Вы находитесь на странице: 1из 2

Part #: DX004DSLX9KRA1

4 CHANNEL
D-Series Distribution – Corrugated Steel Tape (CST)
Armored Riser Rated Cables

Laser Ultra-Fox™ Fiber Performance Mechanical and Environmental


Fiber Code SLX Inner Cable Entire Cable
Industry Standard Designation Low Water Peak Impact Resistance 1,500 Impacts 20 impacts (EIA-
Single-Mode EIA/TIA-455-25A TIA-455-25A)
ITU-T G.652.D
Crush Resistance 1,800 N/cm 440 N/cm (EIA-
Core/Cladding Diameter (µm) 9/125 TIA/EIA-455-41A TIA-455-25A)
Wavelength (nm) 1310/1550 Flex Resistance 2,000 cycles 25 cycles
Maximum Cabled Attenuation (dB/km) 0.5/0.5 Operating -40°C to +85°C -40°C to +85°C
Temperature
Primary Coating Diameter (µm) 245
Storage Temperature -55°C to +85°C -55°C to +85°C
Secondary Buffer Diameter (µm) 900
Installation -10°C to +60°C -10°C to +60°C
Zero Dispersion Slope (ps/nm2-km) 0.092
Temperature
Proof Test Level (kpsi) 100 (actual temp. of
cable)

Installation and Operating Characteristics Flame Retardancy UL Listed Type UL listed type
OFNR (UL 1666) OFCR (UL 1666)
Inner Cable
Installation Operating Cable Characteristics
Max Tensile Load 1,400 N (310 lbs) 450 N (100 lbs) Inner Cable
Min Bend Radius 8.6 cm (3.4 in) 5.7 cm (2.2 in) Jacket Color Black
Outer Cable Jacket Material Indoor / Outdoor PVC
Installation Operating Buffer Material PVC
Max Tensile Load 1,400 N (310 lbs) 450 N (100 lbs) Cable Weight 31 kg/km (21 lbs/1000')
Min Bend Radius 17.1 cm (6.7 in) 11.4 cm (4.5 in) Cable Diameter 5.7 mm ( 0.22 in)

Outer Cable
Jacket Color Black
Jacket Material Indoor/Outdoor PVC
Cable Weight 131 kg/km (88 lbs/1000')
Cable Diameter 11.4 mm ( 0.45 in)

This specification is valid as of 08/20/19 17:09, however, the specification is subject to change at any time.
4 CHANNEL Standards
D-Series Distribution – Corrugated Steel Tape (CST) Armored
Riser Rated Cables OCC Indoor/Outdoor tight-buffered fiber optic
cables meet the functional requirements of the
Part #: DX004DSLX9KRA1 following standards:
UL 1666
UL 1651
ICEA-S-104-696
TIA-568
TIA-598

Applications
Ideal for installation where direct burial or rodent protection is required
OFCR rated to allow entry into riser spaces in unlimited lengths
Features
The steel armor is easily removed with an internal ripcord, leaving a fully functional intact riser rated inner cable, with original cable
markings for identification
UL listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
UL listed OFCR cables with riser rated outer armor jacket. This feature eliminates the need to splice the outdoor cable to the indoor cable
within 50 feet of the building entrance
Inner tight-buffered cable is suitable for direct field termination with standard optical connectors

This specification is valid as of 08/20/19 17:09, however, the specification is subject to change at any time.

Powered by TCPDF (www.tcpdf.org)