Round 1.
4 NFPA 704 Diamond signifies the four types of hazards, Which are they?
Ans Identification of hazards of material. Viz Health, Flammable, Reactivity &
Special information(hazards)
5 Who is Chairman of District Crisis Group and Mutal Aid Scheme - Jamnagar
District?
Ans Collector & District Magistrate
6 Which is the Product involved in the Explosion and Fire at Algeria Refienry?
Ans LNG
Spot Quiz Competition - Direct Round
Round 2. - Expand the term
3 Identify this part of Fire Delivery Hose Delivery Hose Male Coupling
4 Identify this part of CO2 Fire Extinguisher CO2 Extinguisher Discharge Horn
Identify this part of 75 kg DCP Fire 75 kg DCP
5 Discharge hose
Extinguisher Extinguisher
6 Identify this part of Fire Water Monitor Water Monitor Locking Lever
SN F & G System Visuals Answer
Ans : 1-QBD release, 2-DV control panel manual air release, 3-SOV thru C/R 4- DV
water priming valve water manual release, 5-Manual bypass
Question : What is the rate of application of water on tank surface to be protected from
exposure heat?
Ans : 10.2 lpm/m2
Question : What is the rate of application of water for hot pump deluge system?
Ans : 20.4 lpm/m2
Question : For LPG sphere what is the water application rate?
Ans : 10.2 lpm/m2 , leg cooling 5.1 lpm/m2, summer cooling - 2 lpm/m2, Cryogenic
roof top 3 lpm/m2
Question : In case of power failure, all DVs in the respective PIB will actuate at once, can
you explain the logic?
Ans : Solenoid valve logic is power fail to open
SCBA Set
Question : BA set refilling is to be carried out one it is empty/less pressure. If it is not used
for a long period, what is the maximum period the cylinder can be used without
refilling?
Ans : 6 months
Question : What is the function of demand regulator in SCBA set?
Ans : Supply the air as per wear's demand and maintain slightly +ve pressure(1.014bar
in face mask)
Question : If the 300 bar BA cylinder PG shows a 200 bar reading, what is the total effective
duration of set?
Ans : 15 min effective + 15 min escape = 30 minutes
Question : SCBA set working duration is based on average consuption rate of the wearer.
What is that average rate of consumption?
Ans : 40 lpm
Question : Why the escape set should not be used to carry out maintenance in the toxic area?
Ans : Escape set is only for escape and not for working in toxic area. Wearer cannot
establish the leftover time in case of escape set.
Question : Who is responsible for visual inspection and preservation of SCBA set at
respective plant area?
Ans : User / Plant
Ans : 5 nos.
Question : Minimum concentration of FM200 gas required to extinguish fire in PIB?
Ans : 7.20%
Question : Which chemical family of hydrocarbon FM200 belongs to?
Ans : Fluorinated Alkane / Halogenated HC (Hepta fluro propane)
Spot Quiz Competition - Rapid Fire Round
No FLASH Team
1 Escape Set Warning Whistle Operates At 40bar.
No INFERNO Team
1 Escape Set Maintains Positive Pressure Inside Facemask.
No FIRE Team
1 Dragger SCBA Set 300 Bar Cylinder Has Water Capacity 6 Liters.
No SPARK Team
1 SSM will be Chief Emergency Controller in absence of President
No BLAZE Team
1 Oxygen is 29% in SCBA cylinder
No FLAME Team
1 Presently fire water header in RRTF area is charged with sea water
1
Answer
0
0
Answer
1
1
Answer
0
0
1
1
0
0
1
0
Answer
0
0
Answer
1
0
Fire Quiz Contest - 2004
Clue # 1 Location - 100 miles off the east of scotland in north sea
Clue # 2 Major Cause - violation of permit to work system
Clue # 3 World's worst offshore petroleum accident
Maximum victims were due to smoke inhalation, No escape for
the trapped occupants, workers started jumping into the sea.
Clue # 4
There were miraculous escape for the personnel who swam for
hours together.
Tank level was 5 mtr, tank was under receipt and pumping was
Clue # 1 going out simultaneously
Tank roof travelled beyond normal height damaging the foam
Clue # 2 pourer system
3 nos. DGC actuated almost simultaneously from the adjucent
Clue # 3 pumpbay about 15 mtr distance
High level switch did not activate due to level switch float not
Clue # 4
designed for low density product being stored in the tank
Incident # 7 - Coker off gas leak from Compressor was line flange
It was a gas leak having 6-8% of H2S from the flange joint of
Clue # 1 compressor
Main cause of leak was graphite filled(soft) gasket blow out
Clue # 2 subsequently replaced with spiral wound gasket
In this operation about 27 SCBA cylinders were consumed
Clue # 3 during approx 4 hrs duraion
Toxic gas up to a distance of 30 mtr downwind and within
Clue # 4
compressor area.
Direct Question Databank for Fire Quiz Contest
SN Question
Q What is the theme for Fire day 2004?
A "Learn not to burn - Cultivate Fire Safety Awareness"
Q The vessel involved in an explosion which resulted in the showering of Golden Ingots
A MT FORT STRIKINE
Q NFPA 704 Diamond signifies
A Identification of hazards of material. Viz Health, Flammable, Reactivity & Special information
Q Chairman of District Crisis Group and Mutal Aid Scheme - Jamnagar District
A Collector & District Magistrate
Q Product involved in the Explosion and Fire at Algeria Refienry
A LNG
Q
A
Q
A
Q
A
Expand
CEC
Chief Emergency Coordinator
TREM - Card
Transport Emergency Card
BLEVE
Boiling Liquid Expanding Vapour Explosion
IDLH
Immediately Dangerous to Life and Health
MECC
Mobile Emergency Control Center
MCA
Maximum Creadible Accident
ODP
Ozone Depletion Potential
GWP
global Warming Potential
ALT
Atmospheric Life Time
AFFF
Aqueous Film Forming foam
Rapid Fire
Q
A 1
Q
A 1
Q
A 1
Q Floating roof tank containing Class A hydrocarbon is protected with semi-fixed foam po
A 1
Q
A 1
Q
A 1
Q QBD / Quartzoid buld detectors provided for tanks in RTF breaks at 200 deg C
A 0
Q Frequency of Dry testing of the Water deluge system is once in a year
A 0
Q
A 0
Q
Q 0
A
Q
A
Q
A
Q
A
For audience
Q expand SMS
A Smoke Management System
ial information
ed with semi-fixed foam pourer system