile


Item No. Description T TN Item No. Description T TN Item No. Description T TN
0050 Fixing bolt x 0130 Grooved ball bearing x x 0040 Coupling hub / -shaft x x
Installation and Operating Manual 3626-011000 en.

0390 Filler plug x x 0140 Grooved ball bearing up to size 1000 x x 0080 Holding disk x
0394 Blind screw x x Cyl. Roller bearing at size 1150 x x 0090 Inner wheel x x
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

0396 Sight glass x x 0160 Radial shaft seal ring x x 0100 Rivet/clamping ring x x
Turbo Couplings with Constant Fill.

0780 Hex. Screw x 0170 Radial shaft seal ring x x 0190 Shell x x
Subject to modification due to

1830 Hex. Screw x 0210 Tolerance ring x x 0300 Outer wheel x x


1845 Set screw x 0260 Fusible plug x x 0770 Primary coupling flange x x
technical development.

0320 Tolerance ring x x 0830 Sealing ring cover x x


0820 O-Ring x x 0990 Connecting cover x x
0994 Seal x x 1800 Hub x x
1820 Flexible element x 1810 Ring / Flange x

Voith. Operating Manual 53


Turbo Couplings with
Constant Fill

17.4 Spare parts for types 274 TV/TVV

0390
1840

1830
0190
0230 Example of connecting
0090 coupling type ENK-SV.
1800
1820 0170

1845 1)

0070

0040
0050

0080 0130

0300 0265
0410
1810
0395
0994

Fig. 45
1)
Optional!
à Connecting couplings:
section 18, page 64

Screws and Standard parts Wearing parts Coupling main parts


Item No. Description 274 274 Item No. Description 274 274 Item No. Description 274 274
TV TVV TV TVV TV TVV
0050 Fixing bolt x x 0130 Grooved ball bearing x x 0040 Coupling hub x x
0070 Circlip x x 0170 Radial shaft seal ring x x 0080 Holding disk x x
0230 Filler plug x x 0395 Fusible plug x x 0090 Inner wheel x x
0265 Blind screw x x 0994 Seal x x 0190 Shell x x
0390 Filler plug x x 1820 Flexible element x x 0300 Outer wheel x x
1830 Hex. Screw x x 0410 Delay chamber x x
1840 Sprinbg washer x x 1800 Hub x x
1845 Set screw x x 1810 Ring / Flange x x
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

54 Voith. Operating Manual


Installation and Operating Manual 3626-011000 en.
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
- blank page -

Voith. Operating Manual


Constant Fill
Turbo Couplings with

55
Installation and Operating Manual 3626-011000 en.

56
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
Constant Fill

0050
0455
0394 Standard parts
1)
Turbo Couplings with

0396
0390

Voith. Operating Manual


size 366

0994 0510
0820
0170 0130
0320
Wearing parts
0994

0260
0210
0140 0160

0080 0410

0800
17.5 Spare parts for types TV/TVV and TVN/TVVN from

0300
0100
0090
0040
0190
4)
1000
Coupling main parts
0830

Fig. 46
Turbo Couplings with
Constant Fill

17.5.1 Types 366/422/487/562/650/750/866/1000/1150TV/TVV


0390 0260 2)
5) 0190
0455
0300 0820
1830 0090
1810
1820 0210
1800
0040 Example of connecting
0080 0100 coupling type EPK.
0050
0170
0510 3) 0160
0800
0830
1870
1880 0140
1860 0130
0410 0320
0994
0394 1000 4)
0396 1)
Fig. 47
17.5.2 Types 366/422/487/562/650 TVN/TVVN
0390
0455 5) 0260 2)
0780 0190
Upper Part:
0100 Design 1
0800
(Long laid length)
0820 0090
3)
0510 0140
0770
0130

0770
0040
0410 0170
0160 Lower Part:
0320
0830 Design 2
0994
(Short laid length)
0300 0210
For type TVVN only.
0394
0396 1) 1000 4)

Fig. 48
1)
From size 422 item 0396 is standard equipement, otherwise accessory! à Connecting couplings:
2)
For sizes 366 and 422 in radial arrangement!
3)
For sizes 366 and 422 only!
section 18, page 64
4)
For type T…F… only, not shown as illustration!
5)
Up to size 866 only!
Screws and Standard parts Wearing parts Coupling main parts
Item No. Description TV TVN Item No. Description TV TVN Item No. Description TV TVN
TVV TVVN TVV TVVN TVV TVVN
0050 Fixing bolt x 0130 Grooved ball bearing x x 0040 Coupling hub / -shaft x x
0390 Filler plug x x 0140 Grooved ball bearing up to size 1000 x x 0080 Holding disk x
0394 Blind screw x x Cyl. Roller bearing at size 1150 x x 0090 Inner wheel x x
Installation and Operating Manual 3626-011000 en.

