Вы находитесь на странице: 1из 98

Installation, Operation, &

Maintenance Manual

DG-12 DEGASSER

RIG/PLANT REFERENCE REFERENCE DESCRIPTION


QGP Goldstar (DSS-38) S1100443 Mud Equipment
ADDITIONAL CODE SDRL CODE TOTAL PGS
98 This document contains proprietary and confidential National Oilwell Brandt
information which belongs to National Oilwell Varco; it is 2800 N. Frazier
REMARKS loaned for limited purposes only and remains the property
of National Oilwell Varco. Reproduction, in whole or in Conroe, TX 77303
MAIN TAG NUMBER DISCIPLINE part; or use of this design or distribution of this information
to others is not permitted without the express written
consent of National Oilwell Varco. This document is to be
CLIENT PO NUMBER returned to National Oilwell Varco upon request and in Phone 936-756-4800
any event upon completion of the use for which it was Fax 936-788-7367
loaned.
© Copyright National Oilwell Varco - 2006

CLIENT DOCUMENT NUMBER DOCUMENT NUMBER REV

BC-GOLDSTAR-06-005 02

www.nov.com
REVISION HISTORY

02 08.10.2008 Reissed for information GMJ GMJ JP


01 08.11.2007 For Information GMJ DAR JP
Rev Date (dd.mm.yyyy) Reason for issue Prepared Checked Approved

CHANGE DESCRIPTION

Revision Change description


01 For Information
02 Updated manual and Ingersoll Rand Manual included

www.nov.com
DG Series Degassers
DG-5, DG-10, DG-12 & Dual Models
Installation, Operation and Maintenance
Manual

REFERENCE REFERENCE DESCRIPTION

This document contains proprietary and confidential information which NOV Brandt
belongs to National-Oilwell Varco, L.P., its affiliates or subsidiaries (all
collectively referred to hereinafter as "NOV"). It is loaned for limited P.O. Box 2327
purposes only and remains the property of NOV. Reproduction, in whole Conroe, TX 77305-2327
or in part, or use of this design or distribution of this information to others
is not permitted without the express written consent of NOV. This
2800 N. Frazier Street
document is to be returned to NOV upon request and in any event upon Conroe, TX 77303
completion of the use for which it was loaned. This document and the Phone: 936-756-4800
information contained and represented herein is the copyrighted property
of NOV. Fax: 936-523-2788
© National Oilwell Varco
DOCUMENT NUMBER REV

M9251 4

www.nov.com/brandt
Document number M9251
Revision 4
Page 1 of 54

Revision History

4 26.03.2008 13816 JPW JMJ FM


3 15.02.2008 13752 JPW JMJ FM
2 05.03.2001 12153 SS JPW GS
1 04.12.1998 10959 OJM JPW GS
0 01.12.1998 Initial Release SS JPW GS
Rev Date ECN Number Prepared Checked Approved

www.nov.com/brandt
Document number M9251
Revision 4
Page 3 of 54

Table of Contents
Chapter 1: General Information
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Notes, Cautions, and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Personnel Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
General System Safety Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Replacing Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Proper Use of Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Chapter 2: Product Information


Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Available models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Chapter 3: Installation
Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Vacuum pump motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Jet pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Commissioning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Chapter 4: Operation
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Chapter 5: Troubleshooting
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Chapter 6: Maintenance & Repair


Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Routine maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Daily . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Periodically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Weekly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
500 hours of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
1000 hours of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Jet Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Replacing components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Motor replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

www.nov.com/brandt
Document number M9251
Revision 4
Page 4 of 54

Table of Contents
Vacuum Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Vacuum gauge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Torque values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Chapter 7: Parts and Drawings


Parts identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Ordering replacement parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
One-year recommended spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
DG-10 assembly A611 rev. 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
DG-10 internal subassembly SA564 rev. 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
JP-10 jet pump A988 rev. 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
DG-5 degasser assembly A747 rev. 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
DG-5 internal subassembly SA487 rev. 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
JP-5 jet pump A1000 rev. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
DG-10 w/ Dual Vacuum Pump Assembly A20510 rev. 0. . . . . . . . . . . . . . . . . . . . . . . . . .44
Supporting Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
D255 Ingersol Rand Vacuum Pump Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

Chapter 8: Worldwide Locations


Corporate offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
United States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51

Index

www.nov.com/brandt
Document number M9251
Revision 4
Page 5 of 54

General Information

This manual contains installation, operation, maintenance and parts information. Information in this
manual should enable qualified personnel to install, operate and troubleshoot this system. Every
effort has been made to ensure the accuracy of the information contained herein. NOV Brandt will
not be held liable for errors in this material, or for consequences arising from misuse of this
material.

Conventions
Notes, Cautions, and War nings
Notes, cautions, and warnings provide readers with additional information and advise the reader to
take specific action to protect personnel from potential injury or lethal conditions. They may also
inform the reader of actions necessary to prevent equipment damage. Please pay close attention
to these advisories

Note: The note symbol indicates that additional information is provided about the
current topics.

Caution: The caution symbol indicates that potential damage to equipment or injury to
personnel exists. Follow instructions explicitly. Extreme care should be taken
when performing operations or procedures preceded by this caution symbol.
Warning: The warning symbol indicates a definite risk of equipment damage or
danger to personnel. Failure to observe and follow proper procedures
could result in serious or fatal injury to personnel, significant property
loss, or significant equipment damage.
ESD The ESD (Electrostatic Discharge) warning symbol indicates that static
Warning: control precautions are needed.

Illustrations
Illustrations (figures) provide a graphical representation of equipment components or screen
snapshots for use in identifying parts or establishing nomenclature, and may or may not be drawn
to scale.
For component information specific to your application, see the technical drawings included with
your NOV Brandt documentation.

www.nov.com/brandt
Document number M9251
Revision 4 1: General Information
Page 6 of 54

Safety Requirements
NOV Brandt equipment is installed and operated in a controlled drilling rig environment involving
hazardous situations. Proper maintenance is important for safe and reliable operation. Procedures
outlined in NOV Brandt manuals are the recommended methods of performing operations and
maintenance.

To avoid injury to personnel or equipment damage, carefully observe requirements outlined


in this section.

Personnel Training
All personnel performing installation, operations, repair, or maintenance procedures on the
equipment, or those in the vicinity of the equipment, should be trained on rig safety, tool operation,
and maintenance to ensure their safety.

Personnel should wear protective gear during installation, maintenance, and certain
operations.

Recommended Tools
Service operations may require the use of tools designed specifically for the purpose described.
NOV Brandt recommends that only those tools specified be used when stated. Ensure that
personnel and equipment safety are not jeopardized when following service procedures or using
tools not specifically recommended by NOV Brandt.

General System Safety Practices


The equipment discussed in this manual may require or contain one or more utilities, such as
electrical, hydraulic, pneumatic, or cooling water.

Read and follow the guidelines below before installing equipment or performing
maintenance to avoid endangering exposed persons or damaging equipment.

