MCT 10 Set-up Software

MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

Group Folder: Project

Drive Name: 1; FC-360 11.00kW Delhi


Connected Drive Information Database Information
Drive Series: FC-360 FC-360
Drive Type: 11.00kW 380-500V 11.00kW 380-480V
SW Version: 01.60 01.60
Option A No Option No Option
Option B No Option No Option
Option C0/E0 No Option No Option
Option C1/E1 No Option No Option
Drive Address: 1
Field-bus: Serial
Description

Parameter Group: 0-** Operation / Display

ID Name Setup 1 Setup 2 Unit


001 Language English English
003 Regional Settings International International
004 Operating State at Power-up Forced stop, ref=old Forced stop, ref=old
006 GridType 380-440V/50Hz 380-440V/50Hz
007 Auto DC Braking On On
010 Active Set-up Multi Set-up Multi Set-up
011 Programming Set-up Set-up 1 Set-up 1
012 Link Setups Linked Linked
014 Readout: Edit Set-ups / Channel
AAAAAE1Ahex AAAAAE2Ahex
016 Application Selection None None
020 Display Line 1.1 Small Reference [%] Reference [%]
021 Display Line 1.2 Small Motor current Motor current
022 Display Line 1.3 Small Power [kW] Power [kW]
023 Display Line 2 Large Frequency Frequency
024 Display Line 3 Large kWh Counter kWh Counter
030 Custom Readout Unit % %
031 Custom Readout Min Value 0.00 0.00
032 Custom Readout Max Value 100.00 100.00
037 Display Text 1
038 Display Text 2
039 Display Text 3
040 [Hand on] Key on LCP Enabled Enabled
042 [Auto on] Key on LCP Enabled Enabled
044 [Off/Reset] Key on LCP Enabled Enabled
050 LCP Copy No copy No copy
051 Set-up Copy No copy No copy
060 Main Menu Password 0 0

Parameter Group: 1-** Load and Motor

ID Name Setup 1 Setup 2 Unit


100 Configuration Mode Open Loop Open Loop
101 Motor Control Principle VVC+ VVC+
103 Torque Characteristics Constant torque Constant torque
106 Clockwise Direction Normal Normal
108 Motor Control Bandwidth Medium Medium
110 Motor Construction Asynchron Asynchron
114 Damping Gain 120 120 %
115 Low Speed Filter Time Const.0.53 0.53 s
116 High Speed Filter Time Const.0.53 0.53 s
117 Voltage filter time const. 0.122 0.122 s

Page: 1 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

120 Motor Power 7.5 kW - 10 hp 7.5 kW - 10 hp


122 Motor Voltage 415 415 V
123 Motor Frequency 50 50 Hz
124 Motor Current 14.06 14.06 A
125 Motor Nominal Speed 1440 1440 rpm
126 Motor Cont. Rated Torque 53.0 53.0 Nm
129 Automatic Motor Adaption (AMA)Off Off
130 Stator Resistance (Rs) 0.439 0.439 ohm
131 Rotor Resistance (Rr) 0.362 0.362 ohm
133 Stator Leakage Reactance (X1)1.704 1.704 ohm
135 Main Reactance (Xh) 47.71 47.71 ohm
137 d-axis Inductance (Ld) 3.650 3.650 mH
138 q-axis Inductance (Lq) 3.650 3.650 mH
139 Motor Poles 4 4
140 Back EMF at 1000 RPM 148 148 V
142 Motor Cable Length 50 50 m
143 Motor Cable Length Feet 164 164 ft
144 d-axis Inductance Sat. (LdSat)3.468 3.468 mH
145 q-axis Inductance Sat. (LqSat)3.468 3.468 mH
146 Position Detection Gain 100 100 %
148 Current at Min Inductance for 100
d-axis 100 %
149 Current at Min Inductance for 100
q-axis 100 %
150 Motor Magnetisation at Zero Speed
100 100 %
152 Min Speed Normal Magnetising 1.0[Hz] 1.0 Hz
155.0 U/f Characteristic - U 0 0 V
155.1 U/f Characteristic - U 0 0 V
155.2 U/f Characteristic - U 0 0 V
155.3 U/f Characteristic - U 0 0 V
155.4 U/f Characteristic - U 0 0 V
155.5 U/f Characteristic - U 0 0 V
156.0 U/f Characteristic - F 0 0 Hz
156.1 U/f Characteristic - F 0 0 Hz
156.2 U/f Characteristic - F 0 0 Hz
156.3 U/f Characteristic - F 0 0 Hz
156.4 U/f Characteristic - F 0 0 Hz
156.5 U/f Characteristic - F 0 0 Hz
160 Low Speed Load Compensation 100 100 %
161 High Speed Load Compensation 100 100 %
162 Slip Compensation 100 100 %
163 Slip Compensation Time Constant
0.10 0.10 s
164 Resonance Dampening 100 100 %
165 Resonance Dampening Time Constant
0.005 0.005 s
166 Min. Current at Low Speed 50 50 %
170 PM Start Mode Rotor Detection Rotor Detection
171 Start Delay 0.0 0.0 s
172 Start Function Coast/delay time Coast/delay time
173 Flying Start Disabled Disabled
175 Start Speed [Hz] 2.0 2.0 Hz
176 Start Current 14.06 14.06 A
178 Compressor Start Max Speed [Hz]
0.0 0.0 Hz
179 Compressor Start Max Time to5.0 Trip 5.0 s
180 Function at Stop Coast Coast
182 Min Speed for Function at Stop0.0[Hz] 0.0 Hz
188 AC Brake Gain 1.4 1.4
190 Motor Thermal Protection No protection No protection
193 Thermistor Source None None

