IS-Unity-DP Card

MODBUS, BACnet, SNMP data points


for PCW/PDX unit

Note: This is NOT the official is-UNITY-DP


documentation, that can be retrived from
the http://www.liebert.com web site

COD. 265106 Rev.4.5


23/11/2018
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

INDEX

MODBUS................................................................................................................................................................................. 3

MODBUS (TCP/485) INPUT STATUS REGISTERS ........................................................................................................ 3

MODBUS (TCP/485) COIL STATUS .................................................................................................................................. 5

MODBUS (TCP/485) INPUT REGISTERS ......................................................................................................................... 6

MODBUS (TCP/485) HOLDING REGISTERS ................................................................................................................ 17

BACNET ............................................................................................................................................................................... 24

BACNET ANALOG VALUES ............................................................................................................................................ 24

BACNET BINARY VALUES .............................................................................................................................................. 30

BACNET MULTI-STATE VALUES .................................................................................................................................. 33

SNMP ............................................................................................................................................................................... 39

SNMP PARAMETERS ........................................................................................................................................................ 39

SNMP EVENTS .................................................................................................................................................................... 56

2
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

MODBUS
MODBUS (TCP/485) Input Status Registers
Data Description Input Status Access Notes
REHEAT LOCKOUT (CUSTOMER INPUT) 10009 RO Active on Event
HUMIDIFIER LOCKOUT (CUSTOMER INPUT) 10010 RO Active on Event
MINIMUM CHILLED WATER TEMP SET POINT ENABLE 10013 RO Active on Event
RETURN AIR SENSOR EVENT CONTROL 10019 RO Active on Event
EXT AIR SENSOR A EVENT CONTROL 10020 RO Active on Event
COMPRESSOR(S) LOCKOUT (CUSTOMER INPUT) 10021 RO Active on Event
FAN STATE 10025 RO Active on Event
COOLING STATE 10026 RO Active on Event
FREE COOLING STATE 10027 RO Active on Event
HOT WATER / HOT GAS STATE 10028 RO Active on Event
ELECTRIC REHEAT STATE 10029 RO Active on Event
HUMIDIFIER STATE 10030 RO Active on Event
DEHUMIDIFIER STATE 10031 RO Active on Event
MAIN FAN OVERLOAD 10034 RO Active on Event
LOSS OF AIRFLOW 10035 RO Active on Event
LOSS OF FLOW (CUSTOMER INPUT) 10036 RO Active on Event
CIRC 1 HIGH PRESSURE 10037 RO Active on Event
CIRC 1 LOW PRESSURE 10038 RO Active on Event
COMP 1/1A THERMAL OVERLOAD 10039 RO Active on Event
CIRC 2 HIGH PRESSURE 10041 RO Active on Event
CIRC 2 LOW PRESSURE 10042 RO Active on Event
CO7MP 2/2A OVERLOAD 10043 RO Active on Event
DIG SCROLL1 HIGH TEMP 10045 RO Active on Event
DIG SCROLL2 HIGH TEMP 10046 RO Active on Event
SMOKE DETECTED (CUSTOMER INPUT) 10047 RO Active on Event
WATER UNDER FLOOR 10048 RO Active on Event
HUMIDIFIER PROBLEM 10049 RO Active on Event
COND PUMP-HIGH WATER (CUSTOMER INPUT) 10052 RO Active on Event
RETURN AIR SENSOR ISSUE 10053 RO Active on Event
LOSS OF AIR BLOWER 1 (CUSTOMER INPUT) 10055 RO Active on Event
HUMIDIFIER LOW WATER 10058 RO Active on Event
HUMIDIFIER HIGH AMPS 10059 RO Active on Event
HIGH TEMPERATURE (CUSTOMER INPUT) 10060 RO Active on Event
SHUTDOWN - LOSS OF POWER 10061 RO Active on Event
HIGH CW TEMP 10065 RO Active on Event
HIGH ROOM TEMP 10067 RO Active on Event
LOW ROOM TEMP 10068 RO Active on Event
HIGH ROOM HUM 10069 RO Active on Event
LOW ROOM HUM 10070 RO Active on Event
HIGH AISLE TEMPERATURE (WARNING) 10071 RO Active on Event
HIGH AISLE TEMPERATURE (ALARM) 10072 RO Active on Event
HIGH AISLE HUMIDITY (WARNING) 10073 RO Active on Event
HIGH AISLE HUMIDITY (ALARM) 10074 RO Active on Event
SUPPLY CHILLED WATER [1] LOSS OF FLOW 10075 RO Active on Event
CLOGGED FILTERS 10076 RO Active on Event
SUPPLY SENSOR FAILURE 10077 RO Active on Event
FREECOOL TEMP SENSOR 10078 RO Active on Event
UNIT HRS EXCEEDED 10080 RO Active on Event
COMP 1/1A HRS EXCEEDED 10081 RO Active on Event
COMP 2/2A HRS EXCEEDED 10082 RO Active on Event

3
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Input Status Access Notes
FC HRS EXCEEDED 10083 RO Active on Event
EL HEAT1 HRS EXCEEDED 10084 RO Active on Event
EL HEAT2 HRS EXCEEDED 10085 RO Active on Event
EL HEAT3 HRS EXCEEDED 10086 RO Active on Event
HW/HG HRS EXCEEDED 10087 RO Active on Event
HUM HRS EXCEEDED 10088 RO Active on Event
DEHUM HRS EXCEEDED 10089 RO Active on Event
NO CONNECTION W/UNIT1 10092 RO Active on Event
UNIT CODE MISSING 10094 RO Active on Event
CUSTOMER INPUT 1 10104 RO Active on Event
CUSTOMER INPUT 2 10105 RO Active on Event
CUSTOMER INPUT 3 10106 RO Active on Event
CUSTOMER INPUT 4 10107 RO Active on Event
DSCROLL 1 SENSOR FAIL 10108 RO Active on Event
DSCROLL 2 SENSOR FAIL 10109 RO Active on Event
HIGH SUPPLY TEMPERATURE 10209 RO Active on Event
LOW SUPPLY TEMPERATURE 10210 RO Active on Event
AMBIENT AIR SENSOR ISSUE 10211 RO Active on Event
CIRC 1 SHORT CYCLE 10212 RO Active on Event
CIRC 2 SHORT CYCLE 10213 RO Active on Event
FC LOCKOUT (CUSTOMER INPUT) 10214 RO Active on Event
EL HEAT HIGH TEMP / HEATERS OVERHEATED 10215 RO Active on Event
HUM CYLINDER WORN 10216 RO Active on Event
HUMIDIFIER LOW AMPS 10217 RO Active on Event
EC FAN FAULT 10218 RO Active on Event
CONDENSER 1 FAILURE 10221 RO Active on Event
CONDENSER 2 FAILURE 10222 RO Active on Event
BMS DISCONNECTED 10223 RO Active on Event
DIGITAL OUTPUT BOARD [1] NOT DETECTED 10224 RO Active on Event
DIGITAL OUTPUT BOARD [2] NOT DETECTED 10225 RO Active on Event
DIGITAL OUTPUT BOARD [3] NOT DETECTED 10226 RO Active on Event
LWD SENSOR FAIL 10228 RO Active on Event
FIRE ALARM 10229 RO Active on Event
UNIT OFF 10232 RO Active on Event
UNIT ON 10233 RO Active on Event
UNIT DISABLED 10234 RO Active on Event
UNIT SHUT DOWN 10235 RO Active on Event
NO POWER 10236 RO Active on Event
UNIT STANDBY 10237 RO Active on Event
LP TRANSDUCER 1 FAIL 10240 RO Active on Event
LP TRANSDUCER 2 FAIL 10241 RO Active on Event
HP 1 SENSOR FAIL 10242 RO Active on Event
HP 2 SENSOR FAIL 10243 RO Active on Event
COMP POWER REDUCTION ACTIVE 10244 RO Active on Event
DEW POINT OVER TEMPERATURE 10345 RO Active on Event
DEW POINT UNDER TEMPERATURE 10346 RO Active on Event
EXT DEW POINT OVER TEMPERATURE 10347 RO Active on Event
EXT DEW POINT UNDER TEMPERATURE 10348 RO Active on Event
REDUCED ECO AIRFLOW 10387 RO Active on Event
EEV UNSPECIFIED GENERAL EVENT 10488 RO Active on Event
STATIC PRESSURE SENSOR ISSUE 10489 RO Active on Event
PUMP UNSPECIFIED GENERAL EVENT 10492 RO Active on Event
EXT AIR DAMPER POSITION ISSUE 10604 RO Active on Event

4
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Input Status Access Notes
STATIC PRESSURE SENSOR OUT OF RANGE 10607 RO Active on Event
COMP 1B OVERLOAD 10741 RO Active on Event
COMP 2B OVERLOAD 10742 RO Active on Event
COMP 1B HRS EXCEEDED 10743 RO Active on Event
COMP 2B HRS EXCEEDED 10744 RO Active on Event
TEAM STATIC PRESSURE SENSOR FAILURE 10750 RO Active on Event
HEATING LOCKOUT 10751 RO Active on Event
FREE COOLING STOPPED - HIGH ROOM TEMP 10752 RO Active on Event
COLD AISLE TEMPERATURE/HUMIDITY TEAM SENSOR FAILURE 10753 RO Active on Event
COLD AISLE AIR SENSOR [1] FAILURE 10760 RO Active on Event
COLD AISLE AIR SENSOR [2] FAILURE 10761 RO Active on Event
COLD AISLE AIR SENSOR [3] FAILURE 10762 RO Active on Event
CHILLED WATER INLET TEMPERATURE CONTROL ACTIVE 10770 RO Active on Event
CHILLED WATER [1] INLET TEMPERATURE SENSOR FAILURE 10780 RO Active on Event
CHILLED WATER [2] INLET TEMPERATURE SENSOR FAILURE 10781 RO Active on Event
CHILLED WATER [1] OUTLET TEMPERATURE SENSOR FAILURE 10782 RO Active on Event
CHILLED WATER [2] OUTLET TEMPERATURE SENSOR FAILURE 10783 RO Active on Event
CHILLED WATER [1] FLOW METER SENSOR FAILURE 10784 RO Active on Event
CHILLED WATER [2] FLOW METER SENSOR FAILURE 10785 RO Active on Event
STANDBY UNIT ACTIVATED DUE TO CHILLER FAILURE 10790 RO Active on Event
SUPPLY CHILLED WATER [2] LOSS OF FLOW 10791 RO Active on Event
VIRTUAL SYSTEM ACTIVE 18000 RO Active on Event
PHASE SEQUENCE 18001 RO Active on Event

MODBUS (TCP/485) Coil Status


Data Description Coil Status Access Notes
0 = Disabled
Minimum Chilled Water Temp Set Point Enable 13 RW
1 = Enabled
0 = Disabled
Return Air Sensor Event Control 19 RW
1 = Enabled
0 = Disabled
Ext Air Sensor A Event Control 20 RW
1 = Enabled
0 = Off
System On/Off Control 25 RW
1 = On

5
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

MODBUS (TCP/485) Input Registers


Input
Data Description Unit Scale Access CDL parameter Notes
Register
0 = Disabled
S137 DT2 (Room / FC
Free Cooling Internal Control Mode 30017 x1 RO 1 = Contacts
Fluid) Type
2 = Value
Fan Speed Maximum Set Point 30019 % x1 RO S148 VSD Setpoint STD
U106/S125 Supply
Supply Air Temperature Set Point 30020 deg C x10 RO
Setpoint
S138 DT2 (Room / FC
Free Cooling Internal Temperature Delta 30021 deg C x10 RO
Fluid) Value
S140 Minimum CW
Minimum Chilled Water Temp Set Point 30022 deg C x10 RO
Temp Value
U102/S102
Air Temperature Set Point 30023 deg C x10 RO
Temperature Setpoint
S104 Temperature
Air Temperature Proportional Band 30024 deg C x10 RO
Proportional Band
S108 Temperature Dead
Air Temperature Dead Band 30025 deg C x10 RO
Band
Air Temperature Control Integration S105 Temperature
30026 min x10 RO
Time Integration Time
Humidity Set Point 30027 % RH x1 RO U103/S113
Humidity Proportional Band 30028 % RH x1 RO S115
S116 Humidity
Humidity Control Integration Time 30029 min x1 RO
Integration Time
Humidity Dead Band 30030 % RH x10 RO S117
S421 Single Unit Auto
Auto Restart Delay 30031 sec x1 RO
Restart
0 = Proportional
1 = Prop.+Integral
Air Temperature Control Type 30033 x1 RO S103 Control Type
2 = Not used
3 = Intelligent
S825 Monitoring
BMS Timeout Period 30045 min x1 RO
Timeout/Handshake
U203/S203 High Return
High Return Air Temperature Threshold 30050 deg C x10 RO
Temperature
U204/S204 Low Return
Low Return Air Temperature Threshold 30051 deg C x10 RO
Temperature
U205/S205 High Return
High Return Humidity Threshold 30054 % RH x10 RO
Humidity
U206/S206 Low Return
Low Return Humidity Threshold 30055 % RH x10 RO
Humidity
Fan Hours Threshold 30070 hr x1 RO U502 Fan Motor(s)
U503 Compressor 1A
Compressor [1A] Hours Threshold 30071 hr x1 RO
Limit
U504 Compressor 2A
Compressor [2A] Hours Threshold 30072 hr x1 RO
Limit
Humidifier Hours Threshold 30073 hr x1 RO U511 Humidifier Limit
U512 Dehumidifier
Dehumidifier Hours Threshold 30074 hr x1 RO
Limit
Free Cooling Valve Hours Threshold 30075 hr x1 RO U506 Free Cool Limit
U508 Electric Heater 1
Electric [1] Reheater Hours Threshold 30076 hr x1 RO
Limit
U509 Electric Heater 2
Electric [2] Reheater Hours Threshold 30077 hr x1 RO
Limit

6
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
U510 Electric Heater 3
Electric [3] Reheater Hours Threshold 30078 hr x1 RO
Limit
Hot Water / Hot Gas Valve Hours U507 HotGas /
30079 hr x1 RO
Threshold HotWater Limit
0 = Off
Unit Operating State 30100 x1 RO 1 = On
2 = Standby
1 = Normal
Operation
8 = Normal with
Warning
System Status 30102 x1 RO
16 = Normal with
Alarm
32 = Unit OFF due
to Alarm
Fan Speed 30103 % x1 RO Main Unit Screen
Compressor/CW Valve Utilization 30104 % x1 RO Main Unit Screen
Free Cooling Valve Open Position 30105 % x1 RO Main Unit Screen: FC
Reheat Utilization 30106 % x1 RO Main Unit Screen
Humidifier Utilization 30107 % x1 RO Main Unit Screen
Dehumidifier Utilization 30108 % x1 RO Main Unit Screen
0 = Off
Free Cooling Status 30109 x1 RO U309 1 = Start
2 = FC On
Return Air Temperature 30110 deg C x10 RO Main Unit Screen, S603
Supply Air Temperature 30112 deg C x10 RO Main Unit Screen, S629
Supply Setpoint
Supply Air Temperature Set Point 30113 deg C x10 RO
U106/S125
Free Cooling Fluid Temperature 30115 deg C x10 RO U307/S626
Optional Sensor A1
Ext Air Sensor A Temperature 30116 deg C x10 RO
U301/S614
Optional Sensor B1
Ext Air Sensor B Temperature 30117 deg C x10 RO
U303/S619
Optional Sensor C1
Ext Air Sensor C Temperature 30118 deg C x10 RO
U305/S631
U310/S607 DigiScroll 1
Dig Scroll Comp [1] Discharge Temp 30119 deg C x1 RO
Temperature
U311/S609 DigiScroll 2
Dig Scroll Comp [2] Discharge Temp 30120 deg C x1 RO
Temperature
Return Humidity 30130 % RH x10 RO Main Unit Screen, S605
Optional Sensor A2
Ext Air Sensor A Humidity 30132 % RH x10 RO
U302/S616
Optional Sensor B2
Ext Air Sensor B Humidity 30133 % RH x10 RO
U304/S621
Optional Sensor C2
Ext Air Sensor C Humidity 30134 % RH x10 RO
U306/S633
U502 Fan Motor(s)
Fan Hours 30141 hr x1 RO
Actual hours
U503 Compressor 1A
Compressor [1A] Hours 30142 hr x1 RO
Actual Hours
U504 Compressor 2A
Compressor [2A] Hours 30143 hr x1 RO
Actual Hours
U511 Humidifier Actual
Humidifier Hours 30144 hr x1 RO
Hours

7
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
U512 Dehumidifier
Dehumidifier Hours 30145 hr x1 RO
Actual Hours
U506 Free Cool Actual
Free Cooling Valve Hours 30146 hr x1 RO
Hours
U508 Electric Heater 1
Electric [1] Reheater Hours 30147 hr x1 RO
Actual Hours
U509 Electric Heater 2
Electric [2] Reheater Hours 30148 hr x1 RO
Actual Hours
U510 Electric Heater 3
Electric [3] Reheater Hours 30149 hr x1 RO
Actual Hours
U507 HotGas /
Hot Water / Hot Gas Valve Hours 30150 hr x1 RO
HotWater Actual Hours
U313 Daily High
Today's High Air Temperature 30151 deg C x10 RO
Temperature
U314 Daily Low
Today's Low Air Temperature 30153 deg C x10 RO
Temperature
U315 Daily High
Today's High Humidity 30155 % RH x10 RO
Humidity
U316 Daily Low
Today's Low Humidity 30157 % RH x10 RO
Humidity
1 = UPS
2 = AIR
Server Class 30257 x1 RO
3 = PMP
4 = PDU
# Registers (2)
Today's High Air Temperature Time 30258 x1 RO U313 (in seconds)
(in seconds)
# Registers (2)
Today's Low Air Temperature Time 30260 x1 RO U314 (in seconds)
(in seconds)
0 = Disabled
S124 Supply Sensor 1 = Limit
Supply Air Temperature Sensor Control 30262 x1 RO
2 = Control
3 = Cooling Only
Main Unit Screen,
Actual Return Air Temperature Set Point 30263 deg C x10 RO U102/S102
Temperature Setpoint
Main Unit Screen,
Actual Return Humidity Set Point 30264 % RH x1 RO U103/S113 Humidity
Setpoint
# Registers (2)
Today's High Humidity Time 30265 x1 RO U315 (in seconds)
(in seconds)
# Registers (2)
Today's Low Humidity Time 30267 x1 RO U316 (in seconds)
(in seconds)
0 = Off
Compressor [1] State 30269 x1 RO
1 = On
0 = Off
Compressor [2] State 30270 x1 RO
1 = On
S316 Compressor 1 0 = Off
Compressor [1] Capacity Control State 30271 x1 RO
Capacity 1 = On
S320 Compressor 2 0 = Off
Compressor [2] Capacity Control State 30272 x1 RO
Capacity 1 = On
Infrared Humidifier Flush Rate 30273 % x1 RO S414 Infrared Flush Rate
0 = Auto
1 = Manual
Fan Control Mode 30274 x1 RO S146 VSD Fanspeed
2 = Economy
4 = Delta
Analog Input [1] Reading 30275 x100 RO A688