‰ Isolate energy sources before beginning work.


‰ Avoid performing maintenance or repairs while the equipment is in operation.
‰ Wear proper protective equipment during equipment installation, maintenance, or repair.
Replacing Components
‰ Verify that all components (such as cables, hoses, etc.) are tagged and labeled during
assembly and disassembly of equipment to ensure correct installment.
‰ Replace failed or damaged components with genuine NOV Brandt parts. Failure to do so
could result in equipment damage or injury to personnel.

www.nov.com/brandt
Document number M9251
1: General Information
Revision 4
Page 7 of 54

Routine Maintenance
Equipment must be maintained on a routine basis. See the service manual for maintenance
recommendations.

Failure to conduct routine maintenance could result in equipment damage or injury to


personnel.

Proper Use of Equipment


NOV Brandt equipment is designed for specific functions and applications, and should be used
only for its intended purpose.

Warranty
NOV Brandt warrants that, for a period of one year from the date of delivery equipment of NOV
Brandt manufacture, the Equipment shall be free of defects in materials and workmanship under
normal use and service, and provided the Equipment is used and maintained in accordance with
instructions supplied by NOV Brandt. This is NOV Brandt's sole and exclusive warranty. If a
defect in the Equipment appears within one year from the date of shipment, and Purchaser has
given written notice of such defect within thirty days from the discovery thereof, NOV Brandt will
repair or replace the part, at its option, by shipping a similar part FOB shipping point or, at its
option, refund an equitable portion of the purchase price. NOV Brandt may require the return, to a
designated NOV Brandt location, of the defective part, transportation prepaid to establish
Purchaser's claim.
No allowance will be made for repairs undertaken without NOV Brandt's written consent or
approval.
This warranty applies only to equipment manufactured by NOV Brandt. Warranties on equipment
manufactured by others, if any, are assigned to Purchaser by NOV Brandt (without recourse) at
time of delivery. Any description of Equipment, drawings, specifications, and any samples,
models, bulletins, or similar material, used in connection with this sale are for the sole purpose of
identifying the Equipment and are not to be construed as an express warranty that the Equipment
will conform to such description. Any field advisory or installation support is advisory only. The
foregoing warranties are in lieu of all other warranties, whether oral, written, express, implied or
statutory. Implied warranties or merchantability and fitness for a particular purpose will not apply.
NOV Brandt's warranty obligations and purchaser's remedies thereunder are solely and
exclusively as stated herein. Purchaser's sole and exclusive remedy, whether based upon
warranty, contract or tort, including negligence, will be to proceed under this warranty.
All liability of NOV Brandt shall terminate one year from the date of delivery of the Equipment.

www.nov.com/brandt
Document number M9251
Revision 4 1: General Information
Page 8 of 54

www.nov.com/brandt
Document number M9251
Revision 4
Page 9 of 54

Product Information

Overview
NOV Brandt DG Series Degassers are used to remove entrained gases from dilling muds. The
units are reliable, easy to operate and maintain.
The degasser system consists of a tank containing fiberglass leaves, a vacuum pump and a jet
pump fed by a centrifugal pump.
DG Series Degassers use three principles to remove gas from mud:
‰ Vacuum: reduced internal pressure enlarges the gas bubbles in the mud, allowing them to
escape the mud more easily.
‰ Flow: flowing the mud in thin sheets increases the turbulence, bringing the gas bubbles to
the surface to escape the mud.
‰ Velocity: the velocity at which the mud strikes the leaves and the sides of the tank
encourages any remaining entrained gas to escape.
DG Series Degassers are designed for minimal maintenance. Interior parts are corrosion resistant
and the level float is made of stainless steel.

www.nov.com/brandt
Document number M9251
Revision 4 2: Product Information
Page 10 of 54

Available models
DG Series Degassers are available in three sizes:
‰ DG-5 for flow rates up to 500 gpm.
‰ DG-10 for flow rates up to 1000 gpm.
‰ DG-12 for flow rates up to 1200 gpm.
Some units come with two vacuum pumps.

High temperature leafs are available for operating temperatures above 140oF (60oC).

Specifications

DG-5 DG-10 DG-12

Standard Metric Standard Metric Standard Metric

Flow rate 500 gpm 1893 lpm 1000 gpm 3785 lpm 1200 gpm 4542 lpm

Leaf area 5688 in2 36,697 cm2 17,262 in2 111,367 cm2 17262 in2 111,367 cm2

Width 88 in 2235 mm 100 in 2540 mm 100 in 2540 mm

Length 54 in 1372 mm 60 in 1524 mm 60 in 1524 mm

Height 62 in 1575 mm 77 in 1956 mm 77 in 1956 mm

Weight 2390 lb 1084 kg 3160 lb 1433 kg 3160 lb 1433 kg

‰ Minimum operating temperature . . . . . . . . -20oF / -29oC

Specifications are subject to change without prior notice.

10

www.nov.com/brandt
Document number M9251
Revision 4
Page 11 of 54

Installation

Placement
Place the DG Series Degasser directly downstream from any shale shakers and upstream from
any secondary separation equipment such as desanders, desilters, mud cleaners or centrifuges.

≤ 5 ft.

The gas-cut mud is pulled into the degasser by suction from the vacuum pump.

To ensure proper operation of the degasser, the height from the top of the mud level in
the suction compartment to the inlet of the degasser should not exceed 5 ft (1.52 m).

Place the degasser suction line in the compartment downstream of the sand trap with the end of
the suction line two to three feet from the bottom of the suction compartment. Run the discharge
from the degasser level or with a slight downward slope to the jet pump.
Locate the jet pump in the compartment downstream from the degasser suction. The jet pump is
fed by a centrifugal pump drawing suction from the same tank into which the jet pump discharges.
Submerge the mud discharge line one to two feet below the minimum mud level to ensure proper
operation. The maximum horizontal pipe run between the degasser vessel and jet pump is
20 ft (6.1 m).

Avoid all unnecessary turns and bends in mud lines.

The gas discharge piping from the vacuum pump to waste (or flare, if used) must be adequately
supported to prevent damage to the cast vacuum pump exhaust manifold.
Underflow, or low equalizer lines, are preferred in all agitated compartments except the sand trap
and degasser compartment.
Contact your local NOV Brandt representative or check your agitator’s Installation, Operation, and
Maintenance Manual for proper agitator sizing and installation.

www.nov.com/brandt
Document number M9251
Revision 4 3: Installation
Page 12 of 54

Electrical connections
Vacuum pump motor
The vacuum pump has a 5 Hp (4 kW) 3 phase explosion-proof motor available for operation on
several different voltages and frequencies. Contact your nearest NOV Brandt representative for
available voltages and frequencies.
Before operating the degasser check that the adjustable overload trip setting on the motor starter
is set to the correct amperage. The trip setting should be the same as the Full Load Amp (FLA)
value shown on the motor nameplate.
Available Starters and Overloads
Overload trip setting range
Starter part number b Overload part number
(amps) a

3.5-5.0 14672 24SV

4.5-6.3 14673 24SW

6.5-8.0 14674 24SX

7.0-10.0 14675 24SY

9.0-12.0 14676 24SZ

11.0-16.0 14677 24TA

14.0-20.0 1480944 24VK

17.0-22.0 18849 24VE

a. Full load Amp (FLA) rating of motor should be between min. and max. trip setting range
of overload. If motor FLA is not available when ordering give motor Hp or kW rating, op-
erating voltage and frequency.
b. Starter includes overload and enclosure. Enclosure is NEMA 3,4,7, & 9 rated.