Parameter Group: 2-** Brakes

ID Name Setup 1 Setup 2 Unit


200 DC Hold/Motor Preheat Current
50 50 %
201 DC Brake Current 50 50 %
202 DC Braking Time 10.0 10.0 s

Page: 2 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

204 DC Brake Cut In Speed 0.0 0.0 Hz


206 Parking Current 100 100 %
207 Parking Time 3.0 3.0 s
210 Brake Function Off Off
211 Brake Resistor (ohm) 36.0 36.0 ohm
212 Brake Power Limit (kW) 11.000 11.000 kW
214 Brake voltage reduce 0 0 V
216 AC Brake, Max current 100 100 %
217 Over-voltage Control Disabled Disabled
219 Over-voltage Gain 100 100 %
220 Release Brake Current 0.00 0.00 A
222 Activate Brake Speed [Hz] 0.0 0.0 Hz
223 Activate Brake Delay 0.0 0.0 s

Parameter Group: 3-** Reference / Ramps

ID Name Setup 1 Setup 2 Unit


300 Reference Range -Max - +Max Min - Max
301 Reference/Feedback Unit Hz Hz
302 Minimum Reference 0.000 0.000
303 Maximum Reference 50.000 56.500
304 Reference Function Sum Sum
310.0 Preset Reference 11.00 0.00 %
310.1 Preset Reference 0.00 0.00 %
310.2 Preset Reference 0.00 0.00 %
310.3 Preset Reference 0.00 0.00 %
310.4 Preset Reference 0.00 0.00 %
310.5 Preset Reference 0.00 0.00 %
310.6 Preset Reference 0.00 0.00 %
310.7 Preset Reference 0.00 0.00 %
311 Jog Speed [Hz] 5.0 5.0 Hz
312 Catch up/slow Down Value 0.00 0.00 %
314 Preset Relative Reference 0.00 0.00 %
315 Reference 1 Source No function Analog Input 53
316 Reference 2 Source No function No function
317 Reference 3 Source Local bus reference Local bus reference
318 Relative Scaling Reference Resource
No function No function
340 Ramp 1 Type Linear Linear
341 Ramp 1 Ramp Up Time 10.00 10.00 s
342 Ramp 1 Ramp Down Time 20.00 20.00 s
350 Ramp 2 Type Linear Linear
351 Ramp 2 Ramp Up Time 10.00 10.00 s
352 Ramp 2 Ramp Down Time 20.00 20.00 s
360 Ramp 3 Type Linear Linear
361 Ramp 3 Ramp up Time 10.00 10.00 s
362 Ramp 3 Ramp down Time 20.00 20.00 s
370 Ramp 4 Type Linear Linear
371 Ramp 4 Ramp up Time 10.00 10.00 s
372 Ramp 4 Ramp Down Time 20.00 20.00 s
380 Jog Ramp Time 10.00 10.00 s
381 Quick Stop Ramp Time 10.00 10.00 s
390 Step Size 0.10 0.10 %
392 Power Restore Off Off
393 Maximum Limit 100 100 %
394 Minimum Limit -100 -100 %
395 Ramp Delay 1000 1000 ms

Parameter Group: 4-** Limits / Warnings

ID Name Setup 1 Setup 2 Unit


410 Motor Speed Direction Both directions Both directions
412 Motor Speed Low Limit [Hz] 0.0 5.4 Hz

Page: 3 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

414 Motor Speed High Limit [Hz] 50.0 50.0 Hz


416 Torque Limit Motor Mode 160 160 %
417 Torque Limit Generator Mode100 100 %
418 Current Limit 160 160 %
419 Max Output Frequency 50.0 50.0 Hz
420 Torque Limit Factor Source No function No function
421 Speed Limit Factor Source No function No function
422 Break Away Boost Off Off
430 Motor Feedback Loss FunctionTrip Trip
431 Motor Feedback Speed Error 20 20 Hz
432 Motor Feedback Loss Timeout0.05 0.05 s
440 Warning Freq. Low 0.0 5.4 Hz
441 Warning Freq. High 5.0 5.4 Hz
442 Adjustable Temperature Warning
0 0
450 Warning Current Low 0.00 0.00 A
451 Warning Current High 34.50 34.50 A
454 Warning Reference Low -4,999.000 -4,999.000
455 Warning Reference High 4,999.000 4,999.000
456 Warning Feedback Low -4,999.000 -4,999.000
457 Warning Feedback High 4,999.000 4,999.000
458 Missing Motor Phase FunctionOn On
461.0 Bypass Speed From [Hz] 0.0 0.0 Hz
461.1 Bypass Speed From [Hz] 0.0 0.0 Hz
461.2 Bypass Speed From [Hz] 0.0 0.0 Hz
461.3 Bypass Speed From [Hz] 0.0 0.0 Hz
463.0 Bypass Speed To [Hz] 0.0 0.0 Hz
463.1 Bypass Speed To [Hz] 0.0 0.0 Hz
463.2 Bypass Speed To [Hz] 0.0 0.0 Hz
463.3 Bypass Speed To [Hz] 0.0 0.0 Hz

Parameter Group: 5-** Digital In/Out

ID Name Setup 1 Setup 2 Unit


500 Digital I/O Mode PNP PNP
501 Terminal 27 Mode Input Input
502 Terminal 29 Mode Input Input
510 Terminal 18 Digital Input Start Start
511 Terminal 19 Digital Input Start reversing No operation
512 Terminal 27 Digital Input Set-up select bit 0 Set-up select bit 0
513 Terminal 29 Digital Input No operation No operation
514 Terminal 32 Digital Input Reset Reset
515 Terminal 33 Digital Input No operation No operation
516 Terminal 31 Digital Input External Interlock External Interlock
530 Terminal 27 Digital Output No operation No operation
531 Terminal 29 Digital Output No operation No operation
534 On Delay, Digital Output 0.01 0.01 s
535 Off Delay, Digital Output 0.01 0.01 s
540.0 Function Relay Running Running
540.1 Function Relay Alarm Alarm
541.0 On Delay, Relay 0.01 0.01 s
541.1 On Delay, Relay 0.01 0.01 s
542.0 Off Delay, Relay 0.01 0.01 s
542.1 Off Delay, Relay 0.01 0.01 s
550 Term. 29 Low Frequency 4 4 Hz
551 Term. 29 High Frequency 32000 32000 Hz
552 Term. 29 Low Ref./Feedb. Value
0.000 0.000
553 Term. 29 High Ref./Feedb. Value
50.000 50.000
555 Term. 33 Low Frequency 4 4 Hz
556 Term. 33 High Frequency 32000 32000 Hz
557 Term. 33 Low Ref./Feedb. Value
0.000 0.000
558 Term. 33 High Ref./Feedb. Value
50.000 50.000
560 Terminal 27 Pulse Output Variable
No operation No operation
562 Pulse Output Max Freq 27 5000 5000 Hz

