Engineering Structures
journal homepage: www.elsevier.com/locate/engstruct
a r t i c l e i n f o a b s t r a c t
Article history: A finite element study was performed to investigate the effect of vertical loading on the in-plane lateral
Received 30 November 2015 behavior and strength of concrete masonry infills bounded by steel frames. An experimental program was
Revised 2 March 2016 also conducted and results were used to verify the finite element model. Parameters considered in the
Accepted 3 March 2016
finite element study included the vertical load level and application method, infill aspect ratio, infill com-
Available online 21 March 2016
pressive strength, and bounding frame stiffness. Results showed that when applied as a uniformly dis-
tributed load on the frame beam, an optimal load level was identified and the vertical load, when
Keywords:
applied within this load level, was found to be beneficial to the lateral stiffness and strength of the infilled
Concrete masonry infills
In-plane behavior
frame. When applied as point loads on columns, the vertical load was shown to reduce the lateral
Stiffness and strength strength of the infilled frame. Based on the regression analysis on finite element results, a simplified ana-
Combined vertical load and lateral load lytical model was proposed to account for the effect of vertical loading through the use of a modification
Finite element factor on the lateral stiffness and strength of infilled steel frames. The proposed model was shown to pro-
Analytical model vide results in good agreement with finite element values over a wide range of load levels, infill material
strengths, and frame stiffnesses.
Ó 2016 Elsevier Ltd. All rights reserved.
1. Introduction strut acting in compression to resist the lateral loading. Once the
strut width is known, a simple frame analysis can be performed
Behavior and capacity of masonry infills built inside concrete or to determine the stiffness of the system. The strength of the infill
steel frames have been given increasing research attention in can also be related to the diagonal strut width. Several analytical
recent years. It is widely accepted that when the infill is built in equations on the diagonal strut width have been proposed by var-
tight contact with the bounding frame with an intention to partic- ious researchers ([16–21]). However, several studies ([22–27]) also
ipate in the load sharing, its inherently large in-plane stiffness will showed that single-strut models were inadequate for capturing the
attract additional forces to the frame area and change the behavior force and moment in the members of the bounding frame and var-
of the frame system. If not designed properly, the structural integ- ious multi-strut models were then proposed to overcome such lim-
rity of both the infill and frame will be compromised. It is thus cru- itations. Regardless of single or multi-strut approach, proposed
cial to accurately evaluate the contribution of the infill to the equations were calibrated using experimental results to a specific
stiffness and strength of the frame system. To that end, consider- set of testing parameters and thus none was found to provide uni-
able amount of experimental research has been conducted with versally satisfactory estimate for infilled systems with different
majority being around 1980’s to 2000’s ([1–8]). With the develop- infill and frame material and geometric properties. In the case of
ment of computer technology in the past two decades, numerical micro-modeling, a smeared-crack continuum was often used to
studies using computer codified finite element methods have been model masonry infills. The mortar effect was accounted for using
shown to be an effective tool in research on masonry infills ([9– various interface models where different failure surfaces can be
15]). In finite element modeling, macro- and micro-modeling tech- implemented to simulate shear and tension failure at mortar joints.
niques are two often employed categories of techniques. The ‘‘diag- Al-Chaar and Mehrabi [28] showed that a combination of the
onal strut” concept is one of the commonly used macro-modeling smeared-crack continuum formulation developed by Lotfi and
methods, where the infill is replaced by an equivalent diagonal Shing [29] and the interface model developed by Mehrabi and
Shing [30] can be used for numerical study of infilled reinforced
concrete (RC) frames. In the finite element study conducted by
⇑ Corresponding author. Tel.: +1 (902) 494 1509; fax: +1 (902) 494 3108. Stavridis [31], masonry infills were modeled as rectangular
E-mail address: yi.liu@dal.ca (Y. Liu).
http://dx.doi.org/10.1016/j.engstruct.2016.03.010
0141-0296/Ó 2016 Elsevier Ltd. All rights reserved.
