Static pressure of cold water must not exceed the rating of the class pipe used.
Static pressure of hot water must not exceed 70% of the rating of the pipe used and not exceed a consistent operating
temperature of more than 80 degrees Celsius.
Pipes and fittings must be buried under ground at a minimum depth of 300mm and covered with a bedding , free of
roughage, underneath and on top of not less than 100mm.
Pipes and fittings are not UV stabilized and must not be exposed to direct sunlight. Although not covered by this
guarantee, it is suggested that pipes and fittings be painted (sleeved) if exposed to direct sunlight.
Pipes hanging vertically or horizontally must be fastened with the appropriate holder bats with spacing in accordance
to manufacturers’ specifications.