The motor sheave rotates counterclockwise viewed from the motor shaft end. If it is necessary to
reverse the direction of rotation, switch any two wires on the terminal side of the starter switch.

Jet pump
The jet pump is fed by a centrifugal pump sized to provide 75 ft. of head at the jet pump inlet for
the DG-5 and DG-10 models, 100 ft. of head for the DG-12 model. Due to differences in piping
design from one rig to another, the pump size, impeller and horsepower requirements may vary.
Check for proper wiring and setting of the adjustable overload trip setting on the pump motor
starter.
The centrifugal pump should rotate clockwise if the discharge is on your left, counterclockwise if
the discharge is on your right (see arrow on pump casing). If it is necessary to reverse direction of
rotation, switch any two wires on the terminal side of the starter switch.

14

www.nov.com/brandt
Document number M9251
3: Installation
Revision 4
Page 13 of 54

Commissioning procedure
Install the DG Series Degasser according to the specifications contained in this manual and the
following installation and commissioning checklist.
Installation and commissioning checklist
Item Y N

Is the mud suction pipe ≤ 5 ft? Y N

Is the end of the suction line 2 to 3 ft from bottom of suction


Y N
compartment?

Is the mud discharge pipe (from degasser to jet pump) ≤ 20 ft? Y N

Is the discharge from degasser run level or with slight downward slope to
Y N
jet pump?

Is the jet pump downstream from degasser and fed by a centrifugal pump
Y N
drawing suction from same tank as the jet pump is discharging?

Is the mud discharge line submerged 1 to 2 ft below minimum mud level? Y N

Is the vacuum pump motor wired correctly? Y N

Record the amps from the motor nameplate:

Is the starter overload trip setting correct? Y N

Is the vacuum pump oil level correct? Y N

Does the vacuum pump motor sheave rotate counterclockwise (facing


Y N
the motor shaft end)?

Does the centrifugal pump for the jet pump rotate clockwise if the
discharge is on your left, counterclockwise if the discharge is on your Y N
right ? See arrow on pump casing.

Is the vacuum gage installed? Y N

After running 15 minutes

Are the amps read ≤ the recorded motor nameplate amps? Y N

Does the float valve operate freely? Y N

Is the vacuum between 15 and 24 in. Hg.? Y N

www.nov.com/brandt
Document number M9251
Revision 4 3: Installation
Page 14 of 54

14

www.nov.com/brandt
Document number M9251
Revision 4
Page 15 of 54

Operation

Operation
1. Turn vacuum pump on.
The vacuum created inside the vessel draws the fluid into the degasser just as a person
draws soda into their mouth through a straw.
The level in the vessel rises until the float valve depresses the three-way valve, and the
vacuum pump draws suction from the atmosphere rather than the vessel.
At this point, the vacuum in the degasser is just holding the fluid in the unit.
2. Open the centrifugal pump suction valve, close the pump discharge valve and start the
pump.
3. Slowly open the centrifugal pump discharge valve until it is fully open.
This supplies the needed pressure to the jet pump and pulls the degassed mud from the
unit.

Note: On units supplied with two (2) vacuum pumps, make sure that one of the pumps is
isolated before turning on the other pump. Operating the degasser with both vacuum
pumps will not lead to improved performance. Refer to drawing titled "DG-10 w/ Dual
Vacuum Pump Assembly A20510 rev. 0" on page 44 for the vacuum pump flow diagram.

www.nov.com/brandt
Document number M9251
Revision 4 4: Operation
Page 16 of 54

16

www.nov.com/brandt
Document number M9251
Revision 4
Page 17 of 54

Troubleshooting

Troubleshooting
Symptom Probable cause Action

Inadequate vacuum Leak of vacuum to atmosphere. Check and tighten all connections
indicated on gauge. to degasser body and piping to
vacuum pump.

Look for pinholes in piping.

Three-way air valve drawing Drain liquid trap.


from atmosphere only.
Lubricate valve.

Check float assembly.

Faulty gauge. Replace gauge.

Drawing air from secondary Check that secondary pump is


vacuum pump, if equipped. isolated when not in use.

Centrifugal pump not Worn out impeller. Replace impeller.


operating efficiently.
Worn out wear plate. Replace wear plate.

Worn out housing. Replace housing.

Centrifugal pump sucks air. Packing not tight. Repack or replace with mechanical
seal.

Vacuum pump does not run Overload trip setting incorrect. Check overload trip setting.
continuously.
Motor single phasing. Check phase to phase voltages.
Voltages should be at motor rated
voltage 5%. If not, find cause of
single phasing and correct.

Voltage or cycle fluctuations. Check electrical service.

Motor overloaded. Check amps on each phase. Amps


should be less than FLA on motor. If
not, remove belt from motor to
vacuum pump. Check for free
rotation of vacuum pump.

www.nov.com/brandt
Document number M9251
Revision 4 5: Troubleshooting
Page 18 of 54

Symptom Probable cause Action

Vacuum pump motor does Main power not present on line Turn main power on. Check wiring
not run. side of starter. to starter.

Manual starter not engaged. Turn starter on. Make sure handle
on outside of enclosure properly
engages switch on inside of
enclosure.

No power at terminal side of Replace starter overload. See table


starter. titled "Available Starters and
Overloads" on page 12.

Wires damaged between starter Check and repair wiring as


and motor. required. Check wiring connections
inside motor junction box.

Vacuum pump locked up. Remove belts from motor to


vacuum pump. Check for free
rotation of vacuum pump. Replace
or repair vacuum pump.

No mud flowing from Vacuum pump not running. Check vacuum pump and motor.
degasser.
Centrifugal pump not running. Check centrifugal pump and motor.

Float valve assembly not working Check floats and valve assembly.
properly.

Buildup in liquid trap. Empty and clean liquid trap.

Buildup in vessel. Clean vessel by running water


through system.

Worn out jet nozzle. Replace jet nozzle.

Vaccum leak of to atmosphere. Cheack and tighten all connections


to degasser Body and piping to
vacuum pump.

Drawing air from secondary Check that secondary pump is


vacuum pump. isolated when not in use.

Not degassing Inadequate vacuum. Check vacuum pump and motor.

Check connections from vacuum


pump to vessel.

Check float valve assembly.

