Академический Документы
Профессиональный Документы
Культура Документы
Datasheet
Bently Nevada Machinery Condition Monitoring
Description
The Proximitor Seismic Monitor:
n Protects machinery by continuously comparing
monitored parameters against configured alarm
setpoints to drive alarms.
n Communicates essential machine information to both
operations and maintenance personnel.
The Proximitor Seismic Monitor is a four-channel monitor that
accepts input from proximity and seismic transducers. It
conditions the signal to provide vibration and position
measurements and compares the conditioned signals with
user-programmable alarms.
You can program each channel using the 3500 Rack
Configuration Software to monitor and report:
n Radial vibration
n Thrust position
n Differential expansion
n Eccentricity
n REBAM
n Acceleration
n Velocity
n Shaft absolute
n Circular acceptance region
The monitor channels are programmed in pairs and can perform up to
two of the listed functions at a time. For example, Channels 1 and 2 can
perform one function while channels 3 and 4 perform another or the
same function.
Document: 143694
Rev. R
3500/42M Proximitor Seismic Monitor
Datasheet
Specifications Outputs
Inputs Front Panel LEDs
OK LED Indicates when the Proximitor Seismic
Signal Accepts from 1 to 4 proximity, Monitor is operating properly.
velocity or acceleration transducer TX/RX LED Indicates when the Proximitor Seismic
signals Monitor is communicating with other
Power consumption 7.7 watts, typical modules in the 3500 rack.
Gap filter -3 dB at 0.09 Hz The following table shows the frequency ranges
Not 1X filter 60 cpm to 15.8 times running speed if both channels of a channel pair are enabled:
Constant Q notch filter
Minimum rejection in stopband of - Dual Channel Frequency Response
34.9 dB
Output Without Filter Low or With
Smax 0.125 to 15.8 times running speed Type High Pass Integration
1X and 2X vector Constant Q Filter Filter
filter Minimum rejection in stopband of - RMS 10 to 30,000 Hz 10 to 9,155 10 to 9,155 Hz
57.7 dB Hz
1X and 2X Vector, Not 1X, and Smax parameters are Peak 3 to 30,000 Hz 3 to 9,155 10 to 9,155 Hz
valid for machine speeds of 60 cpm to 60,000 cpm. Hz
Spike high-pass 6-pole Elliptic Switch from higher Current shaft speed ≤ 1.05 x
(155 dB per decade, minimum) to nominal filter set (Nominal Shaft Speed)
Corner frequency is -0.1 dB. Shaft speed error Nominal filter set used
condition
Element bandpass 8-pole Butterworth
(155 dB per decade minimum) Physical
Corner frequency is -3 dB.
6-pole Elliptic Monitor Module (Main Board)
Rotor low-pass
(155 dB per decade, minimum) Dimensions 241.3 mm x 24.4 mm x 241.8 mm
(Height x Width x (9.50 in x 0.96 in x 9.52 in)
Corner frequency is -0.1 dB.
Depth)
Rotor, direct high- 1-pole Butterworth 0.91 kg (2.0 lb)
Weight
pass (18 dB per decade, minimum)
I/O Modules (non-barrier)
Corner frequency is -3 dB.
Dimensions 241.3 mm x 24.4 mm x 99.1 mm
Spike, direct low- Corner is -0.3 dB maximum. (Height x Width x (9.50 in x 0.96 in x 3.90 in)
pass Depth)
Gap low-pass 1-pole Butterworth Weight 0.20 kg (0.44 lb)
(18 dB per decade, minimum)
I/O Modules (barrier)
Corner frequency is -3 dB.
Dimensions 241.3 mm x 24.4 mm x 163.1 mm
1X amplitude Constant Q of 16.67 (Height x Width x (9.50 in x 0.96 in x 6.42 in)
Depth)
Stopband frequencies are 0.91 and
1.09 times the running speed. Weight 0.46 kg (1.01 lb)
Alarms
Alarm Setpoints Use Rack Configuration Software to
set alert levels for each value
measured by the monitor and danger
setpoints for any two of the values
measured by the monitor.
Alarms are adjustable from 0 to 100%
of full-scale for each measured value.
However, when the full-scale range
exceeds the range of the transducer,
the range of the transducer will limit
the setpoint.
Accuracy of alarm Within 0.13% of the desired value
setpoints
EMC
Electrical Safety
European Community Directive:
LV Directive 2014/35/EU
Standards:
EN 61010-1
RoHS
European Community Directive:
RoHS Directive 2011/65/EU
Maritime
ABS - Marine and Offshore Applications
DNV GL Rules for Classification – Ships,
Offshore Units, and High Speed and Light
Craft
CSA/NRTL/C
When used with I/O Class I, Zone 2: AEx/Ex nA nC ic IIC
module ordering T4 Gc;
options without Class I, Zone 2: AEx/Ex ec nC ic IIC
internal barriers T4 Gc;
Class I, Division 2, Groups A, B, C,
and D;
T4 @ Ta= -20˚C to +65˚C (-4˚F to
+149˚F)
When installed per drawing 149243
or 149244.
When used with I/O Class I, Zone 2: AEx/Ex nA nC ic [ia
module ordering Ga] IIC T4 Gc;
options with internal Class I, Zone 2: AEx/Ex ec nC ic [ia
barriers Ga] IIC T4 Gc;
Class I, Division 2, Groups A, B, C,
and D (W/ IS Output for Division 1)
T4 @ Ta= -20˚C to +65˚C (-4˚F to
+149˚F)
When installed per drawing 138547.
ATEX/IECEx
When used with I/O
module ordering II 3 G
options without Ex nA nC ic IIC T4 Gc;
internal barriers Ex ec nC ic IIC T4 Gc;
T4 @ Ta= -20˚C to +65˚C (-4˚F to
+149˚F)
When installed per drawing 149243
or 149244.
When used with I/O
module ordering II 3(1) G
options with internal Ex nA nC ic [ia Ga] IIC T4 Gc;
barriers Ex ec nC ic [ia Ga] IIC T4 Gc;
External termination blocks cannot be used with Internal Termination I/O Modules. When ordering I/O modules with
external terminations, order the external termination blocks and cable separately for each I/O module.
REBAM Channels
The following graphs show the maximum machine speed allowed for a monitor channel pair
configured for REBAM. The maximum speed depends on the number of rolling elements in the
bearing.
The graphs are generated with the following assumptions:
n The rotor lowpass filter corner is set at 3.2 times the shaft speed.
n The spike highpass filter corner is set at four times the element pass frequency for the outer race
(BPFO).