Вы находитесь на странице: 1из 2

v11.

2 Update 2
April 27, 2017

SOLVER
1. Allow the use of an .ASC file input for the definition of packed bed in the sediment
scour model.

2. Fixed an error where particles were going outside the domain, in cylindrical
co-ordinates.

3. Made corrections to area and volume fraction calculations for GMO STL sub-
components with shallow water mesh block.

4. Fixed an error that allows the scour model to now work even if the component
representing the packed sediment is turned off.

5. Fixed a bug in sediment history output.

6. Fixed a bug in FSI/TSE output, where some output for FSI/TSE was being written
even if components were not defined.

7. Made an improvement to allow heat transfer between 100% porous components


with fixed temperature and fluid.

8. Fixed an error in heat transfer calculation in solid components with temperature-


dependent properties when a zero velocity field is prescribed.

9. Made a correction in the restart logic for the air entrainment model without pressure
effects.

10. Fixed an error where restart simulation was failing with void region problems, when
the bubble model was on.

11. Fixed an error in grid overlay (GO) boundary logic for the sediment scour model
during restart.

12. Fixed a bug in heat transfer between overlapping components.

13. Fixed an issue in grid overlay (GO) boundary logic when a GO boundary is used in
several successive restart simulations.

14. Fixed an error that caused excessive air entrainment at mass-momentum sources.

15. Fixed an error where the solver was crashing with negative density, for the split-
Lagrangian VOF solver with air entrainment and bulking.

1
FLOW-3D and TruVOF are registered trademarks in the USA and other countries.
v11.2 Update 2
April 27, 2017

GRAPHICAL USERS INTERFACE


16. Remotely run simulations could connect to a remote version different from the client.
This would cause the RunnerServer to crash and the simulation would fail. Now a
check for version compatibility between client and remote is performed to prevent
incompatibility.

17. Deleting a baffle region while it’s being edited caused the GUI to crash. The GUI now
prevents baffles from being deleted while being edited interactively.

18. Fixed a GUI crash that resulted from setting global fluid initialization to “Wave
boundary.”

19. Fixed an issue that prevented the ServerAdmin from starting on Linux systems
running on German locale.

20. Fixed the default values for RFNC. All defaults in the GUI should be in CGS units but
the default for RFNC had accidentally been changed to SI units.

21. External .csv files could be linked to mass momentum sources although this
functionality was not available in the solver. This functionality has been removed
from the GUI.

22. The surface tension coefficient was disabled when the dynamic droplet size model
was activated. This was incorrect and has been fixed.

2
FLOW-3D and TruVOF are registered trademarks in the USA and other countries.

Вам также может понравиться