Вы находитесь на странице: 1из 5

TABLE OF CONTENTS

REPUBLIC OF THE PHILIPPINES


DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
8
A 01 OFFICE OF THE BUILDING OFFICIAL
SHEET NO. SHEET TITLE
8.00
2.25 2.75 3.00
ARCHITECTURAL DWGS.

0.40

0.40
PERSPECTIVES
SITE DEVELOPMENT PLAN
A-00
LOCATION MAP
VICINITY MAP

QUEZON CITY
GROUND FLOOR PLAN

4.20

4.20
SECOND FLOOR PLAN DISTRICT/CITY/MUNICIPALITY
ROOF PLAN
A-01
ELEVATIONS
9
SECTIONS
A 01 DOORS & WINDOWS SCHED.

1.30
STRUCTURAL DWGS.

11.00
FOUNDATION PLAN

4.20
SECOND FLOOR FRAMING PLAN

2.25
S-01 ROOF FRAMING PLAN
DETAILS LAND USE & ZONING
GENERAL NOTES

ELECTRICAL DWGS.

1.90
2.15
LIGHTING LAYOUT
POWER LAYOUT
E-01

0.90
GENERAL NOTES
SCHEDULE OF LOADS
SIDE WALK
LINE & GRADE
SANITARY DWGS.
ROAD
SANITARY LAYOUT
WATER LINE LAYOUT
P-01
3.70 2.30 2.00 GENERAL NOTES
8.00 ISOMETRIC LAYOUT

1 PERSPECTIVE 2 SITE DEVELOPMENT PLAN


A.00 SCALE NTS A.00 SCALE 1:100 M
ARCHITECTURAL

SM CITY
NOVALICHES COMMONWEA
SITE LTH STRUCTURAL

DON JULIO GREGORIO SITE WEST CLASSIC


GARDENS FAIRVIEW

WY
CAMELLA GLENMONT

OH

REGALADO AVE.
TRAILS

RIN

COMMONWEALTH
RE

QUI
NAVAL ST.

PU
BLIC BAGBAG
AV
E
CAMELLA
REPUBLIC AVE.
GLENMONT
NIA VILLAGE ELECTRICAL
CAMELLA GLENMONT
MINDANAO AV

DON ANTONIO
NAVAL ST. TANDANG SORA PASONG TAMO HEIGHTS
E.

3 LOCATION MAP 4 VICINITY MAP


A.00 SCALE NTS A.00 SCALE NTS SANITARY

MECHANICAL

ARCHITECT ARCHITECT'S SEAL RA 545, SEC. 25, PAR. 4 ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
These Drawings acting as
D&A instruments of service, are the
ARCHITECTURAL DESIGN property and documents of the
ARCHITECT. It shall be unlawful for
STUDIO any person, without the written PROPOSED TWO-STOREY PERSPECTIVES
consent of the architect or author
RESIDENCE EXTENSION MS. FAITH EUNICE
09778437739
da.archlstudio@gmail.com
ALYSSA LYNN FRENCILLO-GIMENA, uap
of said documents, to duplicate or
to make copies of said documents
for use in the repetition of and for B11 L10, Camella Glenmont, PINGKIAN
SITE DEVELOPMENT PLAN
LOCATION MAP
VICINITY MAP
A.00
other projects or buildings, Brgy. Sauyo, Q.C.
PRC NO. 32542 VALID UNITL: 3-19-2020 whether executed partly or in PRC NO. TIN:
whole.
PTR NO. 2301713 ISSUED: 01-28-2020, SJDM PTR NO. ISSUED:
8 8 8
A 01 A 01 A 01
A B C A B C A B C
±8.00 ±8.00 ±8.00
±2.25 ±2.75 ±3.00 ±2.25 ±3.00 ±2.75 ±2.25 ±2.75 ±3.00
EXISTING