X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129 119
smear-crack continuum elements that were inter-connected with custom made one-third scale of standard 200 mm concrete masonry
zero-thickness interface elements with cohesive crack formulation unit (CMU). Partially grouted and fully grouted infills were consid-
developed by Lotfi and Shing [32]. In both cases, the model was ered. Three axial load levels including 111 kN, 80 kN, and 49 kN
shown to have the capability of predicting lateral load-carrying were considered and they represented from 2.8% to 6.4% of the axial
capacity and failure mechanisms of RC infilled frames. capacity of the W100 19 column. The test setup is shown in Fig. 1
Noting that all above mentioned research was conducted on (a). The steel frame was constructed using W100 19 steel section
infilled frames subjected to in-plane lateral loading only, this paper for all members. The steel section was selected according to the
focused on the investigation of vertical load effect on the lateral design guidelines specified in the Canadian steel design standard
stiffness and strength of the infilled frames. The presence of verti- CSA S16-14 [44]. The infill was simply positioned inside the steel
cal loading on the bounding beam or columns could be a common frame without any mechanical connectors between the infill and
occurrence in practice. If the bounding frame is an integral part of the frame. The infilled frame was then supported on a stiffened steel
the gravity loading system, the vertical load can be either applied beam which was in turn bolted to the strong floor through closely
through columns or beams depending on the framing plan. Fiorato spaced steel rods as seen in the figure. A hydraulic actuator with a
et al. [33], Mehrabi et al. [30], Manos et al. [34], and Stylianidis [35] capacity of 250 kN was used to apply lateral load to the failure of
conducted experimental tests on masonry infilled RC frames under the specimen. A skewed A-frame consisting of two steel columns
lateral load along with vertical load applied on the frame columns. provided a reaction support for the lateral load whereas two leaning
Test results showed that the vertical load applied on the frame col- columns provided out-of-plane bracing for the reaction column, as
umns resulted in an increase in the lateral stiffness and strength of shown in Fig. 1(b). In the case of combined lateral and axial loading,
the infilled system. Papia et al. [36] developed an analytical the axial load was first applied to the pre-determined level using a
method where the vertical load effect can be accounted for by mul- hydraulic jack and was kept constant as the lateral load applied till
tiplying a factor (k) to the diagonal strut width obtained for infills the failure of the specimen. A stiffened W beam was used to dis-
subjected to lateral load only. Based on finite element results tribute the axial load onto the top beam through the two roller
obtained by Cavaleri et al. [37], Amato et al. [38] and Campione assemblies at the two one-third points of the beam.
et al. [39] derived the k factors for square infills and rectangular
infills respectively to account for the presence of vertical loads 3. Finite element model
applied at the beam–column joints. Asteris [40] integrated the
work of Papia et al. [36] and Amato et al. [38] and proposed an ana- 3.1. Model description
lytical equation taking into account the effect of both the opening
in the infill wall and the vertical load applied at the beam–column The software ANSYS was used in the development of the model.
joints as well as the interaction between the two. The aforemen- In this study, a simplified micro-modeling technique was used
tioned studies were all on masonry infilled RC frames where the where the infill was modeled using homogeneous continuum ele-
k factors in these studies were developed for determination of only ments, and the mortar effect was simulated using a surface-based
the initial stiffness of the infilled systems. Comparing to infilled RC cohesive contact model to capture the cracking and sliding failure
frames, the research on infilled steel frames was limited in the of the mortar joints. A schematic view of the modeled infilled
available literature. One such study was conducted by Stafford- frame is shown in Fig. 2(a). The masonry infill was modeled using
Smith [41] nearly 50 years ago where infills made of just mortar a four-node plane stress element, PLANE42, placing in running
and bounded by steel bar frames were tested under a lateral load bond. Each masonry unit was expanded in each directions by the
and a uniformly distributed vertical load imposed on the upper half mortar thickness and the expanded mortar units interact with
beam of the frame. The study found that vertical load up to a cer- each other through the interface. The interface was modeled using
tain level increased the lateral stiffness and strength of the infill. surface-based cohesive contact pairs. Each contact pair consists of
However, no quantified correlation between the vertical load and a zero-thickness surface-to-surface cohesive zone interface ele-
the lateral stiffness and strength was provided. Due to different ment, CONTA171, and a zero-thickness target element TARGE169.
characteristics between RC and steel frames, it is believed that The CONTA171 element was used to detect contact or separation
extent of interaction between the infill and its bounding frame is between ‘‘target” surfaces (TARGE169) and a deformable surface
affected by the material of frames (eg. steel or RC). The results defined by the CONTA171 element. This interface element was also
obtained for RC bounding frames may not be directly applicable used for the contact between the infill and the frame members. The
to steel bounding frames. Hence, a finite element study was moti- geometry and configuration of inter-blocks contact pairs are
vated to investigate the effect of vertical loading on the in-plane shown in Fig. 2(b).
behavior and capacity of infills bounded by steel frames. Concur-
rent with the finite element study, an experimental program was 3.2. Material model and failure criteria
also conducted and the results obtained from this study as well
as those from the available literature were used to examine the An elastic perfect plastic material model was used for frame
robustness and efficacy of the finite element model. The main members where the elastic modulus and the yield strength of steel
objective of this study was to determine the correlation between were taken as 200 GPa and 350 MPa, respectively. The constitutive
the vertical load and the lateral stiffness and strength of the infilled model for masonry adopted the one proposed by Priestley and
steel frame. The effects of a wide range of geometric and material Elder [45] which was calibrated with experimental results and it
properties of the infilled frame, vertical load levels as well as man- is expressed in Eq. (1). It should be pointed out that this model
ners of application were included in the study. was assumed homogenous.
