Вы находитесь на странице: 1из 2

Name G90-8.5-50 G110-8.5-50 G132-8.5-50 G160-8.5-50 G90-8.5-50 G110-8.5-50 G132-8.5-50 G160-8.

5-50
Template
Special Serial Number
Document Number 9096518910 9096518910 9096518910 9096518910 9096518910 9096518910 9096518910 9096518910
Document Revision 00 00 00 00 00 00 00 00
Order/Page
Replaces document number
Modified from
Company Atlas Copco India Atlas Copco India Atlas Copco India Atlas Copco India Atlas Copco India Atlas Copco India Atlas Copco India Atlas Copco India
Author Data Import Data Import Data Import Data Import Data Import Data Import Data Import Data Import
Status Released on Released on Released on Released on Released on Released on Released on Released on 20/07/2011
20/07/2011 20/07/2011 20/07/2011 20/07/2011 20/07/2011 20/07/2011 20/07/2011
Created on 15/07/2011 15/07/2011 15/07/2011 15/07/2011 15/07/2011 15/07/2011 15/07/2011 15/07/2011
Product Definition Model G 90 G 110 G 132 G 160 G 90W G 110W G 132W G 160W
Teflon-free elements (TEFLO) Yes (Y) Yes (Y) Yes (Y) Yes (Y) Yes (Y) Yes (Y) Yes (Y) Yes (Y)

Cooling (COOL) Air cooled (AIR) Air cooled (AIR) Air cooled (AIR) Air cooled (AIR) Water cooled (W) Water cooled (W) Water cooled (W) Water cooled (W)
frequency (FREQ) 50 Hz (50HZ) 50 Hz (50HZ) 50 Hz (50HZ) 50 Hz (50HZ) 50 Hz (50HZ) 50 Hz (50HZ) 50 Hz (50HZ) 50 Hz (50HZ)
Integrated dryer (IDRY) Pack (PACK) Pack (PACK) Pack (PACK) Pack (PACK) Pack (PACK) Pack (PACK) Pack (PACK) Pack (PACK)
Maximum working pressure 8.5 bar (8.5BAR) 8.5 bar (8.5BAR) 8.5 bar (8.5BAR) 8.5 bar (8.5BAR) 8.5 bar (8.5BAR) 8.5 bar (8.5BAR) 8.5 bar (8.5BAR) 8.5 bar (8.5BAR)
(PRESS)
DD filter (DDFIL)

A REFERENCE CONDITIONS
1 Absolute inlet pressure (bar(a)) 1 1 1 1 1 1 1 1
2 Relative humidity (%) 0 0 0 0 0 0 0 0
3 Air inlet temperature (°C) 20 20 20 20 20 20 20 20
5 Effective working pressure (bar(g)) 8 8 8 8 8 8 8 8
4 Cooling medium Inlet (water or air) temperature (°C) 20 20 20 20 20 20 20 20
7 Motor shaft speed (rpm) 1485 1485 1485 1485 1485 1485 1485 1485

B LIMITATIONS
1 Minimum ambient temperature (°C) 0 0 0 0 0 0 0 0
2 Maximum air inlet temperature (°C) 46 46 46 46 46 46 46 46
6 Minimum effective working pressure (bar(g)) 4 4 4 4 4 4 4 4
7 Maximum effective working pressure (bar(g)) 8.5 8.5 8.5 8.5 8.5 8.5 8.5 8.5
9 Maximum cooling medium inlet open circuit temperature (°C) 46 46 46 46 40 40 40 40
10 Maximum cooling medium inlet closed circuit temperature (°C) 46 46 46 46 40 40 40 40
8 Minimum cooling medium inlet temperature (°C) 0 0 0 0 0 0 0 0
3 Maximum air inlet temperature arrg. 1 (°C) 46 46 46 46 46 46 46 46
Maximum effective cooling water inlet pressure (bar) 10 10 10 10

C PERFORMANCE DATA (1)


1 Free air delivery (l/s) (3)
5 Effective working pressure (bar(g)) 4 267 316 383 485 267 316 383 485
5 Effective working pressure (bar(g)) 5 266 317 383 485 266 317 383 485
5 Effective working pressure (bar(g)) 6 265 315 382 484 265 315 382 484
5 Effective working pressure (bar(g)) 7 264 314 381 483 264 314 381 483
5 Effective working pressure (bar(g)) 8 263 313 381 482 263 313 381 482
5 Effective working pressure (bar(g)) 8.5 262 313 379 482 262 313 379 482
2 Main shaft power (kW)
5 Effective working pressure (bar(g)) 4 73 89 106 137 73 89 106 137
5 Effective working pressure (bar(g)) 5 78 95 112 146 78 95 112 146
5 Effective working pressure (bar(g)) 6 84 101 119 154 84 101 119 154
5 Effective working pressure (bar(g)) 7 89 107 127 163 89 107 127 163
5 Effective working pressure (bar(g)) 8 95 114 134 172 95 114 134 172
5 Effective working pressure (bar(g)) 8.5 98 117 138 177 98 117 138 177
3 Specific main shaft requirement (J/l) (9)
5 Effective working pressure (bar(g)) 4 272 280 277 283 272 280 277 283
5 Effective working pressure (bar(g)) 5 291 299 294 301 291 299 294 301
5 Effective working pressure (bar(g)) 6 315 323 313 318 315 323 313 318
5 Effective working pressure (bar(g)) 7 335 343 334 338 335 343 334 338

