121. In a parallel RLC circuit if the lower cut-off frequency is 2400 Hz and the
upper cut-off frequency is 2800 Hz what is the bandwidth?
(a) 400 Hz
(b) 2400 Hz
(c) 2800 Hz
(d) 5200 Hz
126. Which instrument is used to measure the high resistance?
127.
The voltage across the 1 k resistor of the network shown in the given figure
is
(a) 6 V (b) 4 V
(c) 2 V (d) 1 V
137.
42. A current i = (10 + 10 sin t) amperes is passed through moving iron type
ammeter. Its reading will be
(a) zero (b) 10 A
(c) √150A (d) √2A
55. Two heaters rated at 1000 W, 250 V each are connected in series across a
250 V, 50 Hz AC mains. The total power drawn from the supply would be
(a) 1000 watt (b) 500 watt
(c) 250 watt (d) 2000 watt
Ans: a
Ans: b
6. If a 500 KVA, 200 Hz transformer is operated at 50 Hz, its KVA rating will
be
(a) 2000 KVA (b) 125 KVA
(c) 250 KVA (d) 1000 KVA
7. The angle between induced emf and terminal voltage on no-load for a single
phase alternator is
(a) 180° (b) 90°
(c) 0° (d) 270°
13. If four 10F capacitors are connected in parallel, the net capacitance is
(a) (b)
(c) (d)
25. A transformer is working at its full load and its efficiency is also
maximum. The iron loss is 1000 watts. Then, its copper loss at half of full load
will be
(a) 250 watt (b) 300 watt
(c) 400 watt (d) 500 watt
5 a 13 b 34 b
6 a 19 d 47 b
9 d 25 a 32 a
1. If in an R-L-C series circuit the current lags the applied voltage by 60° then
10. The ratio of the reading of two wattmeter’s connected to measure active
power in a balanced 3-phase load is 2: 1. The power factor of the load is
(a) 0.866 lag
(b) 0.866 lead
(c) 0.866 lag or lead
(d) None of the above
22. A 40 kVA transformer has a core loss of 400 W and full load copper loss of
800 W. The fraction of rated load at maximum efficiency is
(a) 50% (b) 62.3%
(c) 70.7% (d) 100%
19. A 100 kVA single phase transformer exhibits maximum efficiency at 80%
of full load and the total loss in the transform under this condition is 1000 W.
The ohmic losses at full load will be
(a) 781.25 watt (b) 1250 watt
(c) 1562.5 watt (d) 12500 watt
ANSWER 2011
1. The voltage wave v = Vm sin (t – 15°) volts is applied across an AC circuit.
If the current leads the voltage by 10° and the maximum value of currents is
Im, then the equation of current is
(a) i = Im sin (t + 5°) amps
(b) i = Im sin (t – 25°) amps
(c) i = Im sin (t + 25°) amps
(d) i = Im sin (t – 5°) amps
2. The average value of current (Iav) of a sinusoidal wave of peak value (Im) is
11. Phasor diagram of load voltage (V), current in pressure coil (Ip) and
current in current coil (IC) is shown in the figure when an electrodynamic
wattmeter is used to measure power. The reading of the wattmeter will be
proportional to
(a) cos() (b) cos
(c) coscos (d) coscos ()
15. A balanced 3-phase, 3-wire supply feeds balanced star connected resistors.
If one of the resistors is disconnected, then the percentage reduction in load
will be
(a) 33.33 (b) 50
(c) 66.67 (d) 75
32. A wattmeter is marked 15A/30A, 300V/600V and its scale is marked up to
4500 watts. When the meter is connected for 30A, 600A, the point indicated
2000 watts. The actual power in the circuit is
(a) 2000 watts (b) 4000 watts
(c) 6000 watts (d) 8000 watts
36. In a balanced 3-phase circuit, the line current is 12A. When the power is
measured by two wattmeter
method, one meter reads 11kW while the other reads zero. Power factor of the
load is
(a) 0 (b) 0.5
(c) 0.866 (d) 1.0
54. In a series R-L circuit supplied from an sinusoidal voltage source, voltage
across R and L are 3 V and 4 V respectively. The supply voltage is then
(a) 7 V (b) 1 V
(c) 3.5 V (d) 5
57. Two 2000 , 2 watt resistors are connected in parallel. Their combined
resistance value and wattage rating are
(a) 1000 , 2 watt (b) 1000 , 4 watt
(c) 2000 , 4 watt (d) 1000 , 2 watt
58. We have three resistances each of value 1 , 2 and 3. If all the three
resistances are to be connected in a circuit, how many different values of
equivalent resistance are possible?
(a) Five (b) Six
(c) Seven (d) Eight
60. An electric heater draws 1000 watts from a 250 V source. The power
drawn from a 200 V source is
(a) 800 W (b) 640 W
(c) 1000 W (d) 1562.5 W
(a) 10 V (b) 5 V
(c) 2.5 V (d) 15 V
65. Super position theorem requires as many circuits to be solved as there are
(a) Nodes
(b) Sources
(c) Loops
(d) None of the above
77. Value of the load impedance ZL for which the load consumes maximum
power is
81. The average value of the voltage wave v = 110 +175 sin (314t – 25°) volts is
(a) 110 V (b) 175 V
(c) 165.57 V (d) 206.7 V
68. (c)
If the frequency of input voltage of a transformer is increased keeping the
magnitude of the voltage unchanged, then hysteresis loss will increase but eddy
current loss will remain unchanged.
1.If three 30 μF capacitors are connected in series, the net capacitance
is_________.
A. 10 μF B. 60 μF
C. 90 μF D. None of these
10. Two heaters, rated at 1000 W, 250 V each are connected in series across a
250 V, 50 Hz ac mains. The total power drawn from the supply would be
______ watt.
A. 1000 B. 500
C. 250 D. 2000
ANSWER
1 A 4 A 7 B
2 A 5 A 8 C
3 C 6 C 9 A
10 B
9 Sol. – as all three resistances are in parallel so potential across them will remain same
i.e. 4I1 = 5I2 = I3 -------------(i)
According to the KCL;
I1 + I2 + I3 = 8 ----------------(i)
From equation (i)
I2 = 45I1
I3 = 4 I1
Putting values in equation (ii)
I1 + 45I1 + 4I1 = 8
I1 = 40 29 = 1.38A
I2 = 45 × 1.38 = 1.10 A
I3 = 4×1.38 = 5.51 A