e 2
2e
0
fm
2. Experimental study e 6 0:0015; r ¼ ð1aÞ
0:9375 0:002 0:002
0:0015 6 e 6 0:0025; r ¼ zm ðe 0:0015ÞÞ
0
The experimental program was conducted by the same research f m ð1 ð1bÞ
group at the Dalhousie University [42,43]. Masonry infilled steel 0:5
frames subjected to either lateral loading or combined lateral and where zm ¼ 3þ0:29f 0 ð1cÞ
0
m
145f 1000
0:002
vertical loading were tested. The infill walls with an aspect ratio m
Load Cell
Reaction
Frame
1320 1800
W100x19
W100x19
W150x30
30
50x
W1
W100x19 LVDT 2
Stiffener 1351 W200x46
(b)
1931
1374
W
15
20
0x
13 0x
20
15
W
813 1356
Fig. 1. Test setup, dimensions in mm: (a) schematic view; and (b) out-of-plane bracing for the loading column.
Cracking and sliding failure of mortar joints were monitored The damage initiation criterion is defined using a Mohr–Cou-
using the linear elastic traction–separation laws as shown in lomb friction yield surface combined with a tension cut-off and
Fig. 3. Represented by the bilinear cohesive zone material model elliptical compression cap as shown in Fig. 4 where ft is the tensile
of the CONTA171 element, separation initiates when the maximum strength of mortar joint and u is the friction angle. Note that the
normal or shear stress in a contact pair reaches the corresponding compression cap was defined using a Hill type yield criterion pro-
strength. The shear stress and the relative slip behavior is plotted posed by Lourenço and Rots [47] to monitor the compression fail-
in Fig. 3(a) which shows separation begins at point A where the ure of masonry infill. This failure surface has been shown by
shear strength (st ) is achieved and is completed at point C when Lourenço [46] and Al-Chaar and Mehrabi [28] to produce reason-
the shear stress reaches zero. The softening stage provides mortar ably accurate estimates when compared with experimental results.
joints with a residual shear strength to account for the frictional
resistance of the joint after shear crack occurred. For tension sepa-
3.3. Boundary conditions and loading procedure
ration, a similar bilinear constitutive relationship but with a cut-off
was adopted. As Fig. 3(b) shows, once the tension stress in the con-
The frame beam-to-column connection was modeled as rigid
tact pair reaches the tensile strength (ft) of mortar joint, the contact
and the columns were assumed to be fix-supported at ends. A
pair is considered separated to represent the tensile cracking of
monotonically increased load with a defined load increment was
mortar joint. The values of the normal and shear stiffness were
applied at the frame beam level. During each increment of loading,
determined based on the following expressions suggested by Lour-
the stress was determined for each element based on its assigned
enҫo [46]:
constitutive model. The tensile and shear failure were checked at
the interface and the compression failure was checked at each
Eu Emor
kn ¼ ð3Þ masonry unit based on the failure surface defined above. If failure
t m ðEu Emor Þ was detected, the tangent stiffness of the element associated with
Gu Gmor the failure at that load increment was modified according to the
ks ¼ ð4Þ
t m ðGu Gmor Þ material constitutive model described above; and the analysis
was rerun with the updated system stiffness matrix until no new
where Eu and Emor, and Gu and Gmor are the Young’s moduli and failure was detected. The entire process was repeated for the sub-
shear moduli of masonry unit and mortar respectively; and tm is sequent increment of load. To obtain the falling branch in the load
the thickness of mortar joints. In lieu of experimental data, Gu and vs. lateral displacement response, an augmented spring was imple-
Gmor can be taken as 0.4Eu and 0.4Emor respectively. mented as shown in Fig. 2(a). In a load controlled analysis, the infill
X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129 121
Target element
(a) Node K Node L
Beam element
Applied Load
Node J Node I
Interface element
Augment Spring
Contact Normal
Fig. 2. (a) Finite element model of the infilled frame, and (b) configuration of a joint.
(a)
A Coulomb friction mode
t
Cap mode
Shear Stress
Tension
cut-off
ft
C
O
Fig. 4. Mohr–Coulomb friction yield surface.
0 u tA Slip utC
(b)
3.4. Verification of the finite model
ft A, cut-off point
Table 1
Detail description of the experimental specimens.