Page: 4 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

563 Terminal 29 Pulse Output Variable


No operation No operation
565 Pulse Output Max Freq 29 5000 5000 Hz
570 Term 32/33 Pulses Per Revolution
1024 1024
571 Term 32/33 Encoder DirectionClockwise Clockwise
590 Digital & Relay Bus Control 0hex 0hex
593 Pulse Out 27 Bus Control 0.00 0.00 %
594 Pulse Out 27 Timeout Preset 0.00 0.00 %
595 Pulse Out 29 Bus Control 0.00 0.00 %
596 Pulse Out 29 Timeout Preset 0.00 0.00 %

Parameter Group: 6-** Analog In/Out

ID Name Setup 1 Setup 2 Unit


600 Live Zero Timeout Time 10 10 s
601 Live Zero Timeout Function Off Off
610 Terminal 53 Low Voltage 0.07 0.07 V
611 Terminal 53 High Voltage 10.00 10.00 V
612 Terminal 53 Low Current 4.00 4.00 mA
613 Terminal 53 High Current 20.00 20.00 mA
614 Terminal 53 Low Ref./Feedb. Value
0.000 0.000
615 Terminal 53 High Ref./Feedb. 50.000
Value 50.000
616 Terminal 53 Filter Time Constant
0.01 0.01 s
619 Terminal 53 mode Current mode Current mode
620 Terminal 54 Low Voltage 0.07 0.07 V
621 Terminal 54 High Voltage 10.00 10.00 V
622 Terminal 54 Low Current 4.00 4.00 mA
623 Terminal 54 High Current 20.00 20.00 mA
624 Terminal 54 Low Ref./Feedb. Value
0.000 0.000
625 Terminal 54 High Ref./Feedb. 50.000
Value 50.000
626 Terminal 54 Filter Time Constant
0.01 0.01 s
629 Terminal 54 mode Voltage mode Voltage mode
670 Terminal 45 Mode 4-20 mA 4-20 mA
671 Terminal 45 Analog Output Motor Current Motor Current
672 Terminal 45 Digital Output No operation No operation
673 Terminal 45 Output Min Scale0.00 0.00 %
674 Terminal 45 Output Max Scale87.00 87.00 %
676 Terminal 45 Output Bus Control
0 0
690 Terminal 42 Mode 4-20 mA 4-20 mA
691 Terminal 42 Analog Output Speed Speed
692 Terminal 42 Digital Output No operation No operation
693 Terminal 42 Output Min Scale0.00 0.00 %
694 Terminal 42 Output Max Scale115.00 115.00 %
696 Terminal 42 Output Bus Control
0 0

Parameter Group: 7-** Controllers

ID Name Setup 1 Setup 2 Unit


700 Speed PID Feedback Source None None
702 Speed PID Proportional Gain 0.015 0.015
703 Speed PID Integral Time 8.0 8.0 ms
704 Speed PID Differentiation Time
30.0 30.0 ms
705 Speed PID Diff. Gain Limit 5.0 5.0
706 Speed PID Lowpass Filter Time10.0 10.0 ms
707 Speed PID Feedback Gear Ratio1.0000 1.0000
708 Speed PID Feed Forward Factor0 0 %
712 Torque PID Proportional Gain100 100 %
713 Torque PID Integration Time 0.020 0.020 s
720 Process CL Feedback 1 Resource
No function No function
722 Process CL Feedback 2 Resource
No function No function
730 Process PID Normal/ Inverse Control
Normal Normal
731 Process PID Anti Windup On On
732 Process PID Start Speed 0 0 rpm

Page: 5 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

733 Process PID Proportional Gain0.01 0.01


734 Process PID Integral Time 9,999.00 9,999.00 s
735 Process PID Differentiation Time
0.00 0.00 s
736 Process PID Diff. Gain Limit 5.0 5.0
738 Process PID Feed Forward Factor
0 0 %
739 On Reference Bandwidth 5 5 %
740 Process PID I-part Reset No No
741 Process PID Output Neg. Clamp -100 -100 %
742 Process PID Output Pos. Clamp 100 100 %
743 Process PID Gain Scale at Min.100
Ref. 100 %
744 Process PID Gain Scale at Max.100Ref. 100 %
745 Process PID Feed Fwd Resource No function No function
746 Process PID Feed Fwd Normal/Normal
Inv. Ctrl. Normal
748 PCD Feed Forward 0 0
749 Process PID Output Normal/ Inv.
Normal
Ctrl. Normal
750 Process PID Extended PID Enabled Enabled
751 Process PID Feed Fwd Gain 1.00 1.00
752 Process PID Feed Fwd Ramp up 0.01 0.01 s
753 Process PID Feed Fwd Ramp down0.01 0.01 s
756 Process PID Ref. Filter Time 0.001 0.001 s
757 Process PID Fb. Filter Time 0.001 0.001 s
760 Feedback 1 Conversion Linear Linear
762 Feedback 2 Conversion Linear Linear