1/2
5 Effective working pressure (bar(g)) 8 359 365 353 357 359 365 353 357
5 Effective working pressure (bar(g)) 8.5 372 375 365 367 372 375 365 367
4 Main shaft power at unload (kW) (20) 24 28 32 38 22 28 30 36
5 Total electrical power input (kW) (10)
5 Effective working pressure (bar(g)) 4 80 97 117 151 77 94 112 145
5 Effective working pressure (bar(g)) 5 85 103 124 160 83 100 119 155
5 Effective working pressure (bar(g)) 6 91 110 131 168 89 108 127 163
5 Effective working pressure (bar(g)) 7 97 117 139 178 94 114 135 173
5 Effective working pressure (bar(g)) 8 103 124 147 187 100 121 142 182
5 Effective working pressure (bar(g)) 8.5 106 127 151 192 103 124 146 187
6 Total specific energy requirement (J/l) (9)(10)
5 Effective working pressure (bar(g)) 4 299 306 305 310 289 298 293 299
5 Effective working pressure (bar(g)) 5 320 325 323 330 310 317 311 319
5 Effective working pressure (bar(g)) 6 345 351 343 348 335 342 331 337
5 Effective working pressure (bar(g)) 7 366 372 366 368 356 363 354 357
5 Effective working pressure (bar(g)) 8 391 396 385 388 381 387 373 377
5 Effective working pressure (bar(g)) 8.5 405 406 398 399 394 398 386 388
7 Total electrical power input at unload (kW) (10)(20) 27 31 37 44 23 29 31 37
10 Compressed air temperature at outlet valve (°C) 28 28 28 29 25 25 25 25
13 Fan(s) shaft power (kW) 3 3 5 5 0.27 0.27 0.27 0.27
14 Fan(s) electrical power input (kW) 3.5 3.5 5.4 6 0.83 0.83 0.83 0.83
17 Pressure dewpoint air outlet (°C)
18 Typical oil content of compressed air (mg/m³) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
30 Mean sound pressure level (dB(A)) (18) 78 78 78 78 76 76 76 76

D DESIGN DATA
4 Drive motor installed power (kW) 90 110 132 160 90 110 132 160
5 Drive motor name EHXF280SMC4 ABB M2BAF315SMA4 M2BAF315SMB4 M2BAF315MLA4 EHXF280SMC4 ABB M2BAF315SMA4 M2BAF315SMB4 M2BAF315MLA4 ABB
ABB ABB ABB ABB ABB
8 Fan motor name LHP LHP LHP LHP LHP LHP LHP LHP
9 Number of compression stages 1 1 1 1 1 1 1 1
10 Bull gear number of teeth 66 67 49 74 66 67 49 74
11 Pinion first stage number of teeth 30 26 34 41 30 26 34 41
12 Pinion second stage number of teeth
16 Oil capacity (approx.) (l) 60 70 80 90 55 55 78 78
23 Unit length (m) 2.779 2.779 2.779 2.779 2.779 2.779 2.779 2.779
24 Unit height (m) 2.005 2.005 2.005 2.005 2.005 2.005 2.005 2.005
25 Unit width (m) 1.72 1.72 1.966 1.966 1.72 1.72 1.966 1.966
26 Unit volume (m³) 9.6 9.6 11.0 11.0 9.6 9.6 11.0 11.0
31 Unit mass (kg) 2700 2900 3500 3550 2500 2800 3400 3450
39 Cooling air flow referred to air inlet grating compressor (m³/s) 3.7 3.7 5.25 5.94
73 Integrated dryer type
132 Male rotor speed stage 1 (rpm) 3267 3827 2140 2680 3267 3827 2140 2680
137 Number of compression elements 1 1 1 1 1 1 1 1

O REMARKS (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20) (1)(3)(9)(10)(18)(20)


1 C At reference conditions, unless otherwise stated and according to ISO 1217, third edition, annex C.
3 C1 Corresponds to 'Actual Volume Flow Rate' (ISO 1217, third edition, annex C).
Measured according ISO 5167-2.
Guaranteed with a tolerance of +/- 4% for units with a Volume Flow rate above 250 litres per second.
Guaranteed with a tolerance of +/- 5% for units with a Volume Flow rate from 25 to 250 litres per second.
9 C3;C6 Guaranteed with a tolerance of +/- 5% for units with a Volume Flow rate above 250 litres per second. (ISO 1217, third edition)
Guaranteed with a tolerance of +/- 6% for units with a Volume Flow rate from 25 to 250 litres per second.(ISO 1217, third edition)
10 C5;C6;C7 Supply voltage 400 V (for 50 Hz units); 440V (for 60 Hz units). Data may differ 0.5% maximum at other supply voltages.
18 C16;C30 A-weighted emission sound pressure level at the work station (LpWSAd)
Measured according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method)
A total correction factor for uncertainties of 3 dB has to be added conform the test code.
Possible noise from discharge line, accessories and/or anncillary equipment is not included.
For more information about noise levels, see printed matter 9780 0380 10, "Compressed Air Manual 1998", Section 3.9.
20 C4;C7 Guaranteed with a tolerance of +/- 20%.

2/2

Вам также может понравиться