Академический Документы
Профессиональный Документы
Культура Документы
PARAPET WALL
3 3
DROP CEILING BELOW
A•8 A•8
NEW SKYLIGHT
1 1 Existing Existing
A•8 A•8 RTU 3 RTU 4
Existing
RTU 2
ICP 7.5 TONS
(YEAR 2014)
REMIANS IN PLACE
2 2
A•8 A•8
PARAPET WALL
OPEN TO CONFERENCE
ROOM BELOW
MEZZANINE 2
1 1
A•9 A•9
ACOUSTIC PANEL ALONG OUTER WALL OF EXISTING PARAPET
MEZZANINE - REFER TO SECTION DRAWING
CONSTRUCTION LEGEND:
COPIAGUE, NY 11726
EXISTING CONSTRUCTION TO BE REMOVED (DEMOLITION)
ATTIC AND ROOF PLANS
TITLE
EXISTING FRAME CONSTRUCTION TO REMAIN
REVISIONS
EXISTING MASONRY CONSTRUCTION TO REMAIN
Drawing No.
1'-4 3/4"
4 1/4"
4 1/4"
4 1/4"
4 1/4"
4"
EX. ELEC. CL.
1'-10"
102
JANITOR'S P8 111 112 113
103
4'-6 3/4"
5 1/4"
CLOSET 104 105 106 107A 107B 108 110 OFFICE OFFICE OFFICE
OFFICE 1 REMOVE EXISTING FRAME
OFFICE 2 OFFICE OFFICE PRIVATE PRIVATE OFFICE
TOILET RM. TOILET RM. 109 110 PARTITION, PATCH FLOOR &
CEILING AS NECESSARY
12'-0"
7'-0"
101 FLUSH OFFICE OFFICE
5 1/4"
101 MARBLE
SADDLE 106 107
MEN'S TOILET
14'-8"
13'-0 1/4" 5 1/4" 8'-11 5/8" +/- 5 1/4" 17'-4" 5 1/4" 17'-4" 5 1/4" 14'-4" 5 1/4" 5'-0" 5 1/4" 5'-0" 5 1/4" 14'-4" 5 1/4" 4'-0 1/4"
10'-10"
14'-8"
FLUSH
13'-10"
7'-0" TRANSITION AT
SHOWER
PITCH DOWN
SHOWER 112 113
5 1/4"
P3 3'-4"x4' OPTIONAL BUILT-IN
1'-8" FULL- LINEAR W/ BAR SINK
P5 102 HEIGHT TILE EDGE 109
CONFIRM DOOR
DRAIN
5'-4 3/4"
LOCATION W/ MIKE 111 114
P1 P1 P1
5 1/4"
104
7 1/4"
P3
5 1/4"
105 108 ?
5 1/4"
5 1/4"
J I I I I 114
5'-2"
3 135
5 1/4"
5 1/4"
2'-0"
5 1/4"
A•6 BUILT-IN BASE CAB W/ UNISEX
WOMEN'S TOILET SAMPLE STACKS TOILET
4'-6"
4'-6"
COUNTERTOP, UPPER CAB
3'-8"
ALIGN
WOMEN 103 4'-6" PARTITIONS (TYP.) 119
5 1/4"
115
12'-0"
123
JC 119
5 1/4"
5 1/4"
5 1/4"
5 1/4"
137 136 131 127
4'-6 3/4"
8'-0"
5 1/4"
10'-0"
TOILET OFFICE TOILET
117
5 1/4"
4 1/4" 3'-8" 5 1/4" 8'-11" 5 1/4" 5'-0" 5 1/4" 9'-0" 5 1/4" 29'-0 1/2" 5 1/4" 8'-8 1/8" 5 1/4" 4'-8" 8"
CLOSET
5 1/4"
128 127
7'-0"
OFFICE
5 1/4"
1 F 134 132
TOILET
A•6 OFFICE
P8 STAIR
132 118 OFFICE
9'-9 3/4" +/-
9'-7 5/8"
140 116
138 EMPLOYEE
OFFICE P2 135 128 KITCHEN / BREAK
ROOM
8'-10"
5 1/4"
F 129
J UP 120
OFFICE
BANQUET
13'-4 1/2" 5 1/4" 133
5 1/4"
5 1/4"
MIKE A.