Parameter Group: 8-** Comm. and Options

ID Name Setup 1 Setup 2 Unit


801 Control Site Digital and ctrl.word Digital and ctrl.word
802 Control Source FC Port FC Port
803 Control Timeout Time 1.0 1.0 s
804 Control Timeout Function Off Off
807 Diagnosis Trigger Disable Disable
810 Control Word Profile FC profile FC profile
814.0 Configurable Control Word CTW
Profile default Profile default
814.1 Configurable Control Word CTW
Profile default Profile default
814.2 Configurable Control Word CTW
Profile default Profile default
814.3 Configurable Control Word CTW
Profile default Profile default
814.4 Configurable Control Word CTW
Profile default Profile default
814.5 Configurable Control Word CTW
Profile default Profile default
814.6 Configurable Control Word CTW
Profile default Profile default
814.7 Configurable Control Word CTW
Profile default Profile default
814.8 Configurable Control Word CTW
Profile default Profile default
814.9 Configurable Control Word CTW
Profile default Profile default
814.10 Configurable Control Word CTW
Profile default Profile default
814.11 Configurable Control Word CTW
Profile default Profile default
814.12 Configurable Control Word CTW
Profile default Profile default
814.13 Configurable Control Word CTW
Profile default Profile default
814.14 Configurable Control Word CTW
Profile default Profile default
814.15 Configurable Control Word CTW
Profile default Profile default
819.0 Product Code 0 0
819.1 Product Code 0 0
831 Address 1 1
832 Baud Rate 9600 Baud 9600 Baud
833 Parity / Stop Bits Even Parity, 1 Stop Bit Even Parity, 1 Stop Bit
835 Minimum Response Delay 0.010 0.010 s
836 Maximum Response Delay 5.000 5.000 s
837 Maximum Inter-char delay 0.025 0.025 s
842.0 PCD Write Configuration FC Port CTW FC Port CTW
842.1 PCD Write Configuration FC Port REF FC Port REF
842.2 PCD Write Configuration None None
842.3 PCD Write Configuration None None
842.4 PCD Write Configuration None None
842.5 PCD Write Configuration None None

Page: 6 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

842.6 PCD Write Configuration None None


842.7 PCD Write Configuration None None
842.8 PCD Write Configuration None None
842.9 PCD Write Configuration None None
842.10 PCD Write Configuration None None
842.11 PCD Write Configuration None None
842.12 PCD Write Configuration None None
842.13 PCD Write Configuration None None
842.14 PCD Write Configuration None None
842.15 PCD Write Configuration None None
843.0 PCD Read Configuration [1603] Status Word [1603] Status Word
843.1 PCD Read Configuration [1605] Main Actual Value [%] [1605] Main Actual Value [%]
843.2 PCD Read Configuration None None
843.3 PCD Read Configuration None None
843.4 PCD Read Configuration None None
843.5 PCD Read Configuration None None
843.6 PCD Read Configuration None None
843.7 PCD Read Configuration None None
843.8 PCD Read Configuration None None
843.9 PCD Read Configuration None None
843.10 PCD Read Configuration None None
843.11 PCD Read Configuration None None
843.12 PCD Read Configuration None None
843.13 PCD Read Configuration None None
843.14 PCD Read Configuration None None
843.15 PCD Read Configuration None None
850 Coasting Select Logic OR Logic OR
851 Quick Stop Select Logic OR Logic OR
852 DC Brake Select Logic OR Logic OR
853 Start Select Logic OR Logic OR
854 Reversing Select Logic OR Logic OR
855 Set-up Select Logic OR Logic OR
856 Preset Reference Select Logic OR Logic OR
857 Profidrive OFF2 Select Logic OR Logic OR
858 Profidrive OFF3 Select Logic OR Logic OR
879.0 Protocol Firmware version 0.00 0.00
879.1 Protocol Firmware version 0.00 0.00
879.2 Protocol Firmware version 0.00 0.00
879.3 Protocol Firmware version 0.00 0.00
879.4 Protocol Firmware version 0.00 0.00
880 Bus Message Count 6657 6657
881 Bus Error Count 0 0
882 Slave Messages Rcvd 6534 6534
883 Slave Error Count 104 104
884 Slave Messages Sent 0 0
885 Slave Timeout Errors 0 0
888 Reset FC port Diagnostics Do not reset Do not reset
890 Bus Jog 1 Speed 100 100 rpm
891 Bus Jog 2 Speed 200 200 rpm

Parameter Group: 13-** Smart Logic

ID Name Setup 1 Setup 2 Unit


1300 SL Controller Mode Off Off
1301 Start Event Start command Start command
1302 Stop Event Drive stopped Drive stopped
1303 Reset SLC Do not reset SLC Do not reset SLC
1310.0 Comparator Operand Disabled Disabled
1310.1 Comparator Operand Disabled Disabled
1310.2 Comparator Operand Disabled Disabled
1310.3 Comparator Operand Disabled Disabled
1310.4 Comparator Operand Disabled Disabled
1310.5 Comparator Operand Disabled Disabled

