Figure 1
Function description
Temperature measurement
The cooling oil temperature is measured at four points in order to enable control of brake cooling oil circulation:
{ temperature sensor SE5215 is located on front axle in the distribution block for brake cooling oil (distributes brake
cooling oil out to the hubs on the axle)
{ temperature sensor SE5216 is located on front bogie axle in the distribution block for brake cooling oil
{ temperature sensor SE5217 is located on rear bogie axle in the distribution block for brake cooling oil
{ temperature sensor SE5207 is located in the brake cooling oil tank
Figure 2
Frame with axles and hose routing for brake cooling oil
Figure 3
Pump unit
Application of brakes
When brakes are applied and brake cooling needs to increase (at least one of the temperature sensors send signal if the
temperature is above 80 °C (176 °C)) a signal is sent to the actuator (PWM5201) to supply max. flow of brake cooling oil. At the
same time a signal is sent to increase rpm of the cooling fan which cools the coolant from the heat exchanger where the brake
cooling oil is cooled. The signal increases in linear manner from 0 % at 80 °C (176 °F), which gives min. rpm for the cooling fan,
to 100% at 100 °C (212 °F), which gives max. rpm for the cooling fan. When the actuator (PWM5201) supplies max. flow and the
cooling fan's rpm increases, the rpm for the pump unit also increases (see also 900 Hydraulic system, description).
Then when the temperature of the brake cooling oil drops below 80 °C (176 °F) the cooling fan returns to min. rpm, on the
condition that request for increased cooling fan rpm is not generated from the engine cooling system or the transmission's
cooling circuit, see 260 Cooling unit, description. When the brake cooling oil temperature is below 77 °C (171 °F) the actuator
(PWM5201) returns to supplying basic flow.
Pump unit's rpm
To ensure cooling of the brakes, there is a control function in the machine's software.
If the machine's engine is on and the pump unit's rpm (measured by rpm sensor SE2607) is below 100 rpm for at least 5
seconds (continuously), then a signal is sent to increase the cooling fan's rpm to 35% of the span between min. and max. rpm. A
signal is also sent to the actuator for control of the hydraulic motor in the pump unit, about max. flow.
Other functions that affect the brake cooling oil system
The coolant system that cools the brake cooling oil in the heat exchanger also circulates through the heat exchanger where the
oil for the transmission is cooled, see 260 Cooling unit, description. The circulation pump for the coolant system for brakes and
transmission is the coolant pump that is located in the pump unit described above. If the temperature in the transmission
exceeds 90 °C (194 °F) (measured by sensor in oil sump), a signal is sent to the actuator for control of the hydraulic motor in the
pump unit (PWM5201) to supply max. flow.
Same request from several sub-functions
{ If any of the above sub-functions in the software send a signal to the actuator for control of the hydraulic motor for the
pump unit (PWM5201) about max. flow, then max. flow shall be requested.
{ If several of above sub-functions send a signal to increase cooling fan rpm, the highest value shall be that which is
requested, unless the max. rpm is not exceeded, see above under heading Pump unit's rpm.
Regardless of the request for increasing the flow, basic flow is always set on the pump unit if brake charging is requested.
Control lights and alarms on the operator's panel
{ If the temperature of the brake cooling oil becomes too high, control lights are activated on the operator's panel as
follows:
– if the machine's engine is on and any, or some of the temperature sensors for the brake cooling oil
shows that the temperature exceeds 120 °C (248 °F) for at least 5 seconds, then orange central
warning is activated on the operator's panel. The control light turns off when the brake cooling oil
temperature has dropped below 118 °C (244 °F).
– if the machine's engine is on and the brake cooling oil temperature reaches above 130 °C (266 °F)
for at least 5 seconds, then red central warning is activated on the operator's display, at the same
time as a buzzer sounds. The control light turns off and the buzzer shuts off when the brake cooling
oil temperature has dropped below 128 °C (262 °F).
{ If the machine's engine is running and the pump unit's rpm is below 100 rpm for 15 seconds, then red central
warning is activated.
{ In case of too low level of brake cooling oil in the tank, red central warningis activated on the operator's display. The
oil level in the brake cooling oil tank is monitored using a level monitor (SE5214). Sensing of the oil level shall show
below the warning level for at least 3 seconds in order for red central warning light to be activated on the operator's
display. This is to avoid incorrect sensing due to oil sloshing around in the tank when operating.
Software description
Request for brake cooling oil circulation is based on control Request brake cooling oil circulation
temperature with hysteresis according to the following:
With engine On basic flow is set to 750 rpm, and goes to 480 rpm after
60 seconds.
Supplementary information
For more information on speed (rpm) sensor SE2607, see 3021 SE2607, description and measuring.
For more information on actuator PWM5201, see 3021 PWM5201, description and measuring.
For more information on temperature sensor SE5207, see 3021 SE5207, description and measuring.
For more information on level sensor SE5214, see 3021 SE5214, description and measuring.