Вы находитесь на странице: 1из 3

Dec 2019 Cutting‐2

DEC 2019 CUTTING‐2

NO OF 
Total 

RUNS
LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag
required 
L04 Z03‐Z07 MSB‐09‐5‐4‐2 CP‐AHU‐30301/A 1 4C x 35mm2 CU/XLPE/SWA/PVC 33 33 35‐M‐3 HOLD
33

Standard drum size ‐ 250m

Drum tag Drum length Total Cut length balance

NEW DRUM REQUIRED HOLD

NO OF 
Total 

RUNS
LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag
required 
L03 Z04 MSB‐09‐6‐3‐1 CSMSB‐09‐6‐3‐1 1 4C x 50mm2 CU/XLPE/SWA/PVC 48 48 50‐M‐1 DEC‐2A
L04 Z03‐Z07 MSB‐09‐5‐4‐2 MCO‐AHU‐40301/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 33 33 50‐M‐1 DEC‐2A
L04 Z04 MSB‐09‐6‐4‐2 MCO‐AHU‐40401/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 37 37 50‐M‐1 DEC‐2A
L04 Z12‐Z08 MSB‐11‐4‐4‐2 MCO‐AHU‐41201/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 42 42 50‐M‐1 DEC‐2A
L04 Z11‐Z07 MSB‐11‐3‐4‐2 MCO‐AHU‐41101/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 36 36 50‐M‐1 DEC‐2A
L05 Z12‐Z08 MSB‐11‐4‐5‐2 CP‐AHU‐51201 1 4C x 50mm2 CU/XLPE/SWA/PVC 55 55 50‐M‐1 DEC‐2A
L05 Z11‐Z07 MSB‐11‐3‐5‐2 CP‐AHU‐51101 1 4C x 50mm2 CU/XLPE/SWA/PVC 56 56 50‐M‐1 DEC‐2A
307

Standard drum size ‐ 250m

Drum tag Drum length Total Cut length balance

606 ‐ 67 ‐ 60 
50‐M‐1 307 172
NEW DRUM RECVD = 479
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


required 
L03 Z04 MSB‐09‐6‐3‐1 CSMSB‐09‐6‐3‐2 1 4C x 70mm2 CU/XLPE/SWA/PVC
4C x 70mm2 CU/XLPE/SWA/PVC 46 46 70‐M‐2 DEC‐2A
DEC 2A
L03 Z08 BD‐11‐7 (TOU‐L03) MSB‐11‐7‐3‐2 1 4C x 70mm2 CU/XLPE/SWA/PVC 50 50 70‐M‐2 DEC‐2A
L05 Z03‐Z07 MSB‐09‐5‐5‐2 CP‐AHU‐50301 1 4C x 70mm2 CU/XLPE/SWA/PVC 44 44 70‐M‐2 DEC‐2A
L05 Z04‐Z08 MSB‐09‐6‐5‐2 CP‐AHU‐50401 1 4C x 70mm2 CU/XLPE/SWA/PVC 39 39 70‐M‐2 DEC‐2A
L06 Z12‐Z08 MSB‐11‐4‐6‐2 CP‐AHU‐61201 1 4C x 70mm2 CU/XLPE/SWA/PVC 47 47 70‐M‐2 DEC‐2A
L06 Z11‐Z07 MSB‐11‐3‐6‐2 CP‐AHU‐61101 1 4C x 70mm2 CU/XLPE/SWA/PVC 64 64 70‐M‐2 DEC‐2A
290

Standard drum size ‐ 250m

Drum tag Drum length Total Cut length balance

462 ‐ (40+24) 
70‐M‐2 290 108
= 398
NEW DRUM RECVD
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


required 
L04 Z04 MSB‐09‐6‐4‐2 MCO‐AHU‐30401/A 1 4C x 95mm2 CU/XLPE/SWA/PVC 38 38 95‐M‐3 DEC‐2A
L06 Z04‐Z08 MSB‐09‐6‐6‐2 CP‐AHU‐60401 1 4C x 95mm2 CU/XLPE/SWA/PVC 44 44 95‐M‐3 DEC‐2A
L06 Z03‐Z07 MSB‐09‐5‐6‐2 CP‐AHU‐60301 1 4C x 95mm2 CU/XLPE/SWA/PVC 48 48 95‐M‐3 DEC‐2A

