A) ASME 31.3
A) Heating and cooling rates > 316°C shall not exceed 222°C/hr. ÷ weld thickness in inches, but in no case > 222°C/hr.
And min soaking temp is 1hr.
6. Area to be insulated?
A). each side 300mm. below 150 °C should not remove insulation.
A). Electric resistance heaters, Induction heaters, semi-permanent or permanent furnace s using, gas or oil heaters.
8. THERMOCOUPLE SPACED?
A) Temperature recorders shall be calibrated every three months and a current calibration sticker shall be maintained on
the recorder. The calibration frequency may be extended to 12 months with the approval of Saudi Aramco Inspection
A) TC shall be attached to the component by Capacitor discharge weld. 0.5meter outside from the insulated area.