JOB lD No. OCSK/JN/1llUU - 0001 Date: 13.12.2019


Ref.No. : SGS/AirporUAgartala/NITB/PMC/17-18fiR-146 Product ASTM 8221,6005, T5
Date: 21.11.2019 Specification
lssued To : M/s- SGS lndia Pvt. Ltd. Test Specification ASTM E 1251:2017
. Agartala, Airport Project
On A/c of M/s- NCC Ltd.
Description : 1no. Aluminium Section (Size: 50.8 X25.4X Seal/ Stamp / Mark : Nil
of 2m'm) sample for the following tests. (if any)
Sample(s) Brand: TALCO 2128
, Sub: Construction of New lntegrated Terminal-
Building and Associated Works of Agartala
Airport, Agartala, Tripura -Chemicall testing of
Aluminium Section for HCP work - Reg
Ref: (1)Agreement No. 03/ED Engg- CHQ
(N ER/AGM( EC)/Agartala/N ITB/20 1 7, Dated :
15.06.2017
Test : o/oCu, % Al, %Zn, o/o Cr, Yo Mn, %o Fe, %
Si, Sample received on 29.11.2019
Parameters %Mg & %Ti
Sample tested on 29.11.2019 to
12.12.2019
This is to certify that the above sample (S) has/have been tested with the

CHEMICAL PROPERTIES
Metals & AIloys - Aluminum & its alloys
Characteristics Findings Req. as per Req. as perASTM
8221,6005
i
-'1-

1. % Copper (as Cu) 0.06 0.10 Max.


2. % Aluminium (as Al) 98.87 Remainder
3. o/o Zinc (as Zn) Trace 0.10 Max.
4. % Chromium (as Cr) 0.007 10 Max.
5. % Manoanese (as Mn) 0.007 0.10 Max.
6. % lron (as Fe) 0.26 0.35 Max.
7. % Silicon (as Si) 0.75 0.60 - 0.90 ---r
---1-
B. % Maqnesium (as Mq) 0.43 0.40 - 0.60 -r
9. % Titanium (as Ti) 0.015 0.10 Max
Remarks: The above submitted sample was duly tested as per relevant specification and found satisfactory with
respect to the above test parameters.
' FoTOMEGAC [usu"rnmsERVTcES
-------A.,&t----
Prepared/By

(AUTHCRTSED STGNATORY)

Note:
* Analysed as on reeived basis and test results relate to the sarple(s) only.
* Liability for retum of sample(s) ceases after ffieen days.
* The reppduc'tion of the report except in full is invalid without written approval of the laboratory.
* The tesl results refened in certiftcate are based on observations & measurements under the stated environmental conditions.
* The Test Report without EIIIBOSSING is lnvalid.