User’s Manual of AL8010F


6. Interface & Operation
6.1. Front Panel & Icon
Heating or Cooling Controller (TC1-1412-1006) Under normal status
 When screen light, Press and hold on
1. Features 3s to turn off the display, attention it is turn
 Within adjustable Aim Temperature Value, Temp. Difference Value, Compressor Delay off controller not just dim the screen;
Time and calibration value; Higher and Lower temperature limit exceed which range will
 When screen dark, Press and release, to
trigger alarms.
light on the screen.
 It will change the room temperature by turn on / off the load automatically.
 Auto memory exist data if electric off, need not to configure it again once power back. Indicator / Character in Display
 With 0.1°C precision and ±1.0°C accuracy; Indicator Meaning On Hide Wink
 The voltage of input electric for the load need not to same as the voltage of this controller Working status of load Load Working Stop Delay
and it is also working if they are same.
Setting status On Set Non-setting N/A
 The output relay for load max bear 30A current under 220V, allow 6600W load.
6.2. Dimensions & Installation
2. Application
Suit to place where need constant temperature, like beer fermentation chamber / pool, brewing
hardware, boiler, fridge, freezer, Incubators, Aquariums, Hatchers, terrariums etc.

3. Package
Controller 1PCS
Fasteners 2PCS
Sensor 1PCS A. Suggested amount dimension: 71.0*29.0*85.0mm (W*H*D)
Manual 1PCS
Waterproof Cover 1PCS B. Detach the slide fasteners, put the controller into the hole, wiring follow diagram;
C. Install the fasteners, and the waterproof cover.
4. Specification D. Please avoid installing in the below environments:
Input Power 220V AC ± 10% 50/60HZ; (12V/24/110V Option)
Maximum current 10A (Default) under 220V AC  Relative humidity > 90%, have condensation
Sensor NTC, 25°C /10 KΩ, sensor cable 200cm
Protection Class IP65 to front panel  The places that temperature <-10°C or >60°C;
Storage -10°C ~ 60°C, RH<90%, without condensation  The places that have inflammables and explosives;
Meas. & Control: -50°C ~ +120°C
Precision: 0.1°C  Strong vibration or struck
Accuracy: ± 1°C  Exposed to the continuous water mist spraying;
Rated Power: ≤ 3W
 Exposed to the dust;
5. Environmental Information  Exposure to corrosive and pollution gas (for example: The gas, smoke or salt
Package: The packages material is 100% recyclable; Just dispose it through fog that contain sulfur or ammonia;
specialized recyclers.
Product: The electro components can be recycled or reused if it is disassembled  Wireless electromagnetic interference or strong magnetic fields (near to
for specialized companies.
transmitting antenna or switch board room);
Disposal: Please do not burn or throw the controllers in domestic garbage, observe
the respectively law in your region concerning the environmental
responsible manner of dispose its devices.

1/2
www.thermo-hygro.com

6.3. Wiring Diagram 7.3. When will the load working?


Firstly of all, the instant time passed the delay time (PT), and then matches one of the following
A. In heating mode (HC = C), the relay will turn on heater when
Measured Temperature Value ≤ ATV - Temp. Differential (D)
B. In cooling mode (HC = H), the relay will turn on cooler
Measured Temperature Value ≥ ATV + Temp. Differential (D)
7.4. How to correct measured temperature if found it not right?
Exist gap/distance between the measured temperature and the real temperature is normal
especially the first time launch this controller; the gaps could be corrected by setting the value in
A. 10K NTC sensor, Need not to distinguish + or - when wiring it.
CA, and please follows the formula: CA = Real Temperature-Measured Temperature.
B. The input voltage must within the voltage value marked in diagram ±10% value.
Voltage of load ∗ Max current of Relay 7.5. How to set other parameters?
C. Load Power ≤
Factor Step1 Press and hold on until appears the code HC (nearly 3s).
 The factor for Inductive Load like compressor, heating pump, usually be 5~8; Step2 Now press the or keys to select the code you want to update;
 The factor for Resistive Load like Electric heating rod, Electric blanket Step3 Press and release to see exist value; then press the or to get your aim value;
usually is 1.5~2; Step4 Press key to memorize the configured value and return to the menu.
 The factor for Incandescent lamp usually is 15.
Repeat operation from Step 2 / 3 / 4 to adjust other parameters;
7. Configurations Step5 Press to save data and quit from setting mode back to normal monitor status. r let it
alone, the modified value will be saved automatically if without operation in 10s
7.1. Code and Function Menu
Code Function Min Max Default Step 7.6. How to get Factory Reset?
In normal status, press and keys in same time, do not release them until screen shows
HC Heating or Cooling C H C
YS which means success, nearly 3s.
D Return Difference (°C) 1 15 5 1
LS Lowest set Limit (°C) -50 ATV -50 1 8. Error & Alarm
When alarm occur, if the readout flash --- and buzzer sounds,
HS Highest Limit (°C) ATV 120 120 1 A. Press any key to stop buzz scream;
CA Temperature Calibration (°C) -5 +5 0 1 B. Check the room temperature and then change the compressor / heater working
PT Delay Time (Min) 0 10 1 1 status manually if necessary,
C. fix or replace the sensor; after that screen will back to normal state
7.2. What is ATV and how to set it? D. And other code please, reference below content to fix problem.
ATV means Aim Temperature Value which is the ideal temperature you wish to reach, Code Reason Troubleshooting
once exceed this value (if difference value = 0) the status of load will be changed,
Details of setting as follow HHH Measured temperature > HS Check the room temperature and then change the
compressor / heater working status manually if
Step1 Assure power on, Press and release key once times you will find display LLL Measured temperature < LS necessary.
blink a data which is changeable.
Step2 Now press the or keys to get you aim value;
 press and hold on the or is fast forward function;
 the steps length is 0.1°C;
 The editable range between lower (LS) and higher (HS) limit.
 The buzzer will scream once Room Temperature < LS, or Room XUZHOU HASWILL ELECTRONICS CO., LTD.
Temperature > HS, Press any key to stop screaming if you want to. www.thermo-hygro.com ; tech@thermo-hygro.com
Step3 Waiting for 10s the device will save data automatically or press to save it. Copyright 2016 Haswill-Haswell All Rights Reserved