0396 Sight glass x x 0160 Radial shaft seal ring x x 0100 Rivet/clamping ring x x
0455 Nozzle screw x x 0170 Radial shaft seal ring x x 0190 Shell x x
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

0780 Hex. Screw x 0210 Tolerance ring x x 0300 Outer wheel x x


1830 Hex. Screw x 0260 Fusible plug x x 0410 Delay chamber x x
Turbo Couplings with Constant Fill.

1870 Hex. Screw x 0320 Tolerance ring x x 0770 Primary coupling flange x
Subject to modification due to

1880 Spring washer x 0510 O-Ring x x 0800 Bearing retaining ring x x


0820 O-Ring x x 0830 Sealing ring cover x x
technical development.

0994 Seal x x 1000 Valve insert x x


1820 Flexible element x 1800 Hub x
1810 Ring / Flange x
1860 Sheet-metal holder x

Voith. Operating Manual 57


Installation and Operating Manual 3626-011000 en.

58
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
Constant Fill

0050
0455
1)
0396
Turbo Couplings with

0394
Standard parts
0994 0390

Voith. Operating Manual


0510
0820 0170
0130
0320
Wearing parts
0994

2)
0260 0210 0140
0160

0080
17.6 Spare parts for types TVVS and TVVSN

0410
0800

0300
0100
0090
0040
0190
5) Coupling main parts
1000
0830

Fig. 49
Turbo Couplings with
Constant Fill

17.6.1 Spare parts for types 422/487/562/650/750/866 TVVS


0390 0260 2)
0455 6) 0300
1840 0190 Upper Part:
1830 0100 Example of connecting
0820 0090 coupling type ENK-SV.
0510 3) 0210
1820
0160
1845 4)
0170
0080
0050 0130
0040
1800
0410 0140
Lower Part:
0800
Example of connecting
1810 0830
coupling type ENK-SX.
0994 0320
0394
0396 1) 1000 5)

Fig. 50
17.6.2 Spare parts for types 422/487/562/650 TVVSN
0390
0260 2)
0455 6)
0190
0780
0100
0800 0090 Upper Part:
0820
0140
Design 1
1845
0130
Long laid length
0770
0040

0510 3)

0170
0770
0160
0410 0830 Lower Part:
0320 Design 2
0994 0210
Short laid length
0300
0394 1000 5)
0396 1)
Fig. 51
1)
From size 422 item 0396 is standard equipement, otherwise accessory!
2)
For size 422 in radial arrangement! à Connecting couplings:
3)
For size 422 only! section 18, page 64
4)
Optional for connecting couplings type ENK-SV and ENK-SX!
5)
For type T ... F ... only, not shown as illustration!
6)
Up to size 866 only!
Screws and Standard parts Wearing parts Coupling main parts
Item Item Item
No. Description TVVS TVVSN No. Description TVVS TVVSN No. Description TVVS TVVSN

0050 Fixing bolt x 0130 Grooved ball bearing x x 0040 Coupling hub / -shaft x x
Installation and Operating Manual 3626-011000 en.

0390 Filler plug x x 0140 Grooved ball bearing x x 0080 Holding disk x
0394 Blind screw x x 0160 Radial shaft seal ring x x 0090 Inner wheel x x
0396 Sight glass x x 0170 Radial shaft seal ring x x 0100 Rivet/clamping ring x x
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

0455 Nozzle screw x x 0210 Tolerance ring x x 0190 Shell x x


0780 Hex. Screw x 0260 Fusible plug x x 0300 Outer wheel x x
Turbo Couplings with Constant Fill.

1830 Hex. Screw x 0320 Tolerance ring x x 0410 Delay chamber x x


Subject to modification due to

1840 Spring washer x 0510 O-Ring x x 0770 Primary coupling flange x


1845 Set screw x 0820 O-Ring x x 0800 Bearing retaining ring x x
technical development.

0994 Seal x x 0830 Sealing ring cover x x


1820 Flexible element x 1000 Valve insert x x
1800 Hub x
1810 Ring / Flange x

Voith. Operating Manual 59


Turbo Couplings with
Constant Fill

17.7 Spare parts for type 154 DT

0390 0395

0660 0305

0090
1)
1845
0670 0040
Example of connecting
coupling type ERK
0070 0130
0170
0050