18

www.nov.com/brandt
Document number M9251
Revision 4
Page 19 of 54

Maintenance & Repair

Maintenance
All maintenance to be performed on the DG Series Degasser should be done while the unit is
removed from service. Routine maintenance of the equipment can prolong the service life and
ensure optimum operational performance. Perform maintenance on the equipment immediately
after conclusion of functional operations. No special tools are required to work on the unit.

Routine maintenance
Startup
1. Check for proper vacuum of 15 to 24 in. Hg.
2. Check the oil level in the vacuum pump. Use ISO 150 oil (NOV Brandt P/N 46G) for normal
operation. Use ISO 32 oil (NOV Brandt P/N 46CK) for operating in cold weather conditions
of 40oF to -20oF (4oC to -29oC).

Do not operate the vacuum pump at temperatures below -20oF (-29oC).

3. Turn the vacuum pump sheave through several revolutions by hand to see that everything is
free and in working order.
4. Check that the belt tension is snug.
5. Check the float operated 3-way valve for free movement.
6. Check the motor rotation, which is counterclockwise viewed from the shaft end.
7. Check float valve in liquid trap for proper closure.
8. Check that the suction and discharge lines are submerged.
Daily
1. Drain the liquid trap.
2. Lubricate the 3-way valve.
3. Drain the condensate trap.
Periodically
1. Check the belt tension.
2. Remove and inspect the float valve in the liquid trap for wear or defect.

Note: If the unit is equipped with a secondary vacuum pump, it should be run once a week
to prevent seizing. Follow the startup maintenance instructions before bringing the unit
permanently online.

www.nov.com/brandt
Document number M9251
Revision 4 6: Maintenance & Repair
Page 20 of 54

Weekly
1. Check the vacuum pump oil level. Fill to the bottom of the fill plug threads.
2. Check the condensate traps. If an automatic drain trap is not used, drain at least weekly.
500 hours of operation
1. Change the oil.
2. Tighten all bolts.
1000 hours of operation
1. Inspect the vacuum pump valves. Clean, if necessary.
2. Inspect the motor. Clean, if necessary.
3. Clean the vacuum pump.
4. Clean the external surfaces of the cylinder and intercooler tubes, if necessary.
Jet Pump
The jet pump has no moving parts and requires no maintenance. Periodically check for piping
leaks or obstructions lodged in the nozzle.

Repair
DG Series Degassers are designed for minimal maintenance. Interior parts are corrosion resistant
and the level float is made of stainless steel. However, all mechanical parts may eventually need to
be replaced.

Replacing components
Motor replacement
1. Lockout/tagout power to the unit.
2. Remove the two bolts attaching the belt guard to the unit and remove the belt guard.

30

www.nov.com/brandt
Document number M9251
6: Maintenance & Repair
Revision 4
Page 21 of 54

3. Open the junction box and disconnect all wires.

4. Remove the four bolts attaching the motor to the unit.

5. Slide the motor toward the vacuum pump to increase slack in the belts.

6. Remove the belts from the motor and vacuum pump.

www.nov.com/brandt
Document number M9251
Revision 4 6: Maintenance & Repair
Page 22 of 54

7. Remove the three bolts that attach the pulley to the motor.

8. Place the three loose bolts into the three open holes in the pulley and push to separate the
pulley from the motor.

9. Place the new motor on the unit frame.

30

www.nov.com/brandt
Document number M9251
6: Maintenance & Repair
Revision 4
Page 23 of 54

10. Attach the pulley to the end of the motor using the three bolts you removed in step 7.

11. Place the belts (either new belts or the belts you removed in step 6) on the pulley and
vacuum pump.
12. Slide the motor into place so that the belt tension is snug.

13. Attach the motor using the four bolts you removed in step 4.

www.nov.com/brandt
Document number M9251
Revision 4 6: Maintenance & Repair
Page 24 of 54

14. Open the junction box and connect all wires.

15. Replace the belt guard and replace the two bolts to attach the belt guard to the unit.

16. Undo lockout/tagout.


17. Start the unit to check motor rotation.

30

www.nov.com/brandt
Document number M9251
6: Maintenance & Repair
Revision 4
Page 25 of 54

Vacuum Pump
1. Lockout/tagout all power to the unit.
2. Remove the two bolts attaching the belt guard to the unit and remove the belt guard.

3. Disconnect the inlet hose at the top of the t-valve.

4. Unscrew the t-valve from the vacuum pump.

www.nov.com/brandt
Document number M9251
Revision 4 6: Maintenance & Repair
Page 26 of 54

5. Loosen the four bolts attaching the motor to the unit.

6. Slide the motor toward the vacuum pump to increase slack in the belts.

7. Remove the belts from the motor and vacuum pump.


8. Remove the four bolts attaching the vacuum pump to the unit.

30

www.nov.com/brandt
Document number M9251
6: Maintenance & Repair
Revision 4
Page 27 of 54

9. Remove the vacuum pump from the unit.


10. Place the new vacuum pump on the unit frame.
11. Place the belts (either new belts or the belts you removed in step 7) on the pulley and
vacuum pump.
12. Slide the motor into place so that the belt tension is snug.

13. Tighten the bolts you loosened in step 5.


14. Attach the vacuum pump using the four bolts you removed in step 8.
15. Re-attach the t-valve you removed in step 4.

www.nov.com/brandt
Document number M9251
Revision 4 6: Maintenance & Repair
Page 28 of 54

16. Re-attach the hose you removed in step 3.

17. Replace the belt guard and replace the two bolts to attach the belt guard to the unit.

18. Undo lockout/tagout.

30

www.nov.com/brandt
Document number M9251
6: Maintenance & Repair
Revision 4
Page 29 of 54

Vacuum gauge
1. Lockout/tagout all power to the unit.
2. Unscrew the gauge from the tank.
3. Screw the new vacuum gauge onto the tank.

Be sure that the new gauge is a vacuum gauge. A pressure gauge or other gauge
does not provide a meaningful reading.

4. Undo lockout/tagout.

www.nov.com/brandt
Document number M9251
Revision 4 6: Maintenance & Repair
Page 30 of 54

Torque values

National coarse

Dia pitch Ft./lbs Mt/kg

Min. Max Min. Max

1/4 in - 20 6 7 0.83 0.97

5/16 in - 18 12 14 1.66 1.93

3/8 in - 16 21 24 2.90 3.32

1/2 in - 13 52 59 7.20 8.15

5/8 in - 11 105 120 14.50 16.60

3/4 in - 10 170 190 23.50 26.20

National fine

Dia pitch Ft./lbs Mt/kg

Min. Max Min. Max

1/4 in - 28 5 6 0.69 0.83

5/16 in - 24 9 10 1.25 1.38

3/8 in - 24 14 16 1.93 2.21

1/2 in - 20 40 42 5.52 5.80

5/8 in - 18 60 70 8.30 9.55

3/4 in - 16 100 120 13.80 16.60

1. These values apply unless noted otherwise.


2. Values shall be obtained by turning the nut and holding the bolt whenever possible.
3. This chart does not include values for stainless steel.
4. Coefficient of 0.17 for cadmium and 0.22 for zinc and 70% of the proof load.
5. Preload does not include the use of a lock nut.