±0.40

±0.40
EXISTING
±1.00

±1.00

±1.00
MAIDS' LAUNDRY
W5 OPEN

±1.75
ROOM AREA
W4 DIRTY W3 W4 W3

±2.30
1 KIT. 1 1
D5

STO. D4 T&B W6
T&B

±4.25
±4.20
±3.25
DN

±1.95
D3

±3.65

±3.60
BEDROOM
D5 2
KIT.
D6

±3.50
9 DINING 9 9
A 01 A 01 A 01
D6 D6
2 UP 2 2

±6.50
±11.00

±11.00

±11.00

±11.00
D2
new sliding doors w/ grills

±4.55

±4.00
PET'S

±3.60
±3.60

±3.60
LIVING
CAGE

±4.20
BEDROOM 1 MASTER
D1 BEDROOM

GARAGE

±5.20
3 W2 W1
3 W2 W3
3

±1.25

±1.90
EXISTING

new sliding doors w/ grills


±2.75

±2.75

±2.75
GARDEN

±2.15
W2 D7 W2

±1.50
BALCONY

±0.90
±3.95 ±4.05 ±3.70 ±2.30 ±2.00
±8.00 ±8.00
±4.00 ±1.20 ±2.80

1 GROUND FLOOR PLAN 2 SECOND FLOOR PLAN 3 ROOF PLAN


A.01 SCALE 1:100 M A.01 SCALE 1:100 M A.01 SCALE 1:100 M

EXISTING FIREWALL HT. EXISTING FIREWALL HT. EXISTING FIREWALL HT. EXISTING FIREWALL HT.
±0.40

±0.40

±0.40

±0.40
ROOF APEX VERIFY ON SITE ROOF APEX VERIFY ON SITE ROOF APEX VERIFY ON SITE ROOF APEX VERIFY ON SITE
±2.00

±2.00

±2.00

±2.00
±1.10

2F C.H. - VERIFY ON SITE 2F C.H. - VERIFY ON SITE 2F C.H. - VERIFY ON SITE 2F C.H. - VERIFY ON SITE
±2.40

±2.40

±2.40

±2.40
±2.20
±7.80

±7.80

±7.80

±7.80
±1.10

2FL - VERIFY ON SITE 2FL - VERIFY ON SITE 2FL - VERIFY ON SITE 2FL - VERIFY ON SITE
±0.35

±0.35

±0.35

±0.35
GF C.H. - VERIFY ON SITE GF C.H. - VERIFY ON SITE GF C.H. - VERIFY ON SITE GF C.H. - VERIFY ON SITE
±2.85

±2.85

±2.85

±2.85

±2.85
±2.50

±2.50

±2.50

±2.50
GFL - VERIFY ON SITE GFL - VERIFY ON SITE GFL - VERIFY ON SITE GFL - VERIFY ON SITE
NGL NGL NGL NGL
±0.15

±0.15

±0.15

±0.15
4 FRONT ELEVATION 5 LEFT SIDE ELEVATION 6 RIGHT SIDE ELEVATION 7 REAR ELEVATION
A.01 SCALE 1:100 M A.01 SCALE 1:100 M A.01 SCALE 1:100 M A.01 SCALE 1:100 M

REFER TO INTERIOR DESIGNER'S DRAWINGS FOR DOOR DESIGNS


±0.90 ±1.60 ±0.70 ±0.65 ±0.60 ±0.80 ±1.40
D1 D2 D3 D4 D5 D5 D6
EXISTING FIREWALL HT. EXISTING FIREWALL HT.
±0.40

±0.40

±2.10

±2.10

±2.10

±2.10

±2.10

±2.10

±2.10
ROOF APEX VERIFY ON SITE ROOF APEX VERIFY ON SITE
±2.00

±2.00

FFL FFL FFL FFL FFL FFL FFL

2F C.H. - VERIFY ON SITE 2F C.H. - VERIFY ON SITE TYPE SOLID PANEL SWING TYPE WHITE POWDER COATED TYPE SOLID PANEL TYPE WOOD SLIDING TYPE WOOD SWING TYPE WOOD SWING TYPE WHITE POWDER COATED
DOOR SLIDING DOOR SWING DOOR FLUSH DOOR FLUSH DOOR FLUSH DOOR SLIDING DOOR
LOC. MAIN DOOR LOC. KITCHEN LOC. LAUNDRY LOC. GF T&B LOC. T&B, MAIDS RM LOC. BEDROOMS LOC. MASTER BEDROOM
QTY. 1 SET QTY. 1 SET QTY. 1 SET QTY. 1 SET QTY. 2 SETS QTY. 3 SETS QTY. 1 SET
±2.40

±2.40
±7.80

±7.80

±1.20 ±0.40 ±1.20 ±0.60 ±0.60 ±1.20


2FL - VERIFY ON SITE HALLWAY BEDROOM 1 2FL - VERIFY ON SITE HALLWAY BEDROOM 2
W1 W2 W3 W4 W5 W6

±1.50 ±0.60
±0.35

±0.35

±0.90
GF C.H. - VERIFY ON SITE

±0.90 ±1.20

±0.90 ±1.20

±0.90 ±1.20
GF C.H. - VERIFY ON SITE

±1.60
±2.10

±2.10

±2.10

±2.10

±2.10

±2.10
±0.40
±2.85

±2.85

F F

±1.20
±2.50

±2.50

±0.50
FFL FFL FFL FFL FFL FFL

TYPE WHITE POWDER COATED TYPE WHITE POWDER COATED TYPE WHITE POWDER COATED TYPE WHITE POWDER COATED TYPE TYPE WHITE POWDER COATED
GFL - VERIFY ON SITE MAIDS RM DINING LIVING GFL - VERIFY ON SITE DINING KIT. JALOUSIE WINDOW
SLIDING WINDOW SWING WINDOW SLIDING WINDOW AWNING WINDOW AWNING WINDOW
NGL NGL LOC. LIVING LOC. LIVING, BEDROOMS LOC. BEDROOM 1,2 & STAIRS LOC. T&B LOC. MAID'S ROOM LOC. T&B
±0.15

±0.15

8 SECTION A 9 SECTION B QTY. 1 SET QTY. 4 SETS QTY. 3 SETS QTY. 2 SETS QTY. 1 SET QTY. 1 SET
A.01 SCALE 1:100 M A.01 SCALE 1:100 M

10 DOORS AND WINDOWS SCHEDULE


A.01 SCALE 1:100 M

ARCHITECT ARCHITECT'S SEAL RA 545, SEC. 25, PAR. 4 ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
These Drawings acting as
D&A instruments of service, are the
ARCHITECTURAL DESIGN property and documents of the
ARCHITECT. It shall be unlawful for
STUDIO any person, without the written PROPOSED TWO-STOREY GROUND FLOOR PLAN
SECOND FLOOR PLAN
consent of the architect or author
RESIDENCE EXTENSION MS. FAITH EUNICE
09778437739
da.archlstudio@gmail.com
ALYSSA LYNN FRENCILLO-GIMENA, uap
of said documents, to duplicate or
to make copies of said documents
for use in the repetition of and for B11 L10, Camella Glenmont, PINGKIAN
ROOF PLAN
ELEVATIONS
SECTIONS
A.01
other projects or buildings, Brgy. Sauyo, Q.C. DOORS AND WINDOWS SCHEDULE
PRC NO. 32542 VALID UNITL: 3-19-2020 whether executed partly or in PRC NO. TIN:
whole.
PTR NO. 2301713 ISSUED: 01-28-2020, SJDM PTR NO. ISSUED:
A B C A B C A B C A B C