8
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
Analog Input [2] Reading 30276 x100 RO A689
Analog Input [3] Reading 30277 x100 RO A690
Analog Input [4] Reading 30278 x100 RO A691
0 = Internal (Auto)
Unit Control Mode 30280 x1 RO S313 Manual Mode 1 = External
(Manual)
0 = Reason
Unknown
1 = Network
Display
2 = Alarm
Unit Operating State Reason 30281 x1 RO
3 = Schedule
4 = Remote
System
5 = External Input
6 = Local Display
Maintenance Ramp 30282 % x1 RO Main Unit Screen
Main Unit Screen,
Calculated Next Maintenance Month 30283 x1 RO Calculated Next
Maintenance S008
Main Unit Screen,
Calculated Next Maintenance Year 30284 x1 RO Calculated Next
Maintenance S008
Hot Water / Hot Gas Valve Open Position 30285 % x1 RO CDL Main Unit Screen
0 = Disabled
S275
Customer Input 1 - Event Control 30287 x1 RO 1 = Enabled
0 = Message
Customer Input 1 - Event Type 30288 x1 RO S275 1 = Warning
2 = Alarm
0 = Disabled
Customer Input 2 - Event Control 30289 x1 RO S276
1 = Enabled
0 = Message
Customer Input 2 - Event Type 30290 x1 RO S276 1 = Warning
2 = Alarm
0 = Disabled
Customer Input 3 - Event Control 30291 x1 RO S277
1 = Enabled
0 = Message
Customer Input 3 - Event Type 30292 x1 RO S277 1 = Warning
2 = Alarm
0 = Disabled
Customer Input 4 - Event Control 30293 x1 RO S278
1 = Enabled
0 = Message
Customer Input 4 - Event Type 30294 x1 RO S278 1 = Warning
2 = Alarm
0 = Disabled
Ext Free Cooling Lockout - Event Control 30295 x1 RO S284
1 = Enabled
0 = Message
Ext Free Cooling Lockout - Event Type 30296 x1 RO S284 1 = Warning
2 = Alarm
Ext Condenser Pump High Water - Event 0 = Disabled
30297 x1 RO S265
Control 1 = Enabled
0 = Message
Ext Condenser Pump High Water - Event
30298 x1 RO S265 1 = Warning
Type
2 = Alarm
0 = Disabled
Ext Humidifier Lockout - Event Control 30303 x1 RO S283
1 = Enabled

9
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
0 = Message
Ext Humidifier Lockout - Event Type 30304 x1 RO S283 1 = Warning
2 = Alarm
0 = Disabled
Ext Loss of Flow - Event Control 30305 x1 RO S266
1 = Enabled
0 = Message
Ext Loss of Flow - Event Type 30306 x1 RO S266 1 = Warning
2 = Alarm
0 = Disabled
Ext Over Temperature - Event Control 30307 x1 RO S280
1 = Enabled
0 = Message
Ext Over Temperature - Event Type 30308 x1 RO S280 1 = Warning
2 = Alarm
0 = Disabled
Ext Reheat Lockout - Event Control 30309 x1 RO S282
1 = Enabled
0 = Message
Ext Reheat Lockout - Event Type 30310 x1 RO S282 1 = Warning
2 = Alarm
0 = Disabled
High Power Shutdown - Event Control 30311 x1 RO S290
1 = Enabled
0 = Message
High Power Shutdown - Event Type 30312 x1 RO S290 1 = Warning
2 = Alarm
0 = Disabled
Humidifier Issue - Event Control 30313 x1 RO S269
1 = Enabled
0 = Message
Humidifier Issue - Event Type 30314 x1 RO S269 1 = Warning
2 = Alarm
Master Unit Communication Lost - Event 0 = Disabled
30315 x1 RO S270
Control 1 = Enabled
0 = Message
Master Unit Communication Lost - Event x1 RO
30316 S270 1 = Warning
Type x1 RO
2 = Alarm
Shutdown - Loss Of Power - Event 0 = Disabled
30319 x1 RO S272
Control 1 = Enabled
0 = Message
Shutdown - Loss Of Power - Event Type 30320 x1 RO S272 1 = Warning
2 = Alarm
0 = Disabled
Smoke Detected - Event Control 30321 x1 RO S263
1 = Enabled
0 = Message
Smoke Detected - Event Type 30322 x1 RO S263 1 = Warning
2 = Alarm
0 = Disabled
Water Under Floor - Event Control 30323 x1 RO S264
1 = Enabled
0 = Message
Water Under Floor - Event Type 30324 x1 RO S264 1 = Warning
2 = Alarm
0 = Disabled
Ext Compressor Lockout - Event Control 30325 x1 RO S285
1 = Enabled
0 = Message
Ext Compressor Lockout - Event Type 30326 x1 RO S285 1 = Warning
2 = Alarm
0 = Disabled
Clogged Air Filter - Event Control 30327 x1 RO S238
1 = Enabled
Clogged Air Filter - Event Type 30328 x1 RO S238 0 = Message

10
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
1 = Warning
2 = Alarm
Compressor [1] High Head Pressure - 0 = Disabled
30331 x1 RO S251
Event Control 1 = Enabled
Compressor [2] High Head Pressure - 0 = Disabled
30332 x1 RO S252
Event Control 1 = Enabled
0 = Message
Compressor [1] High Head Pressure -
30333 x1 RO S251 1 = Warning
Event Type
2 = Alarm
0 = Message
Compressor [2] High Head Pressure -
30334 x1 RO S252 1 = Warning
Event Type
2 = Alarm
Compressor [1] Low Suction Pressure - 0 = Disabled
30335 x1 RO S253
Event Control 1 = Enabled
Compressor [2] Low Suction Pressure - 0 = Disabled
30336 x1 RO S254
Event Control 1 = Enabled
0 = Message
Compressor [1] Low Suction Pressure -
30337 x1 RO S253 1 = Warning
Event Type
2 = Alarm
Compressor [2] Low Suction Pressure - x1 RO 0 = Message
Event Type 30338 S254 1 = Warning
x1 RO 2 = Alarm
Compressor [1] Short Cycle - Event 0 = Disabled
30343 x1 RO S288
Control 1 = Enabled
Compressor [2] Short Cycle - Event 0 = Disabled
30344 x1 RO S289
Control 1 = Enabled
0 = Message
Compressor [1] Short Cycle - Event Type 30345 x1 RO S288 1 = Warning
2 = Alarm
0 = Message
Compressor [2] Short Cycle - Event Type 30346 x1 RO S289 1 = Warning
2 = Alarm
Compressor [1] Thermal Overload - Event 0 = Disabled
30347 x1 RO S249
Control 1 = Enabled
Compressor [2] Thermal Overload - 0 = Disabled
30348 x1 RO S250
Event Control 1 = Enabled
0 = Message
Compressor [1] Thermal Overload - Event
30349 x1 RO S249 1 = Warning
Type
2 = Alarm
0 = Message
Compressor [2] Thermal Overload -
30350 x1 RO S250 1 = Warning
Event Type
2 = Alarm
Dig Scroll Comp [1] Discharge Over Temp 0 = Disabled
30351 x1 RO S257
- Event Ctrl 1 = Enabled
Dig Scroll Comp [2] Discharge Over Temp 0 = Disabled
30352 x1 RO S258
- Event Ctrl 1 = Enabled
0 = Message
Dig Scroll Comp [1] Discharge Over Temp
30353 x1 RO S257 1 = Warning
- Event Type
2 = Alarm
0 = Message
Dig Scroll Comp [2] Discharge Over Temp
30354 x1 RO S258 1 = Warning
- Event Type
2 = Alarm
0 = Disabled
High Return Humidity - Event Control 30363 x1 RO S241/S202
1 = Enabled
0 = Message
High Return Humidity - Event Type 30364 x1 RO S241
1 = Warning

11
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
2 = Alarm
0 = Disabled
Low Return Humidity - Event Control 30365 x1 RO S241/S202
1 = Enabled
0 = Message
Low Return Humidity - Event Type 30366 x1 RO S242 1 = Warning
2 = Alarm
0 = Disabled
Return Air Over Temp - Event Control 30367 x1 RO S239/S202
1 = Enabled
0 = Message
Return Air Over Temp - Event Type 30368 x1 RO S239 1 = Warning
2 = Alarm
0 = Disabled
Return Air Under Temp - Event Control 30369 x1 RO S240/S202
1 = Enabled
0 = Message
Return Air Under Temp - Event Type 30370 x1 RO S240 1 = Warning
2 = Alarm
0 = Disabled
Fan Hours Exceeded - Event Control 30371 x1 RO S262
1 = Enabled
0 = Message
Fan Hours Exceeded - Event Type 30372 x1 RO S262 1 = Warning
2 = Alarm
0 = Disabled
Fan Issue - Event Control 30373 x1 RO S237 Loss of Airflow
1 = Enabled
0 = Disabled
Main Fan Overload - Event Control 30375 x1 RO S236
1 = Enabled
0 = Message
Main Fan Overload - Event Type 30376 x1 RO S236 1 = Warning
2 = Alarm
S291 Condenser 1 0 = Disabled
Condenser [1] Issue - Event Control 30377 x1 RO
Failure 1 = Enabled
S292 Condenser 2 0 = Disabled
Condenser [2] Issue - Event Control 30378 x1 RO
Failure 1 = Enabled
0 = Message
S291 Condenser 1
Condenser [1] Issue - Event Type 30379 x1 RO 1 = Warning
Failure
2 = Alarm
0 = Message
S292 Condenser 2
Condenser [2] Issue - Event Type 30380 x1 RO 1 = Warning
Failure
2 = Alarm
Outside Air Temperature 30484 deg C x10 RO U308
0 = Relative
S114 Humidity Control 1 = Compensated
Humidity Control Type 30485 x1 RO
Type 2= Predicted
3= Dew Point
Adjusted Humidity 30499 % RH x10 RO Main Unit Screen, S605
Return Dew Point 30500 deg C x10 RO Main Unit Screen
Dew Point Set Point 30503 deg C x10 RO S102
Chilled Water Valve Hours 30563 hr x1 RO U505 Chilled Water 1
Static Pressure Set Point 30672 Pa x10 RO AA07
AA06 and U323 Actual
System Static Pressure 30674 Pa x10 RO
FP1 Pressure
U106/S125 Supply
Supply Air Temperature Set Point 30733 deg F x10 RO
Setpoint
S138 DT2 (Room / FC
Free Cooling Internal Temperature Delta 30734 deg F x10 RO
Fluid) Value
S140 Minimum CW
Minimum Chilled Water Temp Set Point 30735 deg F x10 RO
Temp Value

12
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
U102/S102
Air Temperature Set Point 30736 deg F x10 RO
Temperature Setpoint
S104 Temperature
Air Temperature Proportional Band 30737 deg F x10 RO
Proportional Band
S108 Temperature Dead
Air Temperature Dead Band 30738 deg F x10 RO
Band
U203/S203 High Return
High Return Air Temperature Threshold 30739 deg F x10 RO
Temperature
U204/S204 Low Return
Low Return Air Temperature Threshold 30740 deg F x10 RO
Temperature
Return Air Temperature 30743 deg F x10 RO Main Unit Screen, S603
Supply Air Temperature 30744 deg F x10 RO Main Unit Screen, S629
U106/S125 Supply
Supply Air Temperature Set Point 30745 deg F x10 RO
Setpoint
Free Cooling Fluid Temperature 30746 deg F x10 RO U307/S626
Optional Sensor A1
Ext Air Sensor A Temperature 30747 deg F x10 RO
U301/S614
Optional Sensor B1
Ext Air Sensor B Temperature 30748 deg F x10 RO
U303/S619
Optional Sensor C1
Ext Air Sensor C Temperature 30749 deg F x10 RO
U305/S631
U310/S607 DigiScroll 1
Dig Scroll Comp [1] Discharge Temp 30750 deg F x1 RO
Temperature
U311/S609 DigiScroll 2
Dig Scroll Comp [2] Discharge Temp 30751 deg F x1 RO
Temperature
U313 Daily High
Today's High Air Temperature 30752 deg F x10 RO
Temperature
U314 Daily Low
Today's Low Air Temperature 30753 deg F x10 RO
Temperature
Main Unit Screen,
Actual Return Air Temperature Set Point 30754 deg F x10 RO U102/S102
Temperature Setpoint
Outside Air Temperature 30757 deg F x10 RO U308
Return Dew Point 30762 deg F x10 RO Main Unit Screen
Dew Point Set Point 30764 deg F x10 RO S102
System Input RMS A-N 30800 VAC x10 RO S3A2 (2nd column) Power Meter #1
System Input RMS B-N 30810 VAC x10 RO S3A2 (3rd column) Power Meter #1
System Input RMS C-N 30820 VAC x10 RO S3A2 (4th column) Power Meter #1
System Input RMS Current Phase A 30830 A AC x10 RO S3A3 (2nd column) Power Meter #1
System Input RMS Current Phase B 30840 A AC x10 RO S3A3 (3rd column) Power Meter #1
System Input RMS Current Phase C 30850 A AC x10 RO S3A3 (4th column) Power Meter #1
Power Meter #1
Instantaneous Power 30860 W x1 RO S3A2 (5th column)
# Registers (2)
Power Meter #1
Energy Consumption 30870 kWH x1 RO S3A3 (5th column)
# Registers (2)
Fluid Flow Rate (Chilled Water->Chilled 30908
l/s x10 RO U319
Water Circuit [1] 30909
Fluid Flow Rate (Chilled Water->Chilled 30910
l/s x10 RO U319
Water Circuit [2] 30911
Power Meter #2
Instantaneous Power 31010 W x1 RO S3A7 (5th column)
# Registers (2)
System Input RMS A-B 31060 VAC x10 RO S3A1 (2nd column) Power Meter #1
System Input RMS B-C 31070 VAC x10 RO S3A1 (3rd column) Power Meter #1
System Input RMS C-A 31080 VAC x10 RO S3A1 (4th column) Power Meter #1
Cold Aisle Humidity Calculation Method 31200 x1 RO SB10 Humidity 0 = Highest

13
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
Controlled by 1 = Average
Cold Aisle Temperature Calculation SB06 Temperature 0 = Highest
31201 x1 RO
Method Controlled by 1 = Average
0 = Disabled
Cold Aisle Control Enable 31202 x1 RO SB02
1 = Enabled
Cold Aisle Force Max Fan/Cooling - Ext SB57 Fan and Cooling 0 = No
31203 x1 RO
Control 100% by User 1 = Yes
SB55 Value Sent to
Actual Cold Aisle Humidity 31204 % RH x10 RO
Master
SB44 Value Sent to
Actual Cold Aisle Temperature 31205 deg C x10 RO
Master
Actual Cold Aisle Temperature 31206 deg F x10 RO
Cold Aisle Cascade Fan Speed Max Set
31207 % x1 RO SB19 Cascade VSD Limit
Point
Cold Aisle Fan Speed Min Set Point 31208 % x1 RO SB17 VSD Fanspeed Min
SB18 VSD Fanspeed
Cold Aisle Fan Speed Max Set Point 31209 % x1 RO
Max
0 = Disabled
Chilled Water Valve Reset Enable 31211 x1 RO S439 CW Valve Reset
1 = Enabled
A161 Min Hum
Humidification Fan Speed Min Set Point 31212 % x1 RO
Fanspeed
A161 Min Heat
Heating Fan Speed Min Set Point 31213 % x1 RO
Fanspeed
Dehumidification Fan Speed Min Set A161 Min Dehum
31214 % x1 RO
Point Fanspeed
Back Draft Control Fan Speed 31215 % x1 RO S150
Super Saver Call For Cooling 31320 % x1 RO Main unit Screen
Compressor [1A] Hours 31340 hr x1 RO U503 Compressor 1A # Registers (2)
Compressor [2A] Hours 31342 hr x1 RO U504 Compressor 2A # Registers (2)
Chilled Water [1] Valve Hours 31344 hr x1 RO U505 Chilled Water 1/2 # Registers (2)
Free Cooling Valve Hours 31346 hr x1 RO U506 Free Cool # Registers (2)
U507 HotGas /
31348 hr x1 RO # Registers (2)
Hot Water / Hot Gas Valve Hours HotWater
Electric Reheater [1] Hours 31350 hr x1 RO U508 Electric Heater 1 # Registers (2)
Electric Reheater [2] Hours 31352 hr x1 RO U509 Electric Heater 2 # Registers (2)
Electric Reheater [3] Hours 31354 hr x1 RO U510 Electric Heater 3 # Registers (2)
Humidifier Hours 31356 hr x1 RO U511 Humidifier # Registers (2)
Dehumidifier Hours 31358 hr x1 RO U512 Dehumidification # Registers (2)
Fan Hours 31360 hr x1 RO U507 Fan Motor(s) # Registers (2)
Static Pressure Set Point 31370 inWC x1000 RO AA07
U323 Actual FP1
System Static Pressure 31372 inWC x1000 RO
Pressure
Dew Point Proportional Band 31380 deg C x10 RO S104
Dew Point Proportional Band 31382 deg F x10 RO S104
Dew Point Dead Band 31384 deg C x10 RO S108
Dew Point Dead Band 31386 deg F x10 RO S108
0 = Disabled
Underfloor Static Pressure Control AA02 Underfloor Static
31400 - x1 RO 1 = Enabled
Enable Pressure
2= Visualiz. Only
S377 Status Damper 0 = N.C. / Cls
Return Damper Status 31401 - x1 RO
(Fan) 1 = N.O. /Opn
AA41, U324 Air
Air Differential Pressure 31402 Pa x1 RO
Differential Pressure
AA41, U324 Air
Air Differential Pressure 31403 inWC x100 RO
Differential Pressure