0080

0300 0390

0994
0395

Fig. 52
1)
Optional for connecting coupling type ERK! à Connecting couplings:
section 18, page 64

Screws and Standard-parts Wearing parts Coupling main parts


Item No. Description 154 DT Item No. Description 154 DT Item No. Description 154 DT
0050 Fixing bolt x 0130 Grooved ball bearing x 0040 Coupling hub x
0070 Circlip x 0170 Radial shaft seal ring x 0080 Holding disk x
0390 Filler plug x 0395 Fusible plug x 0090 Inner wheel x
1845 Set screw x 0660 Flexible element x 0300 Outer wheel x
0994 Seal x 0305 Outer wheel x
0670 Hub x
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

60 Voith. Operating Manual


Turbo Couplings with
Constant Fill

17.8 Spare parts for types 206 DT and 274 DT/DTV

0395

0660
0390
0300 Upper Part:
Example of type DT with
0070
connecting coupling
0670 type ERK.

0080 0040

0050
1845 1) 0130
1820 0170

1800
1810 Lower Part:
1830 0090 Example of type DTV with
1840 connecting coupling
0395 type ENK-SV.
0410
0390 0305
0994

Fig. 53
1)
Optional for connecting coupling type ENK-SV!
à Connecting couplings:
section 18, page 64

Screws and Standard parts Wearing parts Coupling main parts


Item No. Benennung DT/DTV Item No. Benennung DT/DTV Item No. Benennung DT DTV
0050 Fixing bolt x 0130 Grooved ball bearing x 0040 Coupling hub x x
0070 Circlip x 0170 Radial shaft seal ring x 0080 Holding disk x x
0390 Filler plug x 0395 Fusible plug x 0090 Inner wheel x x
1830 Hex. Screw x 0660 Flexible element x 0300 Outer wheel x x
1840 Spring washer x 0994 Seal x 0305 Outer wheel x x
1845 Set screw x 1820 Flexible element x 0410 Delay chamber x
0670 Hub x x
1800 Hub x x
1810 Ring / Flange x x
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 61


Installation and Operating Manual 3626-011000 en.

62
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
Constant Fill

0050 0390 Standard parts


Turbo Couplings with

0820 1)
0170 0396
0130

Voith. Operating Manual


0320 0395
0994 Wearing parts 0390

0994
1)
0396
0395 0820
0320 0140
0170

0080
17.9 Spare parts for types 1150 DT/DTV

0800
0180
0045
0300
0100
0090
0995
0040
0090
0100
0305
1)
Each coupling has at least one sight glass! Coupling main parts 0180
0800

Fig. 54
Turbo Couplings with
Constant Fill

1820 1830 1810 0300 0390 0130 0320 0045 0100 0090 0390

Upper Part:
1860
0305 Example of type DT with
connecting coupling
0800 0140
type EPK.
0180 0800

1800 0180

0080 0040
0170
0050

1280

1880 0320
Lower Part:
1250 Example of type DTV with
1870
connecting coupling
0100
type EPK.
1835

1840 1830 0410 0530 1280 0395 1250 0994 0995 0395
0396 1) 0396 1)
Fig. 55
1)
Each coupling has at least one sight glass!
à Connecting couplings:
section 18, page 64

Screws and Standard parts Wearing parts Coupling main parts


Item No. Description DT DTV Item No. Description DT DTV Item No. Description DT DTV
0050 Fixing bolt x x 0130 Cyl. Roller bearing x x 0040 Coupling hub x x
0180 Circlip x x 0140 Grooved ball bearing x x 0045 Threaded ring x x
0390 Filler plug x x 0170 Radial shaft seal ring x x 0080 Holding disk x x
0396 Sight glass x x 0320 Tolerance ring x x 0090 Inner wheel x x
0530 Hex. Screw x x 0395 Fusible plug x x 0100 Clamping ring x x
1830 Hex. Screw x x 0820 O-Ring x x 0300 Outer wheel x x
1835 Hex. Nut x x 0994 Seal x x 0305 Outer wheel x x
1840 Spring washer x x 1280 O-Ring for oil retaining ring x x 0410 Delay chamber x
1870 Hex. Screw x x 1820 Flexible element x x 0800 Sealing ring cover x x
1880 Spring washer x x 0995 Intermediate piece x x
1250 Oil retaining ring x x
1800 Hub x x
1810 Ring / Flange x x
Installation and Operating Manual 3626-011000 en.

