Вы находитесь на странице: 1из 29

PROJECT: A & C APARTMENT

LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:

Design of Beam (EB)

1.0 Design Criteria

This calculation is for the design of the beam EB for the proposed apartment

1.1 Specifications

1.1.1 Design References

National Structural Code of the Philippines, Volume I - Buildings, Tower, and Other Vertical
Structures Fifth Edition 2001

1.1.2 Design Aids

Microsoft Excel

1.2 Design Loads

1.2.1 Dead Loads

Reinforced Concrete Unit Weight = 24 kN/m3


Super-Imposed Dead Load = 1.6 Kpa

1.2.2 Live Loads

Second Floor = 3.2 Kpa

1.3 Materials Property

1.3.1 Concrete
Concrete Compressive Strentgth f'c = 20.7 Mpa

1.3.2 Steel
Rebar Diameter db = 16 mm
Reinforcing bar Yield strength fy = 314 Mpa

1.3.3 Concrete Cover = 40 mm

2.0 Loading

Weight Computations
Span Length LS = 3.2 m

2.1 Weight of slab WS = 2.76 kN/m

Width of slab wS = 0.25 m


Thickness of slab tS = 0.100 m

2.2 Weight of beam Wb = 1.344 kN/m

Length of beam LB = 3.2 m

1
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
Area of beam A B = 0.04 m2

2.3 Total Weight Carried by EB WT = 4.104 kN/m


WT = S of weights

3.0 Analysis

3.1 Maximum Shear Computation


Simple Beam - Uniformly Distributed Load VMAX = 6.5664 kN
VMAX = WT * LS / 2

3.2 Maximum Moment Computation


Simple Beam - Uniformly Distributed Load MU = 5.25312 kN-m
MU = WT * LS2 / 8

3.3 Design of Steel Reinforcement considering flexure

Design Constants
Ultimate Moment MU = 5.25312 kN-m
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 314 Mpa (Gr. 40)
Reduction factor f = 0.90 (for flexure)
b1 = 0.85

Width b = 200 mm
Height h = 300 mm
Effective depth d = 252.0 mm

3.2.1 Computation of w w = 0.022174

MU = fbd2f'cw(1-0.59w)
w - 0.59w2 = 0.021884
w = 1.672741
w = 0.022174

3.2.2 Computation of rREQ

rMIN = 1.4 / fy rMIN = 0.0044586 USE

rREQ = w * f'c / fy rREQ = 0.0014618

rMAX = f*[0.85 * b1 * f'c / fy] [600 / (600+fy)] rMAX = 0.0234501

3.2.2 Computation No. of Steel Bars

AREQ = r * b * d AREQ = 224.71338 mm2

As = p * d2 / 4 As = 201.06193 mm2

n = AREQ / As n = 2

2
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
Use 2 nos. of 16mmØ

3
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
3.4 Check for Shear

Design Constants
Maximum Shear VMAX = 6.5664 kN
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 314 Mpa (Gr. 40)
Reduction factor f = 0.85 (for shear)
Allowable VC = 0.78 Mpa

Width b = 200 mm
Height h = 300 mm
Effective depth d = 252.0 mm
Stirrups Ø = 10.0 mm
Av = 78.5398163 mm2

3.4.1 Computation of VU

VU = VMAX - (WT * d) VU = 5.532192 KN

3.4.2 Computation of Actual V

Actual VC = VU / (.85 * b * d) Actual VC = 0.1291361 Mpa

3.4.2 Computation for Stirrups

s = Av * fy / ((VC - V) * b) s = 378.90416

Use 10mmØ Stirrups @ 200mm O.C.

4
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

ode of the Philippines, Volume I - Buildings, Tower, and Other Vertical

(Gr. 40)

5
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

6
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

7
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

Use 10mmØ Stirrups @ 200mm O.C.