14
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
SB37 Calibrated Remote
Cold Aisle Sensor [1] Air Temperature 31410 deg C x10 RO 1/10 °C
THB 1
SB40 Calibrated Remote
Cold Aisle Sensor [2] Air Temperature 31411 deg C x10 RO 1/10 °C
THB 2
SB43 Calibrated Remote
Cold Aisle Sensor [3] Air Temperature 31412 deg C x10 RO 1/10 °C
THB 3
SB48 Calibrated Remote
Cold Aisle Sensor [1] Humidity 31413 % RH x10 RO
THB 1
SB51 Calibrated Remote
Cold Aisle Sensor [2] Humidity 31414 % RH x10 RO
THB 2
SB54 Calibrated Remote
Cold Aisle Sensor [3] Humidity 31415 % RH x10 RO
THB 3
SB37 Calibrated Remote
Cold Aisle Sensor [1] Air Temperature 31416 deg F x10 RO 1/10 °F
THB 1
SB40 Calibrated Remote
Cold Aisle Sensor [2] Air Temperature 31417 deg F x10 RO 1/10 °F
THB 2
SB43 Calibrated Remote
Cold Aisle Sensor [3] Air Temperature 31418 deg F x10 RO 1/10 °F
THB 3
U317 Inlet Water
Chilled Water [1] Inlet Temperature 31420 deg C x10 RO 1/10 °C
Temperature
U317 Inlet Water
Chilled Water [2] Inlet Temperature 31421 deg C x10 RO Temperature 1/10 °C
(as B1/2T sensor, U303)
U318 Outlet Water
Chilled Water [1] Outlet Temperature 31422 deg C x10 RO 1/10 °C
Temperature
U318 Outlet Water
Chilled Water [2]Outlet Temperature 31423 deg C x10 RO Temperature 1/10 °C
(as B2/2T sensor, U304)
U317 Inlet Water
Chilled Water [1] Inlet Temperature 31424 deg F x10 RO 1/10 °F
Temperature
U317 Inlet Water
Chilled Water [2] Inlet Temperature 31425 deg F x10 RO Temperature 1/10 °F
(as B1/2T sensor, U303)
U318 Outlet Water
Chilled Water [1] Outlet Temperature 31426 deg F x10 RO 1/10 °F
Temperature
U318 Outlet Water
Chilled Water [2]Outlet Temperature 31427 deg F x10 RO Temperature 1/10 °F
(as B2/2T sensor, U304)
Chilled Water [2] Valve Hours 31430 hr x1 RO U505 Chilled Water 1/2
S310 Actual HP1
Compressor [1] Discharge Pressure 31432 bar x100 RO 1/100 bar
Pressure
S311 Actual HP2
Compressor [2] Discharge Pressure 31434 bar x100 RO 1/100 bar
Pressure
A197 Total Cooling
Cooling Capacity [1] 31436 kW x10 RO Gross Capacity, U320 1/10 kW
Cool Gross Cap.
A197 Total Cooling
Cooling Capacity [2] 31438 kW x10 RO Gross Capacity, U320 1/10 kW
Cool Gross Cap.
S362 Status Loss Flow 0 = OK
Chilled Water [1] Flow Loss Status 31440 - x1 RO
C1 1 = Act.
S363 Status Loss Flow 0 = OK
Chilled Water [2] Flow Loss Status 31442 - x1 RO
C2/High Temp 1 = Act.
Customer Configurable Analog Output
31444 % x1 RO S341, A163
[1] Value
Customer Configurable Analog Output 31446 % x1 RO S342, A164

15
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Input
Data Description Unit Scale Access CDL parameter Notes
Register
[2] Value
Customer Configurable Analog Output
31448 % x1 RO S343, A165
[3] Value
Customer Configurable Analog Output
31450 % x1 RO S344, A166
[4] Value
Automatic Transfer Switch - Active Power 0=Power Supply 1
31452 % x1 RO S364
Supply 1=Power Supply 2
Automatic Transfer Switch - Power 0="OK"
31453 % x1 RO S365
Supply 1 Status 1="Not OK"
Automatic Transfer Switch - Power 0="OK"
31454 % x1 RO S366
Supply 2 Status 1="Not OK"
Fluid Flow Rate (Chilled Water->Chilled
31456 m3/h x1 RO U319
Water Circuit [1])
Fluid Flow Rate (Chilled Water->Chilled
31457 m3/h x1 RO U319
Water Circuit [2])
0 = MAN; 1 = OFF;
MAN-OFF-AUTO Switch 38006 x1 RO
2 = AUTO
Condenser 1 ambient outside air
38007 x100 RO AB12
temperature
Condenser 2 ambient outside air
38008 x100 RO AB12
temperature
Power Meter #1
0 = Off
1 = Ok
Power Meter Status 38010 x1 RO S3A2 (1st column) 2 = Wait
3 = ECom
4 = ENC
5 = Ecfg
Actual Compressor 1 Suction Pressure 38011 bar x100 RO S308
Actual Compressor 2 Suction Pressure 38012 bar x100 RO S309
0 = Valve 1
Main Valve 38077 x1 RO S430
1 = Valve 2
0 = Disabled
Fan Speed Delta Control 38078 x1 RO S168
1 = Enabled
0 = Single,
1 = 2 Parallel,
CW Valve Control 38079 x1 RO S429
2 = 2 Alternate,
3 = 2 Cascade
Main Unit Screen, U402, # Registers (2)
System Date and Time 39998 x1 RO
U403 Unix Time Stamp

16
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

MODBUS (TCP/485) Holding Registers


Holding
Data Description Unit Scale Access CDL parameter Notes
Register
0 = Disabled
S137 DT2
Free Cooling Internal Control Mode 40017 x1 WR 1 = Contacts
(Room / FC Fluid) Type
2 = Value
Fan Speed Maximum Set Point 40019 % x1 WR S148 VSD Setpoint STD
U106/S125 Supply
Supply Air Temperature Set Point 40020 deg C x10 WR
Setpoint
S138 DT2
Free Cooling Internal Temperature Delta 40021 deg C x10 WR
(Room / FC Fluid) Value
S140 Minimum CW
Minimum Chilled Water Temp Set Point 40022 deg C x10 WR
Temp Value
U102/S102
Air Temperature Set Point 40023 deg C x10 WR
Temperature Setpoint
S104 Temperature
Air Temperature Proportional Band 40024 deg C x10 WR
Proportional Band
S108 Temperature Dead
Air Temperature Dead Band 40025 deg C x10 WR
Band
Air Temperature Control Integration S105 Temperature
40026 min x10 WR
Time Integration Time
Humidity Set Point 40027 % RH x1 WR U103/S113
Humidity Proportional Band 40028 % RH x1 WR S115
S116 Humidity
Humidity Control Integration Time 40029 min x1 WR
Integration Time
Humidity Dead Band 40030 % RH x10 WR S117
S421 Single Unit Auto
Auto Restart Delay 40031 sec x1 WR
Restart
0 = Proportional
Air Temperature Control Type 40033 x1 WR S103 Control Type 1 = Prop.+Integral
2 = Intelligent
S825 Monitoring
BMS Timeout Period 40045 min x1 WR
Timeout/Handshake
U203/S203 High Return
High Return Air Temperature Threshold 40050 deg C x10 WR
Temperature
U204/S204 Low Return
Low Return Air Temperature Threshold 40051 deg C x10 WR
Temperature
U205/S205 High Return
High Return Humidity Threshold 40054 % RH x10 WR
Humidity
U206/S206 Low Return
Low Return Humidity Threshold 40055 % RH x10 WR
Humidity
Fan Hours Threshold 40070 hr x1 WR U502 Fan Motor(s)
U503 Compressor 1A
Compressor [1A] Hours Threshold 40071 hr x1 WR
Limit
U504 Compressor 2A
Compressor [2A] Hours Threshold 40072 hr x1 WR
Limit
Humidifier Hours Threshold 40073 hr x1 WR U511 Humidifier Limit
U512 Dehumidifier
Dehumidifier Hours Threshold 40074 hr x1 WR
Limit
Free Cooling Valve Hours Threshold 40075 hr x1 WR U506 Free Cool Limit
U508 Electric Heater 1
Electric [1] Reheater Hours Threshold 40076 hr x1 WR
Limit
U509 Electric Heater 2
Electric [2] Reheater Hours Threshold 40077 hr x1 WR
Limit
Electric [3] Reheater Hours Threshold 40078 hr x1 WR U510 Electric Heater 3

17
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Holding
Data Description Unit Scale Access CDL parameter Notes
Register
Limit
Hot Water / Hot Gas Valve Hours U507 HotGas /
40079 hr x1 WR
Threshold HotWater Limit
U502 Fan Motor(s)
Fan Hours 40141 hr x1 WR
Actual Hours
U503 Compressor 1A
Compressor [1A] Hours 40142 hr x1 WR
Actual Hours
U504 Compressor 2A
Compressor [2A] Hours 40143 hr x1 WR
Actual Hours
U511 Humidifier Actual
Humidifier Hours 40144 hr x1 WR
Hours
U512 Dehumidifier
Dehumidifier Hours 40145 hr x1 WR
Actual Hours
U506 Free Cool Actual
Free Cooling Valve Hours 40146 hr x1 WR
Hours
U508 Electric Heater 1
Electric [1] Reheater Hours 40147 hr x1 WR
Actual Hours
U509 Electric Heater 2
Electric [2] Reheater Hours 40148 hr x1 WR
Actual Hours
U510 Electric Heater 3
Electric [3] Reheater Hours 40149 hr x1 WR
Actual Hours
U507 HotGas /
Hot Water / Hot Gas Valve Hours 40150 hr x1 WR
HotWater Actual Hours
0 = Disabled
1 = Limit
Supply Air Temperature Sensor Control 40262 x1 WR S124 Supply Sensor
2 = Control
3 = Cooling Only
Main Unit Screen,
Actual Return Air Temperature Set Point 40263 deg C x10 RO U102/S102
Temperature Setpoint
Main Unit Screen,
Actual Return Humidity Set Point 40264 % RH x1 RO U103/S113 Humidity
Setpoint
Infrared Humidifier Flush Rate 40273 % x1 WR S414 Infrared Flush Rate
0 = Auto,
1 = Manual,
Fan Control Mode 40274 x1 WR S146 VSD Fanspeed
2 = Economy
4 = Delta
0 = Disabled
Customer Input 1 - Event Control 40287 x1 WR S275
1 = Enabled
0 = Message
Customer Input 1 - Event Type 40288 x1 WR S275 1 = Warning
2 = Alarm
0 = Disabled
Customer Input 2 - Event Control 40289 x1 WR S276
1 = Enabled
0 = Message
Customer Input 2 - Event Type 40290 x1 WR S276 1 = Warning
2 = Alarm
0 = Disabled
Customer Input 3 - Event Control 40291 x1 WR S277
1 = Enabled
0 = Message
Customer Input 3 - Event Type 40292 x1 WR S277 1 = Warning
2 = Alarm
0 = Disabled
Customer Input 4 - Event Control 40293 x1 WR S278
1 = Enabled
Customer Input 4 - Event Type 40294 x1 WR S278 0 = Message

18
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Holding
Data Description Unit Scale Access CDL parameter Notes
Register
1 = Warning
2 = Alarm
0 = Disabled
Ext Free Cooling Lockout - Event Control 40295 x1 WR S284
1 = Enabled
0 = Message
Ext Free Cooling Lockout - Event Type 40296 x1 WR S284 1 = Warning
2 = Alarm
Ext Condenser Pump High Water - Event 0 = Disabled
40297 x1 WR S265
Control 1 = Enabled
0 = Message
Ext Condenser Pump High Water - Event
40298 x1 WR S265 1 = Warning
Type
2 = Alarm
Ext Standby Glycol Pump On - Event 0 = Disabled
40299 x1 WR S267
Control 1 = Enabled
0 = Message
Ext Standby Glycol Pump On - Event Type 40300 x1 WR S267 1 = Warning
2 = Alarm
0 = Disabled
Ext Standby Unit On - Event Control 40301 x1 WR S268
1 = Enabled
0 = Message
Ext Standby Unit On - Event Type 40302 x1 WR S268 1 = Warning
2 = Alarm
0 = Disabled
Ext Humidifier Lockout - Event Control 40303 x1 WR S283
1 = Enabled
0 = Message
Ext Humidifier Lockout - Event Type 40304 x1 WR S283 1 = Warning
2 = Alarm
0 = Disabled
Ext Loss of Flow - Event Control 40305 x1 WR S266
1 = Enabled
0 = Message
Ext Loss of Flow - Event Type 40306 x1 WR S266 1 = Warning
2 = Alarm
0 = Disabled
Ext Over Temperature - Event Control 40307 x1 WR S280
1 = Enabled
0 = Message
Ext Over Temperature - Event Type 40308 x1 WR S280 1 = Warning
2 = Alarm
0 = Disabled
Ext Reheat Lockout - Event Control 40309 x1 WR S282
1 = Enabled
0 = Message
Ext Reheat Lockout - Event Type 40310 x1 WR S282 1 = Warning
2 = Alarm
0 = Disabled
High Power Shutdown - Event Control 40311 x1 WR S290
1 = Enabled
0 = Message
High Power Shutdown - Event Type 40312 x1 WR S290 1 = Warning
2 = Alarm
0 = Disabled
Humidifier Issue - Event Control 40313 x1 WR S269
1 = Enabled
0 = Message
Humidifier Issue - Event Type 40314 x1 WR S269 1 = Warning
2 = Alarm
Master Unit Communication Lost - Event 0 = Disabled
40315 x1 WR S270
Control 1 = Enabled
Master Unit Communication Lost - Event 0 = Message
40316 x1 RO S270
Type 1 = Warning

19
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Holding
Data Description Unit Scale Access CDL parameter Notes
Register
2 = Alarm
0 = Disabled
Service Required - Event Control 40317 x1 WR S279
1 = Enabled
0 = Message
Service Required - Event Type 40318 x1 WR S279 1 = Warning
2 = Alarm
Shutdown - Loss Of Power - Event 0 = Disabled
40319 x1 RO S272
Control 1 = Enabled
0 = Message
Shutdown - Loss Of Power - Event Type 40320 x1 WR S272 1 = Warning
2 = Alarm
0 = Disabled
Smoke Detected - Event Control 40321 x1 WR S263
1 = Enabled
0 = Message
Smoke Detected - Event Type 40322 x1 WR S263 1 = Warning
2 = Alarm
0 = Disabled
Water Under Floor - Event Control 40323 x1 WR S264
1 = Enabled
0 = Message
Water Under Floor - Event Type 40324 x1 WR S264 1 = Warning
2 = Alarm
x1 WR 0 = Disabled
Ext Compressor Lockout - Event Control 40325 S285
x1 WR 1 = Enabled
0 = Message
Ext Compressor Lockout - Event Type 40326 x1 WR S285 1 = Warning
2 = Alarm
0 = Disabled
Clogged Air Filter - Event Control 40327 x1 WR S238
1 = Enabled
0 = Message
Clogged Air Filter - Event Type 40328 x1 WR S238 1 = Warning
2 = Alarm
0 = Disabled
Ext Loss of Air Blower - Event Control 40329 x1 WR S281
1 = Enabled
0 = Message
Ext Loss of Air Blower - Event Type 40330 x1 WR S281 1 = Warning
2 = Alarm
Compressor [1] High Head Pressure - 0 = Disabled
40331 x1 WR S251
Event Control 1 = Enabled
Compressor [2] High Head Pressure - 0 = Disabled
40332 x1 WR S251
Event Control 1 = Enabled
0 = Message
Compressor [1] High Head Pressure -
40333 x1 WR S251 1 = Warning
Event Type
2 = Alarm
0 = Message
Compressor [2] High Head Pressure -
40334 x1 WR S252 1 = Warning
Event Type
2 = Alarm
Compressor [1] Low Suction Pressure - 0 = Disabled
40335 x1 WR S253
Event Control 1 = Enabled
Compressor [2] Low Suction Pressure - 0 = Disabled
40336 x1 WR S254
Event Control 1 = Enabled
0 = Message
Compressor [1] Low Suction Pressure -
40337 x1 WR S253 1 = Warning
Event Type
2 = Alarm
0 = Message
Compressor [2] Low Suction Pressure -
40338 x1 WR S254 1 = Warning
Event Type
2 = Alarm

20
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Holding
Data Description Unit Scale Access CDL parameter Notes
Register
Compressor [1] Short Cycle - Event 0 = Disabled
40343 x1 WR S288
Control 1 = Enabled
Compressor [2] Short Cycle - Event 0 = Disabled
40344 x1 WR S289
Control 1 = Enabled
0 = Message
Compressor [1] Short Cycle - Event Type 40345 x1 WR S288 1 = Warning
2 = Alarm
0 = Message
Compressor [2] Short Cycle - Event Type 40346 x1 WR S289 1 = Warning
2 = Alarm
Compressor [1] Thermal Overload - 0 = Disabled
40347 x1 WR S249
Event Control 1 = Enabled
Compressor [2] Thermal Overload - 0 = Disabled
40348 x1 WR S250
Event Control 1 = Enabled
0 = Message
Compressor [1] Thermal Overload -
40349 x1 WR S249 1 = Warning
Event Type
2 = Alarm
0 = Message
Compressor [2] Thermal Overload -
40350 x1 WR S250 1 = Warning
Event Type
2 = Alarm
Dig Scroll Comp [1] Discharge Over Temp 0 = Disabled
40351 x1 WR S257
- Event Ctrl 1 = Enabled
Dig Scroll Comp [2] Discharge Over Temp 0 = Disabled
40352 x1 WR S258
- Event Ctrl 1 = Enabled
0 = Message
Dig Scroll Comp [1] Discharge Over Temp
40353 x1 WR S257 1 = Warning
- Event Type
2 = Alarm
0 = Message
Dig Scroll Comp [2] Discharge Over Temp
40354 x1 WR S258 1 = Warning
- Event Type
2 = Alarm
0 = Disabled
High Return Humidity - Event Control 40363 x1 WR S241/S202
1 = Enabled
0 = Message
High Return Humidity - Event Type 40364 x1 RO S241 1 = Warning
2 = Alarm
0 = Disabled
Low Return Humidity - Event Control 40365 x1 WR S241/S202
1 = Enabled
0 = Message
Low Return Humidity - Event Type 40366 x1 RO S241 1 = Warning
2 = Alarm
0 = Disabled
Return Air Over Temp - Event Control 40367 x1 WR S239/S202
1 = Enabled
0 = Message
Return Air Over Temp - Event Type 40368 x1 RO S239 1 = Warning
2 = Alarm
0 = Disabled
Return Air Under Temp - Event Control 40369 x1 WR S240/S202
1 = Enabled
0 = Message
Return Air Under Temp - Event Type 40370 x1 RO S240 1 = Warning
2 = Alarm
0 = Disabled
Fan Hours Exceeded - Event Control 40371 x1 WR S262
1 = Enabled
0 = Message
Fan Hours Exceeded - Event Type 40372 x1 RO S262 1 = Warning
2 = Alarm
Fan Issue - Event Control 40373 x1 WR S237 Loss of Airflow 0 = Disabled