H (m) L (m) f0 m (MPa) Em (MPa) te (mm) Beam section Column section Vertical load (kN)
Infills subjected to combined loading
Liu and Manesh [42] CF-1 1.08 1.35 9.1 12,800 64 W100 19 W100 19 111
CF-2 1.08 1.35 9.1 12,800 64 80
CF-3 1.08 1.35 9.1 12,800 64 49
CP-1 1.08 1.35 9.4 10,100 43 111
CP-2 1.08 1.35 9.4 10,100 43 80
CP-3 1.08 1.35 9.4 10,100 43 49
Table 2 without vertical load. Given that specimens were from different
Stiffness and strength comparison of the experimental and FE results. studies, this shows that the finite element model is robust for dif-
Pexp
ferent material and geometric properties of infilled frames. Hence,
kexp Pexp kFE PFE kexp
kFE PFE
the modeling technique used in this study was deemed valid and
Infills subjected to combined loading effective and was then used in the subsequent parametric study.
Liu and Manesh [42] CF-1 37 198 36 203 1.03 0.98 From the point of view of experimental results, the combined load-
CF-2 32 169 32 163 1.00 1.04
ing study [42] shows that the presence of axial load resulted in an
CF-3 29 152 28 161 1.04 0.94
CP-1 26 126 28 133 0.93 0.95 increase in both the lateral stiffness and strength of the infilled
CP-2 25 120 27 129 0.93 0.93 frame and the higher the axial load, the greater the increase. How-
CP-3 26 109 24 99 1.08 1.10 ever, the available data points were not sufficient to define the
Avg 1.00 0.99
exact correlation.
C.O.V (%) 6 7
Load (kN)
Load (kN)
150
100
100
50
50
0 0
0 5 10 15 20 0 10 20 30
Displacement (mm) Displacement (mm)
Load (kN)
400
Load (kN)
100 300
200
50
100
0 0
0 10 20 30 40 50 0 10 20 30
Displacement (mm) Displacement (mm)
Fig. 5. Comparison of FE and experimental load vs. lateral displacement curves: (a) CF-1 [42]; (b) CF-2 [42]; (c) CF-3 [42]; and (d) WB2 [2].
Table 3
Summary of finite element models in the numerical study.
No. of models Vertical load level (%) H (m) L (m) Aspect ratio f0 m (MPa) Appl. method Frame type kL p
24 0–50 2.8 1.2–3.6 0.78–2.33 25 UDL Stand. 2.66–8.58 0–0.37
24 0–50 2.8 1.2–3.6 0.78–2.33 25 Point load Stand. 2.66–8.58 0–0.37
24 0–50 2.8 1.2–3.6 0.78–2.33 25 50-50 Stand. 2.66–8.58 0–0.37
10 0–40 2.8 2–2.8 1.00–1.40 15 UDL Stand. 4.17–5.92 0–0.29
6 0–50 2.8 3.6 0.78 15 UDL Stand. 7.55 0–0.30
5 0–40 2.8 2.8 1 10 UDL Stand. 5.35 0–0.30
18 0–50 2.8 2–3.6 0.78–2.33 25 UDL Strong 3.19–5.78 0–0.19
18 0–50 2.8 2–3.6 0.78–2.33 25 UDL Weak 5.70–10.32 0–0.37
covering a range of stocky to slender infills; three masonry com- the load vs. displacement response remains linear up to the first
pressive strengths (f0 m = 10, 15 and 25 MPa); and in addition to major cracking load.
the standard model, a strong frame (W310 129 columns and The finite element results showed that the effect of the vertical
W360 79 beam) and a weak frame (W150 24 columns and load level on the lateral stiffness and strength of the infilled system
W100 19 beam). Columns of the strong and weak frame have was also dependent on the aspect ratio of the infill. This collective
an EI/L approximately 5 and 0.5 times respectively those of the effect can be seen in Fig. 6 where the applied vertical load V versus
standard model frame. normalized cracking stiffness and ultimate load are plotted. The
stiffness and ultimate load values are normalized with respect to
the model of each aspect ratio but without vertical load. Fig. 6
shows that the presence of vertical load affects both the stiffness
5. Discussion of results and strength of infilled systems to various degrees depending on
infill aspect ratios. Overall, there seems to exist an optimal vertical
5.1. Effect of vertical load level, V load level up to which an increase in the vertical load results in an
increase in both stiffness and strength of the system. A further
In this case, the material and geometric properties of the stan- increase above this level, however, the stiffness and strength begin
dard model was used and the vertical load was assumed to be to decrease gradually. This optimal load level varies for different
applied as a UDL on the frame beam. Please note that in this as well infill aspect ratio and this is discussed in more detail in the next
as the following sections, unless otherwise stated, the term ‘‘stiff- section.
ness” refers to the cracking stiffness which was defined as the The increase in stiffness and strength due to the presence of
secant stiffness at the load corresponding to the first major diago- vertical load is believed to be attributed to the increase in diagonal
nal crack, immediately after which a marked load drop occurred on strut width caused by the vertical load. This is qualitatively shown
the response curve. The crack stiffness rather than initial stiffness in Fig. 7. The strut width of the infill without vertical loading (Fig. 7
was selected because previous studies ([8,21]) suggested that the (a.i)) is much narrower than that of the infill with vertical load
initial stiffness had more scatter due to the initial ‘‘engaging” stage (Fig. 7(b.i)) during the loading. For the latter case, even after local-
of the infill and the frame and does not accurately represent the ized corner crushing of infill, there is still relatively large region in
system stiffness once they behave together. The crack stiffness contact between the beam and infill at failure (Fig. 7(b.ii), which
was a more reliable indicator of the system stiffness. In most cases, enables the more possible loading paths for lateral load transfer
124 X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129
Fig. 7. FE distribution of compressive stress in the infill (a) subjected to only lateral load,; (b) subject to combined loading: (i) early stage of loading, (ii) at failure.