Page: 7 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

1311.0 Comparator Operator Approx.Equal (~) Approx.Equal (~)


1311.1 Comparator Operator Approx.Equal (~) Approx.Equal (~)
1311.2 Comparator Operator Approx.Equal (~) Approx.Equal (~)
1311.3 Comparator Operator Approx.Equal (~) Approx.Equal (~)
1311.4 Comparator Operator Approx.Equal (~) Approx.Equal (~)
1311.5 Comparator Operator Approx.Equal (~) Approx.Equal (~)
1312.0 Comparator Value 0.000 0.000
1312.1 Comparator Value 0.000 0.000
1312.2 Comparator Value 0.000 0.000
1312.3 Comparator Value 0.000 0.000
1312.4 Comparator Value 0.000 0.000
1312.5 Comparator Value 0.000 0.000
1320.0 SL Controller Timer 0.00 0.00 s
1320.1 SL Controller Timer 0.00 0.00 s
1320.2 SL Controller Timer 0.00 0.00 s
1320.3 SL Controller Timer 0.00 0.00 s
1320.4 SL Controller Timer 0.00 0.00 s
1320.5 SL Controller Timer 0.00 0.00 s
1320.6 SL Controller Timer 0.00 0.00 s
1320.7 SL Controller Timer 0.00 0.00 s
1340.0 Logic Rule Boolean 1 False False
1340.1 Logic Rule Boolean 1 False False
1340.2 Logic Rule Boolean 1 False False
1340.3 Logic Rule Boolean 1 False False
1340.4 Logic Rule Boolean 1 False False
1340.5 Logic Rule Boolean 1 False False
1341.0 Logic Rule Operator 1 Disabled Disabled
1341.1 Logic Rule Operator 1 Disabled Disabled
1341.2 Logic Rule Operator 1 Disabled Disabled
1341.3 Logic Rule Operator 1 Disabled Disabled
1341.4 Logic Rule Operator 1 Disabled Disabled
1341.5 Logic Rule Operator 1 Disabled Disabled
1342.0 Logic Rule Boolean 2 False False
1342.1 Logic Rule Boolean 2 False False
1342.2 Logic Rule Boolean 2 False False
1342.3 Logic Rule Boolean 2 False False
1342.4 Logic Rule Boolean 2 False False
1342.5 Logic Rule Boolean 2 False False
1343.0 Logic Rule Operator 2 Disabled Disabled
1343.1 Logic Rule Operator 2 Disabled Disabled
1343.2 Logic Rule Operator 2 Disabled Disabled
1343.3 Logic Rule Operator 2 Disabled Disabled
1343.4 Logic Rule Operator 2 Disabled Disabled
1343.5 Logic Rule Operator 2 Disabled Disabled
1344.0 Logic Rule Boolean 3 False False
1344.1 Logic Rule Boolean 3 False False
1344.2 Logic Rule Boolean 3 False False
1344.3 Logic Rule Boolean 3 False False
1344.4 Logic Rule Boolean 3 False False
1344.5 Logic Rule Boolean 3 False False
1351.0 SL Controller Event False False
1351.1 SL Controller Event False False
1351.2 SL Controller Event False False
1351.3 SL Controller Event False False
1351.4 SL Controller Event False False
1351.5 SL Controller Event False False
1351.6 SL Controller Event False False
1351.7 SL Controller Event False False
1351.8 SL Controller Event False False
1351.9 SL Controller Event False False
1351.10 SL Controller Event False False
1351.11 SL Controller Event False False
1351.12 SL Controller Event False False
1351.13 SL Controller Event False False

Page: 8 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

1351.14 SL Controller Event False False


1351.15 SL Controller Event False False
1351.16 SL Controller Event False False
1351.17 SL Controller Event False False
1351.18 SL Controller Event False False
1351.19 SL Controller Event False False
1352.0 SL Controller Action Disabled Disabled
1352.1 SL Controller Action Disabled Disabled
1352.2 SL Controller Action Disabled Disabled
1352.3 SL Controller Action Disabled Disabled
1352.4 SL Controller Action Disabled Disabled
1352.5 SL Controller Action Disabled Disabled
1352.6 SL Controller Action Disabled Disabled
1352.7 SL Controller Action Disabled Disabled
1352.8 SL Controller Action Disabled Disabled
1352.9 SL Controller Action Disabled Disabled
1352.10 SL Controller Action Disabled Disabled
1352.11 SL Controller Action Disabled Disabled
1352.12 SL Controller Action Disabled Disabled
1352.13 SL Controller Action Disabled Disabled
1352.14 SL Controller Action Disabled Disabled
1352.15 SL Controller Action Disabled Disabled
1352.16 SL Controller Action Disabled Disabled
1352.17 SL Controller Action Disabled Disabled
1352.18 SL Controller Action Disabled Disabled
1352.19 SL Controller Action Disabled Disabled

Parameter Group: 14-** Special Functions

ID Name Setup 1 Setup 2 Unit


1401 Switching Frequency 5.0 kHz 5.0 kHz
1403 Overmodulation On On
1407 Dead Time Compensation Level 100 100
1408 Damping Gain Factor 96 96 %
1409 Dead Time Bias Current Level0 0 %
1410 Mains Failure No function No function
1411 Mains Voltage at Mains Fault 342 342 V
1412 Function at Mains Imbalance Trip Trip
1415 Kin. Backup Trip Recovery Level200.000 200.000
1420 Reset Mode Manual reset Manual reset
1421 Automatic Restart Time 10 10 s
1422 Operation Mode Normal operation Normal operation
1424 Trip Delay at Current Limit 60 60 s
1425 Trip Delay at Torque Limit 60 60 s
1427 Action At Inverter Fault Warning Warning
1430 Current Lim Ctrl, Proportional100
Gain 100 %
1431 Current Lim Ctrl, Integration Time
0.020 0.020 s
1432 Current Lim Ctrl, Filter Time 5.0 5.0 ms
1440 VT Level 66 66 %
1441 AEO Minimum Magnetisation66 66 %
1444 d-axis current optimization for100
IPM 100 %
1450 RFI Filter Grid Type Grid Type
1451 DC-Link Voltage Compensation On On
1452 Fan Control Constant-on mode Constant-on mode
1455 Output Filter No Filter No Filter
1461 Function at Inverter Overload Trip Trip
1463 Min Switch Frequency 2.0 kHz 2.0 kHz
1464 Dead Time Compensation ZeroDisabled
Current Level Disabled
1465 Speed Derate Dead Time Compensation
500 500 Hz
1489 Option Detection Protect Option Config. Protect Option Config.
1490.0 Fault Level Trip Lock Trip Lock
1490.1 Fault Level Trip Lock Trip Lock
1490.2 Fault Level Trip Lock Trip Lock

Page: 9 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

1490.3 Fault Level Trip Lock Trip Lock


1490.4 Fault Level Trip Lock Trip Lock
1490.5 Fault Level Trip Lock Trip Lock
1490.6 Fault Level Trip Lock Trip Lock
1490.7 Fault Level Trip Lock Trip Lock