21
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Holding
Data Description Unit Scale Access CDL parameter Notes
Register
1 = Enabled
0 = Disabled
Main Fan Overload - Event Control 40375 x1 WR S236
1 = Enabled
0 = Message
Main Fan Overload - Event Type 40376 x1 WR S236 1 = Warning
2 = Alarm
S291 Condenser 1 0 = Disabled
Condenser [1] Issue - Event Control 40377 x1 WR
Failure 1 = Enabled
S292 Condenser 2 0 = Disabled
Condenser [2] Issue - Event Control 40378 x1 WR
Failure 1 = Enabled
0 = Message
S291 Condenser 1
Condenser [1] Issue - Event Type 40379 x1 WR 1 = Warning
Failure
2 = Alarm
0 = Message
S292 Condenser 2
Condenser [2] Issue - Event Type 40380 x1 WR 1 = Warning
Failure
2 = Alarm
2 = Reset
System Event Acknowledge/Reset 40381 x1 WR
4 = Acknowledge
0 = Relative
S114 Humidity Control 1 = Compensated
Humidity Control Type 40485 x1 WR
Type 2= Predicted
3= Dew Point
Dew Point Set Point 40503 deg C x10 WR S102
Chilled Water [1] Valve Hours 40563 hr x1 RO U505 Chilled Water 1/2
Static Pressure Set Point 40672 Pa x10 RO AA07
U106/S125 Supply
Supply Air Temperature Set Point 40733 deg F x10 WR
Setpoint
S138 DT2
Free Cooling Internal Temperature Delta 40734 deg F x10 WR
(Room / FC Fluid) Value
S140 Minimum CW
Minimum Chilled Water Temp Set Point 40735 deg F x10 WR
Temp Value
U102/S102
Air Temperature Set Point 40736 deg F x10 WR
Temperature Setpoint
S104 Temperature
Air Temperature Proportional Band 40737 deg F x10 WR
Proportional Band
S108 Temperature Dead
Air Temperature Dead Band 40738 deg F x10 WR
Band
U203/S203 High Return
High Return Air Temperature Threshold 40739 deg F x10 WR
Temperature
U204/S204 Low Return
Low Return Air Temperature Threshold 40740 deg F x10 WR
Temperature
Main Unit Screen,
Actual Return Air Temperature Set Point 40754 deg F x10 RO U102/S102
Temperature Setpoint
Dew Point Set Point 40764 deg F x10 RO S102
# Registers (2)
Energy Consumption 40870 kWH x1 WR S3A3 (5th column)
Power Meter #1
Compressor [1A] Hours 41340 hr x1 RO U503 Compressor 1A # Registers (2)
Compressor [2A] Hours 41342 hr x1 RO U504 Compressor 2A # Registers (2)
Free Cooling Valve Hours 41346 hr x1 RO U506 Free Cool # Registers (2)
U507 HotGas /
Hot Water / Hot Gas Valve Hours 41348 hr x1 RO # Registers (2)
HotWater
Electric Reheater [1] Hours 41350 hr x1 RO U508 Electric Heater 1 # Registers (2)
Electric Reheater [2] Hours 41352 hr x1 RO U509 Electric Heater 2 # Registers (2)
Electric Reheater [3] Hours 41354 hr x1 RO U510 Electric Heater 3 # Registers (2)

22
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Holding
Data Description Unit Scale Access CDL parameter Notes
Register
Humidifier Hours 41356 hr x1 RO U511 Humidifier # Registers (2)
Dehumidifier Hours 41358 hr x1 RO U512 Dehumidification # Registers (2)
Fan Hours 41360 hr x1 RO U507 Fan Motor(s) # Registers (2)
Static Pressure Set Point 41370 inWC x1000 RO AA07
Dew Point Proportional Band 40380 deg C x10 RW S104
Dew Point Proportional Band 40382 deg F x10 RW S104
Dew Point Dead Band 40384 deg C x10 RW S108
Dew Point Dead Band 40386 deg F x10 RW S108
0 = Disabled
Underfloor Static Pressure Control AA02 Underfloor Static
41400 - x1 RW 1 = Enabled
Enable Pressure
2= Visualiz. Only
Chilled Water [2] Valve Hours 41430 hr x1 RO U505 Chilled Water 1/2
Main Valve 48077 x1 RW S430 0 = PS1, 1 = PS2
0 = Disabled
Fan Speed Delta Control 48078 x1 RW S168
1 = Enabled
0 = Single,
1 = 2 Parallel,
CW Valve Control 48079 x1 RW S429
2 = 2 Alternate,
3 = 2 Cascade
Main Unit Screen, # Registers (2)
System Date and Time 49998 x1 WR
U402, U403 Unix Time Stamp

23
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

BACNET
BACnet Analog Values
Data Description Object Id Object Name CDL parameter Notes
U102/S102
Air Temperature Set Point (Air) AV-1 5008_1 Temperature Deg C
Setpoint
S104 Temperature
Air Temperature Proportional Band (Air) AV-2 5325_1 Deg C
Proportional Band
S108 Temperature
Air Temperature Dead Band (Air) AV-3 5011_1 Deg C
Dead Band
S105 Temperature
Air Temperature Control Integration Time (Air) AV-4 5326_1 min
Integration Time
Today's High Air Temperature (Air) AV-5 5327_1 U313 Deg C
Today's High Air Temperature Time (Air) AV-6 5328_1 U313 sec
Today's Low Air Temperature (Air) AV-7 5329_1 U314 Deg C
Today's Low Air Temperature Time (Air) AV-8 5330_1 U314 sec
Main Unit Screen,
Supply Air Temperature (Air->Supply Air) AV-19 5002_1_1 Deg C
S629
U106/S125 Supply
Supply Air Temperature Set Point (Air->Supply Air) AV-20 5331_1_1 Deg C
Setpoint
Main Unit Screen,
Return Air Temperature (Air->Return Air) AV-31 4291_1_1 Deg C
S603
U102/S102
Actual Return Air Temperature Set Point (Air->Return Air) AV-32 5333_1_1 Temperature Deg C
Setpoint
U203/S203 High
High Return Air Temperature Threshold (Air->Return Air) AV-33 5022_1_1 Return Deg C
Temperature
U204/S204 Low
Low Return Air Temperature Threshold (Air->Return Air) AV-34 5334_1_1 Return Deg C
Temperature
Optional Sensor A1
Ext Air Sensor A Temperature (Air->External Sensors) AV-45 4594_1_1 Deg C
U301/S614
Optional Sensor B1
Ext Air Sensor B Temperature (Air->External Sensors) AV-46 4597_1_1 Deg C
U303/S619
Optional Sensor C1
Ext Air Sensor C Temperature (Air->External Sensors) AV-47 5336_1_1 Deg C
U305/S631
Outside Air Temperature (Air->External Sensors) AV-50 5574_1_1 U308 Deg C
Main Unit Screen,
Return Humidity (Humidity) AV-60 5028_1 % RH
S605
Main Unit Screen,
Humidity Set Point (Humidity) AV-61 5029_1 U103/S113 % RH
Humidity Setpoint
Main Unit Screen,
Actual Return Humidity Set Point (Humidity) AV-62 5339_1 U103/S113 % RH
Humidity Setpoint
Humidity Proportional Band (Humidity) AV-63 5341_1 S115 % RH
Humidity Dead Band (Humidity) AV-64 5032_1 S117 % RH
S116 Humidity
Humidity Control Integration Time (Humidity) AV-65 5342_1 min
Integration Time
U205/S205 High
High Return Humidity Threshold (Humidity) AV-66 5033_1 % RH
Return Humidity
U206/S206 Low
Low Return Humidity Threshold (Humidity) AV-67 5035_1 % RH
Return Humidity
24
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name CDL parameter Notes
U315 Daily High
Today's High Humidity (Humidity) AV-68 5343_1 % RH
Humidity
Today's High Humidity Time (Humidity) AV-69 5344_1 U315 sec
U316 Daily Low
Today's Low Humidity (Humidity) AV-70 5345_1 % RH
Humidity
Today's Low Humidity Time (Humidity) AV-71 5346_1 U316 sec
Dew Point Proportional Band (Humidity) AV-72 6258_1 S104
Dew Point Dead Band (Humidity) AV-73 6259_1 S108
Optional Sensor A2
Ext Air Sensor A Humidity (Humidity->External Sensors) AV-82 4595_1_1 % RH
U302/S616
Optional Sensor B2
Ext Air Sensor B Humidity (Humidity->External Sensors) AV-83 4598_1_1 % RH
U304/S621
Optional Sensor C2
Ext Air Sensor C Humidity (Humidity->External Sensors) AV-84 5347_1_1 % RH
U306/S633
U503 Compressor
Compressor Hours (Compressors->Compressor [1A]) AV-97 5267_1_1
1A Actual Hours
Compressor Hours Threshold (Compressors->Compressor U503 Compressor
AV-98 5268_1_1
[1A]) 1A Limit
Dig Scroll Comp Discharge Temp (Compressors- U310 DigiScroll 1
AV-99 5353_1_1 Deg C
>Compressor [1]) Temperarute
Compressor Discharge Pressure (Compressors- S310 Actual HP1
AV-102 6517_1_1 Pa
>Compressor [1]) Pressure
U504 Compressor
Compressor Hours (Compressors->Compressor [2A]) AV-110 5267_1_2
2A Actual Hours
Compressor Hours Threshold (Compressors->Compressor U504 Compressor
AV-111 5268_1_2
[2A]) 2A Limit
Dig Scroll Comp Discharge Temp (Compressors- U311 DigiScroll 2
AV-112 5353_1_2 Deg C
>Compressor [2]) Temperarute
Compressor Discharge Pressure (Compressors- S311 Actual HP2
AV-115 6517_1_2 Pa
>Compressor [2]) Pressure
S138 DT2
Free Cooling Internal Temperature Delta (Free Cooling) AV-123 5356_1 (Room / FC Fluid) K
Value
Free Cooling Fluid Temperature (Free Cooling) AV-124 5358_1 U307/S626 Deg C
S140 Minimum CW
Minimum Chilled Water Temp Set Point (Free Cooling) AV-125 5360_1 Deg C
Temp Value
U506 Free Cool
Free Cooling Valve Hours (Free Cooling) AV-126 5304_1
Actual Hours
U506 Free Cool
Free Cooling Valve Hours Threshold (Free Cooling) AV-127 5305_1
Limit
U507 HotGas /
Hot Water / Hot Gas Valve Hours (Reheat) AV-138 5363_1 HotWater Actual
Hours
U507 HotGas /
Hot Water / Hot Gas Valve Hours Threshold (Reheat) AV-139 5364_1
HotWater Limit
U508 Electric
Electric Reheater Hours (Reheat->Electric Reheater [1]) AV-150 5366_1_1 Heater 1 Actual
Hours
Electric Reheater Hours Threshold (Reheat->Electric U508 Electric
AV-151 5367_1_1
Reheater [1]) Heater 1 Limit
U509 Electric
Electric Reheater Hours (Reheat->Electric Reheater [2]) AV-162 5366_1_2 Heater 2 Actual
Hours
Electric Reheater Hours Threshold (Reheat->Electric U509 Electric
AV-163 5367_1_2
Reheater [2]) Heater 2 Limit
U510 Electric
Electric Reheater Hours (Reheat->Electric Reheater [3]) AV-174 5366_1_3
Heater 3 Actual

25
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name CDL parameter Notes
Hours
Electric Reheater Hours Threshold (Reheat->Electric U510 Electric
AV-175 5367_1_3
Reheater [3]) Heater 3 Limit
U511 Humidifier
Humidifier Hours (Humidifier) AV-186 5369_1
Actual Hours
U511 Humidifier
Humidifier Hours Threshold (Humidifier) AV-187 5370_1
Limit
S414 Infrared Flush
Infrared Humidifier Flush Rate (Humidifier) AV-188 5445_1 %
Rate
U512 Dehumidifier
Dehumidifier Hours (Dehumidifier) AV-199 5371_1
Actual Hours
U512 Dehumidifier
Dehumidifier Hours Threshold (Dehumidifier) AV-200 5372_1
Limit
S148 VSD Setpoint
Fan Speed Maximum Set Point (Fan) AV-211 5050_1 %
STD
U502 Fan Motor(s)
Fan Hours (Fan) AV-212 5374_1
Actual hours
Fan Hours Threshold (Fan) AV-213 5375_1 U502 Fan Motor(s)
Analog Input Reading (Analog Inputs [1]) AV-224 5378_1 A688
Analog Input Reading (Analog Inputs [2]) AV-235 5378_2 A689
Analog Input Reading (Analog Inputs [3]) AV-246 5378_3 A690
Analog Input Reading (Analog Inputs [4]) AV-257 5378_4 A691
S825 Monitoring
BMS Timeout Period (System Info) AV-268 5075_1 Timeout/Handshak
e
S421 Single Unit
Auto Restart Delay (System Info) AV-269 4710_1 sec
Auto Restart
Fan Speed (System Operations) AV-280 5077_1 Main Unit Screen %
Compressor/ CW Valve Utilization (System Operations) AV-281 5078_1 Main Unit Screen %
Main Unit Screen:
Free Cooling Valve Open Position (System Operations) AV-282 5379_1 %
FC
Maintenance Ramp (System Operations) AV-283 4870_1 Main Unit Screen %
Main Unit Screen,
Calculated Next Maintenance Month (System Operations) AV-284 4868_1 Calculated Next
Maintenance S008
Main Unit Screen,
Calculated Next Maintenance Year (System Operations) AV-285 4869_1 Calculated Next
Maintenance S008
Hot Water / Hot Gas Valve Open Position (System
AV-286 5380_1 Main Unit Screen %
Operations)
Reheat Utilization (System Operations) AV-287 5080_1 Main Unit Screen %
Humidifier Utilization (System Operations) AV-288 5081_1 Main Unit Screen %
Dehumidifier Utilization (System Operations) AV-289 5079_1 Main Unit Screen %
Main Unit Screen,
Adjusted Humidity (System Operations) AV-291 5606_1 % RH
S605
Return Dew Point (Humidity) AV-292 5004_1 Main Unit Screen Deg C
Dew Point Set Point (Humidity) AV-295 5575_1 S102 Deg C
Main Unit Screen, Unix Time
System Date and Time (Time) AV-300 4293_1
U402, U403 Stamp
Static Pressure Set Point (PCW-PDX) AV-461 5626_1 AA07 Pa
AA06 Actual FP1
System Static Pressure (PCW-PDX) AV-463 5628_1 Pa
Pressure
System Input RMS A-N (Power Measurement) AV-810 4096_1 S3A2 (2nd column) VAC
System Input RMS B-N (Power Measurement) AV-811 4098_1 S3A2 (3rd column) VAC
System Input RMS C-N (Power Measurement) AV-812 4100_1 S3A2 (4th column) VAC
System Input RMS Current Phase A (Power AV-813 4113_1 S3A3 (2nd column) A AC

26
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name CDL parameter Notes
Measurement)
System Input RMS Current Phase B (Power
AV-814 4114_1 S3A3 (3rd column) A AC
Measurement)
System Input RMS Current Phase C (Power
AV-815 4115_1 S3A3 (4th column) A AC
Measurement)
Instantaneous Power (Power Measurement) AV-816 5901_1 S3A2 (5th column) W
Energy Consumption (Power Measurement) AV-817 5900_1 S3A3 (5th column) kWH
Fluid Flow Rate (Chilled Water->Chilled Water Circuit [1]) AV-881 5899_1_1_l/min U319 l/min
Fluid Flow Rate (Chilled Water->Chilled Water Circuit [1]) AV-891 5899_1_2_l/min U319 l/min
System Input RMS A-B (Power Measurement) AV-1900 4097_1 S3A1 (2nd column) W
System Input RMS B-C (Power Measurement) AV-1901 4099_1 S3A1 (3rd column) VAC
System Input RMS C-A (Power Measurement) AV-1902 4101_1 S3A1 (4th column) VAC
SB44 Value Sent to
Actual Cold Aisle Humidity (PCW-PDX->Cold Aisle) AV-2044 6085_1_1 % RH
Master
SB55 Value Sent to
Actual Cold Aisle Temperature (PCW-PDX->Cold Aisle) AV-2045 6086_1_1 Deg C
Master
Cold Aisle Cascade Fan Speed Max Set Point (PCW-PDX- SB19 Cascade VSD
AV-2046 6087_1_1 %
>Cold Aisle) Limit
Cold Aisle Fan Speed Min Set Point (PCW-PDX->Cold SB17 VSD Fanspeed
AV-2047 6088_1_1 %
Aisle) Min
Cold Aisle Fan Speed Max Set Point (PCW-PDX->Cold SB18 VSD Fanspeed
AV-2048 6089_1_1 %
Aisle) Max
A161 Min Hum
Humidification Fan Speed Min Set Point (PCW-PDX) AV-2049 6096_1 %
Fanspeed
A161 Min Heat
Heating Fan Speed Min Set Point (PCW-PDX) AV-2050 6097_1 %
Fanspeed
A161 Min Dehum
Dehumidification Fan Speed Min Set Point (PCW-PDX) AV-2051 6098_1 %
Fanspeed
Back Draft Control Fan Speed (PCW-PDX) AV-2052 6099_1 S150 %
AA41, U324 Air
Air Filter Differential Pressure (PCW-PDX) AV-2053 6302_1 Differential Pa
Pressure
Super Saver Call For Cooling (CApCom) AV-2100 6234_1 Main unit Screen %
Static Pressure Set Point (PCW-PDX) AV-2121 5626_1_inWC AA07 inWC
AA06 Actual FP1
System Static Pressure (PCW-PDX) AV-2123 5628_1_inWC inWC
Pressure
Cold Aisle Sensor Air Temperature (PCW-PDX->Cold Aisle- SB37 Calibrated
AV-2147 6307_1_1_1 Deg C
>Cold Aisle Sensor [1]) Remote THB 1
Cold Aisle Sensor Humidity (PCW-PDX->Cold Aisle->Cold SB48 Calibrated
AV-2148 6308_1_1_1 % RH
Aisle Sensor [1]) Remote THB 1
Cold Aisle Sensor Air Temperature (PCW-PDX->Cold Aisle- SB40 Calibrated
AV-2159 6307_1_1_2 Deg C
>Cold Aisle Sensor [2]) Remote THB 2
Cold Aisle Sensor Humidity (PCW-PDX->Cold Aisle->Cold SB51 Calibrated
AV-2160 6308_1_1_2 % RH
Aisle Sensor [2]) Remote THB 2
Cold Aisle Sensor Air Temperature (PCW-PDX->Cold Aisle- SB43 Calibrated
AV-2171 6307_1_1_3 Deg C
>Cold Aisle Sensor [3]) Remote THB 3
Cold Aisle Sensor Humidity (PCW-PDX->Cold Aisle->Cold SB54 Calibrated
AV-2172 6308_1_1_3 % RH
Aisle Sensor [3]) Remote THB 3
Chilled Water Inlet Temperature (Chilled Water->Chilled U317 Inlet Water
AV-2189 6311_1_1 deg C
Water Circuit [1]) Temperature
Chilled Water Outlet Temperature (Chilled Water- U318 Outlet Water
AV-2190 6312_1_1 deg C
>Chilled Water Circuit [1]) Temperature
A197 Total Cooling
Cooling Capacity (Chilled Water->Chilled Water Circuit Gross Capacity,
AV-2191 5491_1_1 kW
[1]) U320 Cool Gross
Cap.