LAUNDRY c3 LAUNDRY
MAIDS' OPEN LP-5 MAIDS' OPEN
ROOM AREA DIRTY z3 ROOM AREA DIRTY
1 KIT. 1 1 KIT. PP-7
1
t7 LP-6
St7 EF
a1 a1 t6 PP-14 PP-10
STO. S3t3 z2 T&B p3 EF STO. PP-6T&B

Sc2 Sc3
Sa1 EF S3t6 z3 T&B
a2 a2 PP-13T&B

S3p3 t8
S3t6
DN t13 DN
z2 LP-2 Sa2 EF
t2 LP-3 BEDROOM c9 PP-3 BEDROOM
2 t14

St13 t14 c9
2
KIT. t8 t8 KIT.
DINING DINING
c2
p2 S3t9 t10 c4 S3t11 t12 c6
2 UP t3 t4 t5 2 2 UP PP-5 2
S3p3 t8
PP-1 PP-2
t2 PP-8
c6
PP-9
St2 t3 p2 St4 t5 new sliding doors w/ grills t9 new sliding doors w/ grills

S3t11 c7
S3t1 c1 S3p1 z1
PET'S PET'S
LIVING LIVING

S3t9 t10 c5
CAGE z1 z1 CAGE
BEDROOM 1 MASTER BEDROOM 1 MASTER
p1 BEDROOM BEDROOM
t1 c1 t1 t10 PP-4 PP-11
t9 t11 t11
c1 z1
GARAGE c5 c4 GARAGE

S3z1
3 LP-1 3 c7 3 3
c6
PP-12

z1 z1 t12
new sliding doors w/ grills new sliding doors w/ grills

GARDEN LP-4 GARDEN

BALCONY BALCONY

1 GROUND FLOOR LIGHTING LAYOUT 2 SECOND FLOOR LIGHTING LAYOUT 3 GROUND FLOOR POWER LAYOUT 4 SECOND FLOOR POWER LAYOUT
E.01 SCALE 1:100 M E.01 SCALE 1:100 M E.01 SCALE 1:100 M E.01 SCALE 1:100 M

GENERAL NOTES: POWER LEGEND:


1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE DUPLEX CONVENIENCE OUTLET
WITH APPLICABLE PROVISION OF THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE REQUIREMENTS OF THE LOCAL AIRCON OUTLET
AUTHORITIES ENFORCING THE CODE AND REQUIREMENTS OF THE
COMPANY CONCERNED. REF

MICROWAVE OVEN MERALCO SERVICE ENTRANCE MAIN: 150AT,2P


2. TYPE OF CONDUIT WIRING SHALL BE DONE AS FOLLOWS:
230V,2P,3W,60Hz 230V
IMC - FOR MAIN SERVICE ENTRANCE
PVC - FOR BRANCH CIRCUITS AND FOR AUXILIARY CIRCUITS RANGE HOOD
15AT,2P 15AT,2P
3. ALL JUNCTION, UTILITY, SQUARE AND PULL BOXES SHALL BE GA#16 WATER HEATER
2-30mm² THHN 1 2
OR APPROVED EQUIVALENT AND PAINTED WITH ONE COAT PRIMER 15AT,2P
PRIOR TO INSTALLATION. WASHING MACHINE & 1-8.0mm² THHN 15AT,2P
IN 32mmØ IMC SM CITY
3 4 NOVALICHES COMMONWEA
4. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE
APPROVED TYPE. APPROPRIATE WITH LOCATION AND INTENDED TO BE
DATA
M 15AT,2P 15AT,2P LTH

USED. TELEPHONE
5
20AT,2P 20AT,2P
6
SITE WEST CLASSIC
GARDENS FAIRVIEW

WY
5. POWER SUPPLY SHALL BE 230 VOLTS, SINGLE PHASE, 2 POLE, 60 CABLE TV 7 8

OH

REGALADO AVE.
150AT,2P 230V 20AT,2P 20AT,2P

RIN
HERTZ, THREE WIRE SYSTEM.

COMMONWEALTH
IN NEMA 3R

QUI
PANEL BOARD
9 10 BAGBAG
6. ALL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION ENCLOSURE 20AT,2P 20AT,2P
OF QUALIFIED AND A DULY LICENSED ELECTRICAL ENGINEER OR
11 12
MASTER ELECTRICIAN. LIGHTING LEGEND: 20AT,2P 20AT,2P CAMELLA
REPUBLIC AVE.
GLENMONT
7. MINIMUM SIZE OF CONDUCTORS SHALL BE 3.5mm² THHN IN 15mm 13 14
PIN LIGHT NIA VILLAGE
DIAMETER TRADE SIZE. 20AT,2P 20AT,2P
SURFACE MOUNTED LIGHT 15 16

