Вы находитесь на странице: 1из 5

DESIGN OF PURLIN:-(AS PER BUILDING) INPUT

G(MAX.)PURLIN&SIDE GRIT) 1.5 M


DESIGN WIND PRESSURE 1000 N/M2
BAY SPACING FRAME C/C= 9800 mm
a. DEAD LOAD
UNIT WT./METER RUN OF SHEETING @0.06KN/M2 0.09 KN/M
UNTI RUN FOR SELF WT.OF PURLIN 0.07 KN/M

TOTAL DEAD LOAD/METER ON EACH PURLIN= 0.16 KN/M

b. IMPOSED LOAD
IMPOSED LOAD INTENSITY ON PURLIN= 0.75 KN/M2
TOTAL IMPOSED LOAD PER METER ON EACH PURLIN= 1.125 KN/M

c. WIND LOAD
MAX. WIND LOAD PER METER ON EACH PURLIN=
0.9
0.2
MAX.W.L. 1.65 KN/M

LOAD COMBINATION I=DEAD LOAD+IMPOSED LOAD


TOTAL LOAD PER METER ON EACH PURLIN= 1.285

LOAD COMBINATION I=DEAD LOAD+WIND LOAD


TOTAL LOAD PER METER ON EACH PURLIN= 1.49 KN/M

CRTITICAL LOAD = 1.49 KN/M

ACCORDING TO STAAD ANALYSIS: INPUT


MAX.SPAN MOMENT= INPUT 5.52 KNM
MAX.NEGATIVE MOMENT NEAR SUPPORT INPUT 5.65 KNM

USE SECTION:-
INPUT
WT./m 5.07 KG/M
AREA 6.46 CM2
Ix 311 cm4
Iy 48.5 cm2
rmin 1.78 cm
Zx 34.6 cm3
Zy 8.22 cm3
Ixy 90.2 cm4
J 0.085 cm4
Cw 2940 cm6
CHECKING THE ABOVE SECTION BASED ON SECTION 9 OF BS:PART 5-1998.
FLANGE WIDTH= 60 MM
THICKNESS= 2 MM
OVERALL DEPTH<100t
180 mm < 200 mm OK

OVERALL WIDTH OF COMPRESSION FLANGE/THK.,B/t<=35


30 < 35 OK

WIDTH OF LIP >B/5


20 mm > 12 mm OK

TOTAL WIDTH OVER BOTH FLANGE > L/60


120 mm > 163.333 mm OK

Zxx PROVIDE > WL/1800 cm3


34.6 cm3 > 41.9767 cm3 OK

W/t= 25 CONSIDERING INSIDE BENDING RADIUS AS 3mm


MINIMUM OVERALL DEPTH REQ. AS PER cl.no.5.2.2.1 OF IS801-1975

2.8XtX 6OFSQRT(W/t)2-281200/FY BUT NOT LESS THAN 4.8t

HERE, Fy= 3450 N/cm2

MINIMUM OVERALL REQ. DEPTH= 1.59976 cm


OR 15.9976 mm < 20mm
4.8t 9.6 mm < 20mm OK

CALCULATION FOR LATERALLY UNBRACED BEAMS


CALCULATION OF EFFECTIVE DESIGN WIDTH OF COMPRESSION ELEMENT AS PER CL.NO.5.2.1.1OFIS801-1975

(W/t)lim=1435/SQRT(f),CONSIDERING f(ACTUAL STRESS IN COMP.ELEMENT)


1200 KG/cm2
,= 41.4
OR W= 82.8 mm >50mm HENCE FULL FLANGE IS EFF.COMPRESSION.
REFERRING TO CL.NO.6.3(b) OF IS801-1975
(L2Ssc/Diyc); WHERE,
L=UNBRACED LENGTH OF OF THE MEMBER = 2 m(CONSIDERING SAG ROD AT 2m SPACIN
Iyc= MOMENT OF INERTIA OF THE COMPRESSION PORTION OF A SECTION ABOUT THE GRAVITY AXIS
OF THE ENTIER SECTION PARELLEL TO WEB =Iy/2= 24.25
Sxc= COMPRESSION SECTION OF MODULUS OF ENTIER SECTION ABOUT MAJOR AXIS, Ix DIVIDE BY
DIST. TO EXTRIM COMPRESSION FIBER =Zxx= 34.6 cm3

d=DEPTH OF SECTION= 180 mm

= 3170.68 --------(i)

(0.18*3.14^2*Ecb)/Fy= 1028.83 --------(ii)


(0.90*3.14^2*Ecb)/Fy= 5144.14 --------(iii)

(i)>(ii)
<(iii)
HENCE,
Fb=(2FY/3)-(FY2/2.7*3.14^2ECb)*(L2Sxc/dIyc) =
Fb= 1591.18 KG/cm2
= 159.118 N/mm2
REFRING CL.NO.6.1OF IS:801-1975
F(BASIC DESIGN STRESS)=0.6Fy 2070 KG/cm2
= 207 N/mm2
HENCE, Fb= 159.118 N/mm2 IS THE GOVERNING VALUE, SINCE HERE WIND CONDITION IS
Fb= PERM. 211.627 N/mm2
Fb ACTUAL= 163.295 N/mm2 < 211.627 N/mm2 HENCE OK.

CHECK FOR DEFLECTION:-


PERMISIBLE DEFLECTION FOR IMPOSED LOAD ON PURLIN AS MBMA =
SPAN/240= 40.8333 mm
LOAD DUE TO IMPOSED
LOAD ONLY 1.125 KN/M = 11.025 KN

DEFLECTION ACTUAL=3WL3/384EI
= 130.334 mm < 25 mm, FAIL

CALCULATION FOR SHEAR STRESS IN WEB:-


REFRRING TO CL.NO. 6.4 OF IS:801-1975
h = 170 mm
h/t = 85 mm
4590/SQRT(Fy)= 78.1453 < 85 mm HENCE

MAX. AVERAGE PERM. SHEAR STRESS, Fv= 5850000/(h/t)2


= 809.689 Kg/cm2
= 80.9689 N/mm2
ACTUAL SHEAR STRESS= 21.4735 N/mm2 < 107.689 N/mm2

CHECK FOR COMBINED SHEAR AND BENDING IN WEB:-


REFRRING TO CL.NO. 6.4.2 AND 6.4.3 OF IS:801-1975
Fbw=36560000/(h/t)2 = 5060.21 Kg/cm2
= 506.021 N/mm2
F = 2070 Kg/cm2
= 207 N/mm2 HENCE IT IS GOVERNIG VALUE.
SQRT(fbw/Fbw)2 + SQRT(fv/Fv)2 <= 1

= 0.97102 < 1 HENCE OK.


R CL.NO.5.2.1.1OFIS801-1975

E IS EFF.COMPRESSION.

DERING SAG ROD AT 2m SPACING)


TION ABOUT THE GRAVITY AXIS
cm4
T MAJOR AXIS, Ix DIVIDE BY
NCE HERE WIND CONDITION IS CRITICAL,

HENCE OK.

mm, FAIL

RNIG VALUE.