Fluid Properties
Density ρ = 0.89 kg/m3
Viscosity µ = 300 cp
Calculation
1) Reynolds Number
Reynolds Number Re = 1
2)Power Requirement
Power Number Np = 1.4 Select the value from Power number chart based on
Reynolds number
Power Required P = 0.00 hp Use 5.5 for Rushton six blade turbine & 3.2 for
(Assuming 80% Loading) concave 180 degree turbine
3) Mixing Intensity
Pumping Number Nq = 0.72 Select the value from Pumping number chart based
on Reynolds number
Equivalent Diameter Teq = 8.76 f Use 0.72 for Rushton six blade turbine & 0.7
for concave 180 degree turbine
Volumetric flow rate Q = 8.7 f3/sec
4) Agitator required
No of Agitators Required = 2
Z/T = 1.57 Click Here
200
0.6
0.53 0.52 0.49 0.46
300 0.47 0.45 0.42 0.4
500 0.41 0.39 0.37 0.35
0.5
800 0.38 0.37 0.34 0.32
1200 0.36 0.34 0.32 0.3
3000
0.4
0.33 0.32 0.3 0.28
10000 0.33 0.32 0.29 0.27
0.3
0.2
0.1
0
100 1100 2100 3100 4100 5100 6100 7100 8100 9100 10100 11100
Reynolds Number
D/T = 0.25 D/T = 0.3 D/T = 0.4 D/T = 0.5
er HE3
D/T = 0.5
Wide Hydrofoil
Power No Power Number Curve for Wide Hydrofoil
Reynolds D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
No2.5
Power Number
100 2.28 2.24 2.15 2.11
200 1.78 1.75 1.69 1.65
2
300 1.56 1.53 1.48 1.45
500 1.3 1.29 1.24 1.23
800
1.5 1.14 1.12 1.09 1.08
1200 1.09 1.08 1.05 1.03
3000 1.06 1.05 1 0.98
100001 1.06 1.05 1 0.98
0.5
0
100 1100 2100 3100 4100 5100 6100 7100 8100 9100 10
Reynolds Number
D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
Hydrofoil
D/T=0.5
Pitched Blade Power Number curve for Pitched blade turbine
2.5
Power No
Power Number
0
100 1100 2100 3100 4100 5100 6100 7100 8100 9100 10100 11
Reynolds Number
e turbine
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
Reynolds Power No
No D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
100 5.5 5.5 5.5 5.5
200 5.5 5.5 5.5 5.4
300 5.5 5.5 5.5 5.5
500 5.5 5.5 5.5 5.5
800 5.5 5.5 5.5 5.5
1200 5.5 5.5 5.5 5.5
3000 5.5 5.5 5.5 5.5
10000 5.5 5.5 5.5 5.5
Reynolds Power No
No D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
100 3.6 3.6 3.6 3.6
200 3.2 3.2 3.2 3.15
300 3.2 3.2 3.2 3.2
500 3.2 3.2 3.2 3.2
800 3.2 3.2 3.2 3.2
1200 3.2 3.2 3.2 3.2
3000 3.2 3.2 3.2 3.2
10000 3.2 3.2 3.2 3.2
Chemineer HE3
Pumping Number curve for HE3 Impeller
Reynolds Power No
No0.6
D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
Pumping Number
0.1
0
100 1100 2100 3100 4100 5100 6100 7100 8100 9100 10100 1
Reynolds Number
mpeller
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
Pitched Blade
0.4
Reynolds
0.3 Power No
No D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
0.2 100 0.45 0.42 0.37 0.36
200 0.55 0.5 0.45 0.41
0.1 300 0.6 0.54 0.48 0.44
500 0.66 0.61 0.54 0.47
0 800 0.7 0.65 0.57 0.5
1200
100 0.74 21000.67 3100 0.6 4100 0.525100
1100 6100 7100 8100 9100 10100 11
3000 0.82 0.75 0.66 0.57
Reynolds Number
10000 0.88 0.8 0.68 0.6
drofoil
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
0.2
0.1
0
100 1100 2100 3100 4100 5100 6100 7100 8100 9100 10100
Reynolds Number
PBT
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
Reynolds Power No
No D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
100 0.7 0.7 0.7 0.7
200 0.72 0.72 0.72 0.72
300 0.72 0.72 0.72 0.72
500 0.72 0.72 0.72 0.72
800 0.72 0.72 0.72 0.72
1200 0.72 0.72 0.72 0.72
3000 0.72 0.72 0.72 0.72
10000 0.72 0.72 0.72 0.72
Reynolds Power No
No
D/T=0.25 D/T=0.3 D/T=0.4 D/T=0.5
100 0.68 0.68 0.68 0.68
200 0.7 0.7 0.7 0.7
300 0.7 0.7 0.7 0.7
500 0.7 0.7 0.7 0.7
800 0.7 0.7 0.7 0.7
1200 0.7 0.7 0.7 0.7
3000 0.7 0.7 0.7 0.7
10000 0.7 0.7 0.7 0.7