Parameter Group: 15-** Drive Information

ID Name Setup 1 Setup 2 Unit


1500 Operating hours 0 0 h
1501 Running Hours 0 0 h
1502 kWh Counter 0 0 kWh
1503 Power Up's 7 7
1504 Over Temp's 0 0
1505 Over Volt's 0 0
1506 Reset kWh Counter Do not reset Do not reset
1507 Reset Running Hours CounterDo not reset Do not reset
1530.0 Alarm Log: Error Code 60 60
1530.1 Alarm Log: Error Code 60 60
1530.2 Alarm Log: Error Code 56 56
1530.3 Alarm Log: Error Code 60 60
1530.4 Alarm Log: Error Code 60 60
1530.5 Alarm Log: Error Code 60 60
1530.6 Alarm Log: Error Code 60 60
1530.7 Alarm Log: Error Code 60 60
1530.8 Alarm Log: Error Code 60 60
1530.9 Alarm Log: Error Code 60 60
1531 InternalFaultReason 0 0
1540 FC Type FC-360 FC-360
1541 Power Section H11K: 11.00kW H11K: 11.00kW
1542 Voltage T4: 3x380-480VAC T4: 3x380-480VAC
1543 Software Version 1.60 1.60
1544 Ordered TypeCode FC-360H11KT4E20H2BXCDXXSXXXXAXBX FC-360H11KT4E20H2BXCDXXSXXXXAXBX
1545 Actual Typecode String FC-360H11KT4E20H2BXCDXXSXXXXAXBX FC-360H11KT4E20H2BXCDXXSXXXXAXBX
1546 Drive Ordering No 134F2980 134F2980
1548 LCP Id No LCP -------- v0005 LCP -------- v0005
1549 SW ID Control Card A:2062 M:2065 D:0155 A:2062 M:2065 D:0155
1550 SW ID Power Card SW:2065 EE:0132-0002 SW:2065 EE:0132-0002
1551 Drive Serial Number 421401A376 421401A376
1553 Power Card Serial Number 132B6439 009170L356 132B6439 009170L356
1560.0 Option Mounted A:X No option A:X No option
1560.1 Option Mounted B:X No option B:X No option
1560.2 Option Mounted No option No option
1560.3 Option Mounted No option No option
1560.4 Option Mounted No option No option
1560.5 Option Mounted No option No option
1560.6 Option Mounted No option No option
1560.7 Option Mounted No option No option
1561.0 Option SW Version A:X SW: 00.00 A:X SW: 00.00
1561.1 Option SW Version B:X SW: 00.00 B:X SW: 00.00
1561.2 Option SW Version 00.00 00.00
1561.3 Option SW Version 00.00 00.00
1561.4 Option SW Version 00.00 00.00
1561.5 Option SW Version 00.00 00.00
1561.6 Option SW Version 00.00 00.00
1561.7 Option SW Version 00.00 00.00
1562.0 Option Ordering No No Info No Info
1562.1 Option Ordering No No Info No Info
1562.2 Option Ordering No No Info No Info
1562.3 Option Ordering No No Info No Info
1562.4 Option Ordering No No Info No Info
1562.5 Option Ordering No No Info No Info
1562.6 Option Ordering No No Info No Info

Page: 10 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

1562.7 Option Ordering No No Info No Info


1563.0 Option Serial No No Info No Info
1563.1 Option Serial No No Info No Info
1563.2 Option Serial No No Info No Info
1563.3 Option Serial No No Info No Info
1563.4 Option Serial No No Info No Info
1563.5 Option Serial No No Info No Info
1563.6 Option Serial No No Info No Info
1563.7 Option Serial No No Info No Info
1599.0 Parameter Metadata 12 12
1599.1 Parameter Metadata 1541 1541
1599.2 Parameter Metadata 1545 1545
1599.3 Parameter Metadata 1570 1570
1599.4 Parameter Metadata 1571 1571
1599.5 Parameter Metadata 0 0
1599.6 Parameter Metadata 0 0
1599.7 Parameter Metadata 0 0
1599.8 Parameter Metadata 0 0
1599.9 Parameter Metadata 1543 1543
1599.10 Parameter Metadata 51 51
1599.11 Parameter Metadata 11 11
1599.12 Parameter Metadata 1542 1542
1599.13 Parameter Metadata 1540 1540
1599.14 Parameter Metadata 10 10
1599.15 Parameter Metadata 13 13
1599.16 Parameter Metadata 3 3
1599.17 Parameter Metadata 1553 1553
1599.18 Parameter Metadata 1551 1551
1599.19 Parameter Metadata 831 831
1599.20 Parameter Metadata 832 832
1599.21 Parameter Metadata 918 918
1599.22 Parameter Metadata 1549 1549
1599.23 Parameter Metadata 1560 1560
1599.24 Parameter Metadata 1561 1561
1599.25 Parameter Metadata 2 2
1599.26 Parameter Metadata 0 0
1599.27 Parameter Metadata 0 0
1599.28 Parameter Metadata 60 60
1599.29 Parameter Metadata 61 61
1599.30 Parameter Metadata 1694 1694
1599.31 Parameter Metadata 0 0
1599.32 Parameter Metadata 0 0
1599.33 Parameter Metadata 0 0
1599.34 Parameter Metadata 0 0
1599.35 Parameter Metadata 0 0

Parameter Group: 16-** Data Readouts

ID Name Setup 1 Setup 2 Unit


1600 Control Word 43Chex 43Chex
1601 Reference [Unit] 5.500 5.500
1602 Reference [%] 11.0 11.0 %
1603 Status Word 607hex 607hex
1605 Main Actual Value [%] 0.00 0.00 %
1609 Custom Readout 0.00 0.00
1610 Power [kW] 0.000 0.000 kW
1611 Power [hp] 0.000 0.000 hp
1612 Motor Voltage 0 0 V
1613 Frequency 0.0 0.0 Hz
1614 Motor current 0.00 0.00 A
1615 Frequency [%] 0.0 0.0 %
1616 Torque [Nm] 0.0 0.0 Nm
1618 Motor Thermal 0 0 %

