Air Filter Sellection Criteria

The following questions should be considered when selecting an appropriate air


filter for your system.

Application:
It should be well considered that where and what the filters will used for. It should
be a general air conditioning system for general purpose or it should be a
hospital where high quality air is needed.

Specifications of the contaminants that need to separated:


Charecteristic such as size and type of contaminants that the filter is required to deal with are major factors
in the suitability and sustainability of sellected filter.

Filtration efficiency that is required:


Efficiency of the filter is one of the important criteria that should be well considered. In order to avoid high
pressure drop and energy consumption suitable efficiency should be sellected for the enviroment.

Environmental Conditions:
Within each of our product ranges each individual filter should have been designed for specific purpose or
specific environmental conditions. Factors that the filter will be effected such as tempetature, humidty,
corrosion, etc., should be well considered.

Will the filter need to be incinerated at the end of its life?


If the filter is being used to separate toxic or harmful substances then it will typically have to be destroyed
through incineration. In this case, ensure that you select a filter which can be incinerated easily.

What level of pressure drop is acceptable?


For certain applications a filter’s pressure drop is vitally important to the entire system's performance.
Suitable filter with acceptable pressure drop should be selected for your systems.

Dust holding capacity of the filter


Filter selection should be done according to dust quantity that the filter will be exposed. With dust holding
capacity a filter should has a long service life.

What size of filter do you require?


A suitable filter which has all the specification should be in optimum dimensions. Meanwhile standart size
filters has price advantace and short delievery period compared to custom size filters.

Filter Housing:
Housing and replacement of the filter should be considered very carefully before the filter will be selected .
FANSET– Fan Coil Filters

Designed as prefilters for fan-coils and ventilation units.


Can be produced by synthetic media or washable
polyurethane filter media. Metal frame and rounded
wire types are avaible. Offers low filtration efficiency
with very low pressure drop.Avaible at standart size and
nonstandard sizes can be produced.
Filter Efficiency Class: G2 (EU2) - G3 (EU3)

PANSET– Panel Filters

Specially designed as first stage filters in ventilation units


for dry dust and as prefilter to higher efficiency filters.
Syhthetic filter media which is supported with metal
mesh placed into cardboard of metal frame. For low
pressure drop and high dust holding capacity filter
media is placed as zig-zag shape. For low air flow rate
straight and reuseable media models are avaible.
Avaible at standart size and nonstandard sizes can be
produced.
Filter Efficiency Class : G3 (EU3) - G4 (EU4)

DURAPAN– Metal Panel Filters

Designed for heavy duty industrial applications and


kitchen hoods as washable dust and grease filters. Filter
frame can be produced by galvanized,aluminum or
stainless steel and filter media consist of multiple layers
galvanized fine mesh. Filter media ensures high dust
holding capacity with very long service life. Avaible at
standart size and nonstandard sizes can be produced.
Filter Efficiency Class : G2 (EU2)
PANGLASS– Dust Stop Panel Filters

Used in ventilation units and industrial HVAC units as


dust and paint stop filters. Density of the glass fibre
media which is used inside the cardboard increase from
air intake to the clean air side.This progressive structure
provide high filtering performance.
Filter Efficiency Class : G2 (EU2) - G3 (EU3)

FineBag – Bag Filters

Made of three layer high quality synthetic media as fine


and high efficiency filtrers after first stage filtration.
Thermo-welded bags gurantee a perfect seal and
durability.The filter media is constructed of a series of
sealed bags for gaining high air flow at low pressure
drop. Frame can be produced by plastic or galvanized
metal.
Filter Efficiency Class : F5 (EU5) - F6 (EU6)
- F7(EU7) - F8(EU8) - F9(EU9)

DuraBag – Sythetic Bag Filter

DuraBag – Sythetic Bag Filters


Used as first stage filter or as prefilters to higher efficiency filters in ventilation
units with durable frame which can be produced variety of bags and bag depth
according to field of applications. Synthetic filter media and metal frame can
resist difficult operation conditions and perform high filtering efficiency.

RIGIAS

Deep pleat filters are designed for high efficiency filtration and high air flow rate for use in
hospitals, pharmaceutical industry etc. Instead of traditional mini pleat design corrugated
aluminium is used as separator.These separators with doubled edge give stiffness to the filter
and filter can resist to high operation temperature. Made of galvanized sheet with front flange
and double flange model is also avaible on request.
Filter Efficiency Class : F6 (EU6) - F7(EU7) - F8(EU8) - F9(EU9)
RIGIPAN

Designed for high efficiency filtration for use in hospitals,


pharmaceutical industry etc. Suitable for an air handling
unit in which space is limited. Can be used as high
efficiency filters instead of low efficiency current filters
in air conditioning systems.Alternative filters for
RIGICELL

Designed for high efficiency filtration for use in hospitals,


pharmaceutical industry etc. Suitable for an air handling
unit in which space is limited. Can be used as high
efficiency filters instead of low efficiency current filters
in air conditioning systems. Compact and robust
construction and growing efficiency during operation
can be used as final filter. Shockproof plastic frame
holding a glass micro fiber filter panel; medium is
pleated in order to create a rigid filter structure.
Filter Efficiency Class: F6 (EU6) - F7(EU7)
- F8(EU8) - F9(EU9)

CARBOMED - Granül Aktif Karbon

Granular media filter for organic odours which is based


on activated carbon for physical adsorption.
Avaible media for physisorption or chemisorption of
unwanted gaseous contaminants.