30

www.nov.com/brandt
Document number M9251
Revision 4
Page 31 of 54

Parts and Drawings

Parts identification
All parts required for maintenance or repairs are available from NOV Brandt. Assembly drawings
and exploded views correspond to the parts list that identifies each part by number. Using this part
number and part name ensures procurement of the proper part when ordering spare parts.

Ordering replacement parts


All parts required for maintenance or repairs are available from NOV Brandt.
When ordering replacement parts, please provide the following information:
‰ Part name as called out on the applicable drawing.
‰ Part number as called out on the applicable drawing.
‰ Quantity.
‰ Serial number as shown on the nameplate (if applicable).

One-year recommended spare parts


DG-5 DG-10/DG12

Part Part
Quantity number Quantity number Description

1 2P 1 2P Belts (3 per set)

2 10AM 2 10AM Shaft seal

1 10AN 1 10AO Tank gasket

1 see page 12a 1 see page 12a Starter/Overload

Oil, Vacuum pump (sold in 5


1 46G 1 46G gallon pails) normal
temperature

Oil, Vacuum pump (sold in 5


1 46CK 1 46CK
gallon pails) cold temperature

1 53H 1 53H Filter element

1 75BM 1 75AZ Nozzle


a. Provide the Hp, Hz, voltage, and brand of starter for accurate part ordering.

www.nov.com/brandt
Page
Revision

22 23 22 23 22 23

23 23 23

26 27 28
12
26 27 28
Document number

23 22 21 29
4 1/16" [0.10]
22 22
16 24 25 14
12 12 12
3 17
32 35
21
4

10 27 28 33

P/N

JOB#
W.O.#
MODEL#

PATENT NO.
DATE OF MANUF.

CUSTOMER/P.O.#

MAX. UNIT WEIGHT


DIMENSIONS LxWxH
22 23 22 23 22

TANK & 8" PIPE


CFLANGE DISCHARGE
L
51" [1.30]
M9251

30" [0.76]
31 32 34
32 of 54

22 22 22

C.G.
22 1/2°
17
NOTES:
1) FEED MAY BE FROM EITHER SIDE OF SKID. FEED FLANGE IS 6".
2) GASKETS ARE REQUIRED ON ALL FLANGES.

ROTATION
22 1/2° 3) DISCHARGE FLANGE IS 8".
2]
1.5 8" PIPE 4) ALL FLANGES ARE ORIENTED FOR A TWO (2) BOLT PATTERN.
" [?
?60 7" [.177M] 5) VESSEL OPERATING CAPACITY (232 GALS)
8" FLANGE 6) VACUUM PUMP: FILL CRANKCASE WITH 2 1/2 QTS. OF OIL
P/N 46G
FURNISHED BY 7) BELT ADJUSTMENTS (2-OUTSIDE BELTS ONLY) DEFLECTION 1/4"
23 23 @ 1.3 TO 1.9 LBS. FORCE APPLIED PERPENDICULAR DOWN FROM

30" [0.76]
23 CUSTOMER
C TOP BELT LOOP AND AT CENTER OF SPAN.
26 27 28
L 8) FOR LIQUID TRAP ASSEMBLY. SEE REF. DWG. SA577

46
22 9) ITEM-31, -32, -34 TO BE USED FOR SHIPPING PURPOSES ONLY.
15

31 32 34

22 22 22

35 7/16" [0.90] 40" [1.02]

100" [2.54]

13

PLAN VIEW 20' [6.09M] MAX

13

14

CENTRIFUGAL PUMP
C
L DISCHARGE
2
100" [2.54]
6" FLANGE

7 18
6 36 VACUUM PUMP
EXHAUST 1 1/2" 8" FLANGE
[0.04M] NPT 13

FLOAT ASSY. C6 X 13#


C

77 9/16" [1.97]
DG-10 assembly A611 rev. 24

L 6 13/16" [0.17] 24

73 1/2" [1.87]
9
17

C
L
60" [1.52]

34 13/16" [0.88]
24

23 13/16" [0.61]
87 5/8" [2.23M]

C6 X 13#
C
L 6" PIPE FLANGE (FEED)
37" [0.94]
30 31 32

C.G.
51" [1.30]
65" [1.65M]

22 22 22

22 13/16" [0.58]

24
15 5/16" [0.39]
24

FOUDATION PLAN

C
L
DISCHARGE TO TANK
7: Parts and Drawings

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 33 of 54

Parts list for A611


Item # Part # Description Qty

2 564 Tank assembly 1

3 577 Vacuum plumbing 1

6 34BA Belt guard 1

7 23L Vacuum pump 1

9 2P Belt 1

10 Motor (options) 1

13 29I Gauge 1

14 44AF 1″ x 1 1/ 4″ NPT street elbow 1

16 55N 6″ blind flange 1

17 10AB 6″ gasket 1

18 JP-10 jet pump Ref

21 01-1904 Gland 2

22 01-1903 Shroud 2

23 01-1688 Armored cable x 5 ft., 14-4 1

24 22AJ Bolts 8

25 35AV Bolts 8

26 22E Hex bolt 8

27 35M Hex nut 12

28 36AT Washer 24

29 01-2046 Terminal 4

30 22Z HHCS 1/2-13 UNC X 2" 4

31 35K Nut hex 1/2" 4

32 36F Washer flat 1/2" 16

33 22JP HHCS 3/8-16 UNC X 1 3/4" 4

34 22V HHCS 1/2-13 UNC X 2 1/2" 4

35 22NB HHCS 1/2-13 UNC X 3/4" 1

36 48F Hose suction 1" 28 in.

www.nov.com/brandt
Page
7
Revision

NOTE:
THE GAP BETWEEN ITEMS #3 AND #13 SHOULD
BE 1/8" MAX. USE SPACERS (ITEM #16) AS
NEEDED. 14

SEE NOTE 16 13

1
Document number

3
4

1/8" REF.
4 4
M9251

6 7 8 9
34 of 54

SA564 rev. 11

5
15

46
66 9/16"

1/2" 6

48 1/16"
DG-10 internal subassembly

24 3/16"

6
19"

12 1/8"

30"R. 37"

60"DIA.
7: Parts and Drawings

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 35 of 54

Parts list for SA564


Item # Part # Description Qty

1 813 Tank top weldment Ref

2 5727 Skid and tank bottom weldment 1

3 43I Fiberglass leaf 7

4 75AW Detail 3 – tee weldment 1

5 575 Degasser float assembly 1

6 10A0 1/4″ THK BUNA-N gasket 63 1/2″ OD, 60″ ID 1

7 22Z 3/4″-13UNC x 2″ hex HD cap screw 24

8 36F 1/2″ plain washer 48

9 35K 3/4″-13UNC hex locknut 24

13 14B Victaulic clamp with gasket 1

14 42B Victaulic cap 1

15 44AY Elbow 45° –1″ NPT 1

16 5389 Spacer As many as required

www.nov.com/brandt
Document number M9251
Revision 4 7: Parts and Drawings
Page 36 of 54