8
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:

Design of Beam (B-1)

1.0 Design Criteria

This calculation is for the design of the beam EB for the proposed apartment

1.1 Specifications

1.1.1 Design References

National Structural Code of the Philippines, Volume I - Buildings, Tower, and Other Vertical
Structures Fifth Edition 2001

1.1.2 Design Aids

Microsoft Excel

1.2 Design Loads

1.2.1 Dead Loads

Reinforced Concrete Unit Weight = 24 kN/m3


Super-Imposed Dead Load = 1.6 Kpa

1.2.2 Live Loads

Second Floor = 3.2 Kpa

1.3 Materials Property

1.3.1 Concrete
Concrete Compressive Strentgth f'c = 20.7 Mpa

1.3.2 Steel
Rebar Diameter db = 16 mm
Reinforcing bar Yield strength fy = 314 Mpa

1.3.3 Concrete Cover = 40 mm

2.0 Loading

Weight Computations
Span Length LS = 3.5 m

2.1 Weight of slab WS = 35.328 kN/m

Width of slab wS = 3.2 m


Thickness of slab tS = 0.100 m

2.2 Weight of beam Wb = 1.344 kN/m

Length of beam LB = 3.5 m

1
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
Area of beam A B = 0.04 m2

2.3 Total Weight Carried by EB WT = 36.672 kN/m


WT = S of weights

3.0 Analysis

3.1 Maximum Shear Computation


Simple Beam - Uniformly Distributed Load VMAX = 64.176 kN
VMAX = WT * LS / 2

3.2 Maximum Moment Computation


Simple Beam - Uniformly Distributed Load MU = 56.154 kN-m
MU = WT * LS2 / 8

3.3 Design of Steel Reinforcement considering flexure

Design Constants
Ultimate Moment MU = 56.154 kN-m
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 314 Mpa (Gr. 40)
Reduction factor f = 0.90 (for flexure)
b1 = 0.85

Width b = 200 mm
Height h = 300 mm
Effective depth d = 252.0 mm

3.3.1 Computation of w w = 0.2802794

MU = fbd2f'cw(1-0.59w)
w - 0.59w2 = 0.233931
w = 1.414636
w = 0.280279

3.3.2 Computation of rREQ

rMIN = 1.4 / fy rMIN = 0.0044586

rREQ = w * f'c / fy rREQ = 0.018477 USE

rMAX = f*[0.85 * b1 * f'c / fy] [600 / (600+fy)] rMAX = 0.0234501

3.3.4 Computation No. of Steel Bars

AREQ = r * b * d AREQ = 931.2416 mm2

As = p * d2 / 4 As = 201.06193 mm2

n = AREQ / As n = 5

2
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
Use 6 nos. of 16mmØ

3
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
3.4 Check for Shear

Design Constants
Maximum Shear VMAX = 64.176 kN
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 314 Mpa (Gr. 40)
Reduction factor f = 0.85 (for shear)
Allowable VC = 0.78 Mpa

Width b = 200 mm
Height h = 300 mm
Effective depth d = 252.0 mm
Stirrups Ø = 10.0 mm
Av = 78.5398163 mm2

3.4.1 Computation of VU

VU = VMAX - (WT * d) VU = 54.934656 KN

3.4.2 Computation of Actual V

Actual VC = VU / (.85 * b * d) Actual VC = 1.2823216 Mpa

3.4.2 Computation for Stirrups

s = Av * fy / ((VC - V) * b) s = -490.9505

Use 10mmØ Stirrups @ 200mm O.C.

Prepared By:

Engr. Antonio M. Aganon, Jr.


Civil Engineer - Lic. No. 72628

4
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

ode of the Philippines, Volume I - Buildings, Tower, and Other Vertical

(Gr. 40)

5
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

6
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

7
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

Use 10mmØ Stirrups @ 200mm O.C.

