Lung Link: Improved Artificial Lung Conduits

Clinical Problem
Methods
Conclusions



•  Lung Disease takes nearly 335,000 lives each •  A PVDF coating is inferior to PVC in terms of
Area of Need
Experimentation Method

Description

year in the Unites States alone and is a mechanical strength.

growing problem [1].
Tube Kinking
Comparative Study of
Compare effects of applied
Mechanical Strength

forces to coated PVC and •  Thin Rayon Polyester Blend is a superior
•  The waiting list for lung transplants contains material for wrapping the conduit due to
thousands of people, and most patients have to PVDF grafts.

Tissue In-Growth
Live/Dead Assay: Cell Determine cell viability after increased tissue viability and proliferation.

wait 1-2 years to find a suitable donor [2].

Viability Test of Materials
72 hours on varying proposed •  A Colder quick-connect device will allow for
•  A new artificial and portable assistance device easy replacement of the gas exchanger without
for the lung would aid extend patients lives materials.

introducing any increased thrombosis risk.

until a donor organ is available.
Gas Exchanger Liquid Flow; Connection to Determine flow capability
•  Future work will include animal testing to
•  Currently, Dr. Keith Cook and team have Connection
Exchanger
through Quick-Connection.

determine the conduit’s in vivo functionality
designed a prototype to fit this need.
and testing additional coating materials.

Description of Design
Results
Prototype Design

PVC  Coated  GraBs   PVDF  Coated  GraBs  


0.16   0.16  
0.14   0.14  
0.12   0.12  
Load  (kN)  

0.1  

Load  (kN)  
0.1  
0.08   0.08  
0.06   0.06  
0.04   0.04  
0.02   0.02  


0   0  

-­‐0.02  
0   5   10   15   20  
-­‐0.02  
0   5   10   15   20  

The areas of concern of previous prototype Displacement  (mm)   Displacement  (mm)  


improved in current prototype are:



Tube Kinking: Polyvinyl chloride (PVC)
currently coats the graft material attaching to the
heart improving mechanical strength. PVDF was
tested as an alternative and proved ineffective.
Acknowledgements


Our group would like to thank Dr. Keith Cook and David
Skoog for offering so much help and advice in completing
Tissue In-Growth: Thin porous rayon-polyester our project. Additionally, thanks to Dr. Zapanta and Krista
blend material is sewn to the conduit at the exit of Rochussen for their continued support in this course.

"
the body replacing the previous felt material.



Figure 1: Live/ Dead Assay Results including previous prototype’s Felt (Left)
Gas Exchanger Connection: A quick-connection and Thin Rayon Polyester Blend (Right). Cells stained green are living, while References

system is implemented at the distal end of the cells stained red are dead. Image analysis showed that the Thin Rayon [1] “Estimated Prevalence and Incidence of Lung Disease (April
conduit for a quick and easy replacement of the 2013).” American Lung Association.

Polyester Blend resulted in the highest cell viability. [2] “Transplant Waiting List.” Stanford Hospital & Clinics. Stanford
gas exchanger portion." University, 2014. Web. 05 May 2014.