JP-10 jet pump A988 rev. 0

46

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 37 of 54

Parts list for A988


Item # Part # Description Qty

1 75AY Venturi 1

2 75AZ Jet nozzle 1

www.nov.com/brandt
Document number M9251
Revision 4 7: Parts and Drawings
Page 38 of 54

DG-5 degasser assembly A747 rev. 14

46

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 39 of 54

Parts list for A747


ITEM QTY DESCRIPTION DWG. REF. PART NUMBER

1 1 SKID TANK C740


2 1 TANK ASSEMBLY SA487
3 1 VACUUM PLUMBING SA581
4 1 FLOAT ASSEMBLY SA521
5 1 HEATER, O.L. 13DK/DP
6 1 BELT GUARD C507 34BR
7 1 VACUUM PUMP 23L
8 1 SHEAVE MOTOR 4I
9 3 BELT 2P
10 1 MOTOR 1HD
11 1 BUSHING, MOTOR 3AJ
12 1 STARTER & ENCLOSURE 24BN
13 1 GAUGE 29I
14 1 1/4 NPT STREET ELBOW 44AF
15 1 1" - 1/4 NPT BUSHING 65AF
16 1 6" BLIND FLANGE 55N
17 1 6" GASKET - 1/8" THK 10AB
18 REF JP-5 JET PUMP A1000
19 1 SHROUD 01-1903
20 1 FTG, 3/4 NPT BICC 01-1904
21 1 TERMINAL, RING 14GA. - 1/4 01-2046
22 1 CABLE, ARMOR 14-4 01-1688
23 8 HHCS 3/4" 10UNC X 3 1/2" 22AJ
24 8 NUT HEX LOCK 3/4-10 UNC 35AV
25 7 HHCS 3/8" 16UNC X 1 1/2" 22E
26 11 NUT HEX LOCK 3/8-16 UNC 35M
27 24 WASHER FLAT 3/8" 36AT
28 4 HHCS 1/2" 13UNC X 2" 22Z
29 4 NUT HEX 1/2"-13 UNC 35K
30 16 WASHER FLAT 1/2" 36F
31 4 HHCS 3/8" 16UNC X 1 3/4" 22JP
32 4 HHCS 1/2" 13UNC X 2 1/2" 22V
33 1 HHCS 1/2" 13UNC X 3/4" 22NB

www.nov.com/brandt
Document number M9251
Revision 4 7: Parts and Drawings
Page 40 of 54

DG-5 internal subassembly SA487 rev. 17

46

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 41 of 54

Parts list for SA487


Item # Part # Description Qty

1 C809 Tank Top Weldment 1

2 C486 Tank Bottom Weldment 1

3 43H Fiberglass Leaf 4

4 C485 Detail 4 1

5 SA521 Degasser Float Assembly 1

6 10AN 1/4″ THK BUNA-N Gasket, 51 1/2″ OD 48″ ID 1

7 22AT 1/2″-13UNC x 1 1/2″ Hex Head Cap Screw 24

8 36F 1/2″ Plain Washer 48

9 35K 1/2″-13 UNC Hex Locknut 24

14 14B Victaulic Clamp with Gasket 1

15 42B Victaulic Cap 1

16 44AY Elbow, 45° 1″ NPT 1

17 5389 Spacer as required

www.nov.com/brandt
Document number M9251
Revision 4 7: Parts and Drawings
Page 42 of 54

JP-5 jet pump A1000 rev. 2

46

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 43 of 54

Parts list for A1000


Item # Part # Description Qty

1 75BL Venturi 1

2 75BM Jet Nozzle 1

www.nov.com/brandt
Document number M9251
Revision 4 7: Parts and Drawings
Page 44 of 54

DG-10 w/ Dual Vacuum Pump Assembly


A20510 rev. 0

46

www.nov.com/brandt
Document number M9251
7: Parts and Drawings
Revision 4
Page 45 of 54

Par ts list for A20510


ITEM QTY DESCRIPTION PART NUMBER

1 1 SKID / TANK SUB-ASSEMBLY 20524


2 1 VACUUM PLUMBING 577
3 1 FLOAT ASSEMBLY 575
4 2 BELT GUARD 34BA
5 2 VACUUM PUMP 23L
6 2 MOTOR OPTION -
7 2 BELT, SET (3) 2P
8 3 ANGLE CLIP, BELT GUARD/LIQUID TRAP 104-4
9 2 ANGLE CLIP F/TANK TOP 1017-4
10 1 STICKER 36" NOV BRANDT 76CN
11 1 VACUUM GAUGE 29I
12 1 MOUNTING BRACKET MTR/PUMP 93AM
13 1 FLANGE, BLIND 6" 55N
14 1 GASKET, 6" 10AB
15 1 1/4" NPT STREET ELBOW 44AF
16 9 SHROUD 3/4" NPT 01-1903
17 12.5ft ARMORED CABLE, 14GA. 01-1688
18 12 HHCS 3/8" 16UNC X 1 1/2" 22E
19 2 1" NPT STREET ELBOW 44AH
20 9 GLAND, 3/4" NPT 01-1904
21 9 TERMINAL, RING TONGUE 14GA. X 1/4" 01-2046
22 1 NAME PLATE 63L
23 4 HHCS 5/8" 11UNC X 1 3/4" 22NO
24 4 NUT HEX LOCK 5/8" 11UNC NYL-INSR 35V
25 8 WASHER FLAT 5/8" 36AP
26 8 HHCS 1/2" 13UNC X 2" 22Z
27 8 NUT HEX LOCK 1/2" 13UNC NYL-INSR 35K
28 16 WASHER FLAT 1/2" 36F
29 8 HHCS 3/8" 16UNC X 1 3/4" 22JP
30 36 WASHER FLAT 3/8" 36AT
31 20 NUT HEX LOCK 3/8" 16UNC NYL-INSR 35M
32 8 HHCS 3/4" 10UNC X 3 1/2" 22AJ
33 8 NUT HEX LOCK 3/4" 10UNC NYL-INSR 35AV
34 10.5ft. HOSE SUCTION 1" 48F
35 2 NIPPLE 1" KC 47BB
36 2 VALVE BALL 1" #125 NPT BNZ 31AH
37 3 NIPPLE CLOSE 1" SCH 80 47EA
38 1 TEE 1" NPT 49J
39 1 STARTER MOUNTING PLATE 20532
40 2 HHCS 1/4" 20UNC X 1 1/4" 22AH
41 4 WASHER FLAT 1/4" 36BX
42 2 NUT HEX 1/4" 20UNC NYL-INSR 35CA
43 1 JUNCTION BOX 69AD
44 4 SHCS 3/8"-16UNC X 1 1/2" FLT HD 04-536

www.nov.com/brandt
Document number M9251
Revision 4 7: Parts and Drawings
Page 46 of 54