1860 Sheet-metal holder x x


02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 63


Turbo Couplings with
Constant Fill

18 Spare parts information


Connecting couplings

18.1 Connecting coupling on the input side

18.1.1 Flexible cam coupling type ENK

Outer shaft hub, type ENK-SX Inner shaft hub, type ENK-SV

1800
1820 1800
1830 1820
1840 1830
1810 1840
1845 1) 1810

Fig. 56 Fig. 57
1)
Optional, not shown as illustration!

18.1.2 Flexible element coupling type EEK

Outer shaft hub, type EEK-E Inner shaft hub, type EEK-M
1845 1845
Installation and Operating Manual 3626-011000 en.

1800
1800
02-08.1 / Rev. 7. K&E Printed in Germany.

1820 1830
Voith Turbo GmbH & Co. KG, Crailsheim.

1820 1830
1840 1840
1810 1810
Turbo Couplings with Constant Fill.

Subject to modification due to

Fig. 58 Fig. 59
technical development.

64 Voith. Operating Manual


Turbo Couplings with
Constant Fill

18.1.3 Flexible packet coupling type EPK

1870 1880
1860
1820
1800
1830
1840 1810
Fig. 60
Screws and Standard-parts Wearing parts Coupling main parts
Item No. Description ENK EEK EPK Item No. Description Item No. Description ENK EEK EPK
1830 Hex. Screw x x 1820 Flexible element 1800 Hub x x X
1840 Spring washer x x 1810 Ring / Flange x x x
1845 Set screw x 1860 Sheet-metal holder x
1870 Hex. Screw x
1880 Spring washer x

18.2 Connecting coupling on the output side


18.2.1 Normex-coupling type G
1845

0770
1845 1845
1845
Turbo coupling

1816 1815
1811
Installation and Operating Manual 3626-011000 en.

0770 1820
1800
input side output side
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

Fig. 61
Turbo Couplings with Constant Fill.

Screws and Standard-parts Wearing parts Coupling main parts


Subject to modification due to

Item No. Description Item No. Description Item No. Description


1816 Socket head srec 1820 Flexible element 0770 Primary coupling flange 1
technical development.

1845 Set screw 0770 Primary coupling flange 2


1800 Hub
1811 Flange hub
1815 Claw ring

Voith. Operating Manual 65


Installation and Operating Manual 3626-011000 en.

66
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
Constant Fill
Turbo Couplings with

Voith. Operating Manual


- blank page -
Installation and Operating Manual 3626-011000 en.
Turbo Couplings with Constant Fill.
Voith Turbo GmbH & Co. KG, Crailsheim.
02-08.1 / Rev. 7. K&E Printed in Germany.
Subject to modification due to
technical development.
- blank page -

Voith. Operating Manual


Constant Fill
Turbo Couplings with

67
Turbo Couplings with
Constant Fill

19 Representatives
Voith Turbo GmbH & Co. KG

Within Germany: Saarland, Reg.-Bez. Croatia: Hungary:


Rheinland-Pfalz, See Representative in Slovenia Voith-Magyarorszag
Baden-Württemberg: Reg.-Bez. Trier: Járműtechnika Kft.
Hans Svendsen Vogel Antriebstechnik Czech Republic: Almási Pal utca 47
GmbH & Co. KG Ing.-Büro D. Vogel Audol spol.s.r.o 3300 Eger
Ing.- und Verkaufsbüro Nelkenweg 7 Veletržní 24 Hungary
Postfach 18 70 66914 Waldmohr 17000 Praha 7 Phone: +36-36-515740
70708 Fellbach Germany Czech Republic Fax: +36-36-411107
Germany Phone: +49-6373-3060 Phone: +420-2-20397334 E-mail: skovran@eger.voith.hu
Phone: +49-711-95753-0 Fax: +49-6373-6641 Fax: +420-2-33372496 WWW: www.voith.hu
Fax: +49-711-95753-40 E-mail: Vogel.Karl@t-online.de E-mail: firma@audol.cz
E-mail: mergenthaler.a - WWW: www.audol.cz Ireland:
@svendsen.de Berlin, Brandenburg, Voith Engineering Ltd.
Sachsen, Sachsen-Anhalt, Denmark: 6, Beddington Farm Road
Bavaria: Thüringen: Voith Danmark A/S Croydon, Surrey CRO 4XB
Erhard Sauerteig Voith Turbo GmbH & Co. KG Erhvervsparken 12 Great Britain
Industrievertretungen GmbH Am Borsigturm 52 4621 Gadstrup Phone: +44-208-6670333
Karl-Böhm-Straße 179 13507 Berlin Denmark Fax: +44-208-6670403
85598 Baldham Germany Phone: +45-46-141550 E-mail: Turbo.uk@voith.co.uk
Germany Phone: +49-30-43032290 Fax: +45-46-141551 WWW: www.voith.co.uk
Phone: +49-8106-3530-0 Fax: +49-30-43032291 E-mail: postmaster@voith.dk
Fax: +49-8106-3530-22 E-mail: Jochen.Drechsler Italy:
E-mail: info@sauerteig.com @Voith.com Finland: Voith Italia s.r.l., div. Industria
Masino Oy Via Ponte Di Legno, 3
Hessen, Reg.-Bez. Rhein- Kärkikuja 3 20134 Milano
Hessen, Mannheim, Heidel- 01740 Vantaa Italy
berg, Aschaffenburg, Alzenau, Europe without Finland Phone: +39-02-21591390
Gemünden, Lohr, Miltenberg, Phone: +358-9-476800 Fax: +39-02-21598288
Germany:
Thüringische Werra (Revier): Fax: +358-9-47680300 E-mail: voith_mi@voith.it
IGEMA Maschinen und E-mail: myynti@masino.fi
Austria:
Anlagen GmbH WWW: www.masino.fi Liechtenstein:
Indukont Antriebstechnik
Zur Hermwiese 26 See Switzerland
Ges.m.b.H.
61479 Glashütten France:
Zur Spinnerin 3
Germany Voith France S.A. Luxembourg:
1100 Vienna
Phone: +49-6082-950590 21 Boulevard du Champy Voith BTT S.A.
Austria
Fax: +49-6082-950595 Richardets 36, Square Louisa
Phone: +43-1-60120-0
E-mail: igema-glashuetten@ 93166 Noisy-le-Grand Cedex 1150 Brussels
Fax: +43-1-6043500
t-online.de France Belgium
E-mail: info@indukont.at
Phone: +33-1-48156900 Phone: +32-2-7626100
WWW: www.indukont.at
Niedersachsen, Hamburg, Fax: +33-1-48156901 Fax: +32-2-7626159
Bremen, Schleswig-Holstein, E-mail: voithfrance@voith.com E-mail: voith.btt@glo.be
Belgium:
Mecklenburg-Vorpommern: Voith BTT S.A.
Erich Rottmann KG Couplings for Marine Engines: Macedonia:
36, Square Louisa
Postfach 20 33 62 Ph. R. Gueroult See Slovenia
1150 Brussels
20223 Hamburg 13 Allee Beethoven
Belgium
Germany 95690 Nesles la Vallee Netherlands:
Phone: +32-2-7626100
Phone: +49-40-4017660 France Voith Turbo GmbH & Co. KG
Fax: +32-2-7626159
Fax: +49-40-40176625 Phone: +33-1-30347238 Branch Essen
E-mail: info@voithbtt.be
E-mail: info@rottmann-kg.de Fax: +33-1-30347458 II. Schnieringstraße 48
WWW: www.rottmann-kg.de 45329 Essen
Bosnia Herzegowina:
Great Britain: Germany
Via International d.o.o.
Nordrhein-Westfalen: Voith Turbo Limited Phone: +49-201-364730
Perovo 30
Voith Turbo GmbH & Co. KG 6, Beddington Farm Road Fax: +49-201-3647325
1241 Kamnik
Branch Essen Croydon, Surrey CRO 4XB E-mail: guenter.schulenberg
Slovenia
II. Schnieringstraße 48 Great Britain @voith.com
Phone: +386-1-839 50 90
45329 Essen Phone: +44-208-6670333
Fax: +386-1-839 50 91
Germany Fax: +44-208-6670403 Norway:
E-mail: t.klar@viaint.si
Installation and Operating Manual 3626-011000 en.

Phone: +49-201-364730 E-mail: Turbo.uk@voith.com IMI Industri og Miljoutstyr A/S


WWW: www.viaint.si
Fax: +49-201-3647325 WWW: www.voith.co.uk Helgesensgt. 50
E-mail: guenter.schulenberg 0553 Oslo 5
02-08.1 / Rev. 7. K&E Printed in Germany.

Community of independent
Voith Turbo GmbH & Co. KG, Crailsheim.

@voith.com Greece: Norway


States (CIS):
Christ. Boznos & Son S.A. Phone: +47-22372086
Turbo Couplings with Constant Fill.

Voith Representation Moscow


12, K. Mavromichali Street Fax: +47-22371424
Boljshoj Sucharevskij
Subject to modification due to

P.O.Box 80 136 E-mail: imi@c2i.net


Pereulok 26 (Stroenie 1)
18545 Piraeus
103051 Moscow
technical development.