CARBOSORB

Designed for adsorption of odours (deodorization),


adsorption of VOC and low toxicity gases for use in
industrial and commercial air handling units.Best smell
and contaminants adsorption is assured by the possibility
of choosing the most suitable adsorption medium for each
request. Cartridges are made with painted expanded
sheet and filled with activated carbon which are
connected with a quick fastening system to the
supporting plate for 8 or 16 cartridges and gasket gives
maximum air tightness. Special design of the cartridge
makes maintenance and carbon change very easy.
CARBOMAX

Designed for adsorption of odours and gasses in air


conditioning application in industrial and commercial air
handling units. Plastic frame is filled with loose granular
or extruded activated carbon media which allows very
long service life. Suitable for heavy industrial
applications with high performance

RIGICARB

Designed for adsorption of odours and gasses with dust


filtration efficiency in air conditioning application in
industrial and commercial air handling units. F7
efficiency integrated non woven media which has two
layers containing small granules of activated carbon is
pleated and placed into plastic frame. A polyurethane
resin gurantees the seal between the filter pack and the
frame. In order to extend the service life of the filter it is
advised to use of G4-F5 prefilters before Rigicarb filters.

CARBOPAN - Activated Carbon Filters

Designed for adsorption of odours and gasses in air


conditioning application in industrial and commercial air
handling units. Activated carbon impregnated synthetic
media is pleated and place into water resistant
cardboard frame. Sythetic media is supported with metal
mesh and pleated for high filtration area. Avaible at
standart and out of standart size.Ideal solution to
improve indoor air quality for light industrial
applications.

Test & Validation

Validation: Testing and verifying the quality, reproducibility and reliability of facility and its design, systems
(HVAC/water/pressurized air etc.), equipments, process or product

HVAC (Heating, Ventilation, Air Conditioning) System Validation

+ HEPA Filter Leakage Test


The test according to “IEST-RP-CC034: HEPA And ULPA Filter Leak Tests” standard which is performed after
the montage of HEPA filters by using photometer and aerosol generator (with PAO poly-alpha olefin liquid) to
control whether there is leakage on filter surface, gasket and cabinet within acceptance criteria defined in the
standard. When there is no change in the system, this test must be performed at least once a year based on
the critically of processes in which HEPA filters are used. This test is also defined as Integrity or DOP test.
(HEPA Filter - High Efficiency Particulate Air Filter)

+ Airflow Volume Measurement And Calculation Of Air Change Rate


The test is performed to control whether the quality and quantity of airflow in the clean room is in conformity
with the air cleanliness class defined in “IEST-RP-CC006: Testing Clean Rooms” and “ISO 14644-3: Clean
Rooms And Associated Controlled Environments - Part 3: Test Methods” standards by measurement of
airflow volumes with balometer and calculating air change rate.

+ Differential Pressure Measurement


The test is performed to control whether the pressure differences, made to prevent contamination, between
the clean room and adjacent areas are in conformity with the acceptance criteria defined in “IEST-RP-CC006:
Testing Clean Rooms” and “ISO 14644-3: Clean Rooms And Associated Controlled Environments - Part 3:
Test Methods” standards by measurement of pressures with manometer.

+ Temperature And Humidity Measurement


The test is performed to control whether the temperature and relative humidity in the clean room are within
the acceptance criteria required by process/the standards or within the set value to prevent microbial
contamination in clean rooms according to “IEST-RP-CC006: Testing Clean Rooms” and “ISO 14644-3: Clean
Rooms And Associated Controlled Environments - Part 3: Test Methods” standards by measurement of
temperature and relative humidity with temperature-humidity meter.
+ Decontamination - Recycle Test
The test is performed to determine the time for clean-up of air in the clean room during the clean room
particle rate decreases from lower air cleanliness class to it’s own defined air cleanliness class defined in
“IEST-RP-CC006: Testing Clean Rooms” and “ISO 14644-3: Clean Rooms And Associated Controlled
Environments - Part 3: Test Methods” standards with a particle counter and a smoke generator.
+ Particle Count And Clean Room Classification

Вам также может понравиться