Supporting Documents
D255 Ingersol Rand Vacuum Pump Manual

46

www.nov.com/brandt
Document number M9251
Revision 4
Page 47 of 54

Worldwide Locations

Corporate offices

NOV CORPORATE HEADQUARTERS Far East


10000 Richmond Avenue 39 Gul Avenue
Houston, TX 77042 Singapore 629679
United States Phone: 65 6862 1169
Phone: 713 346 7500 Fax: 65 6862 0183
Fax: 713 435 2195 brandtsingaporesales@nov.com

NOV BRANDT HEADQUARTERS Middle East, Northern Africa & Caspian


2800 N. Frazier Street Al Quoz Industrial Area
Conroe, Texas 77303 P.O. Box 22148
United States Dubai
Phone: 936 523 2600 United Arab Emirates
Fax: 936 788 7367 Phone: 971 4 347 2468
brandt@nov.com Fax: 971 4 347 2340
brandt-dubai@nov.com
Canada
#1600 - 540 - 5th Avenue SW North Sea, Europe & Western Africa
Calgary, Alberta T2P 0M2 Badentoy Way
Canada Badentoy Park
Phone: 403 264 9646 Portlethen, Aberdeen AB12 4YS
Fax: 403 263 8488 Scotland
Phone: 44 1224 787700
Capital Sales, Leasing & Latin America Fax: 44 1224 784555
12950 West Little York Road ukbrandtsales@nov.com
Houston, Texas 77041
United States
Phone: 713 856 4100
Fax: 713 856 4133

International

Algeria Angola
Zone industrielle N° 2 AES Facility
Hassi Messaoud BP561 Sonils Base
Algeria Luanda
Phone: 21329731592 Angola
Fax: 21329731592 Phone: 244 222 311 115
Fax: 244 222 311 058

www.nov.com/brandt
Document number M9251
Revision 4 8: Worldwide Locations
Page 48 of 54

Argentina Brazil
Corrientes 330, 5to. Piso Oficina 516 Rua Paulo Henrique Machado Pimentel No. 02
Buenos Aries Bairro Ignacio Barbosa - DIA
Argentina C1043AAQ Aracaju, Sergipe
Phone: 54 114 394 3939 Brazil
Fax: 54 114 394 4499 CEP: 49.040.000
Phone: 55 79 3249 3510
Parque Industrial Este Fax: 55 79 3249 1988
Lote 3, Sector Este
Neuquén Capital Av. Amaral Peixoto S/N Km 164.5
Provincia de Neuquén Bairro Imboassica
Argentina CP 8300 Macaé
Phone: 54 299 441 3123 Brazil
Phone: 54 299 441 3185 CEP: 27.925-290
Phone: 54 299 441 3323 Phone: 55 22 2773 0600
Phone: 54 299 441 3207 Fax: 55 22 2773 0606
Fax: 54 299 441 3207
Canada
Azerbaijan Bay 2, 5402 - 55th Avenue
Kermur Plaza Bonnyville, Alberta T9N 2K6
Basti Bagirova Street Canada
Baku Phone: 780 826 2263
Azerbaijan AZ1065 Fax: 780 826 2296
Phone: 994 12 4367712
Fax: 994 12 4367712 11453 - 97th Avenue
Grande Prairie, Alberta T8V 5R8
Canada
Australia
Phone: 780 538 1615
160 Welshpool Road
Fax: 780 538 1896
Welshpool, Perth WA 6106
Australia
6621 - 45th Street
Phone: 61 8 9358 0599
Leduc, Alberta T9E 7E3
Fax: 61 8 9358 0577
Canada
Phone: 780 986 6063
Bolivia
Fax: 780 986 6362
KM. 6.5 Doble vía a la Guardia
Casilla de Correo 3813
Bay 6, 4800 - 46th Avenue
Santa Cruz de la Sierra
Fort Nelson, British Columbia V0C 1R0
Bolivia
Canada
Phone: 591 3 3553500
Phone: 250 775 6995
Fax: 591 3 3553501
Fax: 250 775 6996
KM 1 Carretera a Santa Cruz
77 Escana Street
Yacuiba - Tarija
Estevan, Saskatchewan S4A 2L7
Phone: 591 4 6825981
Canada
Fax: 591 4 6825982
Phone: 306 634 3351
Fax: 306 634 1299

52

www.nov.com/brandt
Document number M9251
8: Worldwide Locations
Revision 4
Page 49 of 54

China Germany
Suite 1603-1606, Air China Plaza Lanterstrabe 34C
No. 36 Xiaoyun Road 46539 Dinslaken
Chaoyang District Germany
Beijing 100027 Phone: 49 206 482 6358
People's Republic of China Fax: 49 206 482 6358
Phone: 86 10 8447 5109
Fax: 86 10 8447 5898 India
413-416, 4th Floor
Colombia Solaris 1 'C' Wing Opposite L&T
Carrera 9A No. 97A-53 Gate #6, Sakir Vihar Road
4to. Piso, Edificio Siracusa Oficina #403 Powai - Andheri (East)
Bogota, D.C. Mumbai 400 072
Colombia
India
Phone: 57 1 644 4510
Phone: 91 22 4005 8100
Fax: 57 1 623 4455
Fax: 91 22 4005 8102
Denmark
Indonesia
Klintholmvej 49
Jl. M.T. Haryono No. 119
5874 Hesselager
RT. 33A/RW 11 Ring Road
Denmark
Balikpapan 76114
Phone: 45 62 251358
Indonesia
Fax: 45 62 251818
Phone: 62 0542 871 769
soil@soil-recovery.dk
Fax: 62 0542 871 756
Ecuador
Annex Building, 1st Floor
Ave. Amazonas No. 3655 y
Jl. Ampera Raya 9-10
Juan Pablo Sanz
Cilandak
Edificio Antisanal. 1, Piso 3
Jakarta Selatan 12550
Quito
Indonesia
Ecuador
Phone: 62 21 7827383
Phone: 593 2 224 3224
Fax: 62 21 7827384
Fax: 593 2 224 4880
Kazakhstan
Egypt
74A, Azattyk Avenue
23 Road
Atyrau 060005
265 Maadi
Kazakhstan
Cairo
Phone: 0073122457190
Egypt
Fax: 0073122457346
Phone: 202 516 6160
Fax: 202 754 4051
Malaysia
B-20-7 Megan Phileo Avenue
12 Jalan Yap Kwan Seng
50450 Kuala Lumpur
Malaysia
Phone: 603 21666 022
Fax: 603 21666 077

www.nov.com/brandt
Document number M9251
Revision 4 8: Worldwide Locations
Page 50 of 54