JAIME
125 126
8'-8 1/4"
ALIGN
OFFICE OFFICE
3'-8"
3'-8"
EXISTING WALL
5 1/4"
OFFICE 162
NEW SKYLIGHT ABOVE NEW SKYLIGHT ABOVE 129 REF
A 5 1/4" 10'-10 1/4" 5 1/4" 25'-5" 5 1/4" 10'-5 3/8" 5 1/4" 130
DENISE
PATRINA
OFFICE
7'-3"
157 161
1 WALL OFFICE
A•4 SECTION
130
22'-5 3/8"
L
5 1/4"
1 WALL 134
A•4 SECTION 160
P6 P6 P6
13'-0 1/4" 5 1/4" 5'-0" 5 1/4" 16'-11 1/4" 5 1/4" 13'-2" +/- 5 1/4" 16'-7 3/8" 5 1/4" 4'-8" 154
NEW WALL BASE & STOREFRONT UNDER
7'-3"
2'-0"
A 156
RECEPTION TOILET
FILES FILES OFFICE 159
SEPARATE PERMIT
5 1/4"
HALL 153
148 149 8'-0" 5 1/4" 7'-10 3/4" +/-
4'-6" PARTITIONS (TYP.) 4'-0" PARTITION
5 1/4"
5 1/4"
K 2'-8" 2'-8" EX. WOMENS
TOILET
2
5'-0"
A•6 154
5'-0"
5'-0"
M ALIGN P1 ALIGN ENLARGE ENLARGE WALL ALIGN
J J J J WINDOW J OPENING 156
F
5 1/4"
5 1/4"
5 1/4"
144 141 142 145 146 147 150 151
140 3'-0" HIGH 145 146
BASE OFFICE OFFICE OFFICE OFFICE 152
CONFERENCE 147 158
P2 P1 143 144
OFFICE
B P7 OFFICE OFFICE
1 N
A•7 148 153 149 155 150 152
GLASS
WAITING AREA CONFERENCE ROOM
12'-6 1/4"
21'-7 7/8" 2'-11 1/4" 6'-4" 5 1/4" 8'-8" 5 1/4" 9'-0" 5 1/4" 10'-7 1/2" 5 1/4" 10'-7 1/2" PASS- QUIET ROOM OFFICE
THRU
143
INCREASE HEIGHT OF EXISTING WALL EXIT / 157
OPENING, INSTALL NEW STEEL
LINTEL PER STRUCTURAL DRAWINGS STAFF ENTRY P8 VESTIBULE
C A D E E E REMOVE DOORS, E
REMOVE DOOR, ADD WINDOW? INSTALL WINDOWS
FILL IN PORTIONS OF EXISTING WALL INSTALL WINDOW
OPENINGS W/ 8" BLOCK
MAIN
ENTRANCE
EXPANSION OFFICE SPACE (CURRENTY GYM) EXISTING RENU OFFICES
5,875 S.F. +/- 8,507 S.F. +/-
2 2 3 1
A•8 A•7 A•7 A•8
ARCHITECTURAL FLOOR PLAN 1
SCALE: 3/16" = 1'-0" A•3
MINERAL WOOL (ROXUL) ACOUSTIC BATTS MINERAL WOOL (ROXUL) ACOUSTIC BATTS MINERAL WOOL (ROXUL) ACOUSTIC BATTS 358SW20 GALV. STEEL STUDS @ 16" O.C. PROPOSED MASONRY CONSTRUCTION
5 3/4"
CONTINUOUS GALV. METAL TRACK FASTENED TO SLAB CONTINUOUS GALV. METAL TRACK FASTENED TO SLAB CONTINUOUS GALV. METAL TRACK FASTENED TO SLAB 7 3/4" CONTINUOUS GALV. METAL TRACK CONTINUOUS GALV. METAL TRACK FASTENED TO SLAB CONTINUOUS GALV. METAL TRACK FASTENED TO SLAB CONTINUOUS METAL TRACK TOP & BOTTOM
FASTENED TO SLAB EXISTING CONCRETE CONSTRUCTION TO REMAIN
SEALANT AT JOINT BETWEEN PARTITION AND FLOOR SEALANT AT JOINT BETWEEN PARTITION AND FLOOR 5 1/2" SEALANT AT JOINT BETWEEN PARTITION AND FLOOR 5 3/4" SEALANT AT JOINT BETWEEN PARTITION AND FLOOR SEALANT AT JOINT BETWEEN PARTITION AND FLOOR SEALANT AT JOINT BETWEEN PARTITION AND FLOOR SEALANT AT JOINT BETWEEN PARTITION AND FLOOR
PROPOSED CONCRETE CONSTRUCTION
FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR FINISH FLOOR
STRUCTURAL MEMBER ABOVE Date: 11/27/19
TYPE P-1 TYPE P-2 TYPE P-3 TYPE P-4 TYPE P-5 TYPE P-6 TYPE P-7 TYPE P-8
5-1/4" THICK PARTITION 5-1/2" THICK PARTITION 5-3/4" THICK PARTITION 7-3/4" THICK PARTITION Drawing No.