X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129 125
50 benefit of vertical load is better realized for strong infills than for
weak infills.
Optimal Load Level
40 Cracking Stiffness
(a) 2.0
(a)2.0
Normalized Stiffness
1.5
Normalized Stiffness
1.5
1.0
1.0
0.5
0.5
0.0
0.0 0 10 20 30 40 50
0 10 20 30 40 50 60 V (%)
V (%) (b)
(b) 2.0
2.0
Normalized Sttrength
1.6 1.5
Normalized Strength
1.2
1.0
0.8
0.5
0.4
0.0 0.0
0 10 20 30 40 50 60 0 10 20 30 40 50
V (%) V (%)
f’m =25MPa f’m = 15MPa f’m = 10MPa Weak frame Standard frame Strong frame
Fig. 9. Effect of masonry compressive strength on (a) cracking stiffness, and (b) Fig. 10. Effect of frame stiffness on (a) cracking stiffness and (b) strength of the
strength of the infilled frame. infilled frame.
126 X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129
1.6
Based on the diagonal strut approach, the effect of vertical load-
ing on the lateral stiffness and strength of the infilled frame may be
1.2 considered through a modification factor MF to the stiffness and
strength of the infill subjected to lateral load only. Note that the
‘‘stiffness” used in this section also refers to the cracking stiffness
0.8
0 10 20 30 40 50 as defined in Section 5. Due to the complexity of the problem, this
V (%) study focused on vertical load applied as a UDL to the frame beam.
UDL Point Load 50- 50
To develop an analytical model that incorporates effects of afore-
mentioned factors and also is simple to use, this study adopted
Fig. 11. Effect of vertical loading application methods on (a) cracking stiffness, and the use of the unit-less factor kL to account for effects of both infill
(b) strength of the infilled frame. aspect ratio and relative infill and frame stiffness, and proposed the
use of a vertical load ratio p as a measurement of vertical load level.
increases while the lateral strength of the infilled system showed Term k was commonly used in previous studies [14–19] and can be
an approximately linear decrease. When the vertical load is applied defined as:
in the 50–50 manner, both the stiffness and strength seem to sffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi
4 Em t sinð2hÞ
increase in a linear relationship with the increase in vertical load. k¼ ð5Þ
This suggests that the benefit of vertical load applied through the 4Ef Ic H
beam outweighs the detrimental effect of vertical load applied where Em and Ef are the elastic moduli of masonry and the frame
through columns, resulting in a net result of beneficial effect on respectively; t, H and L are the thickness, height, and length of infill,
the lateral stiffness and strength of the infill. respectively; Ic is the moment of inertia of the column, and
The difference in behavior due to the manner of vertical load h = tan1(H/L). The ratio p is defined as the applied vertical load
application is believed to be attributed to the load sharing between divided by the combined axial capacity of columns and infill and
the infill and the frame. Table 4 lists the loads transferred through can be expressed as:
two columns, Vc, and the ratio of this load to the total applied ver-
tical load, V for the case of V equal to the 10% of axial capacity of V
p¼ 0 ð6Þ
columns. The table shows that the columns experience signifi- f m tL þ 2Ac f y
cantly different amount of load among the three application meth-
where V is the applied vertical load, f0 m is the infill strength, Ac is the
ods. When the vertical load is applied as a UDL on the frame beam,
column cross-sectional area, and fy is the yield strength of steel col-
the amount of load transferred through columns depends on the
umns. The resulted kL and p values for all model specimens ranged
infill aspect ratio and more load is transferred to infills as the
from around 3 to 10.5 and 0 to 0.37 respectively as summarized in
aspect ratio increases. The load transferred to infill will effectively
Table 3.
increase the contact regions between the beam and the infill.
