Road Detail
Type of Road: # B-1
Design Vehicle Speed for Road 50 Km/Hr Km/Hr
Width of the road (W): # 7 Meter
Type of Pole Arrangement (F): # Single side 1
Height of the pole (H): 6 Meter
Luminaire Detail:
Type of fixture: Full Cutoff
Type of Lamp: LED
Rated Fixture Power: 92 Watt
Lamp Lumen Output (LL): # 9200 Lumens
Lux Required on Road: (Eh) # 10 Lux
Mounting Height of Fixture (H): # 6 Meter
Pole distance from Road (SetBack) (C): 0.5 Meter
Light OverHang (B): 0.5 Meter
Boom Length (L): 1 Meter
Boom Angle (Tilt Angle) (¢): 10 °
Beam Angle of Fixtures: # 120 °
Coefficient of utilization (CU) 0.2
Lamp Lumen Depreciation Factor (LLD) 0.72
Luminaire dirt Depreciation Factor (LDD) 0.88
Results:
Spacing between each Pole: 17 Meter
Space Height Ratio: 3
Illumination Diameter on Road: 13 Meter
Equations:
Spacing between each Pole=(LL*CU*LLD*LDD*F) / Eh*W
# Details Required
o of Street Light Pole Jignesh.N.Parmar www.electricalnote
Equations:
Spacing between each Pole=(LL*CU*LLD*LDD*F) / Eh*W
& Luminaries Watt Jignesh.N.Parmar www.electricalnotes.wordpress.com
Luminaire Detail:
Required Illumination Level for Street Light 6.46 Lux per Sq.Meter
luminous efficacy 24 Lumen/Watt
Area Detail:
Surface Area 1 Sq.Meter
OR
Spherical Radius 6 Meter 452.16
Relation
Width of road
Mounting Height
Mounting Height
luminaire arrangement
Single side
8 Meter Staggered
Opposite
Single side
10 Meter Staggered
Opposite
Single side
12 Meter Staggered
Opposite
Lighting levels
Category Eave ( lx )
Maintenance factors
Pollution category
Cleaning intervals (months)
High
12 0.53
18 0.48
24 0.45
36 0.42
Lengths of projection
Nominal height (m) Projection (Meter)
4, 5, 6, 8, 10, 12, 15, 18 0.75 /1.25 / 2 / 3
Maintenance f
IP5X
Pollution category
Low
LMF 0.88
LLMF 0.89
MF 0.78
LDD
Outdoor Industrial 0.71
Indoor-Non Industrial 0.86
Indoor Industrial 0.79
Outdoor Residential 0.77
Recommended Levels of Illumination (BIS 1981) (IS 1944)
Average Level of
Road Width (Meter) Illumination on Road
Surface in Lux
>10.5,12,14,16,18,20,30 30
> 7 m up to 10 m 15
Lighting levels
Uniformity ratios
Emin ( lx )
Emax : Emin
15 3:01
10 5:01
10 5:01
5 10:01
ance factors
Pollution category
Medium Low
0.62 0.82
0.58 0.8
0.56 0.79
0.53 0.78
le
e Utilisation Factor
Average
0.53
0.48
0.43
0.4
0.28
0.15
n (BIS 1981) (IS 1944)
Ratio of Minimum/Average Ratio of Minimum/Max
Type of Luminaire Preferred
Illumination Illumination
0.4 33 Cutoff
0.4 33 Cutoff
Uniformity ratios
Eave : Emin
2.5:1
3:01
3:01
5:01
ing interval
IP6X
Pollution category
Low Medium High
0.9 0.87 0.83
0.89 0.89 0.89
0.80 0.77 0.74
Luminar
Mounting Height
9 To 10 Meter
9 To 10 Meter
7.5 To 9 Meter
7.5 To 9 Meter
er to 14 Meter
Semi cutoff type
-
-
-
-
-
35
-
42
48