Вы находитесь на странице: 1из 6

:Calculate Size of Ventilation Fan: (As per CPWD)

Type of Room: Toilets - Domestic


Length of Room: 4
Width of Room: 8
Height of Room: 3
Size of Room 96
Fresh Air Exchanges Rate in Room: 8
Required Size of Ventilation Fan: 768
13
22
Size of Ventilation Fan: 200 / 8"
Sound Level: 44 To 50

Recommended Air Change Rates For Room (ACH) (As per CPWD)
Type of Room Air Change Rate / Hour
Shower Area 15 To 20
Bathroom & Shower Rooms 15 To 20
Bathroom 6 To 10
Bedrooms 2 To 4
Halls & Landings 4 To 6
Kitchens 10 To 20
Living & Other Domestic Rooms 4 To 6
Toilets - Domestic 6 To 10
Utility Rooms 15 To 20
Cafés 10 To 15
Canteens 8 To 12
Cellars 3 To 10
Changing Rooms with Showers 15 To 20
Conference Rooms 8 To 12
Garages 6 To 10
Hairdressing Salons 10 To 15
Hospital Wards 6 To 8
Laundries & Launderettes 10 To 15
Meeting Rooms 6 To 12
Offices 4 To 6
Restaurants & Bars 10 To 15
School Rooms 5 To 7
Shops 8 To 10
Sports Facilities 4 To 6
Store Rooms 3 To 6
Workshops 6 To 10
Assembly rooms 4 To 8
Bakeries 20 To 30
Banks/Building Societies 4 To 8
Billiard Rooms * 6 To 8
Boiler Rooms 15 To 30
Canteens 8 To 12
Changing Rooms Main area 6 To 10
Changing Rooms Shower area 15 To 20
Churches 1 To 3
Cinemas and theatres * 10 To 15
Club rooms 0 To 12
Compressor rooms 10 To 15
Conference rooms 8 To 12
Dairies 8 To 10
Dance halls 0.12
Dental surgeries 12 To 15
Dye works 20 - 30
Electroplating shops 10 To 12
Engine rooms 15 To 30
Entrance halls & corridors 3 To 5
Factories and workshops 8 To 10
Foundries 15 To 30
Glasshouses 25 To 60
Gymnasiums 0 To 6
Hospitals - Sterilising 15 To 25
Kitchens - Domestic 15 To 20
Kitchens - Commercial 0 To 3
Laboratories 6 To 15
Lavatories 6 To 15
Lecture theatres 5 To 8
Libraries 3 To 5
Mushroom houses 6 To 10
Paint shops (not cellulose) 10 To 20
Photo & X-ray darkrooms 10 To 15
Public house bars 0 To 12
Recording control rooms 15 To 25
Recording studios 10 To 12
Shops and supermarkets 8 To 15
Squash courts 0.04
Swimming baths 10 To 15
Welding shops 15 To 30
Standard Exhaust Fan Size
M3/HR   (CFH) M3/MI   (CFM)

270 5
500 8
800 13
1710 29
1145 19
3250 54
3250 54
2000 33
2000 33
6120 102
6120 102
3900 65
3900 65
7100 118
7100 118
9400 157
9400 157
12000 200
12000 200
28100 468
n: (As per CPWD) Jignesh.Parmar www.electricalnotes.wordpress.com

Feet
Feet
Feet
Cubic Feet
Times per Hour
Cubic Foot / Hour (CFH)
Cubic Foot / Minute (CFM)
Cubic Meter / Hour (CMH)
mm / inch
DB

om (ACH) (As per CPWD)


Consider
20
15
8
4
5
15
5
8
15
15
10
6
15
8
8
13
7
13
7
6
12
6
9
6
5
8
8
25
5
5
25
10
8
17
3
12
12
15
12
10
0.12
15
30
12
30
5
10
20
50
6
20
15
3
12
12
8
4
8
15
12
12
20
10
12
0.04
12
20
Standard Exhaust Fan Size
Fan DIA
Speed Input Current
Sound level dB (MM / Phase
(RPM) Power (W) (A)
inches)
44 To 50 150 / 6" 1200 24 Single 0.1
44 To 50 200 / 8" 1350 28 Single 0.12
44 To 50 250 / 10" 1350 36 Single 0.15
50 To 55 305 / 12" 1400 50 Single 0.4
35 To 40 305 / 12" 900 50 Single 0.21
60 To 65 380 / 15" 1400 160 Single 0.75
60 To 65 380 / 15" 1400 150 Three 0.45
50 To 55 380 / 15" 900 90 Single 0.4
50 To 55 380 / 15" 900 100 Three 0.29
65 To 70 457 / 18" 1400 410 Single 1.7
65 To 70 457 / 18" 1400 410 Three 0.65
55 To 60 457 / 18" 900 150 Single 0.65
55 To 60 457 / 18" 900 150 Three 0.3
55 To 60 610 / 24" 700 240 Single 0.4
55 To 60 610 / 24" 900 500 Three 0.5
60 To 65 610 / 24" 900 500 Single 2.6
60 To 65 610 / 24" 900 500 Three 0.85
70 To 75 750 / 30" 900 870 Single 3.8
70 To 75 750 / 30" 900 910 Three 1.8
75 To 80 900 / 36" 700 1200 Three 2.4