4-7/8" THICK PARTITION NON-RATED NON-RATED NON-RATED 4-7/8" THICK PARTITION 4-7/8" THICK PARTITION INTERIOR FURRING OVER EXTERIOR MASONRY WALL
NON-RATED
ELECTRIC SERVICE TO BE
RELOCATED
REMOVE EXISTING FRAME
PARTITION, PATCH FLOOR &
CEILING AS NECESSARY
MIKE A.
JAIME
REF
DENISE
PATRINA
NEW CLOSET NEW CLOSET
EXISTING PARTITIONS & WORKSTATIONS
TO BE REMOVED
HALL
2
A•6
1
A•7
2 2 3 1
A•8 A•7 A•7 A•8
DEMOLITION PLAN 1
SCALE: 3/16" = 1'-0" A•2
DEMO PLAN
TITLE
REVISIONS
Drawn by NDL
Project No. 191839
Scale: AS NOTED
Date: 11/27/19
Drawing No.
9'-0"
8'-0"
LOW PARTITIONS
BEYOND
4'-6"
EXISTING SLAB
LINEAR LED PENDANT LIGHTING (TYP.)
SUSPENDED ACOUSTIC PANELS (TYP.)
OFFICE
6'-0"
11'-8"
ENLARGED WALL
OPENING
9'-0"
7'-2"
3'-0"
EXISTING SLAB
VINYL COMPOSITE BASE
2 3 1
A•7 A•7 A•8
SUSPENDED
CEILINGS
COPIAGUE, NY 11726
SECTIONS
TITLE
WALL WALL
OPENING OPENING
REVISIONS
EXISTING SLAB ACOUSTIC WALL BASE CAB &
PANELS COUNTERTOP, UPPER Drawn by NDL
CABS ABOVE Project No. 191839
Scale: AS NOTED
Date: 11/27/19
EXISTING SLAB
1 2 1 3
A•7 A•6 A•6 A•6
LONGITUDINAL SECTION thru CONFERENCE 1
SCALE: 1/4 = 1'-0" A•7
SUSPENDED ACOUSTIC PANELS (TYP.)
ACOUSTIC WALL PANELS LINEAR LED PENDANT LIGHTING (TYP.)
(TYP.)
EXISTING ROOF CONSTRUCTION
SUSPENDED, ARCHED,
ACOUSTIC PANELS FULL-HEIGHT PARTITION BEYOND
2'-8"
DIRECT / INDIRECT LINEAR
LED CENTERED ON
ACOUSTIC PANEL
CONFERENCE HALL
ROOM NEW OFFICE
EXTERIOR STOREFRONT
WINDOWS BEYOND
9'-0"
WALL OPENINGS
7'-0"
EXISTING SLAB
2 CROSS SECTION
A•7 SCALE: 1/4" = 1'-0"
3 1 1
A•6 A•6 A•7
CENTERLINE OF EXISTING
GIRDER
CEILING CONSTRUCTION:
• 10J16 C.J. @ 16" O.C.
• 3/4" USG STRUCTURAL CONCRETE PANEL SUBFLOOR
• 3" ROXUL 'SAFE & SOUND' ACOUSTIC MINERAL WOOL
INSULATION
• SUSPENDED 2'X2' ACOUSTIC CEILING BY ARMSTRONG OR
APPROVED EQUAL — OR —
• 1/2" GYP. BD. TAPED, SPACKLED (2 COATS MIN.), AND PAINTED
OPEN OFFICE AREA
NEW OFFICE NEW OFFICE
EXISTING EXTERIOR WALL
12'-0"
CONSTRUCTION TO REMAIN
11'-8"
9'-6"
9'-5"
9'-5"
9'-0"
9'-0"
SECTIONS
4'-6"
TITLE
REVISIONS
EXISTING SLAB
Drawn by NDL
CROSS SECTION 3 Project No. 191839
Scale: AS NOTED
SCALE: 1/4" = 1'-0" A•7 Date: 11/27/19
Drawing No.
CEILING CONSTRUCTION:
• 10J16 C.J. @ 16" O.C.
• 3/4" USG STRUCTURAL CONCRETE PANEL SUBFLOOR
• 3" ROXUL 'SAFE & SOUND' ACOUSTIC MINERAL WOOL
INSULATION
• SUSPENDED 2'X2' ACOUSTIC CEILING BY ARMSTRONG OR
APPROVED EQUAL — OR —
• 1/2" GYP. BD. TAPED, SPACKLED (2 COATS MIN.), AND PAINTED
HALL
SCOTT'S OFFICE NEW OFFICE
EXISTING EXTERIOR WALL
1/2" GYP. BD. CONSTRUCTION TO REMAIN
CEILING
9'-5"
9'-5"
NEW WALL NEW WALL
9'-0"
9'-0"
OPENING OPENING
7'-2"
EXISTING SLAB
CROSS SECTION 1
SCALE: 1/4" = 1'-0" A•8
1 2 1 3
A•7 A•6 A•6 A•6
SUSPENDED, ARCHED,
ACOUSTIC PANELS
WOMEN'S
LINEAR LED PENDANT KITCHENETTE TOILET MEN'S TOILET
LIGHTING (TYP.)
