Diagrams of backflow

prevention devices

Type BA
Verifiable backflow preventer with
reduced pressure zone.

This backflow protection device is


commonly known as an “RPZ Valve
Assembly”.

A Type AA air gap should be provided


between the relief outlet port and the top of
the allied tundish.

Type BA device in normal flow condition.

Back Back
Pressure Siphonage
4 4

Type BA device in backflow condition.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type CA

Non-verifiable disconnector with


different pressure zones.

A Type AA air gap should be provided


between the relief outlet port and the top of
the allied tundish.

Type CA device in normal flow condition.

Back Back
Pressure Siphonage
3 3

Type CA device in backflow condition.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type DA

Anti-vacuum valve (or vacuum breaker).

The device must be fitted on a Type A


upstand so that the outlet is not less than
300mm above the free discharge point, or
spillover level of the appliance, and have no
valve, flow restrictor or tap on its outlet.

Type DA device in normal flow condition.

Back Back
Pressure Siphonage
- 3

Type DA device in backflow condition.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type DB

Pipe interrupter vent and moving


element.

The device is to be fitted with the lowest


point of the air aperture not less than 150
mm above the free discharge point, or
spillover level of the appliance, and have no
valve or restriction on its outlet.

Type DB device in normal flow condition.

Not less than


150 mm
minimum

Back Back
Pressure Siphonage
- 4

Type DB device in backflow condition.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type DC

Pipe interrupter with permanent


atmospheric vent.

Except for urinals, this device must be fitted


with the lowest point of the air aperture not
less than 150 mm above the free discharge
point, or spillover level of an appliance, and
have no valve, flow restrictor or tap on its
outlet.

In the case of urinals the device is to be


fixed not less than 150 mm above the
sparge outlet.

Type DC device in normal flow condition.

Not less
than150
mm min.

Back Back
Pressure Siphonage
Type DC device in backflow condition.
- 5

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type DUK1

Anti-vacuum valve combined with


verifiable check valve.

The device must be fitted on a Type B


upstand so that the outlet of the device is
not less than 300 mm above the free
discharge point, or spillover level of the
appliance, and have no valve, flow restrictor
or tap on its outlet.

Type DUK1 device. Back Back


Pressure Siphonage
2 3

Type EA

Verifiable single check valve.

Type EA device in normal flow condition.

Back Back
Pressure Siphonage
2 2
Type EA device in backflow condition.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type EB
Non-verifiable single check valve.

Type EB device.

Back Back
Pressure Siphonage
2 2

Type EC

Verifiable double check valve.

Type EC device.

Back Back
Pressure Siphonage
3 3

Type ED

Non-verifiable double check valve.

Type ED device.

Back Back
Pressure Siphonage
3 3

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type HA

Hose union backflow preventer.

Not to be used in new installations.

Only permitted outside houses for fitting to


existing hose union taps that do not
incorporate any backflow prevention device.

Type HA device in normal flow condition.

Back Back
Pressure Siphonage
2 3

Type HA device in backflow condition.

Type HC
Diverter with automatic return.

(Integral with some domestic appliance


applications only).

Back Back
Pressure Siphonage
- 3
Type HC device.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH
Type HUK1

Hose union tap incorporating verifiable


double check valve.

Not to be used in new installations.

Only permitted outside houses for


replacement of existing hose union taps that
do not incorporate any backflow prevention
device.

Back Back
Type HUK1 device. Pressure Siphonage
3 3

Type LA

Pressurised air inlet valve.

Use is limited to locations where operational


waste is acceptable, e.g. in gardens or
similar.

Back Back
Pressure Siphonage
- 2
Type LA device.

Type LB
Pressurised air inlet valve combined
with a check valve downstream.

Use is limited to locations where operational


waste is acceptable, e.g. in gardens or
similar.

Back Back
Pressure Siphonage
2 3
Type LB device.

Reproduced with kind permission of WRAS, Water Regulations Advisory Scheme, Fern Close, Pen-y-Fan
Industrial Estate, Oakdale, Newport, NP11 3EH