Standard drum size ‐ 250m

Drum tag Drum length Total Cut length balance

95‐M‐3 435 ‐ 94 = 341 224 117


NEW DRUM recvd
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


required 
L02 Z03 MSB‐09‐7‐2‐1 MCO‐HRU‐20301/A 1 4C x 120mm2 CU/XLPE/SWA/PVC 51 51 120‐D‐E (425) DEC‐2A
51

Standard drum size ‐ 250m

Drum tag Drum length Total Cut length balance

425‐57 
120‐D‐E (425) = 368 ‐  51 262
(30+25) = 313
Service Bldg Stock
Dec 2019 Cutting‐2

DEC 2019 CUTTING‐2

NO OF 
Total 

RUNS
LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag Date Marking done?
required
L02 Z03 BD‐09‐7 (TOU‐L02) MSB‐09‐7‐2‐3 1 4C x 240mm2 CU/XLPE/SWA/PVC 36 36 240‐M‐1 cut ‐ PENDING TO LAY

Standard drum size ‐ 250m

Drum tag Drum length Total Cut length balance

184 ‐ 105 
240‐M‐1 = 79 0
NEW DRUM 79

NO OF  Total 

RUNS
LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag
required 
L01 Z07‐Z11 BD‐11‐5 (TOU‐L01) MSB‐11‐5‐1‐2 2 4C x 300mm2 CU/XLPE/SWA/PVC 34 68 300‐yard‐1 DEC‐2A
L02 Z04 BD‐09‐6 (TOU‐L02) MSB‐09‐6‐2‐1 1 4C x 300mm2 CU/XLPE/SWA/PVC 34 34 300‐yard‐2 DEC‐2A
L03 Z07 BD‐11‐6 (TOU‐L03) MSB‐11‐6‐3‐2 1 4C x 300mm2 CU/XLPE/SWA/PVC 64 64 300‐D‐3 DEC‐2A
L03 Z12 BD‐11‐2‐1 (TOU‐L03) MSB‐11‐2‐3‐2 2 4C x 300mm2 CU/XLPE/SWA/PVC 68 136 300‐D‐3 DEC‐2A

Standard drum size ‐ 250m
Total Cut 
Drum tag Drum length balance
length
308 ‐ 107
300‐D‐3 200 1
Service Bldg Stock =201
FHP/3039‐G/16S 300‐yard‐1 83 68 15
FHP/3039‐G/16S 300‐yard‐2 47 34 13
Dec 2019 Cutting‐2

DEC 2019 CUTTING‐2
FIRST FLOOR

NO OF 
Total 

RUNS
LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag
required 
L01 Z07‐Z11 BD‐11‐5 (TOU‐L01) MSB‐11‐5‐1‐2 2 4C x 300mm2 CU/XLPE/SWA/PVC 34 68 300‐yard‐1 DEC‐2A

SECOND FLOOR

NO OF 
Total 

RUNS
LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag
required 
L02 Z03 MSB‐09‐7‐2‐1 MCO‐HRU‐20301/A 1 4C x 120mm2 CU/XLPE/SWA/PVC 51 51 120‐D‐E (425) DEC‐2A
L02 Z03 BD‐09‐7 (TOU‐L02) MSB‐09‐7‐2‐3 1 4C x 240mm2 CU/XLPE/SWA/PVC 36 36 240‐M‐1 cut ‐ PENDING TO LAY
L02 Z03 BD‐09‐7 (TOU‐L02) MSB‐09‐7‐2‐3 1 4C x 240mm2 CU/XLPE/SWA/PVC 43 43 240‐M‐1 cut ‐ PENDING TO LAY
L02 Z04 BD‐09‐6 (TOU‐L02) MSB‐09‐6‐2‐1 1 4C x 300mm2 CU/XLPE/SWA/PVC 34 34 300‐yard‐2 DEC‐2A