MINDANAO AV
8. ALL VERTICAL AND HORIZONTAL CONDUIT SHALL BE CONCEALED OR
EMBEDDED ON CONCRETE WALLS AND FLOORS. 20AT,2P 20AT,2P
CEILING FAN 17 18
9. ALL CONDUITS SHALL BE PROPERLY REAMED PRIOR TO INSTALLATION 20AT,2P 20AT,2P DON ANTONIO
TO AVOID DAMAGES TO THE SKIN OF WIRE. TANDANG SORA PASONG TAMO HEIGHTS

E.
PENDANT LIGHT 19 20
10. WORKMANSHIP OF THE WORK THROUGHOUT SHALL BE EXECUTED IN 20AT,2P 20AT,2P
THE BEST MOST THOROUGH MANNER KNOWN TO THE TRADE AND TO LED STRIP LIGHT 21 22
THE SATISFACTION OF THE ARCHITECT AND THE ENGINEER.
EF EXHAUST FAN
20AT,2P 20AT,2P 6 VICINITY MAP
23 24 E.01 SCALE NTS
11. VERIFY MOUNTING HEIGHTS & EXACT LOCATIONS OF WIRING DEVICES
WITH THE ARCHITECT PRIOR TO INSTALLATION. TRACK LIGHT (SET OF 3)
NOTE: G
TRACK LIGHT (SET OF 4)
THE CONTRACTOR IS ADVISED TO VISIT THE SITE AND SATISFY HIMSELF AS
TO LOCAL AND EXISTING CONDITIONS AS MAY AFFECT HIS WORK. HE WILL BE
DEEMED TO HAVE DONE THIS PRIOR TO PREPARATIONS OF PROPOSAL AND Sa1 b1 SWITCH
NO SUBSEQUENT CLAIM ON THE GROUND OF INADEQUATE INFORMATION
SHALL BE ENTERTAINED. S3a1 b1 3-WAY SWITCH
ALL MOUNTING HEIGHT SHOULD BE VERIFIED WITH THE ARCHITECT PRIOR TO
5 PANEL BOARD DIAGRAM
E.01 SCALE NTS
INSTALLATION.

ARCHITECT ARCHITECT'S SEAL RA 545, SEC. 25, PAR. 4 ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
These Drawings acting as
D&A instruments of service, are the
ARCHITECTURAL DESIGN property and documents of the
ARCHITECT. It shall be unlawful for
STUDIO any person, without the written PROPOSED TWO-STOREY LIGHTING LAYOUT
consent of the architect or author
RESIDENCE EXTENSION MS. FAITH EUNICE
09778437739
da.archlstudio@gmail.com
ALYSSA LYNN FRENCILLO-GIMENA, uap
of said documents, to duplicate or
to make copies of said documents
for use in the repetition of and for B11 L10, Camella Glenmont, PINGKIAN
POWER LAYOUT
GENERAL NOTES
SCHEDULE OF LOADS
E.01
other projects or buildings, Brgy. Sauyo, Q.C.
PRC NO. 32542 VALID UNITL: 3-19-2020 whether executed partly or in PRC NO. TIN:
whole.
PTR NO. 2301713 ISSUED: 01-28-2020, SJDM PTR NO. ISSUED:
CB CB
150MM Ø DP DS DS DS DS
WT HB
50MMØ VP FD 50MMØ VP 100MMØ SS GV P 20MM Ø CWL 25MM Ø CWR
CO 25MM Ø CWR
CO
FD CO WC SHO
LAV WC LAV FD LAV KS LAV WC SHO
S WC

100MMØ SS S KS

100MM Ø SP

150MM Ø DP

20MM Ø CWL
CB HB 20MM Ø CWL
150MM Ø DP
CB CB EXISTING DS DS HB
SEPTIC TANK
CV

M
DS
GV
FD

150MM Ø PVC DP TAP TO 25MM Ø CWL TAP TO EXISTING


EXISTING DRAINAGE LINE MAIN WATER SOURCE

1 GF SANITARY LAYOUT 2 2F SANITARY LAYOUT 3 ROOF DRAINAGE PLAN 4 GF WATER LINE LAYOUT 5 2F WATER LINE LAYOUT
P.01 SCALE 1:100 M P.01 SCALE 1:100 M P.01 SCALE 1:100 M P.01 SCALE 1:100 M P.01 SCALE 1:100 M

VST
R

DS
GENERAL NOTES LEGEND: 20M

LAV
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED IN ACCORDANCE W/ CW
WC L
THE PROVISIONS OF THE PHILIPPINE PLUMBING CODE, THE NATIONAL BUILDING CODE WATER LINE SHO
AND THE RULES AND REGULATIONS OF QUEZON CITY.
M WM WATER METER

25MM Ø CWR
2. COORDINATE THE DRAWINGS WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS. GV GATE VALVE

50MMØ VP
THE ENGINEER AND/OR THE ARCHITECTS SHALL NOTIFIED IMMEDIATELY OF ANY
DISCREPANCY FOUND HEREIN. DS
CV CHECK VALVE WT
DS GV P
3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATIONS REQUIRED FOR CWR / WATER RISER / LAV HB
PROPER EXECUTION OF THE PLUMBING WORKS SHALL BE WITH PRIOR APPROVAL OF THE CWDF DOWNFEED RISER WC GV
SHO GV
ENGINEER AND/OR THE ARCHITECTS.
CWL COLD WATER LINE
DS DS
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH CO
AND INVERT ELEVATIONS OF ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE P PUMP KS
LAV DS HB KS
CONTRACTOR. WC
20M
FD MØ
5. SLOPES FOR SANITARY DRAINAGE LINE SHALL MAINTAIN TWO PERCENT (2%) MINIMUM STORM DRAINAGE DS CW
L