8
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE: 18-Feb-20

Design of Column (C-1)

1.0 Design Criteria

This calculation is for the design of the beam EB for the proposed apartment

1.1 Specifications

1.1.1 Design References

National Structural Code of the Philippines, Volume I - Buildings, Tower, and Other Vertical
Structures Fifth Edition 2001

1.1.2 Design Aids

Microsoft Excel

1.2 Design Loads

1.2.1 Dead Loads

Reinforced Concrete Unit Weight = 24 kN/m3


Super-Imposed Dead Load = 1.6 Kpa

1.2.2 Live Loads

Second Floor = 3.2 Kpa

1.3 Materials Property

1.3.1 Concrete
Concrete Compressive Strentgth f'c = 20.7 Mpa

1.3.2 Steel
Rebar Diameter db = 16 mm
Reinforcing bar Yield strength fy = 314 Mpa (Gr. 40)

1.3.3 Concrete Cover = 40 mm

Column Size
Length = 0.2 m
Width = 0.3 m

2.0 Loading

Weight Computations

Tributary Area = L x W T.A. = 7.56 m2


Longitudinal = 2.8 m
Transverse = 2.7 m
2.1 Axial Loads at 2nd Floor

2.1.1 Weight of slab WS = 25.4016 kN

Thickness of slab tS = 0.100 m

1
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE: 18-Feb-20
2.1.2 Weight of beam Wb = 7.392 kN

Total Length of Beams LB = 5.5 m


Area of beam AB = 0.04 m2

2.1.3 Weight of Super-Imposed Dead Load SDL = 16.9344 kN

2.1.4 Weight of Live Load LL = 41.1264 kN

2.1.5 Weight of Column WC = 10.6848 kN

Height Ht = 5.3 m

2.1.6 Total Weight Carried by 2nd floor Column PU1 = 101.5392 kN


WT = S of weights(2nd flr)

2.2 Axial Loads at Attic

2.2.1 Weight of slab WS = 8.792 kN

Thickness of slab tS = 0.100 m

2.2.2 Weight of beam Wb = 2.2176 kN

Total Length of Beams LB = 4.4 m


Area of beam AB = 0.015 m2

2.2.3 Weight of Super-Imposed Dead Load SDL = 16.9344 kN

2.2.4 Weight of Live Load LL = 41.1264 kN

2.2.5 Weight of Column WC = 5.2416 kN

Height Ht = 2.6 m

2.2.6 Total Weight Carried by 2nd floor Column PU2 = 74.312 kN


WT = S of weights(attic)

2.3 Ultimate Axial Load PU = 175.8512 kN


PU = PU1 + PU2

3.0 Analysis

Design Constants
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 314 Mpa (Gr. 40)
Reduction factor f = 0.70
No. of Steel Bars n = 6

3.1 Considering Axial Load


PU = 0.80 * f * AG [.85 * f'c * (1/rG) + (rGfy)] PU = 791.43376 kN

3.1.1 Computation of rG rG = 0.0201062 > 1%


rG = AS / AG < 8%

2
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE: 18-Feb-20

PU = 791.4338 kN > 175.8512 kN Columns are SAFE

3
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE: 18-Feb-20

3.2 Design of Lateral Ties

Using 10mm Lateral Ties, spacing "s" must be the least value of the 3 conditions set

3.2.1 16 * Longitudinal Bar Ø = 256 mm

3.2.2 48 * Lateral Tie Bar Ø = 480 mm

3.2.3 Least Column Size = 200 mm

Adopt 10 mm Ø Lateral Ties at 200 mm O.C.

Prepared By:

Engr. Antonio M. Aganon, Jr.


Civil Engineer - Lic. No. 72628

4
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:

Design of Footing (FC-1)

1.0 Design Criteria

This calculation is for the design of the beam EB for the proposed apartment

1.1 Specifications

1.1.1 Design References

National Structural Code of the Philippines, Volume I - Buildings, Tower, and Other Vertical
Structures Fifth Edition 2001

1.1.2 Design Aids

Microsoft Excel

1.2 Design Loads

1.2.1 Dead Loads

Reinforced Concrete Unit Weight = 24 kN/m3


Super-Imposed Dead Load = 1.6 Kpa

1.2.2 Live Loads

Second Floor = 3.2 Kpa

1.3 Materials Property

1.3.1 Concrete
Concrete Compressive Strentgth f'c = 20.7 Mpa

1.3.2 Steel
Rebar Diameter db = 16 mm
Reinforcing bar Yield strength fy = 314 Mpa

1.3.3 Concrete Cover = 75 mm

Column Size
Length = 0.2 m
Width = 0.3 m

2.0 Loading

Weight Computations

Tributary Area = L x W T.A. = 7.56 m2


Longitudinal = 2.8 m
Transverse = 2.7 m
2.1 Axial Loads at 2nd Floor

2.1.1 Weight of slab WS = 25.4016 kN

1
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:

Thickness of slab tS = 0.100 m

2
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
2.1.2 Weight of beam W b = 7.392 kN

Total Length of Beams LB = 5.5 m


Area of beam AB = 0.04 m2

2.1.3 Weight of Super-Imposed Dead Load SDL = 16.9344 kN

2.1.4 Weight of Live Load LL = 41.1264 kN

2.1.5 Weight of Column WC = 5.2416 kN

Height Ht = 2.6 m

2.2 Axial Loads at Attic

2.2.1 Weight of slab WS = 8.792 kN

Thickness of slab tS = 0.100 m

2.2.2 Weight of beam Wb = 2.2176 kN

Total Length of Beams LB = 4.4 m


Area of beam AB = 0.015 m2

2.2.3 Weight of Super-Imposed Dead Load SDL = 16.9344 kN

2.2.4 Weight of Live Load LL = 41.1264 kN

2.2.5 Weight of Column WC = 3.8304 kN

Height Ht = 1.9 m

2.3 Total Axial Dead Load PDL = 61.96 kN


PDL = S of Dead Loads (2nd Flr and Attic) / 1.4

2.4 Total Axial Live Load PLL = 48.384 kN


PLL = S of Live Loads (2nd Flr and Attic) / 1.7

2.5 Total Axial Load PT = 110.344 kN


PT = PDL + PLL

3.0 Analysis

Design Constants
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 314 Mpa (Gr. 40)
Reduction factor f = 0.90 (for flexure)
b1 = 0.85

Soil Bearing Cap SBC = 85.00 kN/m2

3
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
Thickness of Footing a = 300.00 mm
Wt. of Ftg. (assumed) Wt. of ftg. = 10% of PT

3.1 Computation for the size of Square Footing B = 1.1949817 m


A=B*B Adopt 1.20m x 1.20m Square Ftg.

3.1.1 Computation of Rquired Area


A = (PT + Wt. of Footing) / SBC A = 1.4279812 m2

3.2 Design of Steel Reinforcement

3.2.1 Computation of Actual Ultimate Soil Pressure qU = 123.14672 kN/m2


qU = PU / (B * B)

3.2.3 Computation of Ultimate Moment MU = 66.68395 kN-m


MU = qU * B * [ (B-a) / 2 ] * [ (B-a) / 4 ]

3.2.3 Computation of d
d1 = a - c - (1.5 * db) d1 = 201 mm
d2 = a - c - (0.5 * db) d2 = 217 mm

3.2.4 Computation of w w = 0.0692791

MU = fbd2f'cw(1-0.59w)
w - 0.59w2 = 0.066447
w = 1.625636
w = 0.069279

3.2.5 Computation of rREQ

rMIN = 1.4 / fy rMIN = 0.0044586

rREQ = w * f'c / fy rREQ = 0.0045671

rMAX = f*[0.85 * b1 * f'c / fy] [600 / (600+fy)] rMAX = 0.0234501

Assumed d = 201 mm is safe for flexure

3.2.5 Computation for No. of Steel Bars

AREQ = rREQ * B * d AREQ = 1432.0679

n = AREQ / AS n = 8

Use 8 -16 mm Ø Both Ways

Prepared By:

4
PROJECT: A & C APARTMENT
LOCATION: KANLAON ST, ALABANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
DESIGNED BY: ENGR. ANTONIO M. AGANON, JR. DATE:
Engr. Antonio M. Aganon, Jr.
Civil Engineer - Lic. No. 72628

5
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

ode of the Philippines, Volume I - Buildings, Tower, and Other Vertical

(Gr. 40)

6
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

7
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

8
ANG COUNTRY HOMES, BRGY. PUTATAN, MUNTINLUPA CITY
18-Feb-20

Adopt 1.20m x 1.20m Square Ftg.