Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static
Profile:
Pile Length, L= 56.0 -m
Top Height, H= 12 -m
Slope Angle, As= 0
Batter Angle, Ab= -9.5
Vertical capacity:
Weight above Ground= 42.70 Total Weight= -134.74-kN *Soil Weight is not included
Side Resistance (Down)= 10131.236-kN Side Resistance (Up)= 9111.970-kN
Tip Resistance (Down)= 4864.390-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 14995.626-kN Total Ultimate Capacity (Up)= 8977.227-kN
Total Allowable Capacity (Down)= 9186.353-kN Total Allowable Capacity (Up)= 4421.242-kN
OK! Qallow > Q
Settlement Calculation:
At Q= 4698.00-kN Settlement= 1.20979-cm
At Xallow= 2.50-cm Qallow= 8988.94531-kN
Note: If the program cannot find a result or the result exceeds the upper limit. The result will be displayed as 9999.