THIRD FLOOR
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


required 
L03 Z07 BD‐11‐6 (TOU‐L03) MSB‐11‐6‐3‐2 1 4C x 300mm2 CU/XLPE/SWA/PVC 64 64 300‐D‐3 DEC‐2A
L03 Z12 BD‐11‐2‐1 (TOU‐L03) MSB‐11‐2‐3‐2 2 4C x 300mm2 CU/XLPE/SWA/PVC 68 136 300‐D‐3 DEC‐2A
L03 Z04 MSB‐09‐6‐3‐1 CSMSB‐09‐6‐3‐1 1 4C x 50mm2 CU/XLPE/SWA/PVC 48 48 50‐M‐1 DEC‐2A
L03 Z04 MSB‐09‐6‐3‐1 CSMSB‐09‐6‐3‐2 1 4C x 70mm2 CU/XLPE/SWA/PVC 46 46 70‐M‐2 DEC‐2A
L03 Z08 BD‐11‐7 (TOU‐L03) MSB‐11‐7‐3‐2 1 4C x 70mm2 CU/XLPE/SWA/PVC 50 50 70‐M‐2 DEC‐2A

FOURTH FLOOR
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


R
N

i d
required 
L04 Z03‐Z07 MSB‐09‐5‐4‐2 CP‐AHU‐30301/A 1 4C x 35mm2 CU/XLPE/SWA/PVC 33 33 35‐M‐3 DEC‐2A
L04 Z03‐Z07 MSB‐09‐5‐4‐2 MCO‐AHU‐40301/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 33 33 50‐M‐1 DEC‐2A
L04 Z04 MSB‐09‐6‐4‐2 MCO‐AHU‐40401/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 37 37 50‐M‐1 DEC‐2A
L04 Z12‐Z08 MSB‐11‐4‐4‐2 MCO‐AHU‐41201/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 42 42 50‐M‐1 DEC‐2A
L04 Z11‐Z07 MSB‐11‐3‐4‐2 MCO‐AHU‐41101/A 1 4C x 50mm2 CU/XLPE/SWA/PVC 36 36 50‐M‐1 DEC‐2A
L04 Z04 MSB‐09‐6‐4‐2 MCO‐AHU‐30401/A 1 4C x 95mm2 CU/XLPE/SWA/PVC 38 38 95‐M‐3 DEC‐2A

FIFTH FLOOR
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


required 
L05 Z12‐Z08 MSB‐11‐4‐5‐2 CP‐AHU‐51201 1 4C x 50mm2 CU/XLPE/SWA/PVC 55 55 50‐M‐1 DEC‐2A
L05 Z11‐Z07 MSB‐11‐3‐5‐2 CP‐AHU‐51101 1 4C x 50mm2 CU/XLPE/SWA/PVC 56 56 50‐M‐1 DEC‐2A
L05 Z03‐Z07 MSB‐09‐5‐5‐2 CP‐AHU‐50301 1 4C x 70mm2 CU/XLPE/SWA/PVC 44 44 70‐M‐2 DEC‐2A
L05 Z04‐Z08 MSB‐09‐6‐5‐2 CP‐AHU‐50401 1 4C x 70mm2 CU/XLPE/SWA/PVC 39 39 70‐M‐2 DEC‐2A

SIXTH FLOOR
NO OF 

Total 
RUNS

LEVEL ZONES Fed From Load Description CABLE DESCRIPTION Cut length length  Drum tag


required 
L06 Z12‐Z08 MSB‐11‐4‐6‐2 CP‐AHU‐61201 1 4C x 70mm2 CU/XLPE/SWA/PVC 47 47 70‐M‐2 DEC‐2A
L06 Z11‐Z07 MSB‐11‐3‐6‐2 CP‐AHU‐61101 1 4C x 70mm2 CU/XLPE/SWA/PVC 64 64 70‐M‐2 DEC‐2A
L06 Z04‐Z08 MSB‐09‐6‐6‐2 CP‐AHU‐60401 1 4C x 95mm2 CU/XLPE/SWA/PVC 44 44 95‐M‐3 DEC‐2A
L06 Z03‐Z07 MSB‐09‐5‐6‐2 CP‐AHU‐60301 1 4C x 95mm2 CU/XLPE/SWA/PVC 48 48 95‐M‐3 DEC‐2A

Вам также может понравиться