100MMØ SS
RESPECTIVELY UNLESS OTHERWISE SPECIFIED.
L
CW

50MMØ VP
6. WATER SUPPLY PIPE TO FIXTURES SHALL BE SIZED IN ACCORDANCE WITH THE DP DRAIN PIPE Ø
20 MM
MANUFACTURER'S RECOMMENDATIONS. AD/CB AREA DRAIN/ CATCH BASIN
HB
7. ALL WATER PIPE SHALL BE THOROUGHLY FLUSHED AND DISINFECTED WITH LIQUID FD FLOOR DRAIN CV
CHLORINE OR HYPOCHLORITE SOLUTION. GV M
DS DOWNSPOUT 25M
CB M
MA Ø C
8. ALL WATER PIPES SHALL BE HYDROSTATICALLY TESTED TO AT LEAST 1-1/2 OF THE FD CO IN W W
DESIGNED WORKING PRESSURE OF THE SYSTEM. ATEL TAP
LAV CB R S TO
SEWER LINE WC FD 150
OUR EXI
CE STIN
9. ALL SANITARY AND STORM DRAINAGE PIPES SHALL BE HYDROSTATICALLY TESTED 100 FD MM G
SP SOIL PIPE MM ØD
TO AT LEAST 3.0 M. HEAD TO ENSURE THAT THE SYSTEM ARE WATER TIGHT. ØS P
S
WP WASTE PIPE CO
S
10. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES @ SITE AND COORDINATE
THE WORK WITH THE SEWER AND THE STORM DRAINAGE LINE EFFLUENT DISPOSAL POINT VSTR VENT STACK THRU ROOF
CB 150
S 8 WATER LINE ISOMETRIC
AND WATER LINE SERVICE CONNECTING / TAPPING POINT. M P P.01 SCALE NTS
VAC/ VP VENT ABOVE CEILING/ VENT PIPE MØ ØS
DP MM Ø DP
SS / VS SOIL STACK / VENT STACK 100
11. ALL PIPE SIZES AND OTHER DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS MM
150
OTHERWISE SPECIFIED. INDICATED PIPE SIZE SHALL BE CONSIDER AS THE INSIDE
DIAMETER.
CO CLEANOUT 6 AIR CHAMBER DETAILS CB

FD FLOOR DRAIN P.01 SCALE NTS SEP EXIS


TIC TING
12. WORKMANSHIP: THE WORK THROUGHOUT SHALL BE EXECUTED IN THE BEST AND TAN
K CB
MOST THOROUGH MANNER KNOWN TO TRADE AND TO THE SATISFACTION OF THE
ARCHITECT AND THE ENGINEER.
1
EXIS50MM
TIN Ø
7 AIR CHAMBER DETAILS
G D PVC P.01 SCALE NTS
RAI DP
NAG TA
E LI P TO
NE

ARCHITECT ARCHITECT'S SEAL RA 545, SEC. 25, PAR. 4 ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
These Drawings acting as
D&A instruments of service, are the
ARCHITECTURAL DESIGN property and documents of the
ARCHITECT. It shall be unlawful for
STUDIO any person, without the written PROPOSED TWO-STOREY SANITARY LAYOUT
consent of the architect or author
RESIDENCE EXTENSION MS. FAITH EUNICE
09778437739
da.archlstudio@gmail.com
ALYSSA LYNN FRENCILLO-GIMENA, uap
of said documents, to duplicate or
to make copies of said documents
for use in the repetition of and for B11 L10, Camella Glenmont, PINGKIAN
WATER LINE LAYOUT
GENERAL NOTES
ISOMETRIC
P.01
other projects or buildings, Brgy. Sauyo, Q.C.
PRC NO. 32542 VALID UNITL: 3-19-2020 whether executed partly or in PRC NO. TIN:
whole.
PTR NO. 2301713 ISSUED: 01-28-2020, SJDM PTR NO. ISSUED:
DESIGN CRITERIA & GENERAL NOTES : A B C A B C A B C
GUTTER
CODES: 50x75MM C-PURLINS
A. THE FOLLOWING CODES WERE USED IN THE DESIGN : @ 600MM O.C.
RB RB
ACI 318
50x75MM C-PURLINS

RB

RB
AISC C1-F1 C1-F1
FTB FTB @ 600MM O.C.
NATIONAL BUILDING CODE 1 EX
1 1
NATIONAL STRUCTURAL CODE B-1 B-1 10mmØ SAGRODS WITH STD. RB RB
STAIRWELL NUTS & WASHERS PER END NAT. GRADE LINE
NATIONAL SPECIFICATIONS FOR HIGHWAYS & BRIDGES AS ADOPTED WF

B-1

B-2
S-1 1 1/2" X 1 1/2" X 3/16"

FTB
BY DPWH AND DOTC

RB
T-2
ANGLE BAR RAFTERS 4" thk. CHB WALLS w/

RB
FTB

B-1

B-1
LATERAL LOADS V= CvIW/RT S-1
STEEL TRUSSED 10mmØ @ 0.60m O.C.