Greece
Russia
Phone: +30-1-4225134
Phone: +7-095-2089816
Fax: +30-1-4225159
Fax: +7-095-2089817
E-mail: info@boznos.gr
E-mail: voith@online.ru
WWW: www.boznos.gr

68 Voith. Operating Manual


Turbo Couplings with
Constant Fill

Poland: Switzerland: Republic of South Africa: Mexico:


Voith Polska Sp.zo.o. Antriebe AG Voith South Africa (Pty.) Ltd. Valnamex S.A.
Majków Duży 74 Werkstraße 39 P.O. Box 751092 Presa Sta. Teresa No. 128
97-371 Wola Krzysztoporska 8630 Rüti ZH 2047 Gardenview Co. Irrigaciòn
Poland Switzerland Republic of South Africa Mexico, D.F. 11500
Phone: +48-44-6468848 Phone: +41-55-2506000 Phone: +27-11-6263580 Mexico
Fax: +48-44-6468520 Fax: +41-55-2506060 Fax: +27-11-6262327 Phone: +52-5-5575705
E-mail: voith.polska@voith.pl E-mail: antriebe@antriebe.ch E-Mail: info@voith.co.za Fax: +52-5-3955507
WWW: www.voith.pl WWW: www.antriebe.ch WWW: www.voith.co.za E-mail: valnamex@enter.net.mx

Portugal: Turkey: Senegal: Peru:


Voith Ibérica S.A. Endüstri Teknik Ltd. STI. See France See Chile
Largo da Lagoa, 15 J R/C Dto. Arjantin Caddesi 8/2
2795-116 Linda-a-Velha Gaziosmanpasa-Ankara Swaziland: U.S.A.:
Portugal Turkey See Republic of South Africa Voith Transmissions, Inc.
Phone: +351-21-4155204 Phone:+90-312-4276808 25 Winship Road
Fax: +351-21-4145937 Fax: +90-312-4276807 Tunesia: York, PA 17 402
E-mail: cristina.wottrich E-mail: info@endustriteknik.com See France U.S.A.
@voithiberica.com WWW: www.endustriteknik.com Phone: +1-717-7673200
Zambia: Fax: +1-717-7673210
Romania: See Republic of South Africa E-mail: information
Rovth Consulting S.R.L. @voithusa.com
173, Calea Calarasilor Africa: Zimbabwe: WWW: www.voithusa.com
Bl.42, Sc.2, Ap.47 See Republic of South Africa
Sector 3, Bucharest Algeria: Venezuela:
Romania See France Insa De Venezuela, C.A.
Phone: +40-21-3274188 Zona Industrial UD-321
Fax: +40-21-3210531 Botswana: America: Calle 8, Piso 01, Ofic. 03
E-Mail: rovth@fx.ro See Republic of South Africa 8015 Puerto Ordaz -
Argentina: Edo. Bolivar
Slovakia: Egypt: Mapeko S.R.L. Venezuela
Audol spol.s.r.o Copam Egypt for Cerrito 1266 - 2° Piso-Of. 9 Phone: +58-86-943707
Veletržní 24 Engineering & Agencies Casilla de Correo 5173 Fax: +58-86-944314
17000 Praha 7 33 El Hegaz Street 1010 Buenos Aires E-mail: insaven@telcel.net.ve
Czech Republic P.O.Box 5661 Argentina
Phone: +420-2-20397334 W. Heliopolis Phone: +54-11-48164824
Fax: +420-2-33372496 Cairo 11771 Fax: +54-11-48164806
E-mail: firma@audol.cz Egypt E-mail: mapeco@attglobal.net Asia:
WWW: www.audol.cz Phone: +20-2-2566299
Fax: +20-2-2594757 Brazil: Brunei:
Slovenia: E-mail: copam Voith Turbo Ltda. See Singapore
Via International d.o.o. @mailer.datum.com.eg Rua Friedrich von Voith, 825
Perovo 30 02995-000 São Paulo-SP Cambodia:
1241 Kamnik Gabon: Brazil See Singapore
Slovenia See France Phone: +54-11-39444622
Phone: +386-1-839 50 90 Fax: +54-11-39411447 Cyprus:
Fax: +386-1-839 50 91 Guinea: E-mail: info.turbo-brasil Voith Middle East Ltd.
E-mail: t.klar@viaint.si See France @voith.com P.O.Box 52303
WWW: www.viaint.si WWW: www.voith.com.br 3063 Limassol
Ivory Coast: Cyprus
Spain: See France Canada: Phone: +357-25-317713
Voith Ibérica S.A. Voith Transmissions Fax: +357-25-317716
C/ Avenida de Suiza, 3 Lesotho: Canada, Inc. E-mail: voith@voithcy.com
Póligono de Actividades See Republic of South Africa Head Office WWW: www.voithcy.com
Logísticas de Coslada (P.A.L.) 2-106 Rayette Road
28820 Coslada (Madrid) Mauretania: Concord, Ontario L4K 2G3 Hong Kong:
Spain See Spain Canada Voith Turbo Limited
Phone: +34-91-6707800 Phone: +1-905-7381829 908, Guardforce Centre
Fax: +34-91-6707840 Marocco: Fax: +1-905-7389462 3 Hok Yuen Street East
E-mail: cristina.wottrich See Spain E-mail: scott.mcelroy Hung Hom - Kowloon
@voithiberica.com @voithcanada.com Hong Kong
Mozambique: WWW: www.voithcanada.com Phone: +852-27744083
Sweden: See Republic of South Africa Fax: +852-23625676
Voith Nordic AB Chile: E-mail: voith@voith.com.hk
Installation and Operating Manual 3626-011000 en.

