This product is provided with the self-diagnosis function. In case of any abnormality, the LED at the top of the product will
indicate the errors.
Diagnosis method : Every time the main power is turned on, the SW is turned on and each sensor is checked for any
errors in 4 seconds. The POWER LED remains red during the check.
Diagnosis result indication : LED indication and failures are shown in the following table. LED can be reset “automatically” or
“by turning on/off of the main power” when the fault detection is finished.
Forced power-on : When the product can’t be turned on because of STBY power short or SW power short, press the 3
buttons of RGB, VIDEO and CARD at the top of the product simultaneously during 4 seconds of
the sensor check to turn on the product for fault detection. In this case, protection circuits except
for STBY power short and SW power short will operate.
Danger Red/Green
4 LBOX open No power-on – – * Auto
Prevention alternately
Communication
Fault Red/Green
8 failure between the No power-on Orange Red * Auto
computers (serial) Detection alternately
1
LED Error Indication List
Warning
indication by
Red
LED Red – * Manual
flash
Indication
during stand-by
Lamp’s life Only warning
(1500~2000h) indication by LED
Warning
15
indication by
Red/Green
LED Green – * Manual
alternately
Indication
during stand-by
Lamp’s life
No power-on Lamp’s life Red Red – * Manual
(2000h or over)
Lamp Green
16 Lamp doesn’t light No power-on for 1 minute Red – * Auto
protection flash