27
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name CDL parameter Notes
Chilled Water Valve Hours (Chilled Water->Chilled Water U505 Chilled Water
AV-2192 5614_1_1 hr
Circuit [1]) 1/2
U317 Inlet Water
Chilled Water Inlet Temperature (Chilled Water->Chilled Temperature
AV-2201 6311_1_2 deg C
Water Circuit [2]) (as B1/2T sensor,
U303)
U318 Outlet Water
Chilled Water Outlet Temperature (Chilled Water- Temperature
AV-2202 6312_1_2 deg C
>Chilled Water Circuit [2]) (as B2/2T sensor,
U304)
A197 Total Cooling
Cooling Capacity (Chilled Water->Chilled Water Circuit Gross Capacity,
AV-2203 5491_1_2 kW
[2]) U320 Cool Gross
Cap.
Chilled Water Valve Hours (Chilled Water->Chilled Water U505 Chilled Water
AV-2204 5614_1_2 hr
Circuit [2]) 1/2
U324 Air
Air Filter Differential Pressure (PCW-PDX) AV-2213 6302_1_inWC Differential inWC
Pressure
Customer Configurable Analog Output Value (Analog
AV-2215 6520_1 S341, A163 %
Output [1])
Customer Configurable Analog Output Value (Analog
AV-2226 6520_2 S342, A164 %
Output [2])
Customer Configurable Analog Output Value (Analog
AV-2237 6520_3 S343, A165 %
Output [3])
Customer Configurable Analog Output Value (Analog
AV-2248 6520_4 S344, A166 %
Output [4])
U102/S102
Air Temperature Set Point (Air) AV-10001 5008_1_deg_F Temperature Deg F
Setpoint
S104 Temperature
Air Temperature Proportional Band (Air) AV-10002 5325_1_deg_F Deg F
Proportional Band
S108 Temperature
Air Temperature Dead Band (Air) AV-10003 5011_1_deg_F Deg F
Dead Band
Today's High Air Temperature (Air) AV-10005 5327_1_deg_F U313 Deg F
Today's Low Air Temperature (Air) AV-10007 5329_1_deg_F U314 Deg F
Main Unit Screen,
Supply Air Temperature (Air->Supply Air) AV-10019 5002_1_1_deg_F Deg F
S629
U106/S125 Supply
Supply Air Temperature Set Point (Air->Supply Air) AV-10020 5331_1_1_deg_F Deg F
Setpoint
Main Unit Screen,
Return Air Temperature (Air->Return Air) AV-10031 4291_1_1_deg_F Deg F
S603
U102/S102
Actual Return Air Temperature Set Point (Air->Return Air) AV-10032 5333_1_1_deg_F Temperature Deg F
Setpoint
U203/S203 High
High Return Air Temperature Threshold (Air->Return Air) AV-10033 5022_1_1_deg_F Return Deg F
Temperature
U204/S204 Low
Low Return Air Temperature Threshold (Air->Return Air) AV-10034 5334_1_1_deg_F Return Deg F
Temperature
Optional Sensor A1
Ext Air Sensor A Temperature (Air->External Sensors) AV-10045 4594_1_1_deg_F Deg F
U301/S614
Optional Sensor B1
Ext Air Sensor B Temperature (Air->External Sensors) AV-10046 4597_1_1_deg_F Deg F
U303/S619
Optional Sensor C1
Ext Air Sensor C Temperature (Air->External Sensors) AV-10047 5336_1_1_deg_F Deg F
U305/S631

28
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name CDL parameter Notes
Dew Point Proportional Band (Humidity) AV-10072 6258_1_deg_F S104 Deg F
Dew Point Dead Band (Humidity) AV-10073 6259_1_deg_F S108 Deg F
U310/S607
Dig Scroll Comp Discharge Temp (Compressors-
AV-10099 5353_1_1_deg_F DigiScroll 1 Deg F
>Compressor [1])
Temperature
U311/S609
Dig Scroll Comp Discharge Temp (Compressors-
AV-10112 5353_1_2_deg_F DigiScroll 2 Deg F
>Compressor [2])
Temperature
S138 DT2 (Room /
Free Cooling Internal Temperature Delta (Free Cooling) AV-10123 5356_1_deg_F Deg F
FC Fluid) Value
Free Cooling Fluid Temperature (Free Cooling) AV-10124 5358_1_deg_F U307/S626 Deg F
S140 Minimum CW
Minimum Chilled Water Temp Set Point (Free Cooling) AV-10125 5360_1_deg_F Deg F
Temp Value
Return Dew Point (Humidity) AV-10292 5004_1_deg_F Main Unit Screen Deg F
Dew Point Set Point (Humidity) AV-10295 5575_1_deg_F S102 Deg F
SB44 Value Sent to
Actual Cold Aisle Temperature (PCW-PDX->Cold Aisle) AV-12045 6086_1_1_deg_F Deg F
Master
Cold Aisle Sensor Air Temperature (PCW-PDX->Cold Aisle- SB37 Calibrated
AV-12147 6307_1_1_1_deg_F Deg F
>Cold Aisle Sensor [1]) Remote THB 1
Cold Aisle Sensor Air Temperature (PCW-PDX->Cold Aisle- SB40 Calibrated
AV-12159 6307_1_1_2_deg_F Deg F
>Cold Aisle Sensor [2]) Remote THB 2
Cold Aisle Sensor Air Temperature (PCW-PDX->Cold Aisle- SB43 Calibrated
AV-12171 6307_1_1_3_deg_F Deg F
>Cold Aisle Sensor [3]) Remote THB 3
Chilled Water Inlet Temperature (Chilled Water->Chilled U317 Inlet Water
AV-12189 6311_1_1_deg_F Deg F
Water Circuit [1]) Temperature
Chilled Water Outlet Temperature (Chilled Water- U318 Outlet Water
AV-12190 6312_1_1_deg_F Deg F
>Chilled Water Circuit [1]) Temperature
U317 Inlet Water
Chilled Water Inlet Temperature (Chilled Water->Chilled Temperature
AV-12201 6311_1_2_deg_F Deg F
Water Circuit [2]) (as B1/2T sensor,
U303)
U318 Outlet Water
Chilled Water Outlet Temperature (Chilled Water- Temperature
AV-12202 6312_1_2_deg_F Deg F
>Chilled Water Circuit [2]) (as B2/2T sensor,
U304)
0 = MAN;
MAN-OFF-AUTO Switch AV-18005 5671_1 1 = OFF;
2 = AUTO
Condenser 1 Ambient Outside Air Temperature (Liebert 1/100 °C
AV-18006 5672_1 AB12
Condensers)
Condenser 2 Ambient Outside Air Temperature (Liebert 1/100 °C
AV-18007 5673_1 AB12
Condensers)
1 = Off
2 = Ok
3 = Wait
Power Meter Status (Power Measurement) AV-18009 5675_1 S3A2 (1st column)
4 = ECom
5 = ENC
6 = Ecfg
Actual Compressor 1 Suction Pressure (Compressors) AV-18010 5676_1 S308 bar
Actual Compressor 1 Suction Pressure (Compressors) AV-18011 5677_1 S309 bar
0=Valve 1
Main Valve (Chilled Water) AV-18051 5717_1 S430
1=Valve 2
0=Disabled
Fan Speed Delta Control (Fan) AV-18052 5718_1 S168
1=Enabled
0 = Single,
CW Valve Control (Chilled Water) AV-18053 5719_1 S429 1 = 2 Paral,
2 = 2 Alter,

29
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name CDL parameter Notes
3 = 2 Casc

BACnet Binary Values


Object
Data Description Object Id Notes
Name
Supply Air Over Temperature (Air->Supply Air) BV-1 5015_1_1 Active on Event
Supply Air Under Temperature (Air->Supply Air) BV-2 5019_1_1 Active on Event
Supply Air Sensor Issue (Air->Supply Air) BV-3 5026_1_1 Active on Event
Return Air Over Temperature (Air->Return Air) BV-14 5023_1_1 Active on Event
Return Air Under Temperature (Air->Return Air) BV-15 5335_1_1 Active on Event
Return Air Sensor Issue (Air->Return Air) BV-16 5147_1_1 Active on Event
Ambient Air Sensor Issue (Air->External Sensors) BV-30 5573_1_1 Active on Event
High Return Humidity (Humidity) BV-41 5034_1 Active on Event
Low Return Humidity (Humidity) BV-42 5036_1 Active on Event
Dew Point Over Temperature (Humidity) BV-43 4615_1 Active on Event
Dew Point Under Temperature (Humidity) BV-44 5579_1 Active on Event
Ext Dew Point Over Temperature (Humidity) BV-55 5349_1_1 Active on Event
Ext Dew Point Under Temperature (Humidity) BV-56 5577_1 Active on Event
Ext Compressor Lockout (Compressors) BV-65 5067_1 Active on Event
Compressor Capacity Reduced (Compressors) BV-66 5513_1 Active on Event
Compressor Hours Exceeded (Compressors->Compressor [1]) BV-77 5269_1_1 Active on Event
Compressor High Head Pressure (Compressors->Compressor [1]) BV-78 5270_1_1 Active on Event
Compressor Low Suction Pressure (Compressors->Compressor [1]) BV-79 5271_1_1 Active on Event
Compressor Short Cycle (Compressors->Compressor [1]) BV-80 5352_1_1 Active on Event
Compressor Thermal Overload (Compressors->Compressor [1]) BV-82 5272_1_1 Active on Event
Dig Scroll Comp Discharge Temp Sensor Issue (Compressors->Compressor
BV-83 5354_1_1 Active on Event
[1])
Dig Scroll Comp Over Temp (Compressors->Compressor [1]) BV-84 5355_1_1 Active on Event
Compressor Low Pressure Transducer Issue (Compressors->Compressor
BV-85 5514_1_1 Active on Event
[1])
Compressor High Pressure Transducer Issue (Compressors->Compressor
BV-86 5148_1_1 Active on Event
[1])
Compressor Hours Exceeded (Compressors->Compressor [2]) BV-97 5269_1_2 Active on Event
Compressor High Head Pressure (Compressors->Compressor [2]) BV-98 5270_1_2 Active on Event
Compressor Low Suction Pressure (Compressors->Compressor [2]) BV-99 5271_1_2 Active on Event
Compressor Short Cycle (Compressors->Compressor [2]) BV-100 5352_1_2 Active on Event
Compressor Thermal Overload (Compressors->Compressor [2]) BV-102 5272_1_2 Active on Event
Dig Scroll Comp Discharge Temp Sensor Issue (Compressors->Compressor
BV-103 5354_1_2 Active on Event
[2])
Dig Scroll Comp Over Temp (Compressors->Compressor [2]) BV-104 5355_1_2 Active on Event
Compressor Low Pressure Transducer Issue (Compressors->Compressor
BV-105 5514_1_2 Active on Event
[2])
Compressor High Pressure Transducer Issue (Compressors->Compressor
BV-106 5148_1_2 Active on Event
[2])
Free Cooling Valve Hours Exceeded (Free Cooling) BV-117 5306_1 Active on Event
Ext Free Cooling Lockout (Free Cooling) BV-118 5361_1 Active on Event
Free Cooling Temp Sensor Issue (Free Cooling) BV-119 5362_1 Active on Event
Hot Water / Hot Gas Valve Hours Exceeded (Reheat) BV-130 5365_1 Active on Event
Reheater Over Temperature (Reheat) BV-131 5068_1 Active on Event
Ext Reheat Lockout (Reheat) BV-132 5070_1 Active on Event
Electric Reheater Hours Exceeded (Reheat->Electric Reheater [1]) BV-143 5368_1_1 Active on Event
Electric Reheater Hours Exceeded (Reheat->Electric Reheater [2]) BV-154 5368_1_2 Active on Event
Electric Reheater Hours Exceeded (Reheat->Electric Reheater [3]) BV-165 5368_1_3 Active on Event

30
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Object
Data Description Object Id Notes
Name
Humidifier Hours Exceeded (Humidifier) BV-176 5037_1 Active on Event
Ext Humidifier Lockout (Humidifier) BV-177 5044_1 Active on Event
Humidifier Control Board Not Detected (Humidifier) BV-178 5045_1 Active on Event
Humidifier Cylinder Worn (Humidifier) BV-179 5042_1 Active on Event
Humidifier Issue (Humidifier) BV-180 5043_1 Active on Event
Humidifier Low Water (Humidifier) BV-181 5041_1 Active on Event
Humidifier Over Current (Humidifier) BV-182 5040_1 Active on Event
Humidifier Under Current (Humidifier) BV-183 5039_1 Active on Event
Dehumidifier Hours Exceeded (Dehumidifier) BV-194 5038_1 Active on Event
Fan Hours Exceeded (Fan) BV-205 5054_1 Active on Event
Main Fan Overload (Fan) BV-206 5376_1 Active on Event
Ext Condenser Pump High Water (Condensers) BV-220 5106_1 Active on Event
Condenser Issue (Condensers->Condenser [1]) BV-231 5377_1_1 Active on Event
Condenser Issue (Condensers->Condenser [2]) BV-242 5377_1_2 Active on Event
Customer Input 1 (System Events) BV-253 4270_1 Active on Event
Customer Input 2 (System Events) BV-254 4271_1 Active on Event
Customer Input 3 (System Events) BV-255 4272_1 Active on Event
Customer Input 4 (System Events) BV-256 4273_1 Active on Event
Ext Loss of Air Blower (System Events) BV-257 5415_1 Active on Event
Ext Loss of Flow (System Events) BV-258 5105_1 Active on Event
BMS Communications Timeout (System Events) BV-260 5115_1 Active on Event
Ext Standby Unit On (System Events) BV-261 5416_1 Active on Event
Clogged Air Filter (System Events) BV-262 5118_1 Active on Event
Loss of Air Flow (System Events) BV-263 5053_1 Active on Event
Master Unit Communication Lost (System Events) BV-265 5120_1 Active on Event
RAM Battery Issue (System Events) BV-266 5119_1 Active on Event
Shutdown - Loss Of Power (System Events) BV-267 4714_1 Active on Event
High Power Shutdown (System Events) BV-268 5121_1 Active on Event
Smoke Detected (System Events) BV-269 4720_1 Active on Event
Supply Chilled Water Loss of Flow (System Events) BV-270 4980_1 Active on Event
Supply Chilled Water Over Temp (System Events) BV-271 4626_1 Active on Event
Unit Code Missing (System Events) BV-272 5418_1 Active on Event
Unit Communication Lost (System Events) BV-273 5419_1 Active on Event
Water Leakage Detector Sensor Issue (System Events) BV-274 5114_1 Active on Event
Water Under Floor (System Events) BV-275 4723_1 Active on Event
Ext Over Temperature (System Events) BV-276 5104_1 Active on Event
External Fire Detected (System Events) BV-277 5108_1 Active on Event
Ext Air Damper Position Issue (PCW-PDX) BV-281 5907_1 Active on Event
Unit Off (System Events->Messages) BV-310 5110_1_1 Active on Event
Unit On (System Events->Messages) BV-311 5109_1_1 Active on Event
Unit Partial Shutdown (System Events->Messages) BV-312 5112_1_1 Active on Event
Unit Shutdown (System Events->Messages) BV-313 5113_1_1 Active on Event
Unit Standby (System Events->Messages) BV-314 5111_1_1 Active on Event
Digital Output Board Not Detected (System Events->iCOM DO Board [1]) BV-327 5417_1_1 Active on Event
Digital Output Board Not Detected (System Events->iCOM DO Board [2]) BV-338 5417_1_2 Active on Event
Digital Output Board Not Detected (System Events->iCOM DO Board [3]) BV-349 5417_1_3 Active on Event
Air Economizer Reduced Airflow (System Events) BV-517 5601_1 Active on Event
EEV Unspecified General Event (EEVs) BV-540 5625_1 Active on Event
Static Pressure Sensor Issue (PCW-PDX) BV-563 5629_1 Active on Event
Static Pressure Sensor Out of Range (PCW-PDX) BV-566 5910_1 Active on Event
Pump Unspecified General Event (EconoPhase) BV-623 5636_1 Active on Event
External Condenser TVSS Issue (Condensers) BV-1060 6105_1 Active on Event
External Condenser VFD Issue (Condensers) BV-1061 6106_1 Active on Event

31
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Object
Data Description Object Id Notes
Name
Compressor 1B Thermal Overload (PCW-PDX) BV-1146 6092_1 Active on Event
Compressor 2B Thermal Overload (PCW-PDX) BV-1147 6093_1 Active on Event
Compressor 1B Hours Exceeded (PCW-PDX) BV-1148 6094_1 Active on Event
Compressor 2B Hours Exceeded (PCW-PDX) BV-1149 6095_1 Active on Event
Team Static Pressure Sensor Failure (PCW-PDX) BV-1150 6303_1 Active on Event
Heating Lockout (PCW-PDX) BV-1151 6304_1 Active on Event
Free Cooling Stopped - High Room Temp (PCW-PDX) BV-1152 6305_1 Active on Event
Cold Aisle Temperature/Humidity Team Sensor Failure (PCW-PDX->Cold
BV-1163 6306_1_1 Active on Event
Aisle)
Cold Aisle Air Sensor Failure (PCW-PDX->Cold Aisle->Cold Aisle Sensor [1]) BV-1174 6309_1_1_1 Active on Event
Cold Aisle Air Sensor Failure (PCW-PDX->Cold Aisle->Cold Aisle Sensor [2]) BV-1185 6309_1_1_2 Active on Event
Cold Aisle Air Sensor Failure (PCW-PDX->Cold Aisle->Cold Aisle Sensor [3]) BV-1196 6309_1_1_3 Active on Event
Chilled Water Inlet Temperature Control Active (Chilled Water) BV-1207 6310_1 Active on Event
Standby Unit Activated Due to Chiller Failure (Chilled Water) BV-1208 6518_1 Active on Event
Chilled Water Inlet Temperature Sensor Failure (Chilled Water->Chilled
BV-1218 6313_1_1 Active on Event
Water Circuit [1])
Chilled Water Outlet Temperature Sensor Failure (Chilled Water->Chilled
BV-1219 6314_1_1 Active on Event
Water Circuit [1])
Chilled Water Flow Meter Sensor Failure (Chilled Water->Chilled Water
BV-1220 6315_1_1 Active on Event
Circuit [1])
Supply Chilled Water Loss of Flow (Chilled Water->Chilled Water Circuit [1]) BV-1221 4980_1_1 Active on Event
Chilled Water Inlet Temperature Sensor Failure (Chilled Water->Chilled
BV-1231 6313_1_2 Active on Event
Water Circuit [2])
Chilled Water Outlet Temperature Sensor Failure (Chilled Water->Chilled
BV-1232 6314_1_2 Active on Event
Water Circuit [2])
Chilled Water Flow Meter Sensor Failure (Chilled Water->Chilled Water
BV-1233 6315_1_2 Active on Event
Circuit [2])
Supply Chilled Water Loss of Flow (Chilled Water->Chilled Water Circuit [2]) BV-1234 4980_1_2 Active on Event
Virtual System Active (System Events) BV-18000 5642_1 Active on Event
Phase Sequence (System Events) BV-18001 5643_1 Active on Event