Page: 11 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

1622 Torque [%] 0 0 %


1630 DC Link Voltage 620 620 V
1633 Brake Energy /2 min 0.000 0.000 kW
1634 Heatsink Temp. 20 20 °C
1635 Inverter Thermal 0 0 %
1636 Inv. Nom. Current 23.00 23.00 A
1637 Inv. Max. Current 34.50 34.50 A
1638 SL Controller State 0 0
1639 Control Card Temp. 35 35 °C
1650 External Reference 0.0 0.0 %
1652 Feedback[Unit] 0.000 0.000
1653 Digi Pot Reference 0.00 0.00
1657 Feedback [RPM] 0 0 rpm
1660 Digital Input 0000010000000000bin 0000010000000000bin
1661 Terminal 53 Setting Current mode Current mode
1662 Analog Input 53 4.01 4.01
1663 Terminal 54 Setting Voltage mode Voltage mode
1664 Analog Input AI54 0.01 0.01
1665 Analog Output 42 [mA] 4.00 4.00 mA
1666 Digital Output ____ ____
1667 Pulse Input 29[Hz] 0 0
1668 Pulse Input 33 [Hz] 0 0
1669 Pulse Output 27 [Hz] 0 0
1670 Pulse Output 29 [Hz] 0 0
1671 Relay Output 0hex 0hex
1672 Counter A 0 0
1673 Counter B 0 0
1679 Analog Output AO45 4.00 4.00 mA
1680 Fieldbus CTW 1 0hex 0hex
1682 Fieldbus REF 1 0 0
1684 Comm. Option STW 0hex 0hex
1685 FC Port CTW 1 43Chex 43Chex
1686 FC Port REF 1 0 0
1690 Alarm Word 0hex 0hex
1691 Alarm Word 2 0hex 0hex
1692 Warning Word 0hex 0hex
1693 Warning Word 2 0hex 0hex
1694 Ext. Status Word 0hex 0hex
1695 Ext. Status Word 2 980hex 980hex
1697 Alarm Word 3 0hex 0hex

Parameter Group: 17-** Feedback Options

ID Name Setup 1 Setup 2 Unit


1760 Feedback Direction Clockwise Clockwise
1761 Feedback Signal Monitoring Warning Warning

Parameter Group: 18-** Data Readouts 2

ID Name Setup 1 Setup 2 Unit


1881 Tension PID Output 0.000 0.000 Hz
1882 Center Winder Output 0.000 0.000 Hz
1883 Line Speed 0.000 0.000 Hz
1884 Diameter 0.000 0.000 %
1885 Tapered Tension Set Point 0.0 0.0 %
1886 Tension Feedback 0.0 0.0 %
1890 Process PID Error 0.0 0.0 %
1891 Process PID Output 0.0 0.0 %
1892 Process PID Clamped Output 0.0 0.0 %
1893 Process PID Gain Scaled Output
0.0 0.0 %

Page: 12 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

Parameter Group: 21-** Ext. Closed Loop

ID Name Setup 1 Setup 2 Unit


2109 Extended PID Enable Disabled Disabled
2111 Ext. 1 Minimum Reference 0.000 0.000
2112 Ext. 1 Maximum Reference 100.000 100.000
2113 Ext. 1 Reference Source No function No function
2114 Ext. 1 Feedback Source No function No function
2115 Ext. 1 Setpoint 0.000 0.000
2117 Ext. 1 Reference [Unit] 0.000 0.000
2118 Ext. 1 Feedback [Unit] 0.000 0.000
2119 Ext. 1 Output [%] 0 0 %
2120 Ext. 1 Normal/Inverse ControlNormal Normal
2121 Ext. 1 Proportional Gain 0.01 0.01
2122 Ext. 1 Integral Time 10,000.00 10,000.00 s
2123 Ext. 1 Differentation Time 0.00 0.00 s
2124 Ext. 1 Dif. Gain Limit 5.0 5.0

Parameter Group: 22-** Appl. Functions

ID Name Setup 1 Setup 2 Unit


2202 Sleepmode CL Control Mode Normal Normal
2240 Minimum Run Time 10 10 s
2241 Minimum Sleep Time 10 10 s
2243 Wake-Up Speed [Hz] 5.0 5.0
2244 Wake-Up Ref./FB Diff 10 10 %
2245 Setpoint Boost 0 0 %
2246 Maximum Boost Time 60 60 s
2247 Sleep Speed [Hz] 0.0 0.0
2248 Sleep Delay Time 0 0 s
2249 Wake-Up Delay Time 0 0 s
2260 Broken Belt Function Off Off
2261 Broken Belt Torque 10 10 %
2262 Broken Belt Delay 10 10 s

Parameter Group: 30-** Special Features

ID Name Setup 1 Setup 2 Unit


3020 High Starting Torque Time [s]0.00 0.00 s
3021 High Starting Torque Current [%]
100.0 100.0 %
3022 Locked Rotor Protection Off Off
3023 Locked Rotor Detection Time 0.10
[s] 0.10 s

Parameter Group: 32-** Motion Control Basic Settings

ID Name Setup 1 Setup 2 Unit


3211 User Unit Denominator 1 1
3212 User Unit Numerator 1 1
3267 Max. Tolerated Position Error 2000000 2000000
3280 Maximum Allowed Velocity 1500 1500 rpm
3281 Motion Ctrl Quick Stop Ramp1000 1000 ms

Parameter Group: 33-** Motion Control Adv. Settings

ID Name Setup 1 Setup 2 Unit


3300 Homing Mode Not forced Not forced
3301 Home Offset 0 0
3302 Home Ramp Time 10 10 ms
3303 Homing Velocity 100 100 rpm
3304 Homing Behaviour Reverse no index Reverse no index

Page: 13 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

3341 Negative Software Limit -500000 -500000


3342 Positive Software Limit 500000 500000
3343 Negative Software Limit ActiveInactive Inactive
3344 Positive Software Limit ActiveInactive Inactive
3347 Target Position Window 0 0

Parameter Group: 34-** Motion Control Data Readouts

ID Name Setup 1 Setup 2 Unit


3401 PCD 1 Write For Application 0 0
3402 PCD 2 Write For Application 0 0
3403 PCD 3 Write For Application 0 0
3404 PCD 4 Write For Application 0 0
3405 PCD 5 Write For Application 0 0
3406 PCD 6 Write For Application 0 0
3407 PCD 7 Write For Application 0 0
3408 PCD 8 Write For Application 0 0
3409 PCD 9 Write For Application 0 0
3410 PCD 10 Write For Application0 0
3421 PCD 1 Read For Application 0 0
3422 PCD 2 Read For Application 0 0
3423 PCD 3 Read For Application 0 0
3424 PCD 4 Read For Application 0 0
3425 PCD 5 Read For Application 0 0
3426 PCD 6 Read For Application 0 0
3427 PCD 7 Read For Application 0 0
3428 PCD 8 Read For Application 0 0
3429 PCD 9 Read For Application 0 0
3430 PCD 10 Read For Application0 0
3450 Actual Position 0 0
3456 Track Error 0 0