Domnarvsgatan 4 Namibia: Flender Cono Sur Limitada WWW: www.voith.com.hk


P.O.Box 83 15 See Republic of South Africa Galvarino Gallardo 1534
16308 Spånga-Stockholm 6640875 Providencia- India:
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.

Sweden Niger: Santiago, Chile Voith India Private Ltd.


Phone: +46-8-7955950 See France Phone: +56-2-2353249 Transmissions and Engineering
Turbo Couplings with Constant Fill.

Fax: +46-8-7601701 Fax: +56-2-2642025 P.O. Industrial Estate


Subject to modification due to

E-mail: mailbox@voithnordic.se E-mail: flender@flender.cl Nacharam-Hyderabad 501507


India
technical development.

Phone: +91-40-7171440
Fax.: +91-40-7171141
E-mail: info@voith-india.com
WWW: www.voith-india.com

Voith. Operating Manual 69


Turbo Couplings with
Constant Fill

Indonesia: Laos: Singapore: Voith Australia Pty. Ltd.


See Singapore See Singapore Voith Drive Systems (Pte.) Ltd. SYDNEY (New South Wales)
2, Pioneer Sector 3 SERVICE CENTRE
Iran: Lebanon: Jurong 11 Sleigh Place
Voith Iran Co., Ltd. See Cyprus Singapore 628341 Wetherill Park, NSW 2164
P.O.Box 19395-6365 Singapore AUSTRALIA
No. 6, Shangarf St. Macao: Phone: +65-861-5100 Phone: +61-2-97571555
Mirdamad Blvd. See Hong Kong Fax: +65-861-5052 Fax: +61-2-97564677
Teheran 15489 E-mail: sgvoith@pacific.net.sg E-mail: vtau2@voith.com.au
IRAN Malaysia:
Phone: +98-21-2256003 See Singapore Syria: Voith Australia Pty. Ltd.
Fax: +98-21-2256005 See Cyprus BRISBANE (Queensland)
E-Mail: mail@voithiran.com Myanmar: SERVICE CENTRE
WWW: www.voithiran.com See Singapore Taiwan R.O.C.: 20 Bernoulli Street
See Hong Kong Richlands, QLD 4077
Iraq: Oman: AUSTRALIA
See Cyprus See Cyprus Thailand: Phone: +61-7-33757000
See Singapore Fax: +61-7-33757300
Israel: People´s Republic of China: E-mail: vtau7@voith.com.au
P.B.A. Wiesner Ltd. See Hong Kong United Arabian Emirates:
P.O. Box 4622 See Cyprus Voith Australia Pty. Ltd.
Petach-Tikva 49277 Philippines: EMERALD (Queensland)
Israel See Hong Kong Vietnam: SERVICE CENTRE
Phone: +972-3-9052120 See Singapore Lot 2 Hawkins Place
Fax: +972-3-9052155 Qatar: Emerald, QLD 4720
E-Mail: mailnet@pba.co.il See Cyprus Yemen: AUSTRALIA
See Cyprus Phone: +61-7-49820200
Japan: Republic of Korea: Fax: +61-7-49820201
Fuji Voith Co., Ltd. Sae-Rim Voith Corporation E-mail: vtau6@voith.com.au
9F, Sumitomo Seimei Room #1408
Kawasaki Bldg. Dae Chong Building 143-48 Australia and Ozeania: Voith Australia Pty. Ltd.
11-27 Higashida-Chou, Samsung-dong, Kangnam-gu GLADSTONE (Queensland)
Kawasaki-Ku C.P.O. 9666 Australia and New Zealand: SERVICE CENTRE
Kawasaki-Shi, Kanagawa 210 135-090 Seoul Voith Australia Pty. Ltd. 10 Chapple street
Japan Republic of Korea PERTH (Western Australia) Gladstone, QLD 4680
Phone: +81-44-2460555 Phone: +82-2-5574368 SERVICE CENTRE AUSTRALIA
Fax: +81-44-2460660 Fax: +82-2-5637734 27 Sarich Court Phone: +61-7-49728211
E-mail: fvc-naka@fsinet.or.jp E-mail: vskorea@hananet.net Osborne Park, WA 6017 Fax: +61-7-49721577
AUSTRALIA E-mail: vtau5@voith.com.au
Jordan: Saudi Arabia: Phone: +61-8-92427007
See Cyprus See Cyprus Fax: +61-8-94467357
E-mail: vtau1@voith.com.au
Kuwait:
See Cyprus
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

