Вы находитесь на странице: 1из 2

Inline Filter MFM

Ports in L-configuration
up to 100 l/min, up to 280 bar
MFM MFM MFM MFM
35 55 75 95

1. TECHNICAL 1.6 FILTER SPECIFICATIONS


SPECIFICATIONS Nominal pressure 280 bar
1.1 FILTER HOUSING Temperature range -10 °C to +100 °C
Construction (-30 °C to -10 °C: pmax= 140 bar)
The filter housings are designed Material of filter head EN-GJS 400-15
Material of filter bowl Cold extruded steel
in accordance with international
Type of clogging indicator VD (differential pressure measurement up to
regulations. They consist of a filter 420 bar operating pressure)
head and a screw-in filter bowl. Pressure setting of the clogging indicator 5 bar (others on request)
Standard equipment: Bypass cracking pressure 7 bar (others on request)
 with bypass valve
 without clogging indicator connection 1.7 COMPATIBILITY WITH 1.9 FILTER CALCULATION /
 filters are supplied phosphated and HYDRAULIC FLUIDS ISO 2943 SIZING
primed  Hydraulic oils H to HLPD DIN 51524 The total pressure drop of a filter at a
1.2 FILTER ELEMENTS  Lubrication oils DIN 51517, API, certain flow rate Q is the sum of the
HYDAC filter elements are validated ACEA, DIN 51515, ISO 6743 housing Dp and the element Dp and is
and their quality is constantly calculated as follows:
monitored according to the following  Compressor oils DIN 51506
Dptotal = Dphousing + Dpelement
standards:  Biodegradable operating fluids
VDMA 24568 HETG, HEES, HEPG Dphousing = please refer to the
 ISO 2941, ISO 2942, ISO 2943, housing curve
ISO 3724, ISO 3968, ISO 11170,  Operating fluids with high water
ISO 16889 content (>50% water content) Dpelement = Q  SK*/1000  viscosity/30
on request (*gradient coefficient)
Filter elements are available with the
following pressure stability values: 1.8 MAINTENANCE INSTRUCTIONS HOUSING CURVE
Optimicron® (ON): 20 bar  Filter housings must be earthed. The housing curve applies to mineral
oil with a density of 0.86 kg/dm³ and a
1.3 SEALS  When using electrical clogging kinematic viscosity of 30mm²/s.
indicators, the electrical power supply
Perbunan (=NBR) to the system must be switched off 1
1.4 INSTALLATION before removing the clogging indicator 0.9

As inline filter connector. 0.8


0.7
∆p [bar]

0.6
1.5 SPECIAL MODELS AND 0.5
ACCESSORIES Symbol for hydraulic systems 0.4
0.3
Connection for a clogging indicator in 0.2
the head 0.1
0
0 10 20 30 40 50 60 70 80 90 100

Q [l/min]

The gradient coefficients in mbar/


(l/min) apply to mineral oils with a
kinematic viscosity of 30 mm²/s. The
pressure drop changes proportionally
to the change in viscosity.
MFM ON
1 µm 3 µm 5 µm 10 µm 15 µm 20 µm
35 50.2 21.3 17.1 13.7 10.0 7.44
55 26.0 12.3 9.9 7.90 5.17 3.84
E 7.556.2.2/11.16

75 16.7 8.4 6.75 5.4 3.33 2.48


95 13.2 6.74 5.4 4.33 2.62 1.92

1
2. MODEL CODE
2.1 COMPLETE FILTER
Type Filter material Size Pressure Head design Type of Filtration Type of Type Modification Supplementary
range connection rating clogging code number details
[µm] indicator*
MFM ON = 35 O= L= A = M18x1.5 1 W = without port, no 1 .x = B7 = standard
Optimicron® 55 280 bar flow in B = G 1/2 3 clogging indicator The latest cracking pressure
75 L-configuration D = M22x1.5 5 A = steel plug in version is of bypass 7 bar
95 10 indicator port always It is essential
15 B = visual supplied to include
Inlet: 20 C = electrical this information!
bore d15 D = visual/
with O-ring seal electrical V = FPM seal

2.2 REPLACEMENT ELEMENT 2.3 REPLACEMENT CLOGGING INDICATOR


Size Type Filtration Filter Supplementary Type Pressure Type of Modification Supplementary
rating material details setting clogging number details
[µm] indicator*
0035 D 001 ON = V= VD 5= A = steel plug .x = V=
0055 003 Optimicron® FPM seal standard in indicator port The latest FPM seal
0075 005 5 bar B = visual version is
0095 010 C = electrical always
015 D = visual/ supplied
020 electrical
* for other clogging indicators see brochure no. 7.050../..

3. DIMENSIONS

inlet

type code
label affixed

outlet

MFM Weight incl. Volume of


element [kg] pressure
chamber [l]
35 4.9 0.24
55 5.4 0.39
75 5.9 0.56
95 6.3 0.69

NOTE HYDAC Filtertechnik GmbH


The information in this brochure relates to the operating conditions and applications Industriegebiet
E 7.556.2.2/11.16

described. D-66280 Sulzbach/Saar


For applications or operating conditions not described, please contact the relevant Tel.: 0 68 97 / 509-01
technical department. Fax: 0 68 97 / 509-300
Subject to technical modifications. Internet: www.hydac.com
E-Mail: filter@hydac.com

Вам также может понравиться