FONTUS WATER PVT. LTD.

Inspection Report for Pumps

OA No : FWL-0194 Project : Bharti Airtel Ltd., Lucknow


Delivery Date : 24/04/2012 Date of Inspection : 24/04/2012
Title/Duty point : Hypochloride Dosing Pump MOC : PP
Flow & Head : 12 LPH AT 2KG/CM2 Report No. : F-IQC-0194-01 DT.24-04-12
Vendor Name/location : M/s. DWS Services Inc.

P.O. No. : FWL/11-12/PO/DEL/1607 DT.19-MAR-2012 Invoice No. : 2474/2011-2012

Reference P & I/BOQ no : FWL-0194-11-101 Rev No : 3

Required as per Inspection Result


Inspection Point BOQ/Specs/PO
Make & Model : Milton Roy/ V-13 PP Milton Roy/ V-13 PP
Flow Rate m3/hr : 12LPH 12LPH
Head in Kg/cm2/ mmWC : 2kg/cm2 2kg/cm2
MOC of Casing : PP PP
MOC of Shaft : NA NA
MOC of Impeller : NA NA
Serial number/Name plate
details : As mentioned Sr.no.: 33494
RPM : 100 SPM 100 SPM
Motor kw/rpm/ protection
details : 100SPM 100SPM

Motor Phase : 1Phase 1Phase


Motor Serial number/name
plate details : NA NA

Alignment of Motor & unit : Integral Integral


Workmanship/Finish : Satisfactory Satisfactory

Test Certificate Availability : To be provided Test & Warranty Certificate Available


Remarks by Inspector

The above mentioned pump is clear for dispatch for Bharti Airtel Ltd.,Lucknow
Type of Inspection (tick) Stage Inspection/Final Inspection

Signature