DIRECT / INDIRECT LINEAR
LED CENTERED ON
ACOUSTIC PANEL
CONFERENCE OFFICE
ROOM
9'-0"
LOGISTICS OFFICE
EXISTING SLAB
EXTERIOR STOREFRONT
WINDOWS BEYOND
2 CROSS SECTION
A•7 SCALE: 1/4" = 1'-0"
SECTIONS
TITLE
REVISIONS
Drawn by NDL
Project No. 191839
Scale: AS NOTED
Date: 11/27/19
Drawing No.
AV
EXISTING CEILING &
1 1 LIGHTING TO REMAIN
9 9
EXIT
1 1 1 1 1 1 1 1
HORIZONTAL VANITY SCONCES 8 6 6 6 6 8
CENTERED OVER LAV.
7 7
8
8
135 8 8
WOMEN'S TOILET 1 EXIT EXIT
EXIT
1 114
EXIT
EXIT
3 3 3
3
UNISEX
10 1 1 SAMPLE STACKS TOILET
EXIT
EXISTING CEILING SYSTEM AND
AV
1 1 LIGHTING TO REMAIN
JC 119
133 159 127
EXIT
AV
1 1 124 123 120
OFFICE EX.
134 OFFICE OFFICE OFFICE TOILET
3 132 3
OFFICE
OFFICE
EXITING
6'-0"
STAIR 118
1 1
3 OFFICE
1 1 3
116
3
SKYLIGHT SKYLIGHT EMPLOYEE
138 3 KITCHEN / BREAK
3'-0"
OFFICE 129 ROOM
AV
1 1 UP
1 OFFICE 1
11
3'-0"
125 126
OFFICE OFFICE
SKYLIGHT SKYLIGHT
139 1 1
3 3
OFFICE 3 3
6'-0"
3 SKYLIGHT SKYLIGHT
130
1 OFFICE 1
157
3
OFFICE
3
1 1
3 3 3 3 3
154
NEW CLOSET NEW CLOSET 155 EX. MENS
10 10 156 TOILET
RECEPTION
OFFICE
DECORATIVE
CEILING BREAK
FIXTURE T.B.D. HALL 153
3 DECORATIVE EX. WOMENS
FIXTURE T.B.D. 1 1
EXISTING CEILING SYSTEM AND TOILET
3 3 3 3
EXIT
10 10 10 LIGHTING TO REMAIN
EXIT
AV EXIT EXIT
1 1 1 1 1 1 1 1
EXIT / 157
4 4 STAFF ENTRY VESTIBULE
EXIT
AV
MAIN
ENTRANCE
1 2'x2' EDGE-LIT LED PANEL LIGHT RAB Lighting: EZPANHE - 2X2 - 23 - Y - /D10 INSTALLED IN OFFICE DROP CEILINGS 8 2" SQUARE RECESSED DIMMABLE LED CONTECH LIGHTING: HOUSING: R2SQRM
WALL WASHER - 41 - 30K - MVD - WW
36" DIA. RING-SHAPED LED DIRECT / XAL: CIRCLE2.5 - PDT - WH - OPOP - 30K
9 INDIRECT PENDANT - C80 - UNV - 101V - 0750LF - SC -
2
2'x2' LED LENSED LAY-IN FIXTURE RAB Lighting: T17 - 2X2 - 40 - N DM-36 IN
TITLE
LED WALL SCONCE SONNEMAN: AILERON 12" LED SCONCE
12
5 4" SUSPENDED LED LINEAR PENDANT RAB Lighting: BOA-8-P-80-D10-40-Y-W
#2700.16 LIGHTING PLAN
DIRECT LIGHTING FIXTURE JUNCTION BOX FOR DECORATIVE
CEILING FIXTURE
REVISIONS
CONTECH LIGHTING: HOUSING: R4SQIC -
4" SQUARE RECESSED DIMMABLE LED
6 4 - 30K - MVD - M
DOWNLIGHT
TRIM: C4322SQ-CLR
LED WALL SCONCE SONNEMAN: STILETTO 32" LED BATH BAR INSTALLED HORIZONTALLY CENTERED
7 #2342.16-DIM OVER LAVS (MEN'S TOILET)
UNDER-CABINET LED STRIP LIGHT
Drawn by NDL
INSTALLED VERTICALLY BETWEEN LAVS Project No. 191839
LED WALL SCONCE SONNEMAN: STILETTO 24" LED BATH BAR Scale: AS NOTED
7A #2340.16-DIM (WOMEN'S TOILET) Date: 11/27/19
Drawing No.