MODEL

3 1/ 2 DIGITAL METER (PROGRAMMABLE) S2-312PR

FEATURES
3 1/ 2 display: 1999
Accuracy: + _ 0.1% to _
+ 0.25%
Easy-to-wire. screw-type terminals
Outside dimension is DIN standard (96x48mm)
Low unit cost
TA IK

SPECIFICATION
Input Display 14.2mm (0.56") H, red LED
Variable to Input Max. Input over capability Amp. 3 x rated continuous
Input Range Display Range
be Measured Impedance 10 x rated 30 seconds
0 ~ 5V 1M 50 x rated 1 seconds
1 ~ 5V 1M Volt. 750V continuous
0 ~ 10V 1M
DC Accuracy DC range 0.1% F.S. 1 digit
0 ~ 1mA 100
4 ~ 20mA 10 0 ~ 1999 AC range 0.25% F.S. 1 digit
0 ~ 20mA 10 Programmable (Option: Depending on actual measuring)
AC 0 ~ 1A 0.1 Measuring mode Dual Slope
0 ~ 5A 0.1 Sampling time Abt. 0.8 sec. typically
0 ~ 110V 1M
TRMS 0 ~ 220V 1M Frequency range 45~400Hz for AC range
Over input indication "1"
Polarity Only "_" display
Display (Programmable process) Aux. power source AC 110V/220V 10%, 50/60Hz
DC 24V, 48V, 110V 15%
DP
JUMPER Power consumption AC 3VA, DC 3W
D1 D2 D3
Operating temperature range 0~60 oC
+
_

1
2
Sensor power supply DC 12V or 24V, 30mA
3
DIP. SWITCH 4 (Option function)
5
6
7 Storage temperature range _10~70oC
8

100PPM/ oC
9
Temperature coefficient
SPAN ZERO 60PPM/ C, 25oC+10oC
o
AD J. AD J.
Max. relative humidity 95%
Display PIN Dielectric strength (IEC 688) AC 2KV/1 minute
STAGE 1 2 3
(Full Scale) 4 5 6 7 8 9
_ _ _ _ _ _ _ _ Input to power terminals
1 1280 +
2 640 _ + _ _ _ _ _ _ _ AC 3KV/1 minute
_ _ _ _ _ _ _ _ All terminals to case
3 320 +
_ _ _ _ _ _ _ _
4 160 + Impulse (IEC 255-4) Common mode 1.2 x 50 S 4 KV
_ _ _ _ _ _ _ _
5 80 + Connection diagram See next page, figure A.
_ _ _ _ _ _ _ _
6 40 +
_ _ _ _ _ _ _ _ Dimensions See next page, figure 01.
7 20 +
_ _ _ _ _ _ _ _
8 10 +
_ _ _ _ _ _ _ _
9 5 +
_
*DIP Switch is + , Off, three mode, don't setting "Off"

ORDERING INFORMATION

S2-312PR-

Input Signal Measuring Range


EXAMPLE
Aux. Power Source
Measured range : DC 4~20mA
D: DC P1: 0~50mV A7: 0~1A 1: AC 110V/220V Display : 0 ~100.0%
A: AC P2: 0~60mV A8: 0~5A 2: DC 110V Aux. power source : AC 11 0 V / 2 2 0 V
T : TRMS P3: 0~5V V6: 0~110V 3: DC 48V Ordering model : S2-312PR-DP71
P4: 1~5V V7: 0~220V 4: DC 24V : 0 ~100.0%
Programmable
P5: 0~10V 00: Option 0: Option
P6: 0~1mA Display range
P7: 4~20mA
P8: 0~20mA

3
CONNECTION DIAGRAMS
Figure A.

( +) (_) (_) ( +)

1 2 3 4 5 6 7 8
Signal Input Aux. Source

7 8 AC 110V
6 8 AC 220V
6 7 If DC Source

OUTSIDE DIMENSION (UNIT:mm)

Figure 01. PANEL CUT-OUT

92 +
_0
0.8
48

+ 0.5
45 _ 0

96

7 98

113