450
EACH WAY BARS
B. IN CASES OF CONFLICTING PROVISIONS FOR THE ABOVE CITED CODES,
C1-F1
ACI GOVERNS. B-2 10mmØ @ 0.30m O.C.
EXISTING RB T-7 RB

T-1

T-1
2 EX 2 EXISTING 2 TRANSVERSE BARS
FTB
LOADS: 100mm thk. SLAB ON GRADE

200
w/ 10mmØ @ 0.40m O.C. E.W. 3- 10mmØ LONGITU-
BARS. (SELECTED BACKFILL DINAL BARS
CONCRETE WEIGHT 24 KN/M³ WF MATERIALS LAID IN LAYERS OF

FTB

B-1

B-1

RB
-6 S-1
WOOD WEIGHT 9.5 X 10 KN/M/MM 300mm & COMPACTED TO 95% 400

T-3
STEEL WEIGHT 8.5 x 10³ Kg/M/MM OF MAXIMUM DRY DENSITY).

RB
T-4
MAXIMUM WIND VELOCITY 250 KPH C1-F1
WF
WATER WEIGHT 10 KN/M³ EX RB
OFFICE SPACE 2.40 KPa 3 FTB
3 B-1
3

T-6
T-5

T-5
CORRIDORS AND STAIRCASES 4.80 KPa
SOIL WEIGHT 20 KN/M³ RB 9 WALL FOOTING DETAIL
S-1

B-1

B-1
S.01 SCALE NTS
COMMERCIAL AREAS 4.80 KPa C1-F1 C1-F1
RESIDENTIAL AREAS 2.40 KPa
B-1 GUTTER

STRESSES:
A. CONCRETE CRUSHING CYLINDER STRENGTH f'c= 21 MPa @ 28 DAYS 1 FOUNDATION PLAN 2 2ND FLOOR FRAMING PLAN 3 ROOF FRAMING PLAN
B. STEEL MINIMUM YIELD STRENGTH S.01 SCALE NTS S.01 SCALE NTS S.01 SCALE NTS

fy = 230 MPa FOR DIAMETER < OR = 12 MM


fy = 275 MPa FOR 12 < DIAMETER BUT < OR = 20 MM.
fy = 414 MPa FOR DIAMETER > 20 MM
200 200 200 200
C. STEEL PLATES, BOLTS, ROLLED SHAPES AND ACCESSORIES SHALL BE 200
SUBJECT TO REQUIREMENTS OF ASTM A36. STEEL 200 200
200 200
6-16mmØ 4-16mmØ 4-16mmØ 3-16mmØ
A. ALL STRUCTURAL STEEL SECTIONS, ROLLED SHAPES AND PLATES SHALL CONFORM TO 6- 16mmØ
MISCELLANEOUS: THE REQUIREMENTS OF ASTM A 36 STEEL. VERTICAL
6- 16mmØ
VERTICAL BARS VERTICAL BARS VERTICAL BARS VERTICAL BARS
3-16mmØ 2-16mmØ
B. ALL STRUCTURAL STEELS SHAPES AND PLATES SHALL BE TRUE TO SIZE AS SPECIFIED ON BARS 6- 16mmØ 10mmØ 1@ 10mmØ 1@ 10mmØ 1@ 10mmØ 1@
A. CEMENT SHALL CONFORM TO ASTM C-150 TYPE 1 PORTLAND CEMENT. NO VERTICAL 0.05, 3@ 0.10, 0.05, 3@ 0.10, VERTICAL BARS VERTICAL BARS
SCHEDULES . THICKNESS VARIATION IS PERMITED ONLY TO NEGATIVE 0.3MM. VERTICAL BARS 0.05, 3@ 0.10, 0.05, 3@
POZZOLANIC CEMENT SHALL BE USED TO ANY OF THE STRUCTURAL BARS

400

400

400

400
REST @ 0.20m REST @ 0.20m 0.10, REST @ REST @ 0.20m 10mmØ 3@ 0.05, 5@ 10mmØ 3@ 0.05, 5@
C. ALL STRUCTURAL STEEL SHALL HAVE A SMOOTH, UNIFORM FINISH & SHALL BE