70 Voith. Operating Manual


Turbo Couplings with
Constant Fill

20 Index

Alignment..............................................25 Mounting devices ............................20, 22


Alignment tolerances ............................27 Multi-motor drive ...................................38
As delivered condition
basic type T ....................................18 Oil list....................................................31
basic type TN..................................23 Operating fluid...................................9, 30
proposed operating fluids................31
Bearing lubrication ................................41 requirements...................................30
Order placed for a service engineer ......48
Catch pan .............................................10 Outer wheel drive ............................18, 23
Commissioning .....................................38 Overload .......................................8, 9, 10
Connecting couplings......................25, 64
Coupling temperature .............................9 Pourpoint ........................................30, 31
Power transmission.................................9
Design examples ..................................14 Primary coupling flange....... 53, 57, 59, 65
Disassembly .........................................42 Product observation ..............................10
Draining ................................................36 Proper use ..............................................6
horizontal position with
delay chamber ................................37 Qualification ..........................................10
horizontal position without Queries .................................................48
delay chamber ................................37
vertical position...............................37
Removal................................................43
Removal devices...................................43
Filling ....................................................34 hydraulic ...................................44, 45
horizontal position...........................34
Removal devices mechanical................44
vertical position...............................35
Repair ...................................................50
Flash point ......................................30, 31
Representatives ....................................68
Flexible connecting couplings ...............25
Function................................................11
Safety .....................................................7
Fusible plugs............................... 8, 10, 40
Serial number .......................................48
Spare parts information.........................50
Guard......................................................8
1150 DT/DTV..................................62
154 DT............................................60
Hazards ..................................................7 154 T ..............................................51
206 DT and 274 DT/DTV ................61
Inner wheel drive...................................18 206/274 T .......................................51
Installation 274 TV/TVV ....................................54
basic type T ....................................18 T and TN from size 366 ..................52
basic type TN..................................23 TV/TVV and TVN/TVVN from
size 366 ..........................................56
Keys .....................................................19 TVVS and TVVSN ..........................58
Spare parts order ..................................48
Level check...........................................35 Standstill ...............................................38
horizontal position...........................35 Star/delta connection ............................38
vertical position...............................36 Starting characteristic .............................9
Symbols..................................................7
Maintenance .........................................39
bearing lubrication ..........................41 Temperature rise.................................8, 9
flexible connecting coupling ............39 Tightening torques ................................16
fusible plugs ...................................40 blind screw......................................17
operating fluid .................................39 fastening screws .............................17
outside cleaning..............................40 filler plug .........................................17
Maintenance schedule ..........................39 fixing bolt ........................................16
Manufacturer’s declaration......................4 fusible plug .....................................17
Monitoring devices ................................49 nozzle screw...................................17
BTS ................................................49 sight glass ......................................17
Installation and Operating Manual 3626-011000 en.

MTS................................................49 Trouble shooting ...................................46


Monitoring system.................................40 Type designation...................................12
Mounting ...............................................20
02-08.1 / Rev. 7. K&E Printed in Germany.
Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

Voith. Operating Manual 71


Voith Turbo GmbH & Co. KG
Startup Components
P.O. Box 1555
74555 Crailsheim
GERMANY
Phone: (07951) 32-0
Fax: (07951) 32-480
E-mail:
startup.components@voith.com
WWW:
www.startup-components.com
Installation and Operating Manual 3626-011000 en.

02-08.1 / Rev. 7. K&E Printed in Germany.


Voith Turbo GmbH & Co. KG, Crailsheim.
Turbo Couplings with Constant Fill.

Subject to modification due to


technical development.

G R O U P O F C O MP A N IE S

72 Voith. Operating Manual