Вы находитесь на странице: 1из 2

DIAGNOSIS INFORMATION

This product is provided with the self-diagnosis function. In case of any abnormality, the LED at the top of the product will
indicate the errors.

Diagnosis method : Every time the main power is turned on, the SW is turned on and each sensor is checked for any
errors in 4 seconds. The POWER LED remains red during the check.

Diagnosis result indication : LED indication and failures are shown in the following table. LED can be reset “automatically” or
“by turning on/off of the main power” when the fault detection is finished.

Forced power-on : When the product can’t be turned on because of STBY power short or SW power short, press the 3
buttons of RGB, VIDEO and CARD at the top of the product simultaneously during 4 seconds of
the sensor check to turn on the product for fault detection. In this case, protection circuits except
for STBY power short and SW power short will operate.

LED Error Indication List

Preferen- LED Indication


Failure Symptom Purpose Reset
tial order POWER LAMP TEMP CARD

Fault Red/Green Red Main


1 STBY power short No power-on Orange *
Detection alternately flash 2 Power

Fault Red/Green Red Main


2 SW power short No power-on Orange *
Detection alternately flash Power

Fault Red/Green Red Main


3 Fan stops No power-on Red *
Detection alternately flash Power

Danger Red/Green
4 LBOX open No power-on – – * Auto
Prevention alternately

Dust Intake Red/Green


5 FBOX open No power-on – – * Auto
Prevention alternately

Unplugged thermistor Fault Red/Green Red


6 No power-on – * Auto
(Exhaustion LCD) Detection alternately flash

Unplugged thermistor Fault Red/Green Red


7 No power-on – * Auto
(Lamp) Detection alternately flash 2

Communication
Fault Red/Green
8 failure between the No power-on Orange Red * Auto
computers (serial) Detection alternately

Communication Fault Red/Green Red


9 failure between the Abnormal Operation Orange * Auto
Detection alternately flash 3
computers (parallel)

IIC bus failure Fault Red/Green Red


10 No power-on Green * Auto
(EEPROM) Detection alternately flash 2

IIC bus failure Inferior display of Fault Red/Green Red


11 Green * Auto
(Decoder) VIDEO input Detection alternately flash

Temperature sensor Temperature Red


12 No power-on Red – * Auto
(Lamp) rise flash 2

Temperature sensor Temperature Red


13 No power-on Red – * Auto
(Intake) rise flash

Temperature sensor Temperature Red


14 No power-on Red – * Auto
(LCD) rise flash 3

– : LED off Orange : Both Red and Green light


* : Need no confirmation Red flash N : The cycle that Red flashes N times and goes out for fixed time is repeated.

1
LED Error Indication List

Preferen- LED Indication


Failure Symptom Purpose Reset
tial order POWER LAMP TEMP CARD

Warning
indication by
Red
LED Red – * Manual
flash
Indication
during stand-by
Lamp’s life Only warning
(1500~2000h) indication by LED
Warning
15
indication by
Red/Green
LED Green – * Manual
alternately
Indication
during stand-by

Lamp’s life
No power-on Lamp’s life Red Red – * Manual
(2000h or over)

Lamp Green
16 Lamp doesn’t light No power-on for 1 minute Red – * Auto
protection flash

For 1 minute after Lamp Green


17 No power-off for 1 minute Green – * Auto
power-on protection flash

For 1 minute after Lamp Green


18 No power-on for 1 minute Red – * Auto
power-off protection flash

Inferior display of all Fault Green


19 IIC bus failure (HIC) * * * Auto
inputs detection flash

IIC bus failure Fault Green


20 No power-on * * * Auto
(EEPROM) detection flash 2

– : LED off Orange : Both Red and Green light


* : Need no confirmation Red flash N : The cycle that Red flashes N times and goes out for fixed time is repeated.

USING THE WARNING HISTORY RECOGNITION SOFTWARE (PCGCe Ver.4)


1. Start-up of the program When the [Clear History] button on the Main Dialogue is
1. Connect the projector to the personal computer with the pressed, the command of clearing the warning history is
attached RS-232C cable. sent to the projector and the indicated error is deleted.
2. Double-click the file [PCGC4e.exe] to start up the
program. 4. Refreshing of the warning data
After the start-up, the program opens the serial port and Press the [Refresh] button on the Main Dialogue to refresh
starts corresponding with the projector, in accordance the warning data such as when the warning data is not
with the specifications. correctly recognized.

2. Recognizing of the warning data 5. Occurrence of correspondence error


After the program is started up, the warning data will be Check the main power of the projector and Comm port
automatically recognized from the projector and indicated which is connected to the cable. Comm port connections
on the Main Dialogue. are suspect during a correspondence error, such as when
An error item on the screen will be displayed in red. Only there is no reply from the projector.
the last error which occurred is indicated on the Main Comm port to be used for [Setting serial (COM) Port...] on
Dialogue. If the warning data is not correctly recognized, it the [File] menu can be changed.
will not be indicated.
6. Termination of the program
3. Clearing of the warning data history Press the [Exit] button on the Main Dialogue to terminate
Be sure to press the [Clear History] button after correcting the program.