This study proposes that the modification factor MF be
When the vertical load is applied through columns, the majority
expressed as follows where f(p) and g(kL) are two independent
of this load is directly transferred into columns (about 83%) which
functions:
leaves a small portion (about 17%) transferred through infills. Thus
the contact regions developed between the beam and infill are less MF ¼ 1 þ f ðpÞgðkLÞ ð7Þ
than the former case. Instead, the shortening of columns makes
Fig. 12 plots the relationship between p and normalized stiff-
loaded corner highly stressed. The already stressed corner crushes
ness and strength of infilled model specimens. For clarity, three
much earlier and more extensively as lateral load is applied than
kL scenarios are shown in the figure. The details of each scenario
the case when no vertical load is present. This is believed to attri-
are described as follows: (1) kL = 2.66 corresponds to an infill with
an aspect ratio of 2.33 and f0 m = 25 MPa and bounded by the stan-
Table 4
Vertical load transferred through columns for different load application methods
dard frame; (2) kL = 4.53 corresponds to an infill with an aspect
(V = 10% of axial capacity of column W250 28). ratio of 1.00 and f0 m = 25 MPa and bounded by the strong frame;
(3) kL = 7.55 corresponds to an infill with an aspect ratio of 0.78
Aspect ratio UDL Point load 50–50
and f0 m = 15 MPa and bounded by the standard frame. These three
Vc (kN) Vc/V (%) Vc (kN) Vc/V (%) Vc (kN) Vc/V (%) scenarios cover different combinations of infill aspect ratio, f0 m and
2.33 331.4 63.8 447.6 86.2 395.6 76.2 frame stiffness therefore were chosen as examples for demonstra-
1.40 209.6 40.4 434.0 83.6 337.4 65.0 tion. Fig. 12 shows that the relationship between p and the increase
1.00 150.4 28.9 430.4 82.9 307.0 59.1
in stiffness and strength is approximately parabolic. This observa-
0.78 117.4 22.6 430.0 82.8 288.4 55.5
tion is also true for other kL values in this study. Fig. 13 plots the kL
X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129 127
1.5
illustrated in Fig. 14 where three scenarios of kL are illustrated. It
can be seen that the proposed analytical equations achieve a good
1.0 agreement with FE results. When FE results were compared with
the equation values for all models, the stiffness Eqs. (8) and (9)
0.5 obtained a R2 = 0.954 while the strength Eqs. (10) and (11)
obtained a R2 = 0.978, indicating a good performance of analytical
model over a wide range of parameters. It is noted though that
0.0 the failure mode of all FE models was by corner crushing and hence
0 0.1 0.2 0.3 0.4
Eqs. (10) and (11) should be used corresponding to this failure
p
mode.
(b) 2.0
6.3. Application of MF and limitations
Normalized Strength
1.5
The modification factor, developed based on normalized stiff-
ness and strength trend as described above, is intended to be used
1.0
to modify the stiffness and strength of the infills subjected to lat-
eral load only. It is noted though that this modification factor equa-
0.5 tion was developed for infills bounded by steel frames with vertical
load applied through frame beams. For other bounding frame
0.0 material or vertical load applied in different manners, this set of
0 0.1 0.2 0.3 0.4 equations is not directly applicable. Although the loading consid-
p
L = 2.66 L = 4.53 L = 7.55
Fig. 12. Vertical load ratio p vs (a) normalized stiffness and (b) normalized strength. (a) 2.0
120
1.5
Maximum Percentage Increase
Normalized Stiffness
100
80
1.0
60
40
0.5
20
0
2 4 6 8 10 0
λL 0 0.1 0.2 0.3 0.4
Stiffness Strength
p
Linear trend line Linear trend line (b) 2.0
(stiffness) (strength)
For strength: Fig. 14. Analytical model values vs. FE results: (a) stiffness and (b) strength.
128 X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129
ered was static, it is believed that the behavior trend and effects of [10] Dawe JL, Seah CK, Liu Y. A computer model for predicting infilled frame
behaviour. Can J Civ Eng 2001;28:133–48.
parameters discussed are still valid for seismic loading situation.
[11] El-Dakhakhni WW. Nonlinear finite-element modelling of concrete masonry-
However, the analytical equations proposed should be thoroughly infilled steel frame. MScE thesis. Philadelphia: Drexel University; 2002.
validated with results from seismic tests of infilled frames. Since [12] Stavridis A, Shing PB. Finite-element modeling of nonlinear behavior of
the model used a single frame configuration with no openings in masonry-infilled RC frames. J Struct Eng ASCE 2010;136(3):285–96.
[13] Mohyeddin A, Goldsworthy HM, Gad EF. FE modelling of RC frames with
the infill, its applicability to multi-storey, multi-bay infilled frames masonry infill panels under in-plane and out-of-plane loading. Eng Struct
and infills with openings needs further investigation. 2013;51:73–87.
[14] Gambarotta G, Lagomarsino S. Damage models for the seismic response of
brick masonry shear walls. Part I: the mortar joint model and its applications.
7. Conclusions Earthq Eng Struct Dyn 1997;26:423–39.
[15] Gambarotta G, Lagomarsino S. Damage models for the seismic response of
brick masonry shear walls. Part II: the continuum model and its application.