Parameter Group: 37-** Application Settings

ID Name Setup 1 Setup 2 Unit


3700 Application Mode Drive mode Drive mode
3701 Pos. Feedback Source 24V Encoder 24V Encoder
3702.0 Pos. Target 0 0
3702.1 Pos. Target 0 0
3702.2 Pos. Target 0 0
3702.3 Pos. Target 0 0
3702.4 Pos. Target 0 0
3702.5 Pos. Target 0 0
3702.6 Pos. Target 0 0
3702.7 Pos. Target 0 0
3703.0 Pos. Type Absolute Absolute
3703.1 Pos. Type Absolute Absolute
3703.2 Pos. Type Absolute Absolute
3703.3 Pos. Type Absolute Absolute
3703.4 Pos. Type Absolute Absolute
3703.5 Pos. Type Absolute Absolute
3703.6 Pos. Type Absolute Absolute
3703.7 Pos. Type Absolute Absolute
3704.0 Pos. Velocity 100 100 rpm
3704.1 Pos. Velocity 100 100 rpm
3704.2 Pos. Velocity 100 100 rpm
3704.3 Pos. Velocity 100 100 rpm
3704.4 Pos. Velocity 100 100 rpm
3704.5 Pos. Velocity 100 100 rpm
3704.6 Pos. Velocity 100 100 rpm
3704.7 Pos. Velocity 100 100 rpm
3705.0 Pos. Ramp Up Time 5000 5000 ms

Page: 14 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

3705.1 Pos. Ramp Up Time 5000 5000 ms


3705.2 Pos. Ramp Up Time 5000 5000 ms
3705.3 Pos. Ramp Up Time 5000 5000 ms
3705.4 Pos. Ramp Up Time 5000 5000 ms
3705.5 Pos. Ramp Up Time 5000 5000 ms
3705.6 Pos. Ramp Up Time 5000 5000 ms
3705.7 Pos. Ramp Up Time 5000 5000 ms
3706.0 Pos. Ramp Down Time 5000 5000 ms
3706.1 Pos. Ramp Down Time 5000 5000 ms
3706.2 Pos. Ramp Down Time 5000 5000 ms
3706.3 Pos. Ramp Down Time 5000 5000 ms
3706.4 Pos. Ramp Down Time 5000 5000 ms
3706.5 Pos. Ramp Down Time 5000 5000 ms
3706.6 Pos. Ramp Down Time 5000 5000 ms
3706.7 Pos. Ramp Down Time 5000 5000 ms
3707 Pos. Auto Brake Ctrl Enable Enable
3708 Pos. Hold Delay 0 0 ms
3709 Pos. Coast Delay 200 200 ms
3710 Pos. Brake Delay 200 200 ms
3711 Pos. Brake Wear Limit 0 0
3712 Pos. PID Anti Windup Enable Enable
3713 Pos. PID Output Clamp 1000 1000
3714 Pos. Ctrl. Source DI DI
3715 Pos. Direction Block No Blocking No Blocking
3717 Pos. Ctrl Fault Behaviour Ramp Down&Brake Ramp Down&Brake
3718 Pos. Ctrl Fault Reason No Fault No Fault
3719 Pos. New Index 0 0
3720 Winder Mode Selection Wind Wind
3721 Tension Set Point 0.0 0.0 %
3722 Taper Set Point 0.0 0.0 %
3723 Partial Roll Diameter Value 5.000 5.000 %
3724 Core1 Diameter 5.000 5.000 %
3725 Core2 Diameter 5.000 5.000 %
3726 Winder Jog Speed 0 0 %
3727 TLD Low Limit 0.0 0.0 %
3728 TLD High Limit 0.0 0.0 %
3729 TLD Timer 0.001 0.001 s
3730 TLDOnDelay Enabled Enabled
3731 Diameter Limit Detector 100.000 100.000 %
3732 Initial Diameter MeasurementSet diameter when diameter reset Set diameter when diameter reset
3733 Diameter Measurement Input No Function No Function
3734 Reading at Core 0.00 0.00
3735 Reading at Full Roll 0.00 0.00 V
3736 Tension Set Point Input Par.3721 Par.3721
3737 Taper Set Point Input Par.3722 Par.3722
3738 Tension Feedback Input No Function No Function
3739 Tension Feedback Type Load cell Load cell
3740 Center Winder Cmd Src Parameter 3754~3759 control the functions Parameter 3754~3759 control the functions
3741 Diameter Change Rate 0.001 0.001 %
3742 Tapered Tension Change Rate 0.1 0.1 %
3743 Diameter Calculator Min Speed0 0 %
3744 Line Acceleration Feed Forward
0.000 0.000
3745 Line Speed Source No function No function
3746 Winder Speed Match Scale 1.000 1.000
3747 Tension PID Profile 0.00 0.00 %
3748 Tension PID Proportional Gain0.00 0.00
3749 Tension PID Derivate Time 0.00 0.00 s
3750 Tension PID Integral Time 501.00 501.00 s
3751 Tension PID Out Limit 0.000 0.000 %
3752 Tension PID Der Gain Limit 5.0 5.0
3753 Tension PID Anti Windup Enabled Enabled
3754 Winder Jog Reverse No Function No Function
3755 Winder Jog Forward No function No function
3756 New Diameter Select Core diameter Core diameter

Page: 15 of 16
MCT 10 Set-up Software Project -- coal feeder Saturday, May 06, 2017

3757 Tension On/Off Off Off


3758 Core Select Core1 diameter Core1 diameter
3759 Diameter Reset Off Off

Fault Log :
No Fault Log can be printed out in Basic Version.

Page: 16 of 16

Вам также может понравиться