32
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

BACnet Multi-state Values


Data Description Object Id Object Name Notes
1 = UPD
2 = AIR
Server Class (Protocol) MSV-1 4553_1
3 = PMP
4 = PDU
1 = Supply
Air Temperature Control Sensor (Air Temperature) MSV-12 5012_1 2 = Remote
3 = Return
1 = Disabled
2 = Limit
Supply Air Temperature Sensor Control (Air->Supply Air) MSV-23 5332_1_1
3 = Control
4 = Cooling Only
1 = Relative
2 = Compensated
Humidity Control Type (Humidity) MSV-35 5603_1
3= Predicted
4= Dew Point
1 = Off
Compressor State (Compressors->Compressor [1]) MSV-45 5264_1_1
2 = On
Compressor Capacity Control State 1 = Off
MSV-46 5265_1_1
(Compressors->Compressor [1]) 2 = On
1 = Off
Compressor State (Compressors->Compressor [2]) MSV-57 5264_1_2
2 = On
Compressor Capacity Control State 1 = Off
MSV-58 5265_1_2
(Compressors->Compressor [2]) 2 = On
1 = Off
Free Cooling Status (Free Cooling) MSV-69 5302_1 2 = Start
3 = FC On
1 = Disabled
Free Cooling Internal Control Mode (Free Cooling) MSV-70 5357_1 2 = Contacts
3 = Value
Minimum Chilled Water Temp Set Point Enable 1 = Off
MSV-71 5359_1
(Free Cooling) 2 = On
1 = Auto
2 = Manual
Fan Control Mode (Fan) MSV-82 5373_1
3 = Economy
4 = Delta
1 = Normal
Operation
3 = Normal with
Warning
System Status (System Info) MSV-93 4123_1
4 = Normal with
Alarm
5 = Abnormal
Operation
0 = Off
Unit Operating State (System Info) MSV-94 4706_1 1 = On
2 = Standby
1 = Auto
Unit Control Mode (System Info) MSV-95 4707_1
2 = Manual
1 = Reason
Unknown
2 = Network Display
Unit Operating State Reason (System Info) MSV-96 5074_1 3 = Alarm
4 = Schedule
5 = Remote System
6 = External Input

33
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name Notes
7 = Local Display
1 = Off
Fan State (System Operations) MSV-107 5381_1
2 = On
1 = Off
Cooling State (System Operations) MSV-108 5382_1
2 = On
1 = Off
Free Cooling State (System Operations) MSV-109 5383_1
2 = On
1 = Off
Hot Water / Hot Gas State (System Operations) MSV-111 5385_1
2 = On
1 = Off
Electric Reheat State (System Operations) MSV-112 5386_1
2 = On
1 = Off
Dehumidifier State (System Operations) MSV-113 5387_1
2 = On
1 = Off
Humidifier State (System Operations) MSV-114 5388_1
2 = On
1 = Off
System On/Off Control (System Operations) MSV-115 5143_1
2 = On
Automatic Transfer Switch - Active Power Supply (System
MSV-116 6524_1 0=PS1, 1=PS2
Operations, index [1])
Automatic Transfer Switch - Power Supply 1 Status (System
MSV-117 6525_1 0=OK, 1=NOK
Operations, index [1])
Automatic Transfer Switch - Power Supply 2 Status (System
MSV-118 6526_1 0=OK, 1=NOK
Operations, index [1])
Customer Input 1 - Event Control 1 = Disabled
MSV-126 4718_1
(System Event Configuration) 2 = Enabled
1 = Message
Customer Input 1 - Event Type (System Event Configuration) MSV-127 4719_1 2 = Warning
3 = Alarm
Customer Input 2 - Event Control 1 = Disabled
MSV-128 5098_1
(System Event Configuration) 2 = Enabled
1 = Message
Customer Input 2 - Event Type (System Event Configuration) MSV-129 5099_1 2 = Warning
3 = Alarm
Customer Input 3 - Event Control 1 = Disabled
MSV-130 5100_1
(System Event Configuration) 2 = Enabled
1 = Message
Customer Input 3 - Event Type (System Event Configuration) MSV-131 5101_1 2 = Warning
3 = Alarm
Customer Input 4 - Event Control 1 = Disabled
MSV-132 5102_1
(System Event Configuration) 2 = Enabled
1 = Message
Customer Input 4 - Event Type (System Event Configuration) MSV-133 5103_1 2 = Warning
3 = Alarm
Ext Free Cooling Lockout - Event Control 1 = Disabled
MSV-134 5389_1
(System Event Configuration) 2 = Enabled
1 = Message
Ext Free Cooling Lockout - Event Type
MSV-135 5390_1 2 = Warning
(System Event Configuration)
3 = Alarm
Ext Condenser Pump High Water - Event Control 1 = Disabled
MSV-136 5122_1
(System Event Configuration) 2 = Enabled
1 = Message
Ext Condenser Pump High Water - Event Type
MSV-137 5123_1 2 = Warning
(System Event Configuration)
3 = Alarm
Ext Humidifier Lockout - Event Control 1 = Disabled
MSV-142 5086_1
(System Event Configuration) 2 = Enabled
Ext Humidifier Lockout - Event Type 1 = Message
MSV-143 5087_1
(System Event Configuration) 2 = Warning

34
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name Notes
3 = Alarm
Ext Loss of Flow - Event Control 1 = Disabled
MSV-144 5082_1
(System Event Configuration) 2 = Enabled
1 = Message
Ext Loss of Flow - Event Type (System Event Configuration) MSV-145 5083_1 2 = Warning
3 = Alarm
Ext Over Temperature - Event Control 1 = Disabled
MSV-146 5090_1
(System Event Configuration) 2 = Enabled
1 = Message
Ext Over Temperature - Event Type
MSV-147 5091_1 2 = Warning
(System Event Configuration)
3 = Alarm
Ext Reheat Lockout - Event Control 1 = Disabled
MSV-148 5084_1
(System Event Configuration) 2 = Enabled
1 = Message
Ext Reheat Lockout - Event Type
MSV-149 5085_1 2 = Warning
(System Event Configuration)
3 = Alarm
High Power Shutdown - Event Control 1 = Disabled
MSV-150 5141_1
(System Event Configuration) 2 = Enabled
1 = Message
High Power Shutdown - Event Type
MSV-151 5142_1 2 = Warning
(System Event Configuration)
3 = Alarm
Humidifier Issue - Event Control 1 = Disabled
MSV-152 5131_1
(System Event Configuration) 2 = Enabled
1 = Message
Humidifier Issue - Event Type
MSV-153 5132_1 2 = Warning
(System Event Configuration)
3 = Alarm
Master Unit Communication Lost - Event Control 1 = Disabled
MSV-154 5133_1
(System Event Configuration) 2 = Enabled
1 = Message
Master Unit Communication Lost - Event Type
MSV-155 5134_1 2 = Warning
(System Event Configuration)
3 = Alarm
Shutdown - Loss Of Power - Event Control 1 = Disabled
MSV-158 4715_1
(System Event Configuration) 2 = Enabled
1 = Message
Shutdown - Loss Of Power - Event Type
MSV-159 4716_1 2 = Warning
(System Event Configuration)
3 = Alarm
Smoke Detected - Event Control 1 = Disabled
MSV-160 4721_1
(System Event Configuration) 2 = Enabled
1 = Message
Smoke Detected - Event Type (System Event Configuration) MSV-161 4722_1 2 = Warning
3 = Alarm
Water Under Floor - Event Control 1 = Disabled
MSV-162 4724_1
(System Event Configuration) 2 = Enabled
1 = Message
Water Under Floor - Event Type
MSV-163 4725_1 2 = Warning
(System Event Configuration)
3 = Alarm
Ext Compressor Lockout - Event Control 1 = Disabled
MSV-164 5088_1
(System Event Configuration) 2 = Enabled
1 = Message
Ext Compressor Lockout - Event Type
MSV-165 5089_1 2 = Warning
(System Event Configuration)
3 = Alarm
Clogged Air Filter - Event Control 1 = Disabled
MSV-166 5135_1
(System Event Configuration) 2 = Enabled
1 = Message
Clogged Air Filter - Event Type (System Event Configuration) MSV-167 5136_1 2 = Warning
3 = Alarm
Ext Loss of Air Blower - Event Control MSV-168 5393_1 1 = Disabled

35
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name Notes
(System Event Configuration) 2 = Enabled
1 = Message
Ext Loss of Air Blower - Event Type
MSV-169 5394_1 2 = Warning
(System Event Configuration)
3 = Alarm
Compressor High Head Pressure - Event Control 1 = Disabled
MSV-180 5316_1_1
(System Event Configuration->Compressor [1]) 2 = Enabled
1 = Message
Compressor High Head Pressure - Event Type
MSV-181 5317_1_1 2 = Warning
(System Event Configuration->Compressor [1])
3 = Alarm
Compressor Low Suction Pressure - Event Control 1 = Disabled
MSV-182 5318_1_1
(System Event Configuration->Compressor [1]) 2 = Enabled
1 = Message
Compressor Low Suction Pressure - Event Type
MSV-183 5319_1_1 2 = Warning
(System Event Configuration->Compressor [1])
3 = Alarm
Compressor Short Cycle - Event Control 1 = Disabled
MSV-186 5397_1_1
(System Event Configuration->Compressor [1]) 2 = Enabled
1 = Message
Compressor Short Cycle - Event Type
MSV-187 5398_1_1 2 = Warning
(System Event Configuration->Compressor [1])
3 = Alarm
Compressor Thermal Overload - Event Control 1 = Disabled
MSV-188 5320_1_1
(System Event Configuration->Compressor [1]) 2 = Enabled
1 = Message
Compressor Thermal Overload - Event Type
MSV-189 5321_1_1 2 = Warning
(System Event Configuration->Compressor [1])
3 = Alarm
Dig Scroll Comp Discharge Over Temp - Event Ctrl 1 = Disabled
MSV-190 5399_1_1
(System Event Configuration->Compressor [1]) 2 = Enabled
1 = Message
Dig Scroll Comp Discharge Over Temp - Event Type
MSV-191 5400_1_1 2 = Warning
(System Event Configuration->Compressor [1])
3 = Alarm
Compressor High Head Pressure - Event Control 1 = Disabled
MSV-202 5316_1_2
(System Event Configuration->Compressor [2]) 2 = Enabled
1 = Message
Compressor High Head Pressure - Event Type
MSV-203 5317_1_2 2 = Warning
(System Event Configuration->Compressor [2])
3 = Alarm
Compressor Low Suction Pressure - Event Control 1 = Disabled
MSV-204 5318_1_2
(System Event Configuration->Compressor [2]) 2 = Enabled
1 = Message
Compressor Low Suction Pressure - Event Type
MSV-205 5319_1_2 2 = Warning
(System Event Configuration->Compressor [2])
3 = Alarm
Compressor Short Cycle - Event Control 1 = Disabled
MSV-208 5397_1_2
(System Event Configuration->Compressor [2]) 2 = Enabled
1 = Message
Compressor Short Cycle - Event Type
MSV-209 5398_1_2 2 = Warning
(System Event Configuration->Compressor [2])
3 = Alarm
Compressor Thermal Overload - Event Control 1 = Disabled
MSV-210 5320_1_2
(System Event Configuration->Compressor [2]) 2 = Enabled
1 = Message
Compressor Thermal Overload - Event Type
MSV-211 5321_1_2 2 = Warning
(System Event Configuration->Compressor [2])
3 = Alarm
Dig Scroll Comp Discharge Over Temp - Event Ctrl 1 = Disabled
MSV-212 5399_1_2
(System Event Configuration->Compressor [2]) 2 = Enabled
1 = Message
Dig Scroll Comp Discharge Over Temp - Event Type
MSV-213 5400_1_2 2 = Warning
(System Event Configuration->Compressor [2])
3 = Alarm
Ext Air Sensor A Event Control 1 = Disabled
MSV-224 5401_1_1
(System Event Configuration->Air) 2 = Enabled
Return Air Sensor Event Control MSV-225 5402_1_1 1 = Disabled

36
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name Notes
(System Event Configuration->Air) 2 = Enabled
Ext Air Sensor A High Humidity - Event Control 1 = Disabled
MSV-226 5403_1_1
(System Event Configuration->Air) 2 = Enabled
1 = Message
Ext Air Sensor A High Humidity - Event Type
MSV-227 5404_1_1 2 = Warning
(System Event Configuration->Air)
3 = Alarm
High Return Humidity - Event Control 1 = Disabled
MSV-234 5137_1_1
(System Event Configuration->Air) 2 = Enabled
1 = Message
High Return Humidity - Event Type
MSV-235 5138_1_1 2 = Warning
(System Event Configuration->Air)
3 = Alarm
Low Return Humidity - Event Control 1 = Disabled
MSV-236 5139_1_1
(System Event Configuration->Air) 2 = Enabled
1 = Message
Low Return Humidity - Event Type
MSV-237 5140_1_1 2 = Warning
(System Event Configuration->Air)
3 = Alarm
Return Air Over Temp - Event Control 1 = Disabled
MSV-238 5024_1_1
(System Event Configuration->Air) 2 = Enabled
1 = Message
Return Air Over Temp - Event Type
MSV-239 5025_1_1 2 = Warning
(System Event Configuration->Air)
3 = Alarm
Return Air Under Temp - Event Control 1 = Disabled
MSV-240 5407_1_1
(System Event Configuration->Air) 2 = Enabled
1 = Message
Return Air Under Temp - Event Type
MSV-241 5408_1_1 2 = Warning
(System Event Configuration->Air)
3 = Alarm
Fan Hours Exceeded - Event Control 1 = Disabled
MSV-252 5409_1_1
(System Event Configuration->Fan) 2 = Enabled
1 = Message
Fan Hours Exceeded - Event Type
MSV-253 5410_1_1 2 = Warning
(System Event Configuration->Fan)
3 = Alarm
1 = Disabled
Fan Issue - Event Control (System Event Configuration->Fan) MSV-254 4730_1_1
2 = Enabled
Main Fan Overload - Event Control 1 = Disabled
MSV-256 5411_1_1
(System Event Configuration->Fan) 2 = Enabled
1 = Message
Main Fan Overload - Event Type
MSV-257 5412_1_1 2 = Warning
(System Event Configuration->Fan)
3 = Alarm
Condenser Issue - Event Control 1 = Disabled
MSV-268 5413_1_1
(System Event Configuration->Condenser [1]) 2 = Enabled
1 = Message
Condenser Issue - Event Type (System Event Configuration-
MSV-269 5414_1_1 2 = Warning
>Condenser [1])
3 = Alarm
Condenser Issue - Event Control (System Event 1 = Disabled
MSV-280 5413_1_2
Configuration->Condenser [2]) 2 = Enabled
1 = Message
Condenser Issue - Event Type (System Event Configuration-
MSV-281 5414_1_2 2 = Warning
>Condenser [2])
3 = Alarm
1 = Reset
System Event Acknowledge/Reset (System Events) MSV-292 4717_1
2 = Acknowledge
Cold Aisle Humidity Calculation Method (PCW-PDX->Cold 1 = Highest
MSV-438 6081_1_1
Aisle) 2 = Average
Cold Aisle Temperature Calculation Method (PCW-PDX->Cold 1 = Highest
MSV-439 6082_1_1
Aisle) 2 = Average
1 = No
Cold Aisle Control Enable (PCW-PDX->Cold Aisle) MSV-440 6083_1_1
2 = Yes
Cold Aisle Force Max Fan/Cooling - Ext Control (PCW-PDX- MSV-441 6084_1_1 1 = No

37
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description Object Id Object Name Notes
>Cold Aisle) 2 = Yes
1 = No
Chilled Water Valve Reset Enable (PCW-PDX) MSV-443 6091_1
2 = Yes
0 = No
Underfloor Static Pressure Control Enable (PCW-PDX) MSV-529 6300_1 1 = Yes
2= Visualiz. Only
1 = N.C. / Cls
Return Damper Status (PCW-PDX) MSV-531 6301_1
2 = N.O. /Opn
Chilled Water Flow Loss Status (Chilled Water->Chilled Water 1 = OK
MSV-542 6519_1_1
Circuit [1]) 2 = Act.
Chilled Water Flow Loss Status (Chilled Water->Chilled Water 1 = OK
MSV-553 6519_1_2
Circuit [2]) 2 = Act.

38
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

SNMP
SNMP Parameters
Data Description OID
lgpAgentIdentManufacturer 1.3.6.1.4.1.476.1.42.2.1.1.0
lgpAgentIdentModel 1.3.6.1.4.1.476.1.42.2.1.2.0
lgpAgentIdentFirmwareVersion 1.3.6.1.4.1.476.1.42.2.1.3.0
lgpAgentIdentSerialNumber 1.3.6.1.4.1.476.1.42.2.1.4.0
lgpAgentIdentPartNumber 1.3.6.1.4.1.476.1.42.2.1.5.0
lgpAgentReboot 1.3.6.1.4.1.476.1.42.2.5.1.0
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.1
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.2
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.3
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.4
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.5
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.6
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.7
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.8
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.9
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.10
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.11
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.12
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.13
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.14
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.15
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.16
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.17
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.18
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.19
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.21
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.23
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.24
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.29
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.30
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.35
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.36
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.37
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.38
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.39
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.40
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.41
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.42
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.43

39
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.44
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.45
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.46
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.47
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.48
lgpConditionControlDescr 1.3.6.1.4.1.476.1.42.3.2.4.20.1.2.49
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.1
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.2
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.3
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.4
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.5
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.6
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.7
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.8
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.9
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.10
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.11
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.12
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.13
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.14
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.15
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.16
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.17
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.18
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.19
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.21
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.23
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.24
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.29
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.30
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.35
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.36
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.37
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.38
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.39
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.40
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.41
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.42
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.43
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.44
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.45
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.46
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.47

40
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.48
lgpConditionControlEnableStatus 1.3.6.1.4.1.476.1.42.3.2.4.20.1.3.49
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.1
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.2
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.3
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.4
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.5
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.6
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.7
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.8
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.9
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.10
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.11
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.12
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.13
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.14
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.15
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.16
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.17
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.18
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.19
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.21
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.23
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.24
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.29
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.30
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.37
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.38
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.39
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.40
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.41
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.42
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.43
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.44
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.45
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.47
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.48
lgpConditionControlType 1.3.6.1.4.1.476.1.42.3.2.4.20.1.4.49
lgpEnvTemperatureDescrDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2.1
lgpEnvTemperatureDescrDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2.2
lgpEnvTemperatureDescrDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2.3
lgpEnvTemperatureDescrDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2.7
lgpEnvTemperatureDescrDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2.8