A finite element model was developed to study the in-plane Earthq Eng Struct Dyn 1997;26:441–62.
stiffness and strength of masonry infills bounded by steel frames [16] Stafford-Smith B, Carter C. A method for the analysis of infilled frames. Proc
Inst Civ Eng 1969;44:31–48.
subjected to combined lateral and vertical loading. A parametric
[17] Mainstone R. On the stiffnesses and strengths of infilled frames. Proc Inst Civ
study on the effect of vertical load levels, loading methods, infill Eng 1971(Supplement IV):57–90.
aspect ratio and strength, and frame stiffness on the lateral stiff- [18] Wood RH. Plasticity, composite action and collapse design of unreinforced
shear wall panels in frames. Proc Instit Civ Eng 1978;65:381–411.
ness and strength of infilled frames was conducted. A set of analyt-
[19] Liauw TC, Kwan KH. Plastic theory of non-integral infilled frames. Proc Instit
ical equations was proposed to account for these parameters in the Civ Eng 1983;75(3):379–96.
determination of infilled system stiffness and strength under com- [20] Flanagan RD, Bennett RM. In-plane behavior of structural clay tile infilled
bined loading. Some conclusions stemmed from this study are as frames. J Struct Eng 1999;125(6):590–9. ASCE.
[21] Tucker CJ. Predicting the in-plane capacity of masonry infilled frames. Ph.D
follows: Thesis. Tennessee: Tennessee Technological University; 2007.
When applied as a UDL on the frame beam, the presence of ver- [22] Thiruvengadam V. On the natural frequencies of infilled frames. Earthq Eng
tical load, up to a certain level, results in an increase in the lateral Struct Dyn 1985;13(3):401–19.
[23] Chrysostomou CZ. Effects of degrading infill walls on the nonlinear seismic
stiffness and strength of the infilled system. And beyond that level, response of two-dimensional steel frames. Ph.D. thesis. Ithaca, NY: Cornell
the benefit of vertical load begins to diminish. This load level is Univ.; 1991.
defined as the optimal level. The optimal load level is found to [24] Hamburger RO, Chakradeo AS. Methodology for seismic-capacity evaluation of
steel-frame buildings with infill unreinforced masonry. Proc., National
be dependent on the infill aspect ratio, infill strength, and the Earthquake Conf., vol. 2. Memphis, TN: Central U.S. Earthquake Consortium;
bounding frame stiffness. 1993. p. 173–91.
When the vertical load is applied on columns, the lateral stiff- [25] Crisafulli FG. Seismic behaviour of reinforced concrete structures with
masonry infills. Ph.D. thesis. Christchurch, New Zealand: Univ. of
ness of infilled system is increased with an increase in the vertical
Canterbury; 1997.
load level. However, the lateral strength shows a decrease. When [26] Chrysostomou CZ, Gergely P, Abel JF. A six-strut model for nonlinear dynamic
the vertical load is applied in a 50–50 manner on both the frame analysis of steel infilled frames. Int J Struct Stab Dyn 2002;2(3):335–53.
[27] El-Dakhakhni WW, Elgaaly M, Hamid AA. Three-strut model for concrete
beam and columns, infilled systems show almost linearly increas-
masonry-infilled steel frames. J Struct Eng 2003;129(2):177–85.
ing stiffness and strength as the load level increases. [28] Al-Chaar B, Mehrabi A. Constitutive models for nonlinear finite element
A set of equations for calculating modification factor MF for ver- analysis of masonry prisms and infill walls, Report ERDC/CERL TR-08-19. US
tical load effect is proposed for vertical load applied to the frame Army Corps of Engineers; 2008.
[29] Lotfi HR, Shing PB. An appraisal of smeared crack models for masonry shear
beam case. The equations are shown to produce results in good wall analysis. Comput Struct 1991;41(3):413–25.
agreement with FE values for a wide range of vertical load levels. [30] Mehrabi AB, Shing PB, Schuller MP, Noland JL. Experimental evaluation of
The development of MF also considered the effect of aspect ratio masonry-infilled RC frames. J Struct Eng 1996;122(3):228–37.
[31] Stavridis Andreas, Analytical and experimental study of seismic performance
and material strength of infills as well as frame stiffness. of reinforced concrete frames infilled with masonry walls. Ph.D. Dissertation.
San Diego, La Jolla, CA: University of California; 2010.
[32] Lotfi HR, Shing PB. An interface model applied to fracture of masonry
Acknowledgements structures. J Struct Eng, ASCE 1994;120(1):63–80.
[33] Fiorato AE, Sozen MA, Gamble WL. An investigation of the interaction of
The authors wish to recognize the contribution of financial reinforced concrete frames with masonry filler walls. Technical Report No.