300

300
10mmØ 3@ 10mmØ 3@

400
MEMBERS. O.C. LATERAL O.C. LATERAL 0.20m O.C. O.C. LATERAL 0.10, REST @ 0.20m 0.10, REST @ 0.20m

350

350
STRAIGHTENED IN THE MILL BEFORE SHIPMENT. 10mmØ 1@ 0.05, 5@ 0.05, 5@ 0.10, TIES TIES LATERAL TIES TIES
B. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C-33. 0.05, 3@ O.C. LATERAL TIES O.C. LATERAL TIES
D. ALL STEEL SHALL BE FREE FROM LOOSE MILL SCALE, RUST PITS, CRACKS, FLAWS, SEAMS 0.10, REST @ REST @ 0.20m
C. WATER TO BE USED IN CONCRETE WORKS SHALL BE POTABLE. 0.10, REST 0.20m O.C. O.C. LATERAL 2-16mmØ 3-16mmØ
BLISTERS, IMPERFECT EDGES, OR ANY DEFECTS THAT WOULD IMPAIR ITS 4-16mmØ 6-16mmØ 3-16mmØ 4-16mmØ VERTICAL BARS VERTICAL BARS
D. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615/A616. @ 0.20m LATERAL TIES TIES VERTICAL BARS VERTICAL BARS VERTICAL BARS VERTICAL BARS
STRENGTH AND DURABILITY. O.C.
E. SPLICES SHALL BE DONE AT POINTS INDICATED IN THE DRAWINGS.
E. ALL BOLTS SHALL BE IN STRICT CONFORMITY TO THE REQUIREMENTS OF ASTM A307 LATERAL AT AT
F. FOUNDATIONS WERE DESIGNED FOR A SOIL BEARING PRESSURE OF 120 AT AT AT AT AT AT RB
(STRUCTURAL SPECICIFICATIONS FOR LOW CARBON STEEL EXTERNAL & INTERNAL TIES TB B-1 B-2 SUPPORT MIDSPAN
KPa. THE SITE ENGINEER SHALL INVESTIGATE AT THE BOTTOM OF C-1 SUPPORT MIDSPAN SUPPORT MIDSPAN SUPPORT MIDSPAN
TREADED STANDARD FASTENERS.)
FOOTINGS WHETHER THIS PRESSURE COULD BE ATTAINED OR NOT.
F. WELDING ELECTRODES SHALL CONFORM TO THE E60XX SERIES OF
G. ALL REINFORCEMENTS CAST AGAINST THE GROUND SHALL HAVE A 75MM
ASTM A233 ( STANDARDSPECIFICATIONS FOR MILD STEEL ARC WELDING ELECTRODES.)
NET COVER. FOR THOSE EXPOSED TO WEATHER, A MINIMUM OF 25 MM
G. TEST CERTIFICATES AS SUBMITTED BY THE MANUFACTURER SHALL BE A REQUIREMENTS
4 COLUMN & BEAM DETAILS
IS HOWEVER ALLOWED. S.01 SCALE NTS
H. NO FOOTING SHALL REST ON FILL. FOR EVERY SHIPMENT OF MATERIALS BEFORE USING THE SAME. SLAB TWO-WAY SLAB REINFORCEMENTS
H. THE CONTRACTOR SHALL IMMEDIATELY UPON THE REQUEST OF THE STRUCTURAL ENGINEER SLAB THICKNESS
I. ALL BARS SHALL BE BENT COLD. MARKS REMARKS
SAMPLE THE MATERIALS WHENEVER THERE IS REASONABLE DOUBT AS (MM) ALONG LONG SPAN ALONG SHORT SPAN
J. ALL REINFORCING BARS SHALL BE SPLICED ONLY AT POINTS INDICATED
IN THE DRAWINGS. UNDER NO CIRCUMSTANCES WILL THEY BE SPLICED TO THE REQUIREMENTS OF THE MEMBER OR ITS COMPONENTS. ALL COSTS INCURRED 4.10 4.10 4.10 5.25 FLOOR SLAB
Ø12 @ 150
AT POINTS OF CRITICAL STRESSES. IN THE SAMPLING AND TESTING SHALL BE BORNE BY THE CONTRACTOR. 0.35 0.40
0.60 1.10 1.20 1.20 1.20 1.20 1.35 0.60 1.10 1.20 1.20 1.20 1.20 1.20 1.25 Ø12 @ 250 S-1 100 10Ø @ 150 O.C. 10Ø @ 120 O.C. EXTRA BAR @200 L/4
K. REINFORCEMENT RUNNING ALONG SHORT DIRECTION SHALL BE LAID ON I. THE CONTRACTOR SHALL FURNISH ALL THE FACILITIES FOR INSPECTION OF MATERIALS AND TOP & BOT. 3-Ø16
BARS TOP BARS
THE LOWER LAYER AS AGAINST THOSE RUNNING ALONG LONG WORKMANSHIP IN THE SITE (MILLING AND FABRICATION) AND THE DESIGNATED INSPECTOR
SLAB SCHEDULE

150
LANDING 7
DIRECTION. SHALL BE ALLOWED FREE ACCESS TO THE NECESSARY PARTS OF THE PREMISES. THE LEVEL
1.65

1 1 1 1 S.01 SCALE NTS


L. OVER ALL DOOR AND WINDOW OPENINGS SHALL BE A LINTEL BEAM NO INSPECTOR SHALL HAVE THE POWER TO REJECT MATERIALS AND WORKMANSHIP NOT 2 2 2 2 2 2 2 Ø12 @ 150
2 2 2 2 2 2 2

400
FULFILLING SPECIFICATION REQUIREMENTS. 2 2
LESS THAN 150 MM X 300 MM IN SIZE WITH 2-12MMØ TOP AND 2 2 2 2
2-12 MMØ BOTTOM BARS CLIPPED TOGETHER BY 10 MMØ STIRRUPS J. TO ALL BOLT HEADS AND NUTS SHALL BE A FITTING WASHER. 1 1 4
L/ FINISH FLOOR LINE
K. ALL WELDING WORKS SHALL BE DONE BY COMPETENT WELDERS ONLY OR BY OPERATORS T-1 T-2 3-Ø16
SPACED NOT MORE THAN 200 MM O.C. BOT. BARS
WHO HAVE PASSED THE QUALIFICATION TEST TO THE SATISFACTION OF THE STRUCTURAL

450
M. ADJACENT SLABS WITH DIFFERENT REINFORCEMENTS SHALL ADOPT 5.65 6.60

15
Ø10 NOSING BAR
ENGINEER. ALL WELDERS SHALL BE CERTIFIED WELDERS. SUBMIT CERTIFICATION FOR EACH

0
THE CLOSER OF THE TWO COMMON BARS. 0.50 0.55
PRIOR TO DEPLOYMENT AT SITE. 1.65 1.70 1.80 1.45 1.50 1.50 1.55 NAT. GRADE LINE
N. WHERE A MASONRY WALL EXCEEDS A LENGTH OF 6.00 M., IT SHALL BE 150
L. BEFORE WELDING OVER PREVIOUSLY DEPOSITED METAL, THE SLAG SHALL BE REMOVED AND 2.40 L
INTERCEPTED & STIFFENED BY A STIFFENER COLUMN NO LESS THAN 1.20 1.20 Ø12 @ 150 Ø12 @ 300
THE WELD AND ADJACENT BASE METAL SHALL BE BRUSHED CLEAN. PRE-HEAT IF NECESSARY.
1.65

1.65

150 MM x 400 MM IN DIMENSIONS REINFORCED BY 6-16MMØ LONGITUDINAL 1 1 1 1 Ø10 @ 300 Ø12 @ 150
M. ALL STRUCTURAL STEEL SHALL BE GIVEN TWO (2) COATS OF ZINC CHROMATE PRIMER 2 2 2
2 2

1000
BARS & CLIPPED TOGETHER BY 10MMMØ 1@ 0.05, 3@ 0.10, REST @ 0.20 TEMP. BARS
1 /4

0.60
2 2

1000
YELLOW OR EQUIVALENT RUST - INHIBITIVE PAINT DULY APPROVED BY THE STRUCTURAL 2 2 2 1 2 FFL L COLUMN (SEE DETAIL)
M. O.C. TIES. SUCH STIFFENER COLUMMN SHALL BE PLACED UNLESS OTHER- 2
ENGINEER BEFORE LEAVING THE PLANT. 1 1 1
WISE NOTED ON DRAWINGS.

800
N. FINAL PAINTING SHALL BE DONE ONLY WHEN MEMBERS SHALL HAVE T-3 T-4 T-5 Ø12 @ 150

1000
O. WHERE A MASONRY WALL EXCEEDS A HEIGHT OF 3.50 M., IT SHALL BE 200 VERT. BARS E.F. 9- 16mmØ BOTHWAYS
BEEN IN FINAL PLACE PER PAINTING SCHEDULE SUPPLIED BY THE ARCHITECT. 7.55
STIFFENED BY A STIFFENER BEAM NO LESS THAN 200 MM x 450 MM IN 3-Ø10 LONG.

200
IN NO CASE WILL THE FINAL PAINT BE LESS THAN TWO COATS OF EPOXY 1.25 1.25 1.25 1.25 1.25 1.25

350
BARS
DIMENSIONS REINFORCED BY 4-16MMØ LONGITUDINAL BARS AND CLIPPED
AUTOMOTIVE PAINT, THE COLOR OF WHICH SHALL BE APPROVED 1.90 Ø12 @ 250
TOGETHER BY 10MMMØ 1@ 0.05, 3@ 0.10, REST @ 0.20 M. O.C. STIRRUPS. 1 100mm THK. WELL-
BY THE ARCHITECT AND THE OWNER. 0.95 0.95 NOTE: TRANS BARS
SUCH STIFFENER BEAM SHALL BE PLACED UNLESS OTHERWISE NOTED COMPACTED GRAVEL
1.65

1 1 2 2 2 2 2 2 2 2 2 2 2 1 1 = 2-1/4x2x2 ANGLE BAR


BASE 500
1000 1000
ON DRAWINGS. 2 = 1-1/4x11/2x11/2 ANGLE BAR
0.60

2 2 2
1 1
P. WHETHER DETAILED ON DRAWINGS OR NOT, ALL SLAB ON GRADE SHALL BE
BEDDED ON 100 MM THICK GRAVEL BEDDING WITH MATCHING TWO-PLY
1 1 PLAN SECTION
T-6 T-7
POLYETHYLENE VAPOR BARRIER SHEETING.
Q. STIRRUPS AND TIES SPACINGS ON SCHEDULES ARE REFERRED FROM EACH
5 TRUSS DETAILS 6 TYP. STAIR SECTION DETAILS 8 COLUMN FOOTING DETAILS
S.01 SCALE NTS S.01 SCALE NTS S.01 SCALE NTS
SUPPORT FOR BEAMS AND EACH END PER STOREY FOR COLUMNS.

ARCHITECT ARCHITECT'S SEAL RA 545, SEC. 25, PAR. 4 ENGINEER PROJECT TITLE OWNER SHEET CONTENTS SHEET NO.
These Drawings acting as
D&A instruments of service, are the
ARCHITECTURAL DESIGN property and documents of the
ARCHITECT. It shall be unlawful for
STUDIO any person, without the written PROPOSED TWO-STOREY FOUNDATION PLAN
consent of the architect or author
RESIDENCE MR. ERNEST JOHN SECOND FLOOR FRAMING PLAN
09778437739
da.archlstudio@gmail.com
ALYSSA LYNN FRENCILLO-GIMENA, uap
of said documents, to duplicate or
to make copies of said documents
for use in the repetition of and for
ENGR. MELCHOR G. LAGMAY Blk 7 Lot 12 Highview Royale, RAGASA
ROOF FRAMING PLAN
DETAILS
S.01
other projects or buildings, GENERAL NOTES
San Jose del Monte, Bulacan
PRC NO. 32542 VALID UNITL: 3-19-2020 whether executed partly or in PRC NO. 0128160 TIN: 428-687-978
whole.
PTR NO. 7507856 C ISSUED: 01-21-19, Q.C. PTR NO. 6737104 ISSUED: 1-29-19,ANTIPOLO

Вам также может понравиться