41
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpEnvTemperatureDescrDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2.10
lgpEnvTemperatureMeasurementDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.3.2
lgpEnvTemperatureMeasurementDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.3.3
lgpEnvTemperatureMeasurementDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.3.7
lgpEnvTemperatureMeasurementDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.3.8
lgpEnvTemperatureMeasurementDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.3.10
lgpEnvTemperatureDailyHighDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.7.1
lgpEnvTemperatureDailyLowDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.8.1
lgpEnvTempDailyHighTimeHourDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.9.1
lgpEnvTempDailyHighTimeMinuteDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.10.1
lgpEnvTempDailyHighTimeSecondDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.11.1
lgpEnvTempDailyLowTimeHourDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.12.1
lgpEnvTempDailyLowTimeMinuteDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.13.1
lgpEnvTempDailyLowTimeSecondDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.14.1
lgpEnvTemperatureMeasurementTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50.2
lgpEnvTemperatureMeasurementTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50.3
lgpEnvTemperatureMeasurementTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50.7
lgpEnvTemperatureMeasurementTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50.8
lgpEnvTemperatureMeasurementTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.50.10
lgpEnvTemperatureHighThresholdTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.51.3
lgpEnvTemperatureLowThresholdTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.52.3
lgpEnvTemperatureSetPointTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.53.1
lgpEnvTemperatureSetPointTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.53.2
lgpEnvTemperatureSetPointTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.53.3
lgpEnvTemperatureDeadBandTenthsDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.60.1
lgpEnvTemperatureDescrDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.2.1
lgpEnvTemperatureDescrDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.2.2
lgpEnvTemperatureDescrDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.2.3
lgpEnvTemperatureDescrDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.2.7
lgpEnvTemperatureDescrDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.2.8
lgpEnvTemperatureDescrDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.2.10
lgpEnvTemperatureMeasurementDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3.2
lgpEnvTemperatureMeasurementDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3.3
lgpEnvTemperatureMeasurementDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3.7
lgpEnvTemperatureMeasurementDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3.8
lgpEnvTemperatureMeasurementDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3.10
lgpEnvTemperatureDailyHighDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.7.1
lgpEnvTemperatureDailyLowDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.8.1
lgpEnvTempDailyHighTimeHourDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.9.1
lgpEnvTempDailyHighTimeMinuteDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.10.1
lgpEnvTempDailyHighTimeSecondDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.11.1
lgpEnvTempDailyLowTimeHourDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.12.1
lgpEnvTempDailyLowTimeMinuteDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.13.1

42
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpEnvTempDailyLowTimeSecondDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.14.1
lgpEnvTemperatureMeasurementTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.50.2
lgpEnvTemperatureMeasurementTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.50.3
lgpEnvTemperatureMeasurementTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.50.7
lgpEnvTemperatureMeasurementTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.50.8
lgpEnvTemperatureMeasurementTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.50.10
lgpEnvTemperatureHighThresholdTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.51.3
lgpEnvTemperatureLowThresholdTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.52.3
lgpEnvTemperatureSetPointTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.53.1
lgpEnvTemperatureSetPointTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.53.2
lgpEnvTemperatureSetPointTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.53.3
lgpEnvTemperatureDeadBandTenthsDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.60.1
lgpEnvTemperatureSettingDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.1.0
lgpEnvTemperatureToleranceDegF 1.3.6.1.4.1.476.1.42.3.4.1.2.2.0
lgpEnvTemperatureSettingDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.1.0
lgpEnvTemperatureToleranceDegC 1.3.6.1.4.1.476.1.42.3.4.1.3.2.0
lgpEnvHumidityDescrRel 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.2.1
lgpEnvHumidityDescrRel 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.2.5
lgpEnvHumidityMeasurementRel 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.3.1
lgpEnvHumidityMeasurementRel 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.3.5
lgpEnvHumiditySetPoint 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.6.1
lgpEnvHumiditySetPoint 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.6.5
lgpEnvHumidityDailyHigh 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.7.1
lgpEnvHumidityDailyLow 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.8.1
lgpEnvHumidityDailyHighTimeHour 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.9.1
lgpEnvHumidityDailyHighTimeMinute 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.10.1
lgpEnvHumidityDailyHighTimeSecond 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.11.1
lgpEnvHumidityDailyLowTimeHour 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.12.1
lgpEnvHumidityDailyLowTimeMinute 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.13.1
lgpEnvHumidityDailyLowTimeSecond 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.14.1
lgpEnvHumidityDeadBand 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.15.1
lgpEnvHumidifyPropBand 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.16.1
lgpEnvHumidityMeasurementRelTenths 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.50.1
lgpEnvHumidityMeasurementRelTenths 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.50.5
lgpEnvHumidityHighThresholdRelTenths 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.51.1
lgpEnvHumidityHighThresholdRelTenths 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.51.5
lgpEnvHumidityLowThresholdRelTenths 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.52.1
lgpEnvHumidityLowThresholdRelTenths 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.52.5
lgpEnvStateSystem 1.3.6.1.4.1.476.1.42.3.4.3.1.0
lgpEnvStateCooling 1.3.6.1.4.1.476.1.42.3.4.3.2.0
lgpEnvStateHumidifying 1.3.6.1.4.1.476.1.42.3.4.3.4.0
lgpEnvStateDehumidifying 1.3.6.1.4.1.476.1.42.3.4.3.5.0
lgpEnvStateFan 1.3.6.1.4.1.476.1.42.3.4.3.7.0

43
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpEnvStateHeatingCapacity 1.3.6.1.4.1.476.1.42.3.4.3.10.0
lgpEnvStateOperatingReason 1.3.6.1.4.1.476.1.42.3.4.3.14.0
lgpEnvStateOperatingMode 1.3.6.1.4.1.476.1.42.3.4.3.15.0
lgpEnvStateFanCapacity 1.3.6.1.4.1.476.1.42.3.4.3.16.0
lgpEnvStateFreeCoolingCapacity 1.3.6.1.4.1.476.1.42.3.4.3.17.0
lgpEnvStateDehumidifyingCapacity 1.3.6.1.4.1.476.1.42.3.4.3.18.0
lgpEnvStateHumidifyingCapacity 1.3.6.1.4.1.476.1.42.3.4.3.19.0
lgpEnvStateFreeCooling 1.3.6.1.4.1.476.1.42.3.4.3.20.0
lgpEnvStateElectricHeater 1.3.6.1.4.1.476.1.42.3.4.3.21.0
lgpEnvStateHotWater 1.3.6.1.4.1.476.1.42.3.4.3.22.0
lgpEnvConfigRestartDelay 1.3.6.1.4.1.476.1.42.3.4.4.4.0
lgpEnvConfigTemperatureIntegTime 1.3.6.1.4.1.476.1.42.3.4.4.15.0
lgpEnvConfigHumidityIntegTime 1.3.6.1.4.1.476.1.42.3.4.4.18.0
lgpEnvConfigFreecoolingDeltaDegF 1.3.6.1.4.1.476.1.42.3.4.4.19.0
lgpEnvConfigFreecoolingDeltaDegC 1.3.6.1.4.1.476.1.42.3.4.4.20.0
lgpEnvConfigDeltaGlycolType 1.3.6.1.4.1.476.1.42.3.4.4.26.0
lgpEnvConfigHumidityControl 1.3.6.1.4.1.476.1.42.3.4.4.29.0
lgpEnvConfigTempControlAlgorithm 1.3.6.1.4.1.476.1.42.3.4.4.33.0
lgpEnvConfigBmsResetTimer 1.3.6.1.4.1.476.1.42.3.4.4.36.0
lgpEnvStatisticsComp1RunHr 1.3.6.1.4.1.476.1.42.3.4.6.1.0
lgpEnvStatisticsComp2RunHr 1.3.6.1.4.1.476.1.42.3.4.6.2.0
lgpEnvStatisticsFanRunHr 1.3.6.1.4.1.476.1.42.3.4.6.3.0
lgpEnvStatisticsReheat1RunHr 1.3.6.1.4.1.476.1.42.3.4.6.7.0
lgpEnvStatisticsReheat2RunHr 1.3.6.1.4.1.476.1.42.3.4.6.8.0
lgpEnvStatisticsReheat3RunHr 1.3.6.1.4.1.476.1.42.3.4.6.9.0
lgpEnvStatisticsHumidifyModeHrs 1.3.6.1.4.1.476.1.42.3.4.6.12.0
lgpEnvStatisticsDehumidifyModeHrs 1.3.6.1.4.1.476.1.42.3.4.6.13.0
lgpEnvStatisticsHotGasRunHr 1.3.6.1.4.1.476.1.42.3.4.6.14.0
lgpEnvStatisticsHotWaterRunHr 1.3.6.1.4.1.476.1.42.3.4.6.15.0
lgpEnvStatisticsFreeCoolRunHr 1.3.6.1.4.1.476.1.42.3.4.6.16.0
lgpSysState 1.3.6.1.4.1.476.1.42.3.7.2.2.0
lgpSysControlOperationOnOff 1.3.6.1.4.1.476.1.42.3.7.4.2.0
lgpSysMaintenanceCapacity 1.3.6.1.4.1.476.1.42.3.7.6.1.0
lgpSysMaintenanceYear 1.3.6.1.4.1.476.1.42.3.7.6.2.0
lgpSysMaintenanceMonth 1.3.6.1.4.1.476.1.42.3.7.6.3.0
System Input RMS A-N 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4096
System Input RMS A-B 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4097
System Input RMS B-N 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4098
System Input RMS B-C 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4099
System Input RMS C-N 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4100
System Input RMS C-A 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4101
System Input RMS Current Phase A 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4113
System Input RMS Current Phase B 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4114

44
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
System Input RMS Current Phase C 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4115
System Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4123
System Model Number 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4240
Return Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4291
System Date and Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4293
System Name 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4329
Server Class 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4553
Ext Air Sensor A Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4594
Ext Air Sensor A Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4595
Ext Air Sensor B Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4597
Ext Air Sensor B Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4598
Ext Air Sensor A Over Temp - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4602
Ext Air Sensor A Over Temp - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4603
Ext Air Sensor A Under Temp - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4609
Ext Air Sensor A Under Temp - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4610
Unit Operating State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4706
Unit Control Mode 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4707
Auto Restart Delay 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4710
Shutdown - Loss Of Power - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4715
Shutdown - Loss Of Power - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4716
Customer Input 1 - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4718
Customer Input 1 - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4719
Smoke Detected - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4721
Smoke Detected - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4722
Water Under Floor - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4724
Water Under Floor - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4725
Fan Issue - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4730
Calculated Next Maintenance Month 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4868
Calculated Next Maintenance Year 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4869
Maintenance Ramp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.4870
Supply Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5002
Return Dew Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5004
Air Temperature Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5008
Air Temperature Dead Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5011
High Return Air Temperature Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5022
Return Air Over Temp - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5024
Return Air Over Temp - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5025
Return Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5028
Humidity Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5029
Humidity Dead Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5032
High Return Humidity Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5033
Low Return Humidity Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5035
Fan Speed Maximum Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5050

45
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Unit Operating State Reason 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5074
BMS Timeout Period 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5075
Fan Speed 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5077
Compressor/CW Valve Utilization 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5078
Dehumidifier Utilization 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5079
Reheat Utilization 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5080
Humidifier Utilization 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5081
Ext Loss of Flow - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5082
Ext Loss of Flow - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5083
Ext Reheat Lockout - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5084
Ext Reheat Lockout - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5085
Ext Humidifier Lockout - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5086
Ext Humidifier Lockout - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5087
Ext Compressor Lockout - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5088
Ext Compressor Lockout - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5089
Ext Over Temperature - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5090
Ext Over Temperature - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5091
Customer Input 2 - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5098
Customer Input 2 - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5099
Customer Input 3 - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5100
Customer Input 3 - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5101
Customer Input 4 - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5102
Customer Input 4 - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5103
Ext Condenser Pump High Water - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5122
Ext Condenser Pump High Water - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5123
Humidifier Issue - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5131
Humidifier Issue - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5132
Master Unit Communication Lost - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5133
Master Unit Communication Lost - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5134
Clogged Air Filter - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5135
Clogged Air Filter - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5136
High Return Humidity - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5137
High Return Humidity - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5138
Low Return Humidity - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5139
Low Return Humidity - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5140
High Power Shutdown - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5141
High Power Shutdown - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5142
System On/Off Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5143
Compressor State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5264.1
Compressor State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5264.2
Compressor Capacity Control State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5265.1
Compressor Capacity Control State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5265.2
Compressor Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5267.1

46
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Compressor Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5267.2
Compressor Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5268.1
Compressor Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5268.2
Free Cooling Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5302
Free Cooling Valve Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5304
Free Cooling Valve Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5305
Compressor High Head Pressure - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5316.1
Compressor High Head Pressure - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5316.2
Compressor High Head Pressure - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5317.1
Compressor High Head Pressure - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5317.2
Compressor Low Suction Pressure - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5318.1
Compressor Low Suction Pressure - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5318.2
Compressor Low Suction Pressure - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5319.1
Compressor Low Suction Pressure - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5319.2
Compressor Thermal Overload - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5320.1
Compressor Thermal Overload - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5320.2
Compressor Thermal Overload - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5321.1
Compressor Thermal Overload - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5321.2
Air Temperature Control Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5324
Air Temperature Proportional Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5325
Air Temperature Control Integration Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5326
Today's High Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5327
Today's High Air Temperature Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5328
Today's Low Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5329
Today's Low Air Temperature Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5330
Supply Air Temperature Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5331
Supply Air Temperature Sensor Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5332
Actual Return Air Temperature Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5333
Low Return Air Temperature Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5334
Ext Air Sensor C Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5336
Actual Return Humidity Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5339
Humidity Proportional Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5341
Humidity Control Integration Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5342
Today's High Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5343
Today's High Humidity Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5344
Today's Low Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5345
Today's Low Humidity Time 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5346
Ext Air Sensor C Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5347
Dig Scroll Comp Discharge Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5353.1
Dig Scroll Comp Discharge Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5353.2
Free Cooling Internal Temperature Delta 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5356
Free Cooling Internal Control Mode 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5357
Free Cooling Fluid Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5358

47
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Minimum Chilled Water Temp Set Point Enable 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5359
Minimum Chilled Water Temp Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5360
Hot Water / Hot Gas Valve Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5363
Hot Water / Hot Gas Valve Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5364
Electric Reheater Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5366.1
Electric Reheater Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5366.2
Electric Reheater Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5366.3
Electric Reheater Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5367.1
Electric Reheater Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5367.2
Electric Reheater Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5367.3
Humidifier Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5369
Humidifier Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5370
Dehumidifier Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5371
Dehumidifier Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5372
Fan Control Mode 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5373
Fan Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5374
Fan Hours Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5375
Analog Input Reading 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5378.1
Analog Input Reading 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5378.2
Analog Input Reading 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5378.3
Analog Input Reading 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5378.4
Free Cooling Valve Open Position 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5379
Hot Water / Hot Gas Valve Open Position 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5380
Fan State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5381
Cooling State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5382
Free Cooling State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5383
Maintenance Tracking State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5384
Hot Water / Hot Gas State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5385
Electric Reheat State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5386
Dehumidifier State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5387
Humidifier State 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5388
Ext Free Cooling Lockout - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5389
Ext Free Cooling Lockout - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5390
Ext Loss of Air Blower - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5393
Ext Loss of Air Blower - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5394
Compressor Short Cycle - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5397.1
Compressor Short Cycle - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5397.2
Compressor Short Cycle - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5398.1
Compressor Short Cycle - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5398.2
Dig Scroll Comp Discharge Over Temp - Event Ctrl 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5399.1
Dig Scroll Comp Discharge Over Temp - Event Ctrl 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5399.2
Dig Scroll Comp Discharge Over Temp - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5400.1
Dig Scroll Comp Discharge Over Temp - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5400.2

48
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Ext Air Sensor A Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5401
Return Air Sensor Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5402
Ext Air Sensor A High Humidity - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5403
Ext Air Sensor A High Humidity - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5404
Ext Air Sensor A Low Humidity - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5405
Ext Air Sensor A Low Humidity - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5406
Return Air Under Temp - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5407
Return Air Under Temp - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5408
Fan Hours Exceeded - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5409
Fan Hours Exceeded - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5410
Main Fan Overload - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5411
Main Fan Overload - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5412
Condenser Issue - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5413.1
Condenser Issue - Event Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5413.2
Condenser Issue - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5414.1
Condenser Issue - Event Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5414.2
Infrared Humidifier Flush Rate 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5445
Cooling Capacity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5491.1
Cooling Capacity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5491.2
Adjusted Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5606
Outside Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5574
Dew Point Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5575
Humidity Control Type 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5603
Chilled Water Valve Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5614.1
Chilled Water Valve Hours 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5614.2
Static Pressure Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5626
System Static Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5628
MAN-OFF-AUTO Switch 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5671
Condenser 1 Ambient Outside Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5672
Condenser 2 Ambient Outside Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5673
Power Meter Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5675
Actual Compressor 1 Suction Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5676
Actual Compressor 1 Suction Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5677
Main Valve 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5717
Fan Speed Delta Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5718
CW Valve Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5719
Fluid Flow Rate C1 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5899.1
Fluid Flow Rate C2 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5899.2
Energy Consumption 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5900
Instantaneous Power 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.5901
Cold Aisle Humidity Calculation Method 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6081
Cold Aisle Temperature Calculation Method 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6082
Cold Aisle Control Enable 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6083

49
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Cold Aisle Force Max Fan/Cooling - Ext Control 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6084
Actual Cold Aisle Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6085
Actual Cold Aisle Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6086
Cold Aisle Cascade Fan Speed Max Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6087
Cold Aisle Fan Speed Min Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6088
Cold Aisle Fan Speed Max Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6089
Chilled Water Valve Reset Enable 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6091
Humidification Fan Speed Min Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6096
Heating Fan Speed Min Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6097
Dehumidification Fan Speed Min Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6098
Back Draft Control Fan Speed 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6099
Super Saver Call For Cooling 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6234
Dew Point Proportional Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6258
Dew Point Dead Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6259
Underfloor Static Pressure Control Enable 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6300
Return Damper Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6301
Air Filter Differential Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6302
Cold Aisle Sensor Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6307.1
Cold Aisle Sensor Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6307.2
Cold Aisle Sensor Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6307.3
Cold Aisle Sensor Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6308.1
Cold Aisle Sensor Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6308.2
Cold Aisle Sensor Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6308.3
Chilled Water Inlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6311.1
Chilled Water Inlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6311.2
Chilled Water Outlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6312.1
Chilled Water Outlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6312.2
Compressor Discharge Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6517.1
Compressor Discharge Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6517.2
Chilled Water Flow Loss Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6519.1
Chilled Water Flow Loss Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6519.2
Customer Configurable Analog Output Value 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6520.1
Customer Configurable Analog Output Value 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6520.2
Customer Configurable Analog Output Value 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6520.3
Customer Configurable Analog Output Value 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6520.4
Automatic Transfer Switch - Active Power Supply 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6524
Automatic Transfer Switch - Power Supply 1 Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6525
Automatic Transfer Switch - Power Supply 2 Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6526
Dew Point Over Temp Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6575
Dew Point Under Temp Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.1.6576
Return Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.4291
Ext Air Sensor A Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.4594
Ext Air Sensor B Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.4597