UILU-ENG 70-100. Urbana-Champaign, Illinois: University of Illinois; 1970.
assistance by the Canadian Concrete Masonry Producers Associa- [34] Manos GC, Soulis VJ, Thauampteh J. The behavior of masonry assemblages and
tion and Natural Sciences and Engineering Research Council of masonry-infilled R/C frames subjected to combined vertical and cyclic
Canada. horizontal seismic-type loading. Adv Eng Softw 2012;45:213–31.
[35] Stylianidis KC. Experimental investigation of masonry unfilled R/C frames.
Open Constr Build Technol J 2012;6(Suppl 1–M13):194–212.
References [36] Papia M, Cavaleri L, Fossetti M. Infilled frames: developments in the evaluation
of the stiffening effect of infills. Struct Eng Mech 2003;16(6):675–93.
[37] Cavaleri L, Fossetti M, Papia M. Effect of vertical loads on lateral response of
[1] McBride R. The behaviour of masonry infilled steel frames subjected to racking.
infilled frames. In: Proceedings 13th world conference on earthquake
MScE Thesis. New Brunswick, Canada: University of New Brunswick; 1984.
engineering, Vancouver, Canada, No. 2931; 2004.
[2] Yong TC. Shear strength of masonry infilled panels in steel frames. MScE
[38] Amato G, Cavaleri L, Fossetti M, Papia M. Infilled frames: influence of vertical
Thesis. New Brunswick, Canada: University of New Brunswick; 1984.
load on the equivalent diagonal strut model. In: The 14th world conference on
[3] Amos K. The shear strength of masonry infilled steel frames. MScE Thesis. New
earthquake engineering. Beijing, China; 2008
Brunswick, Canada: University of New Brunswick; 1985.
[39] Campione G, Cavaleri L, Macaluso G, Amato G, Di Trapani F. Evaluation of
[4] Dawe JL, Seah CK. Behaviour of masonry infilled steel frames. Can J Civ Eng
infilled frames: an updated in-plane-stiffness macro-model considering the
1989;16(6):865–76.
effects of vertical loads. Bull Earthq Eng 2015:2265–81. http://dx.doi.org/
[5] Henderson RC. Experimental and analytical investigation of out-of-plane and
10.1007/s10518-014-9714-x. Online publication date: 1-Aug-2015.
in-plane seismic drift in un-reinforced masonry infilled frames. PhD
[40] Asteris PG, Cavaleri L, Di Trapani F, Sarhosis V. A macro-modelling approach
Dissertation. Knoxville: the University of Tennessee; 1994.
for the analysis of infilled frame structures considering the effects of openings
[6] Flanagan RD. Behavior of structural clay tile infilled frames. PhD Dissertation.
and vertical loads. Struct Infrastruct Eng 2015:1–16. http://dx.doi.org/
Knoxville: The University of Tennessee; 1994.
10.1080/15732479.2015.1030761.
[7] Al-Chaar G. Non-ductile behaviour of reinforced concrete frames with masonry
[41] Stafford-Smith B. Model tests results of vertical and horizontal loading of
infill panels subjected to in-plane loading. USACERL Technical Manuscript 99/
infilled frames. Am Concr Instit, ACI J 1968;65(8):618–25.
18, US Army Corps of Engineers, Construction Engineering Research
[42] Liu Y, Manesh P. Concrete masonry infilled steel frames subjected to combined
Laboratory. Champaign, Illinois; 1998.
in-plane lateral and axial loading – an experimental study. Eng Struct
[8] Liu Y, Soon S. Experimental study of concrete masonry infills bounded by steel
2013;52:331–9.
frames. Can J Civ Eng 2012;39(2):180–90.
[43] Liu Y, Soon S. Experimental study of concrete masonry infills bounded by steel
[9] Mehrabi AB, Shing PB. Finite element modeling of masonry-infilled RC frames.
frames. Can J Civ Eng 2012;39(2):180–90.
ASCE J Struct Eng 1997;123(5):604–13.
X. Chen, Y. Liu / Engineering Structures 117 (2016) 118–129 129
[44] CAN/CSA S16-14. Design of steel structures. ON, Canada: Canadian Standard [47] Lourenço PB. Computational strategies for masonry structures. PhD thesis.
Association; 2014. Delft, Netherlands: Civil Engineering Department, Delft University of
[45] Priestley MJN, Elder DM. Stress–strain curves for unconfined and confined Technology; 1996.
concrete masonry. ACI J 1983;80(3):192–201. [48] CAN/CSA S304.1-04. Design of masonry structures. ON, Canada: Canadian
[46] Lourenço PB, Rots JG. A solution for the macro-modelling of masonry Standard Association; 2004.
structures. In: Proceedings of the 11th international brick/block masonry
conference. Shanghai, China: Tongji University; 1997. p. 1239–49.