No. 15 Jalan Utarid U5/16 Norway


Mah Seng Integrated Industrial Park Myklabergveien 4
Section U5 4314 Sandnes
40150 Kuala Lumpur Norway
Malaysia Phone: 47 51 20 52 00
Phone: 603 7845 9783 Fax: 47 51 20 52 01
Fax: 603 7845 9738
Oman
IR 10/10 Lusu Warehouse PO Box 1376
Jalan Patau - Patau PC 133 - Al Khuwair
87000 Labuan F.T Muscat
Malaysia Sultanate of Oman
Phone: 60 087 423 886 Phone: 00968 24 484070
Fax: 60 087 423 885 Phone: 00968 24 483703
Phone: 00968 24 478122
WH 8 Door No. 2 Fax: 00968 24 487655
Kemaman Supply Base
24007 Kemaman Supply Base Peru
Terengganu Darul Iman Mariano de los Santos 183 of 402
Malaysia San Isidro
Phone: 60 087 423 886 Lima 27
Fax: 60 087 423 885 Peru
Phone: 51 1 221 1813
Mexico Fax: 51 1 222 2474
Lote 4, Manzana 1
Parque Industrial Deit Russia
rd
Rancheria Anacleto Canabal Ulansky Lane 5, 3 Floor
Villahermosa, Tabasco Moscow 101000
Mexico 86500 Russia
Phone: 52993 310 3100 Phone: 7 495 775 2540
Fax: 52993 310 3109 Fax: 7 495 981 3470
brandt.moscow@nov.com
The Netherlands
De Hulteweg 3b Qatar
7741 LE Coevorden PO Box 4455
The Netherlands Doha
Phone: 31 524 582718 Qatar
Fax: 31 524 534814 Phone: 9744621243
Fax: 9744622235
Nigeria
Delta Environmental Facility Saudi Arabia
Oil and Gas Free Zone Vetco Saudi Arabia Ltd.
Federal Lighter Terminal P.O. Box 31849
Onne, Rivers State Al Khobar 31952
Nigeria Kingdom of Saudi Arabia
Phone: 234 084 236240 Phone: 966 3 882 6300
Fax: 234 084 236714 Fax: 966 3 882 9595

52

www.nov.com/brandt
Document number M9251
8: Worldwide Locations
Revision 4
Page 51 of 54

Thailand Venezuela
No. 18 SCB Park Plaza West Apartado 128
Building 2 , 15th Floor, Room 215A Carretera Negra Al Lado Campo
Ratchadapisek Road Las Palmas
Kwang Chatuchak, Khet Chatuchak Anaco, Estado Anzoátegui
Bangkok 10900 Venezuela
Thailand Phone: 58 282 4222808
Phone: 66 2 937 5657 Fax: 58 282 4222473
Fax: 66 2 937 5660
Av. 58 No. 140-315
Trinidad Zona Industrial, 1era. Etapa
Building 5A Maracaibo, Estado Zulia
Edoo's Industrial Complex Venezuela
South Trunk Road Phone: 58 261 7379619
La Romain, Trinidad Fax: 58 261 7379624
Phone: 868 652 3707
Fax: 868 657 9771

United States

Arkansas Colorado
600 S. German Lane, Building 2 1630 Welton Street, Suite 300
Conway, Arkansas 72034 Denver, Colorado 80202
United States United States
Phone: 501 327 2700 Phone: 303 592 9250
Fax: 501 327 2706 Fax: 303 825 1578

California 1936 CR 319


7300 Downing Avenue Rifle, Colorado 81650
Bakersfield, California 93308 United States
United States Phone: 970 625 1201
Phone: 800 725 4977 Fax: 970 625 1302
Phone: 661 588 8503
Fax: 661 588 8506 Louisiana
4178 Trailer Town Road
9711 Holland Street, Suite 2 Jennings, Louisiana 70546
Bakersfield, California 93312 United States
United States Phone: 800 359 5951
Phone: 661 615 6456 Phone: 337 774 5951
Fax: 661 615 6457 Fax: 337 774 2347

430 Douglas Lane 201 Energy Parkway, Suite 310


Woodland, California 95776 Lafayette, Louisiana 70508
United States United States
Phone: 530 666 6475 Phone: 337 235 5325
Fax: 530 666 4726 Fax: 337 235 3739

www.nov.com/brandt
Document number M9251
Revision 4 8: Worldwide Locations
Page 52 of 54

618 N. Hangar Drive Texas


New Iberia, Louisiana 70560 5764 Highway 380
United States Bridgeport, Texas 76426
Phone: 800 359 5935 United States
Phone: 337 235 5935 Phone: 940 683 6286
Fax: 337 365 0375 Fax: 940 683 6236

1515 Poydras Street, Suite 1850 426 Flato Road


New Orleans, Louisiana 70112 Corpus Christi, Texas 78405
United States United States
Phone: 504 636 3660 Phone: 800 725 4974
Fax: 504 636 3670 Phone: 361 289 7794
Fax: 361 289 9058
North Dakota
2902 N. Mechanic Street
4965 2nd Street S.W.
El Campo, Texas 77437
Dickinson, North Dakota 58601
United States
United States
Phone: 800 725 4974
Phone: 800 584 3065
Phone: 979 578 9076
Phone: 701 227 8608
Fax: 979 578 9098
Fax: 701 227 8612
4710 Andrews Highway
Oklahoma
Odessa, Texas 79762
3214 Highway 270
United States
East Wilburton, Oklahoma 74578
Phone: 888 563 0663
United States
Phone: 432 550 6802
Phone: 940 683 6286
Fax: 432 550 3190
Phone: 918 448 8488
Fax: 918 465 5633
8472 N. Highway 79
Palestine, Texas 75801
919 S. 17th Street
United States
Yukon, Oklahoma 73099
Phone: 800 725 4974
United States
Fax: 903 584 0265
Phone: 800 725 4986
Phone: 405 350 7077
1305 E. San Benito Street
Fax: 405 354 6749
Rio Grande City, Texas 78582
United States
1 3/4 Hwy 6
Phone: 956 716 6561
Elk City, Oklahoma 73644
Fax: 956 716 6561
United States
Phone: 580 225 0590
Wyoming
Fax: 580 225 8410
521 Winkleman Avenue
Marbleton, Wyoming 83113
United States
Phone: 307 276 4405
Fax: 307 276 4407

52

www.nov.com/brandt
Document number M9251
Revision 4
Page 53 of 54

Index

C International, 47 Routine Maintenance, 7


Cautions, 5
Conventions, 5
N S
Notes, 5 Safety Requirements, 6
Corporate offices, 47

G P U
Personnel Training, 6 United States, 51
General System Safety
Practices, 6 Proper Use of Equipment, 7
W
I R Warnings, 5
Illustrations, 5 Recommended Tools, 6 Warranty, 7
Replacing Components, 6 Worldwide Locations, 47

www.nov.com/brandt
Document number M9251
Revision 4 Index
Page 54 of 54

54

www.nov.com/brandt

Вам также может понравиться