50
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Supply Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5002
Return Dew Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5004
Air Temperature Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5008
Air Temperature Dead Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5011
High Return Air Temperature Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5022
Air Temperature Proportional Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5325
Today's High Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5327
Today's Low Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5329
Supply Air Temperature Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5331
Actual Return Air Temperature Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5333
Low Return Air Temperature Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5334
Ext Air Sensor C Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5336
Ext Air Sensor A Over Temp Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5337
Ext Air Sensor A Under Temp Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5338
Dig Scroll Comp Discharge Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5353.1
Dig Scroll Comp Discharge Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5353.2
Free Cooling Internal Temperature Delta 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5356
Free Cooling Fluid Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5358
Minimum Chilled Water Temp Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5360
Dew Point Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5575
Static Pressure Set Point 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5626
System Static Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.5628
Actual Cold Aisle Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6086
Dew Point Proportional Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6258
Dew Point Dead Band 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6258
Air Filter Differential Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6302
Cold Aisle Sensor Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6307.1
Cold Aisle Sensor Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6307.2
Cold Aisle Sensor Air Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6307.3
Chilled Water Inlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6311.1
Chilled Water Inlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6311.2
Chilled Water Outlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6312.1
Chilled Water Outlet Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6312.2
Dew Point Over Temp Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6575
Dew Point Under Temp Threshold 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.2.6576
Customer Input 1 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4270
Customer Input 2 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4271
Customer Input 3 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4272
Customer Input 4 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4273
Ext Dew Point Over Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4615
Supply Chilled Water Over Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4626
Shutdown - Loss Of Power 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4714
Smoke Detected 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4720

51
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Water Under Floor 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4723
Service Required 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4726
EC Fan Fault 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4729
Supply Chilled Water Loss of Flow 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4980.1
Supply Chilled Water Loss of Flow 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.4980.2
Supply Air Over Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5015
Supply Air Under Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5019
Return Air Over Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5023
Supply Air Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5026
High Return Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5034
Low Return Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5036
Humidifier Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5037
Dehumidifier Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5038
Humidifier Under Current 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5039
Humidifier Over Current 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5040
Humidifier Low Water 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5041
Humidifier Cylinder Worn 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5042
Humidifier Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5043
Ext Humidifier Lockout 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5044
Humidifier Control Board Not Detected 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5045
Loss of Air Flow 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5053
Fan Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5054
Ext Compressor Lockout 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5067
Reheater Over Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5068
Ext Reheat Lockout 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5070
Ext Over Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5104
Ext Loss of Flow 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5105
Ext Condenser Pump High Water 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5106
Ext Standby Glycol Pump On 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5107
External Fire Detected 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5108
Unit On 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5109
Unit Off 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5110
Unit Standby 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5111
Unit Partial Shutdown 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5112
Unit Shutdown 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5113
Water Leakage Detector Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5114
BMS Communications Timeout 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5115
Maintenance Due 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5116
Maintenance Completed 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5117
Clogged Air Filter 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5118
RAM Battery Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5119
Master Unit Communication Lost 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5120
High Power Shutdown 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5121

52
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Return Air Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5147
Compressor High Pressure Transducer Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5148.1
Compressor High Pressure Transducer Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5148.2
Compressor Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5269.1
Compressor Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5269.2
Compressor High Head Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5270.1
Compressor High Head Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5270.2
Compressor Low Suction Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5271.1
Compressor Low Suction Pressure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5271.2
Compressor Thermal Overload 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5272.1
Compressor Thermal Overload 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5272.2
Free Cooling Valve Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5306
Return Air Under Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5335
Ext Air Sensor A High Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5349
Ext Air Sensor A Low Humidity 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5351
Compressor Short Cycle 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5352.1
Compressor Short Cycle 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5352.2
Dig Scroll Comp Discharge Temp Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5354.1
Dig Scroll Comp Discharge Temp Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5354.2
Dig Scroll Comp Over Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5355.1
Dig Scroll Comp Over Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5355.2
Ext Free Cooling Lockout 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5361
Free Cooling Temp Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5362
Hot Water / Hot Gas Valve Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5365
Electric Reheater Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5368.1
Electric Reheater Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5368.2
Electric Reheater Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5368.3
Main Fan Overload 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5376
Condenser Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5377.1
Condenser Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5377.2
Ext Loss of Air Blower 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5415
Ext Standby Unit On 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5416
Digital Output Board Not Detected 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5417.1
Digital Output Board Not Detected 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5417.2
Digital Output Board Not Detected 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5417.3
Unit Code Missing 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5418
Unit Communication Lost 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5419
Compressor Capacity Reduced 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5513
Compressor Low Pressure Transducer Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5514.1
Compressor Low Pressure Transducer Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5514.2
Ambient Air Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5573
Ext Dew Point Under Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5577
Dew Point Over Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5578

53
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Dew Point Under Temperature 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5579
Air Economizer Reduced Airflow 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5601
EEV Unspecified General Event 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5625
Static Pressure Sensor Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5629
Pump Unspecified General Event 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5636
Virtual System Active 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5642
Phase Sequence 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5643
Ext Air Damper Position Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5907
Static Pressure Sensor Out of Range 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.5910
Compressor 1B Thermal Overload 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6092
Compressor 2B Thermal Overload 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6093
Compressor 1B Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6094
Compressor 2B Hours Exceeded 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6095
External Condenser TVSS Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6105
External Condenser VFD Issue 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6106
SEC Unspecified General Event 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6232
Team Static Pressure Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6303
Heating Lockout 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6304
Free Cooling Stopped - High Room Temp 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6305
Cold Aisle Temperature/Humidity Team Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6306
Cold Aisle Air Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6309.1
Cold Aisle Air Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6309.2
Cold Aisle Air Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6309.3
Chilled Water Inlet Temperature Control Active 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6310
Chilled Water Inlet Temperature Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6313.1
Chilled Water Inlet Temperature Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6313.2
Chilled Water Outlet Temperature Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6314.1
Chilled Water Outlet Temperature Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6314.2
Chilled Water Flow Meter Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6315.1
Chilled Water Flow Meter Sensor Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6315.2
Standby Unit Activated Due to Chiller Failure 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.2.100.6518
System Status 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.4123
System Model Number 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.4240
Server Class 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.4553
Sensor Order Identifier - Slot 01 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6109
Sensor Order Identifier - Slot 02 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6110
Sensor Order Identifier - Slot 03 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6111
Sensor Order Identifier - Slot 04 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6112
Sensor Order Identifier - Slot 05 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6113
Sensor Order Identifier - Slot 06 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6114
Sensor Order Identifier - Slot 07 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6115
Sensor Order Identifier - Slot 08 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6116
Sensor Order Identifier - Slot 09 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6117

54
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
Sensor Order Identifier - Slot 10 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.1.6118
Too Many Sensors 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.100.5423
Slots not available 1.3.6.1.4.1.476.1.42.3.9.20.1.20.1.3.20.100.6119

55
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit

SNMP Events
Data Description OID
lgpConditionLossOfAirflowAllBlowers 1.3.6.1.4.1.476.1.42.3.2.1.5.4
lgpConditionCompressor1HighHeadPressure 1.3.6.1.4.1.476.1.42.3.2.1.7.1
lgpConditionCompressor2HighHeadPressure 1.3.6.1.4.1.476.1.42.3.2.1.7.2
lgpConditionCompressor1Overload 1.3.6.1.4.1.476.1.42.3.2.1.8.1
lgpConditionCompressor2Overload 1.3.6.1.4.1.476.1.42.3.2.1.8.2
lgpConditionCompressor1ShortCycle 1.3.6.1.4.1.476.1.42.3.2.1.9.1
lgpConditionCompressor2ShortCycle 1.3.6.1.4.1.476.1.42.3.2.1.9.2
lgpConditionCompressor1LowSuctionPressure 1.3.6.1.4.1.476.1.42.3.2.1.10.1
lgpConditionCompressor2LowSuctionPressure 1.3.6.1.4.1.476.1.42.3.2.1.10.2
lgpConditionStandbyGlycoolPumpOn 1.3.6.1.4.1.476.1.42.3.2.1.13
lgpConditionWaterUnderFloor 1.3.6.1.4.1.476.1.42.3.2.1.14
lgpConditionHumidifierProblem 1.3.6.1.4.1.476.1.42.3.2.1.15
lgpConditionLowWaterInHumidifier 1.3.6.1.4.1.476.1.42.3.2.1.16
lgpConditionSmokeDetected 1.3.6.1.4.1.476.1.42.3.2.1.17
lgpConditionLostPower 1.3.6.1.4.1.476.1.42.3.2.1.19
lgpConditionStandbyUnitOn 1.3.6.1.4.1.476.1.42.3.2.1.22
lgpConditionServiceCooling 1.3.6.1.4.1.476.1.42.3.2.1.26
lgpConditionSystemControlBatteryLow 1.3.6.1.4.1.476.1.42.3.2.1.28
lgpConditionBlowerFanFailure 1.3.6.1.4.1.476.1.42.3.2.1.43.4
lgpConditionHumidifierOverCurrent 1.3.6.1.4.1.476.1.42.3.2.1.53.9
lgpConditionAirSensorAFailure 1.3.6.1.4.1.476.1.42.3.2.1.54.18
lgpConditionAirSupplyTempSensorFailure 1.3.6.1.4.1.476.1.42.3.2.1.54.25
lgpConditionAirReturnTempSensorFailure 1.3.6.1.4.1.476.1.42.3.2.1.54.26
lgpConditionExternalCommunicationFailure 1.3.6.1.4.1.476.1.42.3.2.1.56
lgpConditionChilledWaterOverTemperature 1.3.6.1.4.1.476.1.42.3.2.1.59.12
lgpConditionElectricHeatersOverTemperature 1.3.6.1.4.1.476.1.42.3.2.1.59.13
lgpConditionCheckAirFilter 1.3.6.1.4.1.476.1.42.3.2.1.78
lgpConditionHumidifierControlBdFailure 1.3.6.1.4.1.476.1.42.3.2.1.96.5.1
lgpConditionAirFilterClogged 1.3.6.1.4.1.476.1.42.3.2.1.132
lgpConditionHumidifierFailure 1.3.6.1.4.1.476.1.42.3.2.1.133
lgpConditionFreeCoolRunHrsExceeded 1.3.6.1.4.1.476.1.42.3.2.1.134.4
lgpConditionHotGasRunHrsExceeded 1.3.6.1.4.1.476.1.42.3.2.1.134.9
lgpConditionHumidifierRunHrsExceeded 1.3.6.1.4.1.476.1.42.3.2.1.134.10
lgpConditionDehumidiferRunHrsExceeded 1.3.6.1.4.1.476.1.42.3.2.1.134.11
lgpConditionFanRunHrsExceeded 1.3.6.1.4.1.476.1.42.3.2.1.134.12
lgpConditionUnitOn 1.3.6.1.4.1.476.1.42.3.2.1.136
lgpConditionUnitOff 1.3.6.1.4.1.476.1.42.3.2.1.137
lgpConditionSystemOnStanby 1.3.6.1.4.1.476.1.42.3.2.1.140
lgpConditionHighTemperatureExternalAirSensorA 1.3.6.1.4.1.476.1.42.3.2.1.142.6
lgpConditionHighTemperatureSupplyAir 1.3.6.1.4.1.476.1.42.3.2.1.142.10
lgpConditionHighTemperatureReturnAir 1.3.6.1.4.1.476.1.42.3.2.1.142.11
lgpConditionLowTemperatureExternalAirSensorA 1.3.6.1.4.1.476.1.42.3.2.1.143.3
lgpConditionLowTemperatureSupplyAir 1.3.6.1.4.1.476.1.42.3.2.1.143.7
lgpConditionHighHumidityReturnAir 1.3.6.1.4.1.476.1.42.3.2.1.144.2
lgpConditionLowHumidityReturnAir 1.3.6.1.4.1.476.1.42.3.2.1.145.2
lgpConditionPeerNetworkNoMaster 1.3.6.1.4.1.476.1.42.3.2.1.146
lgpConditionUnitShutdown 1.3.6.1.4.1.476.1.42.3.2.1.150
lgpConditionCondensatePumpHighWater 1.3.6.1.4.1.476.1.42.3.2.1.153
lgpConditionUnitCodeNotConfigured 1.3.6.1.4.1.476.1.42.3.2.1.162.1
lgpConditionHighExternalDewPoint 1.3.6.1.4.1.476.1.42.3.2.1.163.1

56
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpConditionCondenser1Failure 1.3.6.1.4.1.476.1.42.3.2.1.180.1
lgpConditionCondenser2Failure 1.3.6.1.4.1.476.1.42.3.2.1.180.2
lgpConditionHumidifierCyclinderWorn 1.3.6.1.4.1.476.1.42.3.2.1.181
lgpConditionHumidifierUnderCurrent 1.3.6.1.4.1.476.1.42.3.2.1.182.1
lgpConditionFreeCoolLockout 1.3.6.1.4.1.476.1.42.3.2.1.184
lgpConditionWaterLeakSensorFailure 1.3.6.1.4.1.476.1.42.3.2.1.185
lgpConditionInputContact01 1.3.6.1.4.1.476.1.42.3.2.1.218.1
lgpConditionInputContact02 1.3.6.1.4.1.476.1.42.3.2.1.218.2
lgpConditionInputContact03 1.3.6.1.4.1.476.1.42.3.2.1.218.3
lgpConditionInputContact04 1.3.6.1.4.1.476.1.42.3.2.1.218.4
lgpConditionMaintenanceDue 1.3.6.1.4.1.476.1.42.3.2.1.235.1
lgpConditionMaintenanceComplete 1.3.6.1.4.1.476.1.42.3.2.1.235.2
lgpConditionExternalFireDetect 1.3.6.1.4.1.476.1.42.3.2.1.236.1
lgpConditionExternalFlowLoss 1.3.6.1.4.1.476.1.42.3.2.1.236.2
lgpConditionExternalReheatLockout 1.3.6.1.4.1.476.1.42.3.2.1.236.3
lgpConditionExternalOverTemp 1.3.6.1.4.1.476.1.42.3.2.1.236.4
lgpConditionExternalCompLockout 1.3.6.1.4.1.476.1.42.3.2.1.236.5
lgpConditionExternalHumidifierLockout 1.3.6.1.4.1.476.1.42.3.2.1.236.6
lgpConditionComponentShutdownPartial 1.3.6.1.4.1.476.1.42.3.2.1.237.1
lgpConditionComponentShutdownHighPower 1.3.6.1.4.1.476.1.42.3.2.1.237.2
lgpCondId5148CompressorHighPressureTransducerIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5148
lgpCondId5148CompressorHighPressureTransducerIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5148
lgpCondId5269CompressorHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.5269
lgpCondId5269CompressorHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.5269
lgpCondId5335ReturnAirUnderTemperature 1.3.6.1.4.1.476.1.42.3.2.7.1.5335
lgpCondId5349ExtAirSensorAHighHumidity 1.3.6.1.4.1.476.1.42.3.2.7.1.5349
lgpCondId5351ExtAirSensorALowHumidity 1.3.6.1.4.1.476.1.42.3.2.7.1.5351
lgpCondId5354DigScrollCompDischargeTempSensorIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5354
lgpCondId5354DigScrollCompDischargeTempSensorIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5354
lgpCondId5355DigScrollCompOverTemp 1.3.6.1.4.1.476.1.42.3.2.7.1.5355
lgpCondId5355DigScrollCompOverTemp 1.3.6.1.4.1.476.1.42.3.2.7.1.5355
lgpCondId5362FreeCoolingTempSensorIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5362
lgpCondId5368ElectricReheaterHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.5368
lgpCondId5368ElectricReheaterHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.5368
lgpCondId5368ElectricReheaterHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.5368
lgpCondId5376MainFanOverload 1.3.6.1.4.1.476.1.42.3.2.7.1.5376
lgpCondId5415ExtLossofAirBlower 1.3.6.1.4.1.476.1.42.3.2.7.1.5415
lgpCondId5417DigitalOutputBoardNotDetected 1.3.6.1.4.1.476.1.42.3.2.7.1.5417
lgpCondId5417DigitalOutputBoardNotDetected 1.3.6.1.4.1.476.1.42.3.2.7.1.5417
lgpCondId5417DigitalOutputBoardNotDetected 1.3.6.1.4.1.476.1.42.3.2.7.1.5417
lgpCondId5419UnitCommunicationLost 1.3.6.1.4.1.476.1.42.3.2.7.1.5419
lgpCondId5513CompressorCapacityReduced 1.3.6.1.4.1.476.1.42.3.2.7.1.5513
lgpCondId5514CompressorLowPressureTransducerIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5514
lgpCondId5514CompressorLowPressureTransducerIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5514
lgpCondId5573AmbientAirSensorIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5573
lgpCondId5577ExtDewPointUnderTemperature 1.3.6.1.4.1.476.1.42.3.2.7.1.5577
lgpCondId5578DewPointOverTemperature 1.3.6.1.4.1.476.1.42.3.2.7.1.5578
lgpCondId5579DewPointUnderTemperature 1.3.6.1.4.1.476.1.42.3.2.7.1.5579
lgpCondId5601AirEconomizerReducedAirflow 1.3.6.1.4.1.476.1.42.3.2.7.1.5601
lgpCondId5625EEVUnspecifiedGeneralEvent 1.3.6.1.4.1.476.1.42.3.2.7.1.5625
lgpCondId5629StaticPressureSensorIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5629
lgpCondId5907ExtAirDamperPositionIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.5907
lgpCondId5910StaticPressureSensorOutofRange 1.3.6.1.4.1.476.1.42.3.2.7.1.5910

57
Liebert IS-Unity-DP Card (MODBUS, BACnet, SNMP) data points for PCW/PDX unit
Data Description OID
lgpCondId6092Compressor1BThermalOverload 1.3.6.1.4.1.476.1.42.3.2.7.1.6092
lgpCondId6093Compressor2BThermalOverload 1.3.6.1.4.1.476.1.42.3.2.7.1.6093
lgpCondId6094Compressor1BHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.6094
lgpCondId6095Compressor2BHoursExceeded 1.3.6.1.4.1.476.1.42.3.2.7.1.6095
lgpCondId6105ExternalCondenserTVSSIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.6105
lgpCondId6106ExternalCondenserVFDIssue 1.3.6.1.4.1.476.1.42.3.2.7.1.6106
lgpCondId6303TeamStaticPressureSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6303
lgpCondId6304HeatingLockout 1.3.6.1.4.1.476.1.42.3.2.7.1.6304
lgpCondId6305FreeCoolingStoppedHighRoomTemp 1.3.6.1.4.1.476.1.42.3.2.7.1.6305
lgpCondId6306ColdAisleTemperatureHumidityTeamSensorFai
lure 1.3.6.1.4.1.476.1.42.3.2.7.1.6306
lgpCondId6309ColdAisleAirSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6309
lgpCondId6309ColdAisleAirSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6309
lgpCondId6309ColdAisleAirSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6309
lgpCondId6310ChilledWaterInletTemperatureControlActive 1.3.6.1.4.1.476.1.42.3.2.7.1.6310
lgpCondId6313ChilledWaterInletTemperatureSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6313
lgpCondId6313ChilledWaterInletTemperatureSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6313
lgpCondId6314ChilledWaterOutletTemperatureSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6314
lgpCondId6314ChilledWaterOutletTemperatureSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6314
lgpCondId6315ChilledWaterFlowMeterSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6315
lgpCondId6315ChilledWaterFlowMeterSensorFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6315
lgpCondId6518StandbyUnitActivatedDuetoChillerFailure 1.3.6.1.4.1.476.1.42.3.2.7.1.6518
lgpCondId5423TooManySensors 1.3.6.1.4.1.476.1.42.3.2.7.1.5423
lgpCondId6119Slotsnotavailable 1.3.6.1.4.1.476.1.42.3